1
Power entry modules without line filter DF11
https://www.schurter.com /PG05
Connectors
IEC Appliance Inlet C14 or C18 with recessed Circuit Breaker TA45
Approvals and Compliances
C14
70° C
C18
70° C
Description
- Panel Mount :
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions :
Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
- All single elements are already wired
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
- Unwired versions
- Other rocker marking
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version with line filter DF12
Substitute for type 6145
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 1 - 15 A / 250 VAC; 60 Hz
Dielectric Strength > 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
Allowable Operation Tempe-
rature
-10 °C to 55 °C
IP-Protection from front side IP 40 acc. to IEC 60529
Insulation cover Suitable for appliances with protection
class I or II acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness S Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1/1.5/2/2.5/3 mm
Material: Housing Thermoplastic, black, UL 94V-0
appliance inlet/-outlet C14 / C18 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In 3A/240VAC : 300A
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
2
Power entry modules without line filter
DF11 https://www.schurter.com /PG05
Connectors
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DF11
Approval Logo Certificates Certification Body Description
VDE Approvals VDE Certificate Number: 40011305
UL Approvals UL UL File Number: E96454
Product standards
Product standards that are referenced
Organization Design Standard Description
Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Application standards
Application standards where the product can be used
Organization Design Standard Description
Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Compliances
The product complies with following Guide Lines
Identification Details Initiator Description
CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS SCHURTER AG EU Directive RoHS 2011/65/EU
China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
3
Power entry modules without line filter DF11
https://www.schurter.com /PG05
Connectors
Dimensions [mm]
Screw-on Version
R2.8
R4.7
R6
28.2 29
R 2.55
ø 3.6/M3
R 2.95
4.5
82.5
73.5 ±0.10
±0.05
±0.10
±0.05
±0.10
76.7
9.7 37.1
91.5
82.5
32.5
28.7
9.15 73.2
4.5
Ø 3.3
Ø 6.4
2.3
41.710.6
4.827.9
0.8
9.4
9.45
72.7
Snap-in version
R2.8
R4.7
28.2 29
R 2.55
R 2.95
73.5 ±0.10
±0.05
±0.10
76.7
9.7 37.1
77
32.5
28.7
1.9 73.2
2.3
41.710.6
4.827.9
S ±0.1
2.15
9.45
72.7
* --- Version TA45 with undervoltage release
4
Power entry modules without line filter
DF11 https://www.schurter.com /PG05
Connectors
Diagrams
1)
2)
L' P1
N' P
2
N
L
PE PE'
1) Line
2) Load
5
Power entry modules without line filter DF11
https://www.schurter.com /PG05
Connectors
ABT W F 150 C0
Colours
Switch front Rocker
W black white
B black black
6 black orange transp.
F embossed / Relief
H printed / bedruckt white / weiss
K printed / bedruckt black / schwarz
L printed / bedruckt white / weiss
Surface Illustration Colour of print
Rocker legend
l
O
ON
OFF
ON
OFF
l
O
M printed black
P printed white
R printed black
Surface Illustration Colour of print
Rated current circuit breaker of equipment
Without release: code C0
Undervoltage release Remote trip release
UEZACode
Rated
voltage Un
2
3
4
240 V AC
230 V AC
120 V AC
l
O
OI
OI
Position of the rocker legend
e.g F
In Code
0,1 J01
0,2 J02
0,3 J03
0,4 J04
0,5 J05
0,6 J06
0,7 J07
0,8 J08
0,9 J09
1,0 J10
1,1 J11
1,2 J12
In Code
1,3 J13
1,4 J14
1,5 J15
1,6 J16
1,7 J17
1,8 J18
1,9 J19
2,0 J20
2,1 J21
2,2 J22
2,3 J23
2,5 J25
In Code
2,8 J28
3,0 030
3,5 035
4,0 040
4,5 045
5,0 050
6,0 060
6,5 065
7,0 070
7,5 075
8,0 080
9,0 090
In Code
10,0 100
11,0 110
12,0 120
13,0 130
14,0 140
15,0 150
20,0 200
Table 1 Selection for type TA45
Order example
Circuit Breaker of Equipment
2-pole, rocker actuated
Quick connect terminal
Other types on request
Without illumination
With illumination 220…240 V
110…120 V
Diagram
Thermal overload protection 1-pole 2-pole
ABT ABD
A12 A32
A14 A34
P2 P1
63
43
P2 P1
}
P2 P1
U<
P2 P1
b
U<
P2 P1
ba
U<
P2 P1
c
6
Power entry modules without line filter
DF11 https://www.schurter.com /PG05
Connectors
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
Tripping characteristics
In >_ 3… <_ 15 A
Effect of ambient temperature 1)
The unit is calibrated for an ambient temperature of +23 °C. To
deter mine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
* Ambient temperature [°C] Correction factor
–10 0,89
5 0,91
0 0,92
+23 1,00
+30 1,03
+40 1,08
+55 1,16
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
Optional Variants
0 standard
9 V-Lock
Colour
0 black
Mounting
0 Screw mounting
1 Snap-in mounting s = 1.0 mm
2 Snap-in mounting s = 1.5 mm
3 Snap-in mounting s = 2.0 mm
4 Snap-in mounting s = 2.5 mm
5 Snap-in mounting s = 3.0 mm
Terminal PE
0 without terminal (PCII)
1 Quick-connect terminal 6.3x0.8 mm
Terminal N
1 Quick-connect terminals 6.3x0.8mm, without connection to TA45
3 connection to TA45 non insulated
Terminal L
1 Quick-connect terminals 6.3x0.8mm, without connection to TA45
3 connection to TA45 non insulated
1) Example
Rated current at +23 °C 6,0 A
Ambient temperature +40 °C
Correction factor 1,08
Chosen rated current at
+ 40 °C ambient temperature 6 A x 1,08 = 6,5 A
10’000
60
2000
1000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In ]
10854321,32
Tripping time
Type TA45
Rated current In < 3 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
10’000
60
2’000
1’000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
[ x In ]
10854321,32
Type TA45
Rated current I > 3...
< 15 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
Multiple of rated current
Tripping time
n
Configuratorcode (example)
DF11 - ABTWF150C0 - 000 - 111 - 009
Order code TA 45
(2-pole rocker-switch
without accessories)
Type
see table 1
7
Power entry modules without line filter DF11
https://www.schurter.com /PG05
Connectors
Packaging unit 20 Pcs
Accessories
Description
Assorted Covers
Rear Cover
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091
Appliance Outlet further types to DF11
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012
Connector further types to DF11 ...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS
Power Cord further types to DF11
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
01.12.2017
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schurter:
DF11.1927.0013.01 DF11.3938.0010.019