https://www.phoenixcontact.com/us/produkte/2864273 Resistance thermometer measuring transducer - MINI MCR-SLPT100-UI-NC - 2864273 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://download.phoenixcontact.com) MCR temperature transducer for Pt 100 temperature sensors, configured via DIP switch, with screw connection, not pre-configured Product description The 6.2 mm wide MINI MCR-SL-PT100-UI... is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of Pt 100 resistance thermometers according to IEC 60751 in 2, 3 and 4-wire connection methods. On the output side, the analog standard signals 0...20 mA, 4...20 mA, 0...10 V, 0...5 V, 1...5 V, 10...0 V, 20...0 mA or 20...4 mA are available, electrically isolated. The DIP switches are accessible on the side of the housing and allow the following parameters to be configured: - Connection method - Temperature range to be measured - Output signal as well - Fault evaluation type Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector. Why buy this product Power supply possible via the foot element (T-connector) For 2, 3 or 4-wire Pt 100 sensors according to IEC 60751 Error indication via diagnostic LED and analog signal Input and output signals can be configured via DIP switches Highly-compact temperature transducer for electrical isolation, conversion, amplification, and filtering of 3-way isolation Pt 100 signals to create standard signals Temperature measuring range of -150C to +850C Key commercial data Packing unit 1 Minimum order quantity 1 Catalog page Page 362 (IF-2011) GTIN Custom tariff number 85437090 05.12.2012 Page 1 / 7 https://www.phoenixcontact.com/us/produkte/2864273 Resistance thermometer measuring transducer - MINI MCR-SLPT100-UI-NC - 2864273 Country of origin GERMANY Technical data Note: Utilization restriction The operation of this device does not meet the general EMC protection requirements for residential areas. Please take the appropriate precautions. Input data Configurable/programmable Yes Sensor types (RTD) that can be used Pt 100 (IEC 60751/EN 60751) Sensor input current 1 mA (constant) Connection method 2, 3, 4-wire Output data Configurable/programmable Yes, unconfigured Voltage output signal 0 V ... 10 V Voltage output signal 10 V ... 0 V Voltage output signal 0 V ... 5 V Voltage output signal 1 V ... 5 V Current output signal 0 mA ... 20 mA Current output signal 4 mA ... 20 mA Current output signal 20 mA ... 0 mA Current output signal 20 mA ... 4 mA Max. output voltage Approx. 12.5 V Max. output current 23 mA Short-circuit current Approx. 10 mA Load/output load voltage output 10 k Load/output load current output < 500 (at 20 mA) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Max. current consumption < 21 mA (at 24 V DC) Power consumption < 500 mW Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 2.5 mm Conductor cross section AWG/kcmil min. 26 Conductor cross section AWG/kcmil max 12 05.12.2012 Page 2 / 7 https://www.phoenixcontact.com/us/produkte/2864273 Resistance thermometer measuring transducer - MINI MCR-SLPT100-UI-NC - 2864273 Technical data Connection data Stripping length 12 mm Screw thread M3 General data No. of channels 1 Width 6.2 mm Height 93.1 mm Depth 102.5 mm Maximum temperature coefficient < 0.02 %/K Protective circuit Transient protection Ambient temperature (operation) -20 C ... 65 C Ambient temperature (storage/transport) -40 C ... 85 C Degree of protection IP20 Electrical isolation Basic insulation according to EN 61010 Surge voltage category II Pollution degree 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position Any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D EMC data Name Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 10 % Name Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 10 % Name Conducted interferences Standards/regulations EN 61000-4-6 05.12.2012 Page 3 / 7 https://www.phoenixcontact.com/us/produkte/2864273 Resistance thermometer measuring transducer - MINI MCR-SLPT100-UI-NC - 2864273 Technical data EMC data Typical deviation from the measuring range final value 10 % Classifications ETIM ETIM 2.0 EC001446 ETIM 3.0 EC001446 ETIM 4.0 EC001446 ETIM 5.0 EC001446 UNSPSC UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 eCl@ss eCl@ss 4.0 27200206 eCl@ss 4.1 27200206 eCl@ss 5.0 27200206 eCl@ss 5.1 27200206 eCl@ss 6.0 27200206 eCl@ss 7.0 27200206 Approvals Approvals Approvals UL Recognized / cUL Recognized / GL / cULus Recognized Ex Approvals UL Listed / cUL Listed / ATEX / cULus Listed Approvals submitted Approval details 05.12.2012 Page 4 / 7 https://www.phoenixcontact.com/us/produkte/2864273 Resistance thermometer measuring transducer - MINI MCR-SLPT100-UI-NC - 2864273 Approvals UL Recognized cUL Recognized GL cULus Recognized Accessories Accessories Electronic housing - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector (TBUS), 5-pos., for bridging the supply voltage, can be snapped onto NS 35/... DIN rails according to EN 60715 Power terminal block - MINI MCR-SL-PTB - 2864134 MCR power terminal block for supplying several MINI Analog modules via the T-connector, with screw connection, maximum current consumption of up to 2 A Power terminal block - MINI MCR-SL-PTB-SP - 2864147 MCR power terminal block for supplying several MINI Analog modules via the T-connector, with spring-cage connection, maximum current consumption of up to 2 A 05.12.2012 Page 5 / 7 https://www.phoenixcontact.com/us/produkte/2864273 Resistance thermometer measuring transducer - MINI MCR-SLPT100-UI-NC - 2864273 Accessories Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983 DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A Power supply unit - MINI-PS-100-240AC/24DC/1.5/EX - 2866653 DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A, ATEX approval System adapter - MINI MCR-SL-V8-FLK 16-A - 2811268 Eight MINI analog signal converters with screw connection method can be connected to a control system using a system adapter and system cabling with a minimum of wiring and very low error risk. Transparent cover - MINI MCR DKL - 2308111 Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker strip 6.2 mm Marking label - MINI MCR-DKL-LABEL - 2810272 Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL Drawings 05.12.2012 Page 6 / 7 https://www.phoenixcontact.com/us/produkte/2864273 Resistance thermometer measuring transducer - MINI MCR-SLPT100-UI-NC - 2864273 Block diagram Dimensioned drawing (c) Phoenix Contact 2012 - all rights reserved http://www.phoenixcontact.com 05.12.2012 Page 7 / 7