FED. MFG. CODE 91929
+
REVISIONS
ISSUE
DRAWING
NUMBER
DRAWN
CHECK CHECK CHECK RELEASE NO. REPLACES
PTC/CAD
THIRD ANGLE PROJECTION
SCALE
DO NOT SCALE PRINT
+
WEIGHT
CATALOG LISTING
THIS DRAWING COVERS A PROPRIETARY ITEM AND IS THE PROPERTY OF MICRO SWITCH. A DIVISION OF
HONEYWELL. THIS DRAWING IS NOT TO BE C OPIED OR USED WITHOUT THE APPROVAL OF MICRO SWITCH.
+
-
-
-
ONE PLACE (.0) .030
TWO PLACES (.00) .015
THREE PLACES (.000) .005
ANGLES
Honeywell Division
UNLESS OTHERWISE SPECIFIED
TOLERANCES ARE
ANSI Y14.5M-1982 APPLIES
PAGE
45
1.8
121,00#0,40
4.764#.015
73,2
2.88
21 APR 98
FF-SRS SERIES CHART 1
4
1 OF 1
GRT 12 MAR 98 DR-4989 -
FF-SRS SERIES
CHART 1
SAFETY CONTROL MODULE
(EMERGENCY STOP MODULE)
NONE
FF-SRS SERIES
CHART 1
APR-REL
PR-22595
GRT
12 MAR 98
3D
JAF
B205765
WJC
17 JUN 02 FF-SRS59 __ _
VOLTAGE:
2 = 24 VDC
E = 120 VAC
K1
K2
K1 K2
14 24
24 VDC
23
13
X1X2T34T33A1(+)
34 = 1 CHANNEL CONNECTION
35 = 1 CHANNEL OR 2 CHANNEL CONNECTION
K3
K2
K3K2
MONITORING
LOGIC
14 24
24 VDC
OVERVOLTAGE
AND SHORT CIRCUIT
PROTECTION
23
13
S34
S33
S22S12
S11
A2(-)
A1(+)
POWER K1/K2
K1
K2
K1 K2
PTC
A2(-)
FF-SRS5934 CIRCUIT DIAGRAM
34 42
41
33
S21/PE(-)
K2 K3
FF-SRS5935 CIRCUIT DIAGRAM
C0051891
MBN
06 MAY 09
06 MAY 09
CMH
MOUNTING RAIL
REMOVAL
MOUNTING