©2017 CTS® Corporation. Information/product(s) subject to change. No warranty that product(s) will meet the stated specifications for customer specific applications or test
equipment. Visit www.ctscorp.com for list of applicable patent(s), more information, or to request a quote.
DOC# 008-0256-0 Rev. I Page 1 of 6
Model CB3 & CB3LV
HCMOS/TTL Clock Oscillator
Features
Ceramic Surface Mount Package
Fundamental and 3rd Overtone Crystal Designs
Frequency Range 1.0 – 200MHz *
+3.3V and +5.0V Operation
Operating Temperature Range to -40°C to +85°C
Output Enable Standard
Tape and Reel Packaging, EIA-418
Internet of Things [IoT, IIoT]
Microcontrollers and FPGAs
Wireless Communication
Networking Equipment
Data Communications
Computers and Peripherals
Ethernet/GbE/SyncE
Portable Devices
Test and Measurement
CTS Model CB3 and CB3LV are low cost, low voltage clock oscillators supporting HCMOS output. Employing the
latest IC technology, CB3/CB3LV have excellent stability and low phase jitter performance.
Model
CB3 - -
Code Code
LV C
Blank I
Code Code
6
5
7
3
2
Notes:
1]
2]
3]
4]
This product is specified for use only in standard commercial applications. Supplier disclaims all express and implied warranties and
liability in connection with any use of this product in any non-commercial applications or in any application that may expose the
product to conditions that are outside of the tolerances provided in its specification.
[Ex. 3.579545MHz = 3M57954, 14.31818MHz = 14M318180, 25MHz = 25M000000, 125MHz = 125M000000]
[Ex. part numbers - CB3LV-3C-25M000000, CB3-3C-14M318180]
Consult factory for availability of 6I Stability/Temperature combination.
These stabilities are not recommended for new designs.
Frequency is recorded with 1, 2 or 3 leading significant digits before and 6 significant digits [including zeroes] after the "M".
CTS Distributors may add a -T or -1 at the end of the part number to indicate Tape and Reel packaging.
Not all performance combinations and frequencies may be available.
Contact your local CTS Representative or CTS Customer Service for availability.
Part Dimensions:
7.0 × 5.0 × 1.8mm • 171.497mg
* See Page 6 for common frequencies.
Check with factory for availability of frequencies not listed.
©2017 CTS® Corporation. Information/product(s) subject to change. No warranty that product(s) will meet the stated specifications for customer specific applications or test
equipment. Visit www.ctscorp.com for list of applicable patent(s), more information, or to request a quote.
Model CB3 & CB3LV
HCMOS/TTL Clock Oscillator
DOC# 008-0256-0 Rev. I Page 2 of 6
Electrical Specifications
Operating Conditions
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNIT
Maximum Supply Voltage
2.97 3.3 3.63
4.50 5.0 5.50
Frequency Range @ Tested load for typical values
1.0MHz to 20MHz @ CL = 30pF -10 25
20.001MHz to 80MHz @ CL = 30pF -30 50
80.001MHz to 107MHz @ CL = 15pF -40 70
1.0MHz to 20MHz @ CL = 15pF - 7 12
20.001MHz to 80MHz @ CL = 15pF -20 35
80.001MHz to 200MHz @ CL = 15pF -30 60
1.0MHz to 50MHz -30 50
50.001MHz to 80MHz -15 30
80.001MHz to 200MHz - - 15
Frequency Stability
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNIT
Frequency Stability
[Note 1]
Aging Δf/f25 First Year @ +25°C, nominal VCC -5 ±3 5ppm
Output Parameters
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNIT
Logic '1' Level, CMOS Load 0.9VCC - -
Logic '1 ' Level, TTL Load VCC - 0.6V - -
Logic '0' Level, CMOS Load - - 0.1VCC
Logic '0 ' Level, TTL Load - - 0.4
IOH VOH = +2.2V/+3.9V VCC = +3.0V/+4.5V - - -8, -16
IOL VOL = 0.4V VCC = +3.0V, +4.5V - - +8 , +16
Output Duty Cycle SYM @ 50% Level 45 -55 %
@ 10%/90% Levels, Frequenc y Range @ Tested load for typical values
1.0MHz to 20MHz @ CL = 30pF - 8 10
20.001MHz to 80MHz @ CL = 30pF - 5 8
80.001MHz to 107MHz @ CL = 15pF 2.5 5
1.0MHz to 20MHz @ CL = 15pF 6 8
20.001MHz to 80MHz @ CL = 15pF 3 5
80.001MHz to 200MHz @ CL = 15pF -1.5 3
Start Up Time TSApplication of VCC - 5 10 ms
Rise and Fall Time
[Note 2]
CB3
CB3LV
2.] Parameters are worst case and account for comprehensive range of product specification. Performance may vary by application and must be validated by end user.
1.] Inclusive of initial tolerance at time of shipment, changes in supply voltage, load, temperature and 1st year aging.