DFC25 Triple-Output DC-DC Series Data Sheet Features * RoHS lead solder exemption compliant * Up to 25 watts with triple outputs * +3.3V or +5V main outputs * Remote On/Off * Common and differential mode input filters * Main output trim * Efficiencies to 81% * Operation from -25C up to 85C * 700/1544V isolation * Two-year warranty * UL/CSA/TUV pending Description The DFC25 Series dc-dc converter provides three output voltages from a single 12, 24, or 48 volt nominal input for industrial and datacom equipment. Available output power ranges up to 25 watts. Excellent noise performance is attained via an aluminum case, toroidal magnetics, and double shielded transformers. Common mode and differential mode input filtering is integral to the design. Selected models provides 1544 volts isolation from input to output. The input and output sections of the DFC25 Series are protected from overvoltage transients via internal circuitry. Same voltage single output units of the DFC25 family may be connected in parallel to achieve additional output current. Selection Chart - Up to 25 Watts Output Power Input Range VDC Min Max Model DFC25E24T3.3/15 DFC25E24T5/12 DFC25E24T5/15 DFC25E48T3.3/12 DFC25E48T5/12 DFC25E48T5/15 18 18 18 36 36 36 36 36 36 72 72 72 Output VDC Nominal Output mA MAX 3.3, 15 5.0, 12 5.0, 15 3.3, 12 5.0, 12 5.0, 15 5000, 800 5000, 1000 5000, 800 5000, 1000 5000, 1000 5000, 800 BOTTOM VIEW SIDE VIEW 0.040 (1.02) DIA 9 PLACES 2.50 (63.5) 9 2.75 (70.0) 8 7 6 5 3.00 (76.2) MIN MIN 700 1544 Volts TYP 700 pF ON Logic Level or Pin Open MIN 2.5 Volts Off Logic Level or Tie to -Input MAX 0.7 Volts Converter Idle Current TYP 10 mA Input Resistance TYP 40 k Programming Range MIN 10 % Case Operating Range (2) MIN MAX -25 +60 C Case Functional Range MIN MAX -40 +105 C Storage Range MIN MAX -45 +105 C Thermal Impedance TYP 10 C/Watt MTBF (Calculated) TYP 1,000,000 Hours Unit Weight TYP 2.6/71 oz/gm Input to Output Capacitance Remote ON/OFF Output Trim Function Environmental General JAN 26, 2006 revised to MAR 20, 2007 PIN CONNECTIONS PIN NUMBER PIN OUT 1 -INPUT 2 +INPUT 3 N/C 4 ON/OFF 5 TRIM 6 +3.3V OR +5V 7 COMMON 8 +12V OR +15V 9 -12V OR -15V 0.43 (11.0) 4 0.000 2 0.38 (9.65) 1 2.05 (52.1) Isolation Voltage Input to Output 12V, 24V Input 48V Input 10A Leakage 0.00 Isolation (3) 0.25 (6.3) 0.00 1.65 (42.0) Units 1.25 (31.8) All Models 0.45 (11.4) General Specifications (1) 0.85 (21.6) Model numbers highlighted in yellow or shaded are not recommended for new designs. NOTE: All pins are 0.040" diameter brass with tin plating. Mechanical tolerances unless otherwise noted: X.XX dimensions: 0.020 inches X.XXX dimensions: 0.005 inches NOTES (1) All parameters measured at 25 C, nominal input voltage, and full rated load unless otherwise noted. Refer to the Technical Reference Section for the definition of terms, measurement circuits, and other information. (2) Derate linearly to 0 Watts at 105 C ambient. Operation to +70 C ambient with externally supplied forced air cooling, 100 LFM. Consult the factory for -40 C operation. (3) Case is tied to -Input, Pin 1. Page 1 of 3 www.power-one.com DFC25 Triple-Output DC-DC Series Data Sheet Input Parameters (1) Model DFC25E24T3.3/15 DFC25E24T5/12 DFC25E24T5/15 DFC25E48T3.3/12 DFC25E48T5/12 DFC25E48T5/15 Units Reflected Ripple (2) TYP 230 230 230 150 150 150 mAPP Input Current Full Load No Load TYP TYP 1780 10 1563 10 1563 10 890 10 781 10 781 10 mA Inrush Current (5) MAX 50 50 50 50 50 50 APK Efficiency TYP 78 80 80 78 80 80 % Switching Frequency TYP 150 150 150 150 150 150 kHz Maximum Input Overvoltage, 100ms Maximum MAX 45 45 45 85 85 85 VDC Turn-on Time, 1% Output Error TYP 10 10 10 10 10 10 mS Output Parameters (1) Model DFC25EXXT3.3/XX DFC25EXXT5/XX DFC25EXXTX/12 DFC25EXXTX/15 Output (8) V1 V1 V2,V3 V2,V3 Output Voltage 3.3 5 12 15 VDC Output Voltage Accuracy MIN TYP MAX 3.27 3.30 3.33 5.05 5.10 5.15 11.88 12.00 12.12 14.85 15.00 15.15 VDC Rated Load Range MIN MAX 0.5 5.0 0.5 5.0 0.0 1.0 0.0 0.8 A Load Regulation 25% Load - Max Load TYP 1.0 1.0 8.0 8.0 % Line Regulation Vin = Min-Max VDC TYP 0.2 0.2 3.0 3.0 % Cross Regulation 25% Load - Max Load (6) TYP 3.0 3.0 8.0 8.0 % Transient Response 25% Load Step (7) TYP 2 2 2 2 % Short Term Stability (3) TYP <0.05 <0.05 <0.05 <0.05 %/24Hrs Long Term Stability TYP <0.1 <0.1 <0.1 <0.1 %/kHrs Input Ripple Rejection (4) TYP >40 >40 >40 >40 dB Noise, Peak - Peak (2) TYP 75 75 120 150 mVPP Temperature Coefficient TYP 100 100 300 300 ppm/C Short Circuit Protection from +OUT to -OUT Continuous, Current Limit Protection NOTES (1) All All parameters measured at Tc=25C, nominal input voltage and full rated load unless otherwise noted. Refer to the Reference Section for the definition of terms, measurement circuits and other information. (2) Noise is measured per the Technical Reference Section. Measurement bandwidth is 0-20 MHz for peak-peak measurements, 10 kHz to 1 MHz for RMS measurements. Output noise is measured with a 0.01F/100V ceramic capacitor in parallel with a 1F/35V Tantalum capacitor, 1 inch from the output pins to simulate standard PCB decoupling capacitance. (3) Short term stability is specified after a 30 minute warm-up at full load, constant line and recording the drift over a 24 hour period. (4) The transient response is specified as the time required to settle from a 50 to 75% step load change (rise time of step = 2Sec) to a 1% error band. (5) Per ETSI-300-132 (6) Change to main channel output for a 25% to 100% change on dual outputs or change on dual channel outputs due to a 25% to 100% change on the main channel output. (7) Recovery to within 1% in less than 1 millisecond after transient has been applied. (8) V3 is defined as the minus, or negative output. Values in the chart are shown as positive for V2, and can be assumed negative for V3. JAN 26, 2006 revised to MAR 20, 2007 Units DFC25 SERIES APPLICATION NOTES: External Capacitance Requirements A low ESR external capacitance is required for operation of the DFC25 Series. For maximum performance, it is recommended that the DFC25 Series use a capacitor of sufficient ripple current capacity connected across the input pins, especially if a capacitive input source is farther than 1" from the converter. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.09 Ohms at 200 kHz is required. External output capacitance is not required for operation, however it is recommended that 1F to 10F of Tantalum and 0.001 to 0.1F ceramic capacitance be selected for each output to reduce system noise. Additional output capacitance may be added for increased filtering, but should not exceed 400F. Remote ON/OFF Operation The remote ON/OFF pin may be left floating if this function is not used. It is recommended to drive this pin with TTL compatible circuitry. When the ON/OFF pin is pulled low with respect to the -INPUT, the converter is placed in a low power drain state. The input capacitors are kept fully charged in the OFF mode. For proper operation, this input may be driven from a logic gate directly. The ON/OFF pin should never be pulled more than 0.3 volts below -INPUT or have a voltage greater than +6 volts applied. Page 2 of 3 www.power-one.com DFC25 Triple-Output DC-DC Series Data Sheet NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JAN 26, 2006 revised to MAR 20, 2007 Page 3 of 3 www.power-one.com