1E3X-SD
Easy-teach digital fiber amplifier
E3X-SD
The E3X-SD easy-teach fiber amplifier is the ideal solution for
all standard fiber applications. The one-button teaching and/
or the simple threshold adjustment with up/down keys and the
easy to read display allow an intuitive usage and fast set up.
easy one-button teaching
easy to read display and simple threshold adjustment with
up/ down keys for intuitive usage
GIGA RAY LED for high performance and precision
Ordering Information
Amplifier Unit Connectors (sold separately)
Note: Stickers for Connectors are included as accessories.
Accessories (sold separately)
Shape Item Order code
NPN output PNP output
Pre-wired E3X-SD21 2M E3X-SD51 2M
Fiber amplifier connector*1 E3X-SD7 E3X-SD9
*1. Order connector separately. For M8 connector models see E3X-DA-S.
Shape Type Comment Order code
Fiber amplifier
connector
2 m PVC cable E3X-CN21*1
30 cm PVC cable with M12 plug connector (4 pin) E3X-CN21-M1J 0.3M
30 cm PVC cable with M8 plug connector (4 pin) E3X-CN21-M3J-2 0.3M
*1. 4-wire version. For 3-wire version order E3X-CN11.
Mounting Brackets
Appearance Model Quantity
E39-L143 1
End Plate
Appearance Model Quantity
PFP-M 1
2Easy teach fiber amplifier
Ratings and Specifications
Amplifier Units
Item E3X-SD@
Light source (wavelength) Red, 4-element LED (625 nm)
Power supply voltage 12 to 24 VDC 10%, ripple (p-p): 10% max.
Power consumption/
Current consumption
960 mW max. (Power supply voltage: 24 V,
Current consumption: 40 mA max.) (Power supply voltage: 12 V, Current consumption: 80 mA max.)
Control output Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.)
Light-ON/Dark-ON mode selector
Response time Operate or reset: 200 s max.
Sensitivity adjustment UP/DOWN direct key setting, teaching with/without a workpiece, automatic teaching
Protection circuits Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection
Mutual interference
prevention Up to 5 Amplifiers (optically synchronized)*1
*1. Mutual interference prevention is effective when E3X-SD-series Amplifiers are gang-mounted without other E3X-series Amplifiers.
Ambient illumination
Receiver side
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Number of gang-mounted
Amplifiers 16 max. (The ambient temperature specification depends on the number of gang-mounted Amplifiers.)
Ambient temperature
range
Operating: Groups of 1 to 3 Amplifiers: 25C to 55C
Groups of 4 to 11 Amplifiers: 25C to 50C
Groups of 12 to 16 Amplifiers: 25C to 45C
Storage: 30C to 70C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M. min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
Connection method Pre-wired (standard cable length: 2 m), or connector
Weight (packed state) Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g
Material Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC)
Accessories Instruction manual
3E3X-SD
Output Circuit Diagrams
Out-
put
form
Model
Output
transistor
operation
mode
Timing charts Operation
selector Output circuit
NPN
Out-
put
E3X-
SD21
E3X-SD7
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
PNP
Out-
put
E3X-
SD51
E3X-SD9
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Black
Brown
Blue
Control output
Operation indicator
(orange)
Photo-
electric
Sensor
main
circuit
Load
12 to
24 VDC
1
4
3
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
1
4
3
Black
Brown
Blue
Control output
Operation
indicator
(orange) Photo-
electric
Sensor
main
circuit Load
12 to
24 VDC
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
4Easy teach fiber amplifier
Safety Precautions
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not exceed the rated voltage.
Excess voltage may result in malfunction or fire.
Do not use an AC power supply.
Using an AC power supply may result in rupturing..
High-temperature environments may result in burn
injury.
The following precautions must be observed to ensure safety.
1. Do not use the product in locations where flammable or explo-
sive gas is present.
2. Do not use the product in locations subject to splashing water,
oil, or chemicals, or in locations subject to steam.
3. Do not attempt to disassemble, repair, or modify the product.
4. Do not apply voltage or current in excess of the rated ranges.
5. Do not use the product in atmospheres or environments that
exceed product ratings.
6. Do not wire the product incorrectly, such as using incorrect
power supply polarity.
7. Connect the load properly.
8. Do not short-circuit both ends of the load.
9. Do not use the product if the case is damaged.
10. When disposing of the product, dispose of it as industrial
waste.
11. Do not use the product in locations subject to direct sunlight.
12. The surface temperature of the product may rise as a result of
the ambient temperature, power supply, or other usage con-
ditions. Use caution when performing maintenance and
washing. Failure to do so may result in burn injury.
Do not use the product in atmospheres or environments that ex-
ceed product ratings.
Amplifier Units
Designing
Communications Hole
The hole on the side of the Amplifier Unit is a communications
hole for preventing mutual interference when Amplifier Units are
mounted side-by-side. The E3X-MC11 Mobile Console (sold sep-
arately) cannot be used.
If an excessive amount of light is received via the Sensor, the mu-
tual interference prevention function may not work. In this case,
make the appropriate adjustments using the sensitivity adjuster.
Mutual interference prevention is effective when E3X-SD-series
Amplifiers are gang-mounted without other E3X-series Amplifi-
ers.
Mounting
DIN Track Mounting/Removal
Mounting Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and press
the Amplifier Units together until they click into place.
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the
DIN track one at a time. (Do not attempt to remove Amplifier Units
from the DIN track without separating them first.)
! Warning
! Caution
Precautions for Safe Use
Precautions for Correct Use
Note 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before mounting or removing
Amplifier Units.
Click into
place
Clip
5E3X-SD
Fiber Connection and Disconnection
The E3X Amplifier Unit has a lock lever. Connect or disconnect
the fibers to or from the E3X Amplifier Unit using the following pro-
cedures:
1. Connection
Open the Protective Cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the
lock lever.
2. Disconnection
Remove the Protective Cover and raise the lock lever to pull out
the fiber.
Note: To maintain the fiber properties, confirm that the lock is released
before removing the fiber.
3. Precautions for Fiber Connection/Disconnection
Be sure to lock or unlock the lock lever within an ambient temper-
ature range between 10C and 40C.
Operating Environment
Ambient Conditions
If dust or dirt adhere to the hole for optical communications, it may
prevent normal communications. Be sure to remove any dust or
dirt before using the Units.
Other
Protective Cover
Be sure to mount the Protective Cover before use.
Amplifier Units with Connectors
Mounting
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit un-
til it clicks into place.
2. Join Amplifier Units together as required after all the Master
and Slave Connectors have been inserted.
3. Attach the stickers (provided as accessories) to the sides of
Master and Slave Connectors that are not connected to other
Connectors.
Note: Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to re-
move Connectors without separating them from other Amplifi-
er Units first.)
Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier Unit may move dur-
ing operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the master
Amplifier Unit using a nipper or similar tool.
The clip can also be removed using the following mechanism,
which is incorporated in the construction of the section under-
neath the clip.
1. Insert the clip to be removed into the slit underneath the clip on
another Amplifier Unit.
2. Remove the clip by rotating the Amplifier Unit.
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.
Lock lever
Fiber Fiber insertion mark
10.7 mm
Insertion position
Locked Unlocked
Protective Cover
Insert
Sticker
Sticker
Remove
Lever
Press down
Clip
Rotate
6Easy teach fiber amplifier
Dimensions
Amplifier Units
(Unit: mm)
Tolerance class IT16 applies to dimensions in this sheet unless otherwise specified.
18
4.3
8
10.7
10
10
3.4
22.4
4.4
13
64.3
64.3
16
10.75
16
8
10.7
3 128.95
128.95
3 128.95
128.95
2.4
4
2.4
4
10.75
16
10 10
L
(9)
3.4
31.5 31.5
(9)
3.4
31.5 31.5
(9.4)
18
93.75
93.75
1010
15
93.75
93.75
13
12.4 30.4
64.3 64.3
Operation indicator
Two,
2.4 dia.
Two,
2.4 dia.
Hole for optical communications
Hole for optical communications
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
End Plate
(sold separately)
PFP-M
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Fiber Attachment mounted (E39-F9)
Two, M 3
Mounting Holes
With Mounting Bracket Attached
Multiple connection diagram
DIN track mounting
Vinyl-insulated round cable
4 dia. cable / 3 conductors / Standard length: 2 m
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
Two, 3.2 dia. holes
Amplifier Units with Cables
E3X-SD21
E3X-SD51
The number of
expansion L (mm)
110
220
330
440
550
660
770
880
990
10 100
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side.
7E3X-SD
Amplifier Units with Connectors
E3X-SD7
E3X-SD9
Cable Diameters
E3X-CN11 (3 conductors) 4.0 dia.
E3X-CN12 (1 conductor) 2.6 dia.
The number of
expansion L (mm)
110
220
330
440
550
660
770
880
990
10 100
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side.
8Easy teach fiber amplifier
Amplifier Unit Connectors (Wire-saving Connectors)
Accessories (sold separately)
Master Connector
E3X-CN11
(7)
2,000 +50
0
E3X-CN11: 4 dia.
4 dia.
cable / 3 conductors
3 conductors
/ Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Edge of amplifier
Slave Connector
E3X-CN12
(7)
2,000 +50
0
E3X-CN12: 2.6 dia.
2.6 dia.
cable / 1 conductor
1 conductor
/ Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Edge of amplifier
Mounting Brackets
E39-L143
Four, R1.7
7
3.4
1
3163
10 max. 710.3
7.3
5.3
(10.3) 2.5
34.8
22
16
26.8
3
Two, 3.2 dia.
3.4
1
Two, M3
16±0.1
Mounting Holes
Material: Stainless steel
(SUS304)
End Plates
PFP-M
50
11.5
10
M4 × 8
panhead screw
M4 spring washer
4.8
1.3
1.8
1.8
1
6.2 10
35.5
35.3
9E3X-SD
Nomenclature
Operating Procedure
Sensitivity Setting
The sensitivity can be set with the UP and DOWN Keys similar to
using an adjuster knob. The sensitivity can also be easily set by
using the following two teaching functions.
Teaching with/without a Workpiece
Two points (one with the workpiece and the other without) are de-
tected, and the operating level is set to the midpoint.
Light level is also automatically set to the optimal value.
Automatic Teaching
Changes within a time are detected, and the operating level is set
to the midpoint between the maximum and the minimum values
of the changes. This setting is optimal for when the workpieces
cannot be stopped. Execute automatic teaching again if the inci-
dent light level is not automatically set to the optimal value.
Digital threshold value adjustment
(UP/DOWN)
Te aching status
indication(orange)
Operation Selector
Use to switch between
Light-ON and Dark-ON
Lock Lever
Digital incident light level display or
digital threshold value display (red)
Display of contents of functions
during operation
Light-ON and
Dark-ON Indicator
Te aching Button
The sensitivity and threshold
value can be set automatically.
Operation Indicator
(Orange)
Amplifier Units
E3X-SD
Operation description Button/Key
Press the TEACH button with the
workpiece.
Press the TEACH button without the
workpiece.
TEACH
TEACH
Operation description Button/Key
Press the TEACH button for 3 s min.
Let the workpiece pass while the
button is pressed.
TEACH
10 Easy teach fiber amplifier
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products.
Please consult your OMRON representative if you have any ques-
tions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from de-
fects in materials and workmanship for a period of one year (or other
period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EX-
PRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MER-
CHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF
THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF
THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDI-
RECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT,
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the in-
dividual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRAN-
TY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS
UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PROD-
UCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE,
MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT
SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR
ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RE-
LIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DE-
VICE FOR SUCH PURPOSES. Please refer to separate catalogs for
OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards,
codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use that
apply to the products. This information by itself is not sufficient for a
complete determination of the suitability of the products in combina-
tion with the end product, machine, system, or other application or
use.
The following are some examples of applications for which particular
attention must be given. This is not intended to be an exhaustive list
of all possible uses of the products, nor is it intended to imply that the
uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or
electrical interference, or conditions or uses not described in this
document.
Nuclear energy control systems, combustion systems, railroad sys-
tems, aviation systems, medical equipment, amusement machines,
vehicles, safety equipment, and installations subject to separate in-
dustry or government regulations.
Systems, machines, and equipment that could present a risk to life
or property.
Please know and observe all prohibitions of use applicable to the
products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO AD-
DRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN
THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for
the user in determining suitability and does not constitute a warranty.
It may represent the result of OMRON’s test conditions, and the users
must correlate it to actual application requirements. Actual perfor-
mance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time
based on improvements and other reasons.
It is our practice to change model numbers when published ratings or
features are changed, or when significant construction changes are
made. However, some specifications of the product may be changed
without any notice. When in doubt, special model numbers may be as-
signed to fix or establish key specifications for your application on
your request. Please consult with your OMRON representative at any
time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for man-
ufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is
believed to be accurate; however, no responsibility is assumed for
clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a pro-
grammable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without
permission.
This document is protected by copyright and is intended solely for use
in conjunction with the product. Please notify us before copying or re-
producing this document in any manner, for any other purpose. If
copying or transmitting this document to another, please copy or
transmit it in its entirety.
11E3X-SD
12 Easy teach fiber amplifier
In the interest of product improvement, specifications are subject to change without notice.Cat. No. E67E-EN-01
OMRON EUROPE B.V.
Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
www.industrial.omron.eu