Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • P 908.806-9400 • F 908.806.9490 • www.altechcorp.com
Motor Control
SOLID STATE RELAYS
17
This new AC single phase softstarter is engineered to the highest quality and is designed especially for single phase motors
32A/230Vac with starting capacitor (e.g. compressor for heat pumps or refrigerating chambers).
This device is designed in compliance with EN60947-4-2.
SYMC To limit peak energy demand!
Product
reference
Pmax motors
230VAC Max. Current Specifi cations Dimensions
mm
SYMC0001
5500W 32A Internal ByPass
Ready to use 100 x 76 x 58,5
• Starting current limited to 45A (NFC15-100)
• Over-load motor protection
• Diagnostic information
• Starting and running capacitor: External and not supplied
Product
reference
Switching
voltage
Switching
current Control voltage Dimensions
mm
Fig
n°
SO400200 200-260VAC 35A Soft-starter 45 x 58,2 x 27 1
SO400300 200-260VAC 40A* 2
*Value given at 25°C ambient
For the softstart of other loads (transformers, single-phase motors, …) please consult us.
*The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling
of the motor. Each channel is wired in series with a winding of the motor.
This range of single-phase softstarters is designed for universal motors or lamps.
Motor control:
• Effi cient reduction of torque and starting current.
Incandescent or infrared lamp starting :
• Reduction of in rush current
• Increase in life expectancy.
Transformer control (loaded):
• Elimination of saturation current
• Improved control and protection.
Whatever your application:
SO4 Single phase softstarters
SMCV AND SMCW Three-phase AC softstarters
with integrated heatsink
Common characteristics Range of voltage and
network frequency Control Diagnostic output Operating
temperature Insulation
Values given at 40°C ambient 200-480VAC 40-65Hz 10-24VDC or contact 0-24V 1A AC/DC -40°C +100°C 4kV
Product
reference
Pmax motor
400VAC
Y* D*
Pmax motor
230VAC
Y* D*
Max. Current AC53a
Max. EN60947-4-2
Specifications Dimensions
mm
SMCV6080 7,5kW 13kW 4,3kW 7,5kW 16A 11,5A
Heatsink not provided 100 x 76 x 58,5
SMCV6110 11kW 19kW 6,4kW 11kW 25A 15,5A
SMCV6150 15kW 26kW 8,6kW 15kW 30A 22,5A
SMCW6020 2,5kW 4,3kW 1,4kW 2,5kW 5,6A 4A
Supplied with built-in
heatsink
83 x 110 x 74
SMCW6080 7,5kW 13kW 4,3kW 7,5kW 16A 11,5A 83 x 110 x 155
SMCW6110 11kW 19kW 6,4kW 11kW 25A 15,5A 110 x 110 x 180
SMCW6150 15kW 26kW 8,6kW 15kW 30A 22,5A 110 x 141 x 180
SMCW6151 15kW 26kW 8,6kW 15kW 30A (AC53b) 22,5A (AC53b) Ext. Bypass required 83 x 110 x 74
• Diagnostic monitoring of line, load & supply
as well as normal operational status
• Better balance of and less interference on starters
(full control of the 3 phases!)
• Simple use easing implementation and adjustments
• As compact as an electronic contactor.