For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 47
Low Voltage Supplementary Fuses
Low Voltage
Supplementary
Fuses
Specifications
Class: Supplemental
Description: Time-delay,
pin indication fuse.
Dimensions: 13⁄32” x 1 1⁄2”
(10.3 x 38.1mm).
Construction: Fiber tube
Ratings:
Volts — 250Vac (1⁄10-8⁄10A)
— 125Vac (1-15A)
— 32V (20-30A)
Amps — 1⁄10-30A
IR — 35A (1⁄10-8⁄10A @ 250Vac)
— 10,000A (1⁄10-15A @ 125Vac)
— 1000A (20-30A @ 32V)
Agency Information: CE, Std. 248-
14, UL Listed 1⁄10-8⁄10A, IR 35A@ 250V,
IR 10kA@ 125V , 1-15A, IR 10kA@
125V, Guide JDYX, File 19180, CSA
Certified, 0-8⁄10A/250V, 1-10A/125V,
Class 1422-01, File 53787.
Features and Benefits
• FNA has a pin indicator providing
visual identification of failed circuits,
resulting in reduced circuit downtime.
• Time-delay response allows close
sizing on control transformers and
relays
Typical Applications
• Control Circuits
• Electronic Circuits
Catalog Numbers (Amps)
FNA-1⁄10 FNA-8⁄10 FNA-2 1⁄2FNA-6 1⁄4
FNA-1⁄8FNA-1 FNA-2 8⁄10 FNA-7
FNA-15⁄100 FNA-1 1⁄8FNA-3 FNA-8
FNA-2⁄10 FNA-1 1⁄4FNA-3 2⁄10 FNA-9
FNA-1⁄4FNA-1 4⁄10 FNA-3 1⁄2FNA-10
FNA-3⁄10 FNA-1 1⁄2FNA-4 FNA-12*
FNA-4⁄10 FNA-1 6⁄10 FNA-4 1⁄2FNA-15*
FNA-1⁄2FNA-1 8⁄10 FNA-5 FNA-20*
FNA-6⁄10 FNA-2 FNA-5 6⁄10 FNA-25*
FNA-3⁄4FNA-2 1⁄4FNA-6 FNA-30
*12-30A versions are dual-tube construction
MIC & MIN
Specifications
Class: Supplemental
Description: Fast-
acting, pin indication
fuse.
Dimensions:
13⁄32” x 1 1⁄2” (10.3 x
38.1mm) 5AG.
Construction:
Fiber tube
Ratings:
Volts — 250Vac (1-15A)
— 32V (20-30A)
Amps — 1-30A
IR — 35A (1A @250Vac)
— 100A (2-3A @250Vac)
— 200A (5-10A @250Vac)
— 750A (15A @250Vac)
— 10,000A (20-30A @32V)
— 35A (1A @250Vac)
Agency Information: CE, Std. 248-14,
MIC—0-15A UL Listed, Guide JDYX,
File E19180, MIN—1-5A CSA Certified,
Class 1422-01, File 53787.
Features and Benefits
•Type MIN has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster trouble
shooting (reduced circuit downtime).
•Type MIC has silver-plated pin transmit-
ting an electrical signal indicating
location of a failed circuit, resulting in
faster troubleshooting (reduced circuit
downtime).
Typical Applications
•Control Circuits
•PLC Circuits
•Electronic Circuits
MIC Catalog Numbers (Amps)
MIC-1 MIC-5 MIC-20
MIC-2 MIC-10 MIC-25
MIC-3 MIC-15 MIC-30
MIC - (1-15)UL Listed 125Vac / IR = 10kA
MIN Catalog Numbers (Amps)
MIN-1 MIN-5 MIN-20
MIN-2 MIN-10 MIN-25N
Specifications
Class: Supplemental
Description: Fast-acting, pin
indication fuse.
Dimensions: 1⁄4” x 1 1⁄4”
(6.6 x 31.7mm) 3AG.
Construction: Fiber tube
Ratings:
Volts — See Agency Info below
Amps — 1⁄2-15A
IR — See Agency Info below
Agency Information: CE, Std. 248-
14, UL Listed, 0-5A/125Vac, 10,000
AIC, Guide JDYX, File E19180, UL
Recognized, 6A/125Vac, 1000AIC
8-15A/50Vac/dc, 300 AIC Guide
JDYX2, File E19180, CSA Certified:
0-5A/125Vac, 10,000 AIC Class
1422-01, File 53787.
Features and Benefits
• Type GBA has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster
troubleshooting (reduced circuit
downtime).
• Type GLD has an plated pin to
activate transmitting a electrical
signal to indicate the location of
opened circuits, resulting in reduced
downtime.
Typical Applications
• Control Circuits
• Electronic Circuits
GLD Catalog Numbers (Amps)
GLD-1⁄2GLD-2 GLD-6
GLD-3⁄4GLD-3 GLD-10
GLD-1 GLD-4 GLD-12
GLD-1 1⁄2GLD-5 GLD-15
GBA Catalog Numbers (Amps)
GBA-1⁄2GBA-2 GBA-8
GBA-3⁄4GBA-3 GBA-10
GBA-1 GBA-4 GBA-15
GBA-1 1⁄2GBA-5
Pin indication Fuses
Data Sheet: 2029
Data Sheet: 2047
Data Sheet: 2012
GBA
GLD
FNA
Recommended fuse blocks/fuse
holders for 1⁄4”x 1
1⁄4” indicating fuses
• Page 41
Recommended signal block for
13⁄32”x 1
1⁄2” indicating fuses
• Page 41
Recommended signal block for
13⁄32”x 1
1⁄2” indicating fuses
• Page 41