USA: 1-888-41-ASTEC Europe (UK): +44(0)1384-842211 Asia (HK): 852-2437-
44
SPECIAL FEATURES
•Active power factor correction
•EN61000-3-2 compliance
•Remote sense on outputs one and two
•Industry-standard 4.25” x 7” footprint
•Adjustable main outputs
•Built-in Class B EMI filter
•Overvoltage protection
•Overload protection
•Thermal overload protection
ENVIRONMENTAL
Operating temperature: 0° to 50°C ambient;
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to
meet EN61000-4, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
20% to 90%
Vibration: 5-32 Hz sinewave .02” double
amplitude 32-2 kHz sinewave 1 G peak
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF per MIL STD 217E: >200,000 hours at
full load and 30°C ambient conditions and full
load
ELECTRICAL SPECIFICATIONS
Input
Input range ........................... 90-264 VAC
Frequency ............................ 47-63 Hz
Inrush current....................... 40 A max., cold start @ 25°C
Efficiency.............................. 65% typical at full load
EMI filter ...............................FCC Class B conducted and radiated,
CISPR 22 Class B conducted and radiated,
EN55022 Class B conducted and radiated,
VDE 0878 PT3 Class B conducted and
radiated.
Power factor .........................0.99 typical
Safety ground
Leakage current ...................<2 mA @ 50/60 Hz, 254 VAC input
Output
Maximum power................... 70 W convection; 120 W with 30 CFM forced
air
Adjustment range ................. ±5% minimum on 3.3 V and 5 V outputs
Hold-up time......................... 15 ms @ 120 W load, 115 VAC input
Overload protection.............. Short circuit protection on all outputs. Case
overload protected @ 110145% above peak
rating
Overvoltage protection ......... 3.3 V output: 4.25 V ±.25 V
5 V output: 6.25 V ±.75 V, 20-35% above
nominal output. Latching type recycle AC to
reset.
Remote sense ...................... Compensates for 0.5 V lead drop min. Will
operate without remote sense connected.
SAFETY
TUV EN60950 9837006
UL UL1950 E186249
CUL CSA 22.2-234 Level 3 E186249
CB Certificate and report DE2-002056
CE Mark (LVD)
Net Series
AA20140
AA20140
Input V oltages
85 - 264VAC
# of Outputs
Quad
T otal Power
70 - 120 Watts
•LP pg 40-65 05/26/2000, 1:27 PM44