SIDC05D60C6
Edited by INFINEON Technologies, AIM PMD D CID CLS, L4531M, Edition 1.1, 10.07.2006
Fast switching diode chip in EMCON 3 -Technology
This chip is used for:
power module
discrete components
FEATURES:
600V EMCON 3 technology 70 µm chip
soft, fast switching
low reverse recovery charge
small temperature coefficient
Applications:
drives
white goods
resonant applications
A
C
Chip Type VR IF Die Size Package
SIDC05D60C6 600V 15A 2.37 x 1.9 mm2 sawn on foil
MECHANICAL PARAMETER:
Raster size 2.37 x 1.9
Area total / active 4.5 / 2.88
Anode pad size 1.95 x 1.48
mm2
Thickness 70 µm
Wafer size 150 mm
Flat position 180 deg
Max. possible chips per wafer 3276 pcs
Passivation frontside Photoimide
Anode metallization 3200 nm AlSiCu
Cathode metallization Ni Ag system
suitable for epoxy and soft solder die bonding
Die bond electrically conductive glue or solder
Wire bond Al, 500µm
Reject ink dot size 0.65mm; max 1.2mm
Recommended storage environment store in original container, in dry nitrogen,
< 6 month at an ambient temperature of 23°C
SIDC05D60C6
Edited by INFINEON Technologies, AIM PMD D CID CLS, L4531M, Edition 1.1, 10.07.2006
Maximum Ratings
Parameter Symbol Condition Value Unit
Repetitive peak reverse voltage VRRM 600 V
Continuous forward current limited by
Tjmax IF
1 )
Maximum repetitive forward current
limited by Tjmax IFRM 30 A
Operating junction and storage
temperature Tj , Tstg -40...+175 °C
1 ) depending on thermal properties of assembly
Static Electrical Characteristics (tested on chip), Tj=25 °C, unless otherwise specified
Value
Parameter Symbol Conditions min. Typ. max. Unit
Reverse leakage current IR VR=600V Tj=25°C 27 µA
Cathode-Anode
breakdown Voltage VBr IR=0.25mA Tj=25°C 600 V
Forward voltage drop VF IF=15A Tj=25°C 1.25 1.6 1.95 V
Dynamic Electrical Characteristics (verified by design/characterization), inductive load
Value 2)
Parameter Symbol Conditions min. Typ. max. Unit
Peak reverse recovery
current IRM
IF=15A
di/dt=1600A/µs
VR=300V
VGE= -15V
Tj = 25 °C
Tj = 125 °C
Tj = 150 °C
23.0
25.0
26.0 A
Recovered charge
Qr
IF=15A
di/dt=1600A/µs
VR=300V
VGE= -15V
Tj = 25 °C
Tj = 125 °C
Tj = 150 °C
0.80
1.40
1.70 µC
Reverse recovery energy
Erec
IF=15A
di/dt=1600A/µs
VR=300V
VGE= -15V
Tj = 25 °C
Tj = 125 °C
Tj = 150 °C
0.16
0.28
0.37 mJ
2) values also influenced by parasitic L- and C- in measurement and package.
SIDC05D60C6
Edited by INFINEON Technologies, AIM PMD D CID CLS, L4531M, Edition 1.1, 10.07.2006
CHIP DRAWING:
SIDC05D60C6
Edited by INFINEON Technologies, AIM PMD D CID CLS, L4531M, Edition 1.1, 10.07.2006
FURTHER ELECTRICAL CHARACTERISTICS:
This chip data sheet refers to the
device data sheet FS15R06XE3
Description:
AQL 0,65 for visual inspection according to failure catalog
Electrostatic Discharge Sensitive Device according to MIL-STD 883
Test-Normen Villach/Prüffeld
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2006.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as warranted
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement,
regarding circuits, descriptions and charts stated herein.
Infineon Technologies is an approved CECC manufacturer.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office in Germany or our Infineon Technologies Representatives world -wide (see
address list).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types
in question please contact your nearest Infineon Technologies Office.
Infineon Technologies components may only be used in life-support devices or systems with the express
written approval of Infineon Technologies, if a failure of such components can reasonably be expected to
cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or
system. Life support devices or systems are intended to be implanted in the human body, or to support
and / or maintain and sustain and / or protect human life. If they fail, it is reasonable to assume that the
health of the user or other persons may be endangered.