SPECIFICATION
120W Single Output Switching Power Supply NPF-120D series
File Name:NPF-120D-SPEC 2015-05-08
SPECIFICATION
MODEL
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.4
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
<0.25mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge 2KV), criteria A
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
233.9K hrs min. MIL-HDBK-217F (25 )℃
191*63*37.5mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel
capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
Protection type : Shut down o/p voltage, re-power on to recover
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
500ms, 80ms at 95% load 230VAC / 115VAC
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
1.3A / 115VAC 0.65A / 230VAC 0.55A / 277VAC
EMC IMMUNITY
EMC EMISSION
COLD START60A(twidth=520 s measured at 50% Ipeak) at 230VAC
μ
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
-40 ~ +70 (Refer to "Derating Curve")℃
17.5 ~ 21V15 ~ 17V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 54 ~ 60V
46 ~ 54V 59 ~ 66V
88%87.5% 89% 89.5% 89% 89.5% 90%89.5% 90%
±4.0%±4.0% ±4.0% ±4.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0%
±0.5%±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.5%±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
15V12V
NPF-120D-15
NPF-120D-12
NPF-120D-20
NPF-120D-24
NPF-120D-30
NPF-120D-36
NPF-120D-42
NPF-120D-48
NPF-120D-54
20V 24V 30V 36V 48V
8A10A 6A 5A 3.4A 2.5A
120W120W 120W 120W 120W 122.4W 120W
150mVp-p150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p
54V
2.3A
124.2W
350mVp-p
42V
2.9A
121.8W
250mVp-p
9 ~ 15V7.2 ~ 12V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 28.8 ~ 48V 32.4 ~ 54V
25.2 ~ 42V
4A
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
0.97Kg; 15pcs/15.6Kg/0.78CUFT
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
UL8750, CSA C22.2 No. 250. , ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved; Design refer to EN60335-113-12
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed