E2F E2F Plastic Cylindrical Inductive Prox E2F Short Length, Shielded Sensors With Threaded Plastic Body Rugged, watertight plastic housing offers good chemical resistance and withstands washdown Wide operating voltages: 10 to 30 VDC and 20 to 264 VAC Operation indicator on all models Short-circuit protection available on all DC and some AC models Ordering Information DC THREE-WIRE PREWIRED MODELS Type Shielded Size Sensing distance M8 1.5 mm M12 2 mm M18 5 mm M30 10 mm Output configuration NO NC NPN E2F-X1R5E1 E2F-X1R5E2 PNP E2F-X1R5F1 E2F-X1R5F2 Part number NPN E2F-X2E1 E2F-X2E2 PNP E2F-X2F1 E2F-X2F2 NPN E2F-X5E1 E2F-X5E2 PNP E2F-X5F1 E2F-X5F2 NPN E2F-X10E1 E2F-X10E2 PNP E2F-X10F1 E2F-X10F2 AC TWO-WIRE PREWIRED MODELS Without Short-CIrcuit Protection Type Shielded Size Sensing distance Part number NO NC E2F-X1R5Y2 M8 1.5 mm E2F-X1R5Y1 M12 2 mm E2F-X2Y1 E2F-X2Y2 M18 5 mm E2F-X5Y1-US E2F-X5Y2-US M30 10 mm E2F-X10Y1-US E2F-X10Y2-US With Short-CIrcuit Protection Type Shielded Size Sensing distance Part number NO NC M18 5 mm E2F-X5Y1-53-US E2F-X5Y2-53-US M30 10 mm E2F-X10Y1-53-US E2F-X10Y2-53-US 2 E2F E2F ACCESSORIES Description Mounting brackets Part number Fits M8 size sensors Y92E-B8 Fits M12 size sensors Y92E-B12 Fits M18 size sensors Y92E-B18 Fits M30 size sensors Y92E-B30 REPLACEMENT PARTS Description Mounting hardware: one pair of plastic nuts Part number Fits M8 size sensors (supplied with each sensor) M8-PHWS Fits M12 size sensors (supplied with each sensor) M12-PHWS Fits M18 size sensors (supplied with each sensor) M18-PHWS Fits M30 size sensors (supplied with each sensor) M30-PHWS 3 E2F E2F Specifications DC 3-WIRE MODELS Part number E2F-X1R5 Sensor Type Inductive Body Size M8 Type Shielded E2F-X2 E2F-X5 E2F-X10 M12 M18 M30 Supply voltage 10 to 30 VDC Current consumption 17 mA max. Detectable object type Metallic objects Effective maximum detecting distance (with standard target) 1.5 mm (0.06 in) 15% 2 mm (0.08 in) 10% 5 mm (0.20 in) 10% 10 mm (0.39 in) 10% Usable detecting range (with standard target) 0 to 1.2 mm (0 to 0.05 in) 0 to 1.6 mm (0 to 0.06 in) 0 to 4 mm (0 to 0.16 in) 0 to 8 mm (0 to 0.31 in) Standard target size (mild steel, L x W x H) 8 x 8 x 1 mm (0.31 x 0.31 x 0.04 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) Differential travel Control output DC solidstate 10% max. of effective max. detecting distance Type NPN-NO open collector with pull-up (E2F-XE1) NPN-NC open collector with pull-up (E2F-XE2) PNP-NO open collector with pull-down (E2F-XF1) PNP-NC open collector with pull-down (E2F-XF2) Max. load 200 mA Max. on-state voltage drop 2 VDC Response frequency 2 Hz Circuit protection Ouput shortcircuit Provided; automatic resetting type DC power supply reverse polarity Provided Weld field immunity Not provided RFI immunity Indicators Materials Plastic Sensing face Plastic Two plastic M18 nuts included. Bracket Y92E-B18 optional. Two plastic M30 nuts included. Bracket Y92E-B30 optional. Approx. 130 g (4.6 oz) Approx. 170 g (6.0 oz) Plastic Two plastic M8 nuts included. Bracket Y92E-B8 optional. Prewired Weight with cable Approvals 400 Hz Not provided Housing Cable sheath Enclosure ratings 600 Hz Target Present (red LED) Mounting Connections 1.5 kHz 3-conductor cable, 2 m (6.56 ft) length Approx. 40 g (1.4 oz) UL -- NEMA 1, 3, 4, 6, 12, 13 IEC 144 IP68 UL -- CSA -- Ambient operating temperature Two plastic M12 nuts included. Bracket Y92E-B12 optional. Approx. 50 g (1.8 oz) -25C to 70C (-13 to 158F) Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Shock Approx. 100 G 4 E2F E2F AC 2-WIRE MODELS Part number E2E2F-X1R5Y Sensor Type Body E2F-X2Y E2F-X5Y-US E2F-X5Y-53-US E2F-X10Y-US E2F-X10Y-53-US M12 M18 M30 Inductive Size Type Supply voltage M8 Shielded 20 to 264 VDC, 50/60 Hz 20 to 264 VAC, 50/60 Hz (E2F-XY-US) 90 to 140 VAC, 50/60 Hz (E2F-XY-53-US) Current consumption 5 mA max. Detectable object type Metallic objects Effective maximum detecting distance (with standard target) 1.5 mm (0.06 in) 15% 2 mm (0.08 in) 10% 5 mm (0.20 in) 10% 10 mm (0.39 in) 10% Usable detecting range (with standard target) 0 to 1.2 mm (0 to 0.05 in) 0 to 1.6 mm (0 to 0.06 in) 0 to 4 mm (0 to 0.16 in) 0 to 8 mm (0 to 0.31 in) Standard target size (mild steel, L x W x H) 8 x 8 x 1 mm (0.31 x 0.31 x 0.04 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) Differential travel 10% max. of effective max. detecting distance Control output AC solidstate Type SCR-NO (E2F-XY1--) SCR-NC (E2F-XY2--) Max. load 100 mA Min. load 5 mA 300 mA for E2F-XY-US and E2F-XY-53-US at -25C to 70C (-13F to 158F) 500 mA for E2F-XY-US at -25C to 55C (-13F to 131F) Max. off-state 1.7 mA at 200 VAC leakage current Max. on-state voltage drop See "Residual Load Voltage Characteristics" graph in Engineering Data. Response frequency 25 Hz Circuit protection Ouput shortcircuit Not provided Weld field immunity Not provided RFI immunity Indicators Materials Housing Polyarylate Polyarylate Polyvinal Chloride Two plastic M8 nuts included. Bracket Y92E-B8 optional. Prewired Weight with cable Approvals Not provided Sensing face Cable sheath Enclosure ratings Provided on E2F-XY-53-US types only; manual resetting type Output Operation (red LED) Mounting Connections 1.7 mA at 200 VAC (E2F-XY-US) 1.5 mA at 200 VAC (E2F-XY-53-US) Two plastic M12 nuts included. Bracket Y92E-B12 optional. Two plastic M18 nuts included. Bracket Y92E-B18 optional. Two plastic M30 nuts included. Bracket Y92E-B30 optional. Approx. 130 g (4.6 oz) Approx. 170 g (6.0 oz) 2-conductor cable, 2 m (6.56 ft) length Approx. 40 g (1.4 oz) UL -- NEMA 1, 3, 4, 6, 12, 13 Approx. 50 g (1.8 oz) 1 IEC 144 IP68 UL -- Recognized, File number E76675 -- Certified, FIle number LR45951 CSA Ambient operating temperature -25C to 70C (-13 to 158F) Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Shock Approx. 100 G 5 E2F E2F Operation OUTPUT CIRCUIT DIAGRAM AND TIMING CHARTS DC 3-Wire Models AC 2-Wire Models With Short-Circuit Protection 6 E2F E2F Engineering Data Operating Range Shielded M8 and M12 Size Sensors E2F-X1R5 , E2F-X2 Shielded M18 and M30 Size Sensors E2F-X5 , E2F-X10 Detecting Distance vs. Size and Material of Target Shielded M8 and M12 Size Sensors E2F-X1R5 , E2F-X2 Shielded M18 and M30 Size Sensors E2F-X5 , E2F-X10 Note: If the target is a nonferrous metal, the operating distance of the proximity sensor decreases. However, with a piece of foil measuring about 0.01 mm (0.0004 in) in thickness, the detecting distance is equivalent to that with a ferrous metal. Note that the proximity sensor cannot detect extremely thin evaporated films and non-conductive targets. 7 E2F E2F Residual Load Voltage Characteristics Leakage Current Characteristics 8 E2F E2F Dimensions Unit: mm (inch) SENSORS DC 3-Wire Models AC-2-Wire Models 9 E2F E2F AC Shielded M18 Size without short-circuit protection -US E2F-X5Y AC Shielded M18 Size with short-circuit protection -53-US E2F-X5Y OPTIONAL MOUNTING BRACKETS Applicable sensor models Part number Drawing dimensions A B Y92E-B8 18 0.2 (0.71 0.01) 10 18 8 28 M4 x 20 (0.39) (0.71) (0.31) (1.10) bolt max. dia. max. E2F-X1R5E(F)(Y) Y92E-B12 24 0.2 (0.94 0.01) 12.5 20 12 37 M4 x 25 (0.49) (0.79) (0.47) (1.46) bolt max. dia. max. E2F-X2E(F)(Y) Y92E-B18 32 0.2 (1.26 0.01) 17 30 18 47 M5 x 32 (0.67) (1.18) (0.71) (1.85) bolt max. dia. max. E2F-X5E(F)(Y)-US, E2F-X5Y-53-US Y92E-B30 45 0.2 (1.77 0.01) 17 50 30 60 M5 x 50 (0.67) (1.97) (1.18) (2.36) bolt max. dia. max. E2F-X10E(F)(Y)-US, E2F-X10Y-53-US 10 C D E F E2F E2F Precautions TIGHTENING FORCE Do not exceed the torque listed in the table provided when tightening the mounting nuts. Part number Maximum torque kg-cm in-lbs E2F-X1R5 8 6.93 E2F-X2 8 6.93 E2F-X5-(53)-US 20 17.32 E2F-X10-(53)-US 20 17.32 EFFECTS OF SURROUNDING METALS When mounting a proximity sensor flush with a metallic panel, be sure to provide a minimum distance as shown in the table below. This prevents the sensor from being effected by metallic objects other than the target. l d D m Drawing dimension Sensor model E2F-X1R5 E2F-X2 E2F-X5 E2F-X10 mm inch mm inch mm inch mm inch l 0 0 0 0 0 0 0 0 d (dia.) 8 0.31 12 0.47 18 0.71 30 1.18 D 0 0 0 0 0 0 0 0 m 4.5 0.18 8 0.31 20 0.79 40 1.57 MUTUAL INTERFERENCE To prevent mutual interference between two sensors, be sure to space the two sensors at a distance greater than that shown in the table below. Drawing dimension B A Sensor model E2F-X1R5 E2F-X2 E2F-X5 E2F-X10 mm inch mm inch mm inch mm inch A 20 0.79 30 1.18 50 1.97 100 3.94 B 15 0.59 20 0.79 35 1.38 70 2.76 OMRON ELECTRONICS LLC OMRON ON-LINE OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. 416-286-6465 Printed in the U.S.A.