Fluke Ti5xFT and Ti4xFT FlexCam Thermal Imagers (R) Technical Data The experts' choice for problem solving and preventive/predictive maintenance Features Ti55FT High resolution, low noise VOx detector for high quality images Temperature range to cover broad industrial applications Ti50FT Ti45FT 320 x 240 -20 C to +600 C (-4 F to 1112 F) High temperature option Ti40FT 160 x 120 -20 C to +350 C (-4 F to 662 F) - -20 C to +600 C (-4 F to 1112 F) -20 C to +350 C (-4 F to 662 F) 1200 C (2192 F) - 0.05 C at 30 C (50 mK) 0.07 C at 30 C (70 mK) 0.08 C at 30 C (80 mK) 0.09 C at 30 C (90 mK) 180 articulating flexible lens to view images in every situation * * * * Choice of 3 interchangeable lenses to cover every application* * * * * Large 5 inch high contrast color LCD for a clear picture independent of lighting conditions * * * * Fully radiometric for detailed temperature analysis and tracking * * * * SmartFocus for best image quality and accurate temperature measurements * * * * Windows CE based menu structure for ease of use * * * * Personalized instrument set-up for multiple person use * * * * CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data * * * * SmartViewTM reporting and analysis software included * * * * AutoCapture for making intermittent problems visible * * * * * * * * * * * * * * * * * * * * High thermal sensitivity for viewing even the smallest temperature differences On-board analysis functions User defined text annotations for simplified reporting Built-in visible (visual) light camera IR-Fusion blending thermal and visible light images IR/Visible Alarm function Laser pointer for easy targeting Flash and torch light for high quality images in dark environments * * *10 mm and 54 mm lenses are optional and are only available at time of initial order. * * The Fluke Ti5xFT and Ti4xFT models feature everything needed for virtually any thermography task. All Fluke FlexCam Thermal Imagers come standard with the patent-pending Fluke IR-Fusion(R) Technology fusing visual (visible light) images with infrared images. SmartViewTM IR analysis and reporting software is included with each purchase along with free software upgrades for the life of your product. The Ti4xFT models feature 160 x 120 detectors and temperature sensitivity (NETD) down to 0.08 C (80 mK) in the higher end model. The Ti5xFT models feature 320 x 240 detectors and temperature sensitivity (NETD) down to 0.05 C (50 mK) in the higher end model. Choose Fluke FlexCam Thermal Imagers when you need industry leading thermal sensitivity for high resolution, ultra high-quality images. Typical applications: * Troubleshooting--Pinpointing the location of specific problems in equipment and systems. * Preventive/predictive maintenance-- Identify electrical and mechanical problems before they cause failure. * Industrial maintenance--Check whether repairs have been performed correctly. * Process monitoring--Real-time observation to ensure efficient and safe operations. * Quality control--Examine prototypes and refine thermal management designs. * Research and development--Quantify heat patterns to improve product designs (Ti5XFT models). * Electronic design--Circuit board analysis (Ti5XFT models). Detailed specifications Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT Imaging performance 23 horizontal x 17 vertical Field of view (FOV)* 1.30 mrad Spatial resolution (IFOV)* 2.60 mrad 0.15 m (5.9 in) Min focus distance* Thermal sensitivity (NETD) 0.05 C at 30 C (50 mK) 0.07 C at 30 C (70 mK) 0.08 C at 30 C (80mK) 0.09 C at 30 C (90mK) 60 Hz/60 Hz Detector data acquisition/ image frequency 30 Hz/30 Hz SmartFocus; one finger continuous focus (manual) Focus 2x, 4x, 8x IR digital zoom 2x 2x 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer Detector type -- 160 x 120 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer 8 m to 14 m Spectral band Automatic full time enhanced Digital image enhancement On camera operating modes Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture 1280 x 1024 pixels, full color Visible light camera Visible light digital zoom Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture 2x, 4x 2x 2x -- Temperature measurement Calibrated temperature range -20 C to 600 C (-4 F to 1112 F) in three ranges -20 C to 350 C (-4 F to 662 F) in two ranges -20 C to 600 C (-4 F to 1112 F) in three ranges -20 C to 350 C (-4 F to 662 F) in two ranges Range one =-20 C to 100 C (-4 F to 212 F) Range one = -20 C to 100 C (-4 F to 212 F) Range one = -20 C to 100 C (-4 F to 212 F) Range one = -20 C to 100 C (-4 F to 212 F) Range two = -20 C to 350 C (32 F to 662 F) Range two = -20 C to 350 C (32 F to 662 F) Range two = -20 C to 350 C (32 F to 662 F) Range two = -20 C to 350 C (32 F to 662 F) Range three = 250 C to 600 C (482 F to 1112 F) Range three = 250 C to 600 C (482 F to 1112 F) Optional--High temperature -- -- -- Up to 1200 C (2192 F) Range 4 = 500 C to 1200 C (932 F to 2192 F) 2 C or 2 % (whichever is greater) Accuracy Measurement modes Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below Centerpoint, center box (area min/max, average) Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below Centerpoint, center box (area min/max, average) 0.1 to 1.0 (0.01 increments) Emissivity correction Image presentation 13 cm (5 in) diagonal large high-resolution digital display Digital display LCD backlight Sunlight readable color LCD Video output RS170 EIA/NTSC or CCIR/PAL composite video Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted Palettes Optical lenses 54 mm telephoto lens High precision Germanium lens Field of view (FOV): 9 horizontal x 6 vertical Spatial resolution (IFOV): 0.47 mrad Spatial resolution (IFOV): 0.94 mrad Min focus distance: 0.6 m (1.97 ft) 2 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion General specifications Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT Optical lenses (continued) High precision Germanium lens Field of view (FOV): 42 horizontal x 32 vertical 10.5 mm wide angle lens Spatial resolution (IFOV): 2.45 mrad Spatial resolution (IFOV): 4.9 mrad Min focus distance: 0.3 m (0.98 ft) Image and data storage Compact flash card stores over 1000 IR images (1 GB card standard) Storage medium 14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff; Data formats: comma separated (csv), tab separated (txt). File formats supported Interface and software Interface Compact flash card reader included Software SmartView; Full analysis and reporting software included Laser Class II Classification Laser dot visible on screen when blending thermal and visible image Laser targeting Controls and adjustments Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low) Set-up controls Level, span, auto adjust (continuous/manual) Image controls Battery status, target emissivity, background temperature and realtime clock On-screen indicators Power Li-Ion smart battery, rechargeable, field-replaceable (two included) Battery type Two hours continuous operation (per battery) Battery operating time Two bay intelligent charger powered via ac outlet Battery charging AC adapter 110/220 V ac, 50/60 Hz Continuous ac operation -- AC adapter 110/220 V ac, 50/60 Hz -- Automatic shutdown and sleep modes (user specified) Power saving Environmental and mechanical design -10 C to +50 C (14 F to 122 F) Operating temperature -40 C to +70 C (-40 F to 158 F) Storage temperature Operating and storage 10 % to 95 %, non-condensing Relative humidity Water and dust resistant IP54 Weight (including batteries) 1.95 kg (4.3 lb) Camera size (H x W x D) 162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in) Other Two-years Warranty *Standard 20 mm Germanium lens Fluke. Keeping your world up and running.(R) Ordering information FLK-Ti40FT-20 FLK-Ti45FT-20 FLK-Ti50FT-20 FLK-Ti55FT-20 IR IR IR IR FlexCam FlexCam FlexCam FlexCam Thermal Thermal Thermal Thermal Imager Imager Imager Imager with with with with IR-Fusion IR-Fusion IR-Fusion IR-Fusion Included with product Heavy duty carrying case, 2 rechargeable battery packs, battery charger, ac adapter (for Ti45FT and Ti55FT only), video cable, 512 MB compact flash card, compact flash card reader and USB cable, PCMCIA compact flash card reader, neck strap, printed getting started guide, SmartView reporting and analysis, software on CD, complete user manual on CD 3 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion Fluke Corporation PO Box 9090, Everett, WA U.S.A. 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2007-2009 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 4/2009 2674273 D-EN-N Rev D Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: TI55FT-10/20/54