MIT400 CAT IV Industrial Insulation Testers MIT400 CAT IV Industrial Insulation Testers DESCRIPTION The new Megger MIT400 series insulation and continuity testers has been designed for electrical testing by the utilities, industrial, commercial and domestic electricians. The wide range of features also makes the MIT400 series ideal for the maintenance and service/repair engineer. They replace the well-established BM400 insulation tester range, given greater functionality with simplified operation, greater application range and increased safety. The range The range consists of five instruments: CAT IV 600 V applications TRMS & DC Voltage measurement Insulation testing up to 1000 V and 200 G Continuity testing at 200 mA or 20 mA down to 0.01 Pass/Fail limit alarms Combined Analogue and dual digital display PI/DAR and Timer function Test result storage (MIT420) Bluetooth(R) wireless data transfer (MIT430) Analogue arc - The display also features an analogue arc to replicate the response of a moving coil display. PI and DAR - Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) functions 200 G - Insulation testing from 20 G (MIT400) to 200 G (MIT420 and MIT430). Silicone leads - High quality flexible silicone test leads are comfortable to use and prevent measurement errors on higher G ranges. Test inhibit - prevents testing if voltages in excess of 50 V are detected when making insulation tests. Insulation buzzer - The buzzer can be set to buzz if the insulation resistance is above a preset limit, set via the Setup menu. MIT400 250 V, 500 V and 1000 V MIT410 50 V, 100 V, 250 V, 500 V and 1000 V + PI, DAR MIT420 50 V, 100 V, 250 V, 500 V & 1000 V + PI, DAR and result storage CONTINUITY TESTING Auto-test - Auto test on circuit contact enables real two handed operation without the need to press the test button. 200 mA or 20 mA - Either 200 mA or 20 mA continuity test currents are available. 20 mA test current will considerably increase battery life. Lead null - Lead resistance compensation (NULL) operates up to 9.99 of resistance. Buzzer - ON-OFF selected by simple push button. Buzzer limit - Continuity buzzer limit alarm provides adjustment of the maximum resistance the continuity buzzer sounds. This is adjustable from 1 to 20 in 5 steps. MIT430 50 V, 100 V, 250 V, 500 V & 1000 V + Bluetooth download MIT40X 10 V to 100 V in 1 V steps INSULATION TESTING Test voltages - 250 V to 1000 V or 50 V to 1000 V insulation test voltages available Test Lock - Locks insulation test on continuously. Test voltage display - The actual test voltage is displayed on the smaller digital readout, with the insulation result on the larger digital display. MIT400 Series Industrial Insulation Testers k range extends resistance measurement to 1 M. DISPLAY The display offers a combination of analogue arc and a dual digital readout: Analogue arc: Full display width analogue arc. Patented arc display shows essential charge and discharge characteristics not visible on a digital display. Single pointer "needle" response is similar to a moving coil meter. Logarithmic display for better low insulation value measurements. NOTE: The receiving PC needs to have Bluetooth capability or a USB port fitted a Bluetooth receiver. Class II (10m) is acceptable. SAFETY Designed to be exceptionally safe to use, fast detecting circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases. Specifically, all instruments: Meet the international requirements of IEC1010-2 and EN61557. Live circuit detection inhibits insulation testing on circuits above 50 V. Large main digital readout for good visibility of all main measurement results Live circuit detection and test inhibit on continuity measurements. Default display of live circuit voltage on all ranges. Second digital display for additional data such as: Detection and inhibit functions even if the protection fuse has failed. Suitable for use on CAT IV applications and supply voltages to 600 V. Dual digital display: transmitter being enabled when the Download mode is selected on the instrument. Insulation test voltage. Insulation leakage current. Supply frequency (when measuring volts). Test mode eg. PI, DAR or TI (Timed mode). MIT40X - VARIABLE INSULATION VOLTAGE TESTER. The MIT40X provides a unique solution for awkward insulation voltage measurement applications. The MIT40X has a variable insulation test voltage from 10 V to 100 V in 1 V steps, selectable in the "Set-Up" menu. Once selected this can only be changed by re-configuring in the Setup menu. Typical applications include: Commercial avionics Military land, marine and air communications Manufacturing/production line goods Electrostatic measurement Component testing Battery powered traction and lifting equipment STORAGE & DOWNLOADING RESULTS MIT420 The MIT420 is capable of saving test results for recall to the screen. A simple storage structure allows for a test number and screen results to be recalled individually. MIT430 The MIT430 supports both test result storage and downloading. Test results can be stored in the instrument and subsequently downloaded to a computer with the Megger download manager software. Data transfer is by Bluetooth, with the MIT485 Bluetooth 600 V CAT IV All MIT400 instruments are designed to meet the safety requirements for use on CAT IV 600 V. APPLICATIONS (A) Electrical installations testing: The MIT400 includes all the features required for electricians and engineers working in a range of industries. Available features are selected to make testing easy and fast in a range of situations. Typical industries include: Electrical supply companies Large and small scale electrical installation Periodic inspection and testing Cable testing (B) Service, repair and maintenance: The MIT410 and MIT420 add additional features required for engineers working on more demanding applications. Functions such as PI and DAR, capacitance measurement and higher insulation range increase the suitability for applications such as: Manufacturing/production testing Panel building Railway and other transportation Motor testing Cable inspection/quality control Street lighting maintenance Avionics ground testing and maintenance Military applications MIT400 Series Industrial Insulation Testers Industrial Insulation Voltage range 400 410 420 Special Apps 430 10-100 V variable (2 G - 20 G) 50 V 100 V 250 V 500 V 1000 V Insulation range 40X 20 G 100 G 200 G 200 G 2-20 G Leakage current display 0.01 to 100 Variable current limit. 200 mA/20 mA Fast buzzer- selectable threshold k range to 999 k Live circuit warning at 50 V Default voltmeter TRMS measurement to 600 V INS test voltage display Continuity measurement Other functions and features Frequency Hz - 40 to 400 Hz Capacitance (0.1 nf to 10 F) Backlight Battery condition display Insulation Timed - PI - DAR Tests Test button plus lock button Limit alarm pass band on INS Auto power down Other functions and features Result storage Bluetooth downloading Included accessories Red/black silicone lead set with clips Protective rubber boot Remote switch probe Calibration certificate with product Batteries 3 Year warranty MIT400 Series Industrial Insulation Testers Variable limit 1 , 2 , 5 , 10 , 20 Buzzer: SPECIFICATION All quoted accuracies are at +20C. Insulation Nominal test voltages MIT400 250 V, 500 V, 1000 V MIT410, 420,430 50 V, 100 V, 250 V, 500 V, 1000 V MIT40X 10 V to 100 V variable (1 V increments) Insulation resistance range MIT400 20 G MIT410 100 G MIT420, 430 200 G MIT40X 200 G 3% 3% 3% 3% 3% 3% Analogue range: 1 G full scale 2 digits 0.2% per G 2 digits 0.4% per G 2 digits 0.8% per G 2 digits 2.0% per G 2 digits 4.0% per G 2 digits 2.0% per 100 M Short Circuit Current: Terminal voltage: 1 mA 0.2 mA -0% +20% 1 V Test Current on load: 1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max. EN61557 Operating range: 0,10 M to 1,00 G Leakage current range 10 A 2000 A Leakage current: 10% 3 digits Voltage display: 3% 3 digits 0.5% of rated voltage Polarisation Index (PI): 10 min / 1minute ratio Dielectric Absorption Ratio (DAR): 60 sec / 30 sec ratio Notes: (1) All ranges measure from 0,00 M upwards. (2) Above specifications only apply when high quality silicone leads are being used. Continuity Measurement: Accuracy: Open circuit voltage: Short circuit current: 0.01 k to 1000 k (0 to 1 M on analogue scale) 3% 2 digits up to 50 k then 5% 2 digits 5 V 1 V 1.5 mA 0.2 mA Voltage range 0 to 600 V d.c. 2% 2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) 2% 2 digits 0 to 1000 V on Analogue scale Unspecified input level 0 - 10 mV (40 to 400 Hz) Range Full Scale Accuracy All ranges 2% 2 digits up to 100 M. Then: 1000 volts 500 volts. 250 volts. 100 volts. 50 volts. 10 volts Resistance Measurement: For non-sinusoidal waveforms additional specification apply: 3% 2 digits 101 mV to 600 V TRMS and 8% 2 digits 10 mV to 100 mV TRMS Default Voltmeter: Operates at >25 V a.c. or d.c. on any range except OFF Frequency: 40-450 Hz (40 Hz - 99.9 Hz) 0.5% 1 digit (100 Hz to 450 Hz) Capacitance measurement MIT420, MIT430 Measurement range: Accuracy: 100 pF to 10 F 5.0% 2 digits Distance by capacitance: MIT420, MIT430 Arithmetic conversion from capacitance measurement on Default capacitance measurement: 50nF/km Capacitance range: 40 nF/km to 60 nF/km Result storage Capacity: Download: Bluetooth Class: Range: >1000 test results Bluetooth wireless Class II up to 10 m Power Supply: 5 x 1,5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 M 0,01 to 99,9 (0 to 100 on analogue scale) 2% 2 digits (0 to 100 ) 5 V 1 V Dimensions Instrument: Test current: 205 mA (5 mA) (0.01 to 9.99 ) 20mA (1 mA ) (10.0 to 99.9 ) Weight Instrument only: 590 gms, 775 gms with boot (20.73 oz. 27.22 oz.) Instrument plus case: 1.75kg (3.86 lb) Zero offset at probe tips: Lead resistance zeroing: 0,10 typical Up to 9.99 Accuracy: Open circuit voltage: 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.) Instrument + case: 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.) MIT400 CATIV Industrial Insulation Testers Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted. Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied. E.M.C. In accordance with IEC 61326 including amendment No.1 Temperature effects Temperature coefficient: <0,1% per C up to 1 G Environmental Operating range: Operating humidity: -20 to +55C 95% RH at 0C to +35C, 70% RH @ +35C to +55C -30C to +80C +20C 2000 m Storage temperature range: Calibration Temperature: Maximum altitude: Dust and water protection: IP54 Protected against dust and splashing water The Bluetooth word mark and logo are owned by the Bluetooth SIG, Inc. and any use of such marks by Megger is under license. ORDERING INFORMATION Item (Qty) Order No. Basic CATIV 600 V with 250 V/500 V/1000 V insulation MIT400-EN As MIT400 + 50 V, 100 V, PI and DAR MIT410-EN As MIT410 + result storage and recall MIT420-EN Bluetooth downloading version of MIT420 MIT430-EN Special selectable voltage 10-100 V MIT40X-EN Included accessories Hard case Test leads: 2 wire lead set to CAT IV 600 V, consisting of : 1 x Red lead 1.25m complete with probe 1 x Black lead 1.25m complete with probe UK Archcliffe Road Dover CT17 9EN England T +44 (0) 1304 502101 F +44 (0) 1304 207342 UKsales@megger.com UNITED STATES 4271 Bronze Way Dallas TX 75237-1088 USA T 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 USsales@megger.com Item (Qty) Order No. 1 x Red croc clip 1 x Black croc clip 1 x instrument rubber boot 1 x Calibration certificate (not included with MIT40X) 1 x Switched probe (not included with MIT400 and MIT40X) Owners information CD Accessories Replacement lead set 6220-813 SP5 remote switch probe 6220-812 Rubber boot with stand 6231-802 Hard case 5410-420 OTHER TECHNICAL SALES OFFICES Norristown USA, Sydney AUSTRALIA, Toronto CANADA, Trappes FRANCE, Kingdom of BAHRAIN, Mumbai INDIA, Johannesburg SOUTH AFRICA and Conjure THAILAND. Registered to ISO 9001:2000 Cert. no. Q 09290 Registered to ISO 14001-1996 Cert. no. EMS 61597 MIT400_410_420_430_40X_DS_en_V05 www.megger.com Megger is a registered trademark