1
Simple Fiber Amplifier Unit
E3X-SD/-NA
Simple and Affordable Fiber Amplifier Units
Reasonable price.
Use the one-key one-function feature for quick,
easy operation.
GIGA RAY for the highest level of power in this class for
stable detection even with sensing objects with low
reflection or large sensing objects. *
*Excluding E3X-NA@@V Amplifiers.
Ordering Information
Fiber Amplifier Units [Refer to Dimensions on page 11.]
Digital Display and Direct Key Setting
*An Amplifier Unit Connector (sold separately) is required.
Bar Display and Adjuster Setting
*1. An Amplifier Unit Connector (sold separately) is required.
*2. A Sensor I/O Connector (sold separately) is required.
Item Appearance Connection
method
Ratings and
Specifications
Model
NPN output PNP output
Standard models
Pre-wired (2 m)
---
E3X-SD21 2M E3X-SD51 2M
Wire-saving
connector * E3X-SD7 E3X-SD9
Item Appearance Connection
method
Ratings and
Specifications
Model
NPN output PNP output
Standard models
Pre-wired (2 m)
---
E3X-NA11 2M E3X-NA41 2M
Wire-saving
connector *1 E3X-NA6 E3X-NA8
High-speed
detection models Pre-wired (2 m) Response time: 20 μsE3X-NA11F 2M E3X-NA41F 2M
Water-resistant
models
Pre-wired (2 m)
Degree of protection:
IP66
E3X-NA11V 2M E3X-NA41V 2M
Connector (M8) *2 E3X-NA14V E3X-NA44V
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
E3X-SD/-NA
2
Accessories (sold separately)
Amplifier Unit Connectors (Required for models for Wire-saving Connectors.)
Note: Protective seals provided. [Refer to Dimensions on page 15.]
Sensor I/O Connectors (Required for models with M8 Connectors.)
[Refer to Dimensions on
XS3
.]
Item Appearance Cable length No. of conductors Model
Master Connector
2 m
3E3X-CN11
Slave Connector 1E3X-CN12
Size Cable specifications Appearance Cable type Model
M8 Standard cable
2 m
Four-
conductor
cable
XS3F-M421-402-A
5 m XS3F-M421-405-A
2 m XS3F-M422-402-A
5 m XS3F-M422-405-A
Ordering Precautions for Amplifier Units
Connectors
Fiber Amplifier Units Applicable Connectors (sold separately)
Type NPN PNP +Master Connector Slave Connector
A Connector is not provided with the Amplifier Unit.
Refer to the tables at the right when placing an order. Standard
models
E3X-SD7 E3X-SD9 E3X-CN11 (3-wire) E3X-CN12 (1-wire)
E3X-NA6 E3X-NA8
When Using 5 Amplifier Units
5 Fiber Amplifier Units +1 Master Connector + 4 Slave Connectors
Straight
connector
L-shaped
connector
Mounting Brackets
A Mounting Bracket is not provided with the Fiber Amplifier Unit. Order a
Mounting Bracket separately if required.
[Refer to Dimensions on page 15.]
Appearance Applicable models Model Quantity
E3X-SD@
E3X-NA@
E3X-NA@F
E39-L143
1
E3X-NA@VE39-L148
End Plate
End Plates are not provided with the Fiber Amplifier Unit.
Order End Plates separately if required.
[Refer to Dimensions on page 15.]
Appearance Model Quantity
PFP-M 1
E3X-SD/-NA
3
Ratings and Specifications
Fiber Amplifier Units
1. When there are 8 or more E3X-NA Amplifiers mounted side-by-side, the response time will be 350 μs max.
2. Mutual interference prevention is effective when E3X-SD/-NA-series Fiber Amplifier Units are gang-mounted without other E3X-series Fiber Amplifier Units.
3. Water-resistant models and models with connectors have a dielectric strength of 500 VAC.
4. Add 10 g for water-resistant models.
Amplifier Unit Connectors (Wire-saving Connectors)
Type
Digital display and direct key setting Bar display and adjuster setting
Standard models Standard models High-speed detection
models Water-resistant models
Model E3X-SD@E3X-NA@E3X-NA@FE3X-NA@V
Item
Light source (wavelength) Red, 4-element LED (625 nm) Red LED (680 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Power consumption/
Current consumption
At Power Supply Voltage of 24 VDC
960 mW max./40 mA max.
At Power Supply Voltage of 12 VDC
960 mW max./80 mA max.
At Power Supply Voltage of 24 VDC
840 mW max./35 mA max.
At Power Supply Voltage of 12 VDC
420 mW max./35 mA max.
Control output
Open-collector output (NPN or PNP)
Load power supply: 26.4 V max.,
Load current: 50 mA max.
(Residual voltage: 1.5 V max.)
Light-ON/Dark-ON mode selector
Open-collector output (NPN or PNP)
Load power supply: 26.4 V max.,
Load current: 50 mA max.
(Residual voltage: 1 V max.)
Light-ON/Dark-ON mode selector.
Response time Operate or reset: 200 μs max. (1) Operate: 20 μs max.
Reset: 30 μs max.
Operate or reset:
200 μs max. (1)
Sensitivity adjustment UP/DOWN direct key setting, teaching
with/without a workpiece, automatic teaching 8-turn sensitivity adjuster (with indicator)
Protection circuits
Power supply reverse polarity protection,
output short-circuit protection,
output reverse polarity protection
Power supply reverse polarity protection,
output short-circuit protection
Timer function --- No timer, OFF-delay timer; or Timer selector (timer time: 40 ms (fixed))
Mutual interference
prevention Up to 5 Amplifiers (optically synchronized) (2) None Up to 5 Amplifiers (optical-
ly synchronized) (2)
Ambient illumination
Receiver side
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Number of gang-mounted
Amplifiers 16 max. (The ambient temperature specification depends on the number of gang-mounted Amplifiers.)
Ambient temperature
range
Operating: Groups of 1 to 3 Amplifiers: 25°C to 55°C
Groups of 4 to 11 Amplifiers: 25°C to 50°C
Groups of 12 to 16 Amplifiers: 25°C to 45°C
Storage: 30°C to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85%
(with no condensation)
Operating: 35% to 85%
Storage: 35% to 95%
(with no condensation)
Insulation resistance 20 MΩ. min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute (3)
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
IEC 60529 IP66
(with Protective Cover at-
tached)
Connection method Pre-wired (standard cable length: 2 m), or connector
Weight (packed state) (4) Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g
Material Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC) Polyethersulfone (PES)
Accessories Instruction manual
Item Model E3X-CN11 E3X-CN12
Rated current 2.5 A
Rated voltage 50 V
Contact resistance
20 mΩ max. (20 mVDC max., 100 mA max.)
(The above figure is for connection to the Fiber Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of
the cable.)
Number of insertions Destruction: 50 times (for connection to the Fiber Amplifier Unit and the adjacent Connector)
Material Housing Polybutylene terephthalate (PBT)
Contact Phosphor bronze/gold-plated nickel
Weight (packed state) Approx. 55 g Approx. 25 g
E3X-SD/-NA
4
Sensing distance
Threaded Models
Cylindrical Models
Flat Models
Sleeve Models
Detection
method Sensing direction Size Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
Right-angle
M4
E32-T11N 2M 530 160 280
E32-LT11N 2M 1,800 600 900
Straight
E32-T11R 2M 560 160 280
E32-LT11 2M 2,100 700 1,050
E32-LT11R 2M 1,800 600 900
Reflective
Right-angle
M3 E32-C31N 2M 25 7.5 13
E32-C21N 2M 65 21 32
M4 E32-D21N 2M 170 56 85
M6 E32-C11N 2M 170 50 85
E32-LD11N 2M 170 56 85
Straight
M3
E32-D21R 2M 30 10 15
E32-C31 2M 80 26 40
E32-C31M 1M
M4 E32-D211R 2M 30 10 15
M6
E32-D11R 2M 180 60 90
E32-CC200 2M 300 100 150
E32-LD11 2M 180 60 90
E32-LD11R 2M 170 56 85
Detection
method Size Sensing direction Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
1 dia.
Top-view
E32-T223R 2M 120 36 60
1.5 dia. E32-T22B 2M 200 60 100
3 dia. E32-T12R 2M 560 160 280
Side-view E32-T14LR 2M 220 66 110
Reflective
1.5 dia.
Top-view
E32-D22B 2M 30 10 15
1.5 dia. + 0.5 dia. E32-D43M 1M 6 2 3
3 dia.
E32-D22R 2M 30 10 15
E32-D221B 2M 70 20 35
E32-D32L 2M 160 50 80
3 dia. + 0.8 dia. E32-D33 2M 16 410
Detection
method Sensing direction Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
Top-view E32-T15XR 2M 560 160 280
Side-view E32-T15YR 2M 220 66 110
Flat-view E32-T15ZR 2M
Reflective
Top-view E32-D15XR 2M 180 60 90
Side-view E32-D15YR 2M 40 10 20
Flat-view E32-D15ZR 2M
Detection
method Sensing direction Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
Side-view E32-T24R 2M 60 18 30
E32-T24E 2M 180 36 60
Top-view
E32-T21-S1 2M 130 43 65
E32-T33 1M 40 13.5 20
E32-TC200BR 2M 560 160 280
Reflective
Side-view E32-D24R 2M 14 4.6 7
E32-D24-S2 2M 26 813
Top-view
E32-D43M 1M 6 2 3
E32-D331 2M 3 1 1.5
E32-D33 2M 16 410
E32-D32-S1 0.5M 14 4 7
E32-D31-S1 0.5M
E32-DC200F4R 2M 30 10 15
E32-D22-S1 2M 57 19 28
E32-D21-S3 2M
E32-DC200BR 2M 180 60 90
E32-D25-S3 2M 57 19 28
E3X-SD/-NA
5
Small-spot, Reflective
High-power Beam
*1. Thefiberlengthis10moneachside,sothesensingdistanceisgivenas20,000mm.
*2. Thefiberlengthis2moneachside,sothesensingdistanceisgivenas4,000mm.
Narrow View
Detection without Background Interference
Type
Spot diameter
Center distance
(mm)
Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Variable spot 0.1 to 0.6 dia. 6 to 15 E32-C42 1M + E39-F3A Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
0.3 to 1.6 dia. 10 to 30 E32-C42 1M + E39-F17 Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.
Parallel light 4 dia. 0 to 20 E32-C31 2M + E39-F3C Spot diameter of 4 mm max. at 0 to 20 mm.
E32-C31N 2M + E39-F3C
Integrated lens 0.1 dia. 5E32-C42S 1M Spot diameter of 0.1 mm at 5 mm.
6 dia. 50 E32-L15 2M Spot diameter of 6 mm at 50 mm.
Small-spot
0.1 dia.
7
E32-C41 1M + E39-F3A-5 Spot diameter of 0.1 mm at 7 mm.
0.5 dia. E32-C31 2M + E39-F3A-5 Spot diameter of 0.5 mm at 5 mm.
E32-C31N 2M + E39-F3A-5
0.2 dia.
17
E32-C41 1M + E39-F3B Spot diameter of 0.2 mm at 17 mm.
0.5 dia. E32-C31 2M + E39-F3B Spot diameter of 0.5 mm at 17 mm.
E32-C31N 2M + E39-F3B
3 dia. 50 E32-CC200 2M + E39-F18 Spot diameter of 3 mm at 50 mm.
E32-C11N 2M + E39-F18
Type Sensing direction Aperture
angle Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
Integrated lens
Right-angle 15° E32-LT11N 2M 1,800 600 900
Top-view
10° E32-T17L 10M 20,000 *1 8,400 14,000
15° E32-LT11 2M 2,100 700 1,050
15° E32-LT11R 2M 1,800 600 900
Side-view 30° E32-T14 2M 3,600 1,080 1,800
Through-beam
models with
lenses
Right-angle 12° E32-T11N 2M + E39-F1 3,700 1,110 2,100
E32-T11N 2M + E39-F16 4,000 *2 2,000 3,600
Top-view 12° E32-T11R 2M + E39-F1 4,000 *2 1,260 2,100
E32-T11R 2M + E39-F16 4,000 *2 2,000 3,600
Side-view 60° E32-T11R 2M + E39-F2 440 130 220
Top-view 12° E32-T11 2M + E39-F1 4,000 *2 1,200 2,000
E32-T11 2M + E39-F16 4,000 *2 2,600 4,000 *2
Side-view 60° E32-T11 2M + E39-F2 720 200 360
Top-view 12° E32-T51R 2M + E39-F1 2,000 720 1,650
E32-T51R 2M + E39-F16 4,000 *2 1,560 2,900
Side-view 60° E32-T51R 2M + E39-F2 360 120 200
Top-view 12° E32-T81R-S 2M + E39-F1 1,800 630 1,100
E32-T81R-S 2M
+
E39-F16
4,000 *2 1,300 2,300
Side-view 60° E32-T81R-S 2M + E39-F2 280 84 140
Top-view 12° E32-T61-S 2M + E39-F1 4,000 *2 1,800 3,000
E32-T61-S 2M + E39-F16 4,000 *2 2,340 3,900
Side-view 60° E32-T61-S 2M + E39-F2 780 260 390
Top-view 12° E32-T51 2M + E39-F1-33 2,400 720 1,400
E32-T51 2M + E39-F16 4,000 *2 3,120 4,000 *2
Reflective
Integrated lens Top-view E32-D16 2M 800 140 40 to 400
Detection
method Sensing direction Aperture
angle Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam Side-view
1.5° E32-A03 2M 890 267 445
E32-A03-1 2M
3.4° E32-A04 2M 340 102 170
E32-T24SR 2M 1,170 360 600
E32-T24S 2M 1,400 420 700
E32-T22S 2M 2,000 600 1,000
Detection
method Sensing direction Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Limited-
reflective
Flat-view E32-L16-N 2M 0 to 15 0 to 12 0 to 15
E32-L24S 2M 0 to 4
Side-view E32-L25L 2M
5.4 to 9 (center 7.2) 5.4 to 8 (center 7.2) 5.4 to 9 (center 7.2)
E3X-SD/-NA
6
Transparent Object Detection (Retro-reflective)
Transparent Object Detection (Limited-reflective)
Chemical-resistant, Oil-resistant
*The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Bending-resistant
Heat-resistant
Detection
method Feature Size Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Retroreflective
Sensors
Film detection M3 E32-C31 2M +
E39-F3R + E39-RP37 220 50 75
Square E32-R16 2M 1,500 1,000 150 to 1,500
Threaded Models
M6
E32-R21 2M 10 to 250 250 10 to 250
Hex-shaped E32-LR11NP 2M +
E39-RP1 600 200 300
Detection
method Feature Sensing
direction Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Retro-reflective
Small size
Flat-view
E32- L24S 2M
0 to 4
Standard
E32-L16-N 2M
0 to 15 0 to 12 0 to 15
Glass substrate
alignment, 70°C E32-A08 2M 10 to 20
Standard/
long-distance E32-A12 2M 12 to 30
Side view form
Side-view
E32-L25L 2M 5.4 to 9 (center 7.2) 5.4 to 8 (center 7.2) 5.4 to 9 (center 7.2)
Glass substrate
mapping, 70°C
Top-view
E32-A09 2M
15 to 3
8 (cent
er 25)
Detection
method Type Sensing
direction Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
Oil-resistant
Right-angle E32-T11NF 2M
4,000 * 1,400 2,400
Chemical/oil-resistant Top-view E32-T12F 2M 3,200 960 1,600
E32-T11F 2M 2,100 760 1,050
Side-view E32-T14F 2M 400 120 200
Chemical/oil-resistant
at 150°C Top-view E32-T51F 2M 1,400 400 700
Reflective
Semiconductors:
Cleaning, developing,
and etching; 60°C
Top-view
E32-L11FP 2M
8 to 20 mm from tip of lens (Recommended sensing distance: 11
mm), 19 to 31 mm from center of mounting hole A (Recommended
sensing distance: 22 mm)
Semiconductors:
Resist stripping; 85°
C
E32-L11FS 2M
8 to 20 mm from tip of lens (Recommended sensing distance: 11
mm), 32 to 44 mm from center of mounting hole A (Recommended
sensing distance: 35 mm)
Chemical/oil-resistant E32-D12F 2M 100 32 50
Chemical-resistant cable
E32-D11U 2M 180 60 90
Detection
method Size Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
1.5 dia. E32-T22B 2M 200 60 100
M3 E32-T21 2M
M4 E32-T11 2M 720 200 360
Square E32-T25XB 2M 150 40 75
Reflective
1.5 dia. E32-D22B 2M 30 10 15
M3 E32-D21 2M
3 dia. E32-D221B 2M 70 20 35
M4 E32-D21B 2M
M6 E32-D11 2M 180 60 90
Square E32-D25XB 2M 50 16 25
Detection
method Heat-resistant temperature Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam
100°C E32-T51R 2M 400 120 225
150°C E32-T51 2M 800 240 400
200°C E32-T81R-S 2M 360 100 180
350°C E32-T61-S 2M 600 180 300
Reflective
100°C E32-D51R 2M 140 42 70
150°C E32-D51 2M 240 80 120
200°C E32-D81R 2M 90 27 45
300°C E32-A08H2 2M 10 to 20
E32-A09H2 2M 20 to 30 (center 25)
350°C E32-D61 2M 90 27 45
400°C E32-D73 2M 60 18 30
E3X-SD/-NA
7
Area Beam
Liquid-level Detection
Vacuum-resistant
FPD, Semiconductors, and Solar Cells
Detection
method Type Sensing
width Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam Area 11 mm E32-T16PR 2M 800 260 450
E32-T16JR 2M 700 220 390
30 mm E32-T16WR 2M 1,380 400 690
Reflective Array 11 mm E32-D36P1 2M 150 50 75
Detection
method Pipe diameter Feature Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Tube-mounting
3.2/6.4/9.5 dia.
Stable residual
quantity detection
E32-A01 5M Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5
mm, Recommended wall thickness: 1 mm
8 to 10 dia. Mounting at
multi levels E32-L25T 2M Applicable tube: Transparent tube with a diameter of 8 to 10 mm,
Recommended wall thickness: 1 mm
No restrictions
Large tubes E32-D36T 2M
Applicable tube: Transparent tube (no restrictions on diameter)
Liquid contact
(heat-resistant
up to 200°C)
E32-D82F1 4M
Liquid-contact model
Detection
method Heat-resistant temperature Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Through-beam 120°C E32-T51V 1M 200 100
E32-T51V 1M + E39-F1V 1,200 600
200°C E32-T84SV 1M 500 250
Detection
method Application Operating
temperature Model
Sensing distance (mm)
E3X-SD@
E3X-NA@E3X-NA@FE3X-NA@V
Limited-
reflective
Glass presence detection 70°C E32-L16-N 2M 0 to 15 0 to 12 0 to 15
Glass substrate alignment
E32-A08 2M 10 to 20
300°C
E32-A08H2 2M
70°C E32-A12 2M 12 to 30
Glass substrate mapping E32-A09 2M 15 to 38 (center 25)
300°C
E32-A09H2 2M
20 to 30 (center 25)
Wet processes: Cleaning, Resist
developing and etching 60°C
E32-L11FP 2M
8 to 20 mm from tip of lens (Recommended sensing distance: 11
mm), 19 to 31 mm from center of mounting hole A (Recommended
sensing distance: 22 mm)
Wet process: Resist stripping 85°C
E32-L11FS 2M
8 to 20 mm from tip of lens (Recommended sensing distance: 11
mm), 32 to 44 mm from center of mounting hole A (Recommended
sensing distance: 35 mm)
Through-
beam Wafer mapping 70°C
E32-A03 2M 890 267 445
E32-A03-1 2M
E32-A04 2M 340 102 170
E32-T24SR 2M
1,170 360 600
E32-T24S 2M 1,400 420 700
E3X-SD/-NA
8
I/O Circuit Diagrams
Note: Timing Charts for Timer Settings (T: Set Time)
Plug (Sensor I/O Connector)
Output
form Model
Output
transistor
operation mode
Timing charts Operation
selector Output circuit
NPN
Output
E3X-SD21
E3X-SD7
E3X-NA11
E3X-NA6
E3X-NA11F
E3X-NA11V
E3X-NA14V
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
PNP
Output
E3X-SD51
E3X-SD9
E3X-NA41
E3X-NA8
E3X-NA41F
E3X-NA41V
E3X-NA44V
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
OFF delay
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
T
Black
Brown
Blue
Control output
Operation indicator
(orange)
Photo-
electric
Sensor
main
circuit
Load
12 to
24 VDC
1
4
3
M8 Connector Pin Arrangement
Note: Pin 2 is not used.
1
24
3
Not present on the E3X-NA.
T
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
T
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
1
4
3
1
24
3
Not present on the E3X-NA.
Black
Brown
Blue
Control output
Operation
indicator
(orange) Photo-
electric
Sensor
main
circuit Load
12 to
24 VDC
M8 Connector Pin Arrangement
Note: Pin 2 is not used.
T
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Note: Pin 2 is not used.
Classification Wire color Connection pin Application
DC
Brown 1Power supply (+V)
White 2---
Blue 3Power supply (0 V)
Black 4Output
2
4
1
3
1
2
3
4
Brown
White
Blue
Black
Wire color
Terminal number
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
E3X-SD/-NA
9
Safety Precautions
This product is not designed or rated for
ensuring safety of persons either directly or
indirectly.
Do not use it for such purposes.
Do not exceed the rated voltage.
Excess voltage may result in malfunction or
fire.
Do not use an AC power supply.
Using an AC power supply may result in
rupturing.
High-temperature environments may result in
burn injury.
The following precautions must be observed to ensure safety.
1. Do not use the product in locations where flammable or
explosive gas is present.
2. Do not use the product in locations subject to splashing
water, oil, or chemicals, or in locations subject to steam.
3. Do not attempt to disassemble, repair, or modify the
product.
4. Do not apply voltage or current in excess of the rated
ranges.
5. Do not use the product in atmospheres or environments
that exceed product ratings.
6. Do not wire the product incorrectly, such as using incorrect
power supply polarity.
7. Connect the load properly.
8. Do not short-circuit both ends of the load.
9. Do not use the product if the case is damaged.
10. When disposing of the product, dispose of it as industrial
waste.
11. Do not use the product in locations subject to direct
sunlight.
12. The surface temperature of the product may rise as a
result of the ambient temperature, power supply, or other
usage conditions. Use caution when performing
maintenance and washing. Failure to do so may result in
burn injury.
Do not use the product in atmospheres or environments that
exceed product ratings.
Fiber Amplifier Units
Designing
Communications Hole
The hole on the side of the Amplifier Unit is a communications
hole for preventing mutual interference when Amplifier Units
are mounted side-by-side. The E3X-MC11 Mobile Console
(sold separately) cannot be used.
If an excessive amount of light is received via the Sensor, the
mutual interference prevention function may not work. In this
case, make the appropriate adjustments using the sensitivity
adjuster.
Mutual interference prevention is effective when E3X-SD/-
NA-series Amplifier Units are gang-mounted without other
E3X-series Amplifiers.
Mounting
DIN Track Mounting/Removal
Mounting Fiber Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and
press the Amplifier Units together until they click into place.
Removing Fiber Amplifier Units
Slide Amplifier Units away from each other, and remove from
the DIN track one at a time. (Do not attempt to remove
Amplifier Units from the DIN track without separating them
first.)
WARNING
Caution
Precautions for Safe Use
Precautions for Correct Use
Note 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before mounting or removing
Amplifier Units.
Click into
place
Clip
E3X-SD/-NA
10
Fiber Unit Connection and Disconnection
The E3X Amplifier Unit has a lock lever. Connect or
disconnect the fiber units to or from the E3X Amplifier Unit
using the following procedures:
1. Connection
Open the Protective Cover, insert the fiber units according to
the fiber unit insertion marks on the side of the Amplifier Unit,
and lower the lock lever.
Note:
If one of the fibers from the Fiber Unit is labeled as the Emitter fiber, such as
with a Coaxial Sensor, insert that fiber into the Emitter section. Refer to
Dimensions for the Fiber Unit to see if there is an Emitter fiber label.
2. Disconnection
Remove the Protective Cover and raise the lock lever to pull
out the fiber unit.
Note:To maintain the fiber unit properties, confirm that the lock is
released before removing the fiber unit.
3. Precautions for Fiber Unit Connection/Disconnection
Be sure to lock or unlock the lock lever within an ambient
temperature range between 10°C and 40°C.
Operating Environment
Ambient Conditions
If dust or dirt adhere to the hole for optical communications, it
may prevent normal communications. Be sure to remove any
dust or dirt before using the Units.
Other
Protective Cover
Be sure to mount the Protective Cover before use.
Fiber Amplifier Unitts with Connectors
Mounting
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
until it clicks into place.
2. Join Amplifier Units together as required after all the Master
and Slave Connectors have been inserted.
3. Attach the stickers (provided as accessories) to the sides of
Master and Slave Connectors that are not connected to
other Connectors.
Note: Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to
be removed away from the rest of the group.
2. After the Amplifier Unit has been separated, press down on
the lever on the Connector and remove it. (Do not attempt
to remove Connectors without separating them from other
Amplifier Units first.)
Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier Unit may move
during operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the
master Amplifier Unit using a nipper or similar tool.
The clip can also be removed using the following mechanism,
which is incorporated in the construction of the section
underneath the clip.
1. Insert the clip to be removed into the slit underneath the clip
on another Amplifier Unitt.
2. Remove the clip by rotating the Amplifier Unit.
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.
Lock lever
Fiber unit Fiber unit insertion mark 10.7 mm
Insertion position
Locked Unlocked
Protective Cover
Insert
Sticker
Sticker
Remove
Lever
Press down
Clip
Rotate
E3X-SD/-NA
11
Dimensions
Fiber Amplifier Units
(Unit: mm)
Tolerance class IT16 applies to dimensions in this sheet unless otherwise specified.
18
4.3
8
10.7
10
10
3.4
22.4
4.4
13
64.3
64.3
16
10.75
16
8
10.7
3 128.95
128.95
3 128.95
128.95
2.4
4
2.4
4
10.75
16
10 10
L
(16.5)
3.4
31.5
31.5
(16.5)
3.4
31.5
31.5
(9.4)
18
93.75
93.75
10
10
15
93.75
93.75
13
12.4 30.4
64.3
64.3
Operation indicator
Two,
2.4 dia.
Two,
2.4 dia.
Hole for optical communications
Hole for optical communications
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
End Plate
(sold separately)
PFP-M
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Fiber Attachment mounted (E39-F9)
Two, M3
Mounting Holes
There is no hole for E3X-NA@F models.
With Mounting Bracket Attached
Multiple connection diagram
DIN track mounting
Vinyl-insulated round cable
4 dia. cable / 3 conductors / Standard length: 2 m
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
Two, 3.2 dia. holes
Amplifier Units with Cables
E3X-SD21
E3X-SD51
E3X-NA11
E3X-NA11F
E3X-NA41
E3X-NA41F
The number of
expansion L (mm)
110
220
330
440
550
660
770
880
990
10 100
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Fiber Amplifier Units if they are mounted side by side.
E3X-SD/-NA
12
Amplifier Units with
C
onnectors
E3X-SD7
E3X-SD9
E3X-NA6
E3X-NA8
4.3
8
10.7
10
10
3.4
22.4
4.4
13
64.3
64.3
16
16
8
10.7
3128.95
128.95
3128.95
128.95
16
10 10
L
(16.5)
3.4
31.5
31.5
(16.5)
3.4
31.5
31.5
(9.4)
18
93.75
93.75
10
10
15
93.75
93.75
13
12.430.4
64.3
64.3
Operation indicator
Two,
2.4 dia.
Two,
2.4 dia.
Hole for optical communications
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
End Plate
(sold separately)
PFP-M
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Fiber Attachment mounted (E39-F9)
Two, M3
Mounting Holes
With Mounting Bracket Attached
Multiple connection diagram
DIN track mounting
Two, 3.2 dia. holes
18
A dia.
12.95
Hole for optical communications
A dia.
12.95
Cable Diameters
E3X-CN11 (3 conductors) 4.0 dia.
E3X-CN12 (1 conductor) 2.6 dia.
The number of
expansion L (mm)
110
220
330
440
550
660
770
880
990
10 100
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Fiber Amplifier Units if they are mounted side by side.
E3X-SD/-NA
13
9.2
28.65
25.95
8
10.7 11.2
6.9
12
12
12
12
8
10.7
14.4 9.5
67.2
67.2
16
16
23.9
6.6
11.2
5.4
3.4
16
14.4
31.9
67.2
67.2
18
152.3
152.3
6.9 152.3
152.3
105.9
105.9
105.9
105.9
10 10
L
18
18
4.3
3.4
33
33
(16.5)
3.4
33
33
(16.5)
Operation indicator Incident level indicators
Vinyl-insulated round cable
4 dia. cable / 3 conductors / Standard length: 2 m
(Conductor cross section: 0.45 mm
2
,
Insulator diameter: 1.1 mm)
DIN track mounting
Two,
2.4 dia.
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
End Plate
(sold separately)
PFP-M
Multiple connection diagram
Hole for optical communications
Hole for optical communications
Mounting Bracket (E39-L148)
SUS304 stainless steel (sold separately)
With Mounting Bracket Attached
Fiber Attachment mounted (E39-F9)
Two, M3
Mounting Holes
Two,
2.4 dia.
Area of digital indication
Amplifier Units with Cables,
Water-resistant Models
E3X-NA11V
E3X-NA41V
The number of
expansion L (mm)
112
224
336
448
560
672
784
896
9108
10 120
E3X-SD/-NA
14
9.2
28.65
25.95
8
10.7 11.2
6.9
12
12
12
12
8
10.7
14.4 9.5
67.2
67.2
16
16
23.9
11
11.2
5.4
3.4
16
14.4
31.9
67.2
67.2
18
152.3
152.3
6.9 152.3
152.3
105.9
105.9
105.9
105.9
10 10
L
18
18
4.3
3.4
33
33
(16.5)
3.4
33
33
(16.5)
Operation indicator Incident level indicators
DIN track mounting
Two,
2.4 dia.
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
End Plate
(sold separately)
PFP-M
Multiple connection diagram
Hole for optical communications
Hole for optical communications
Mounting Bracket (E39-L148)
SUS304 stainless steel (sold separately)
With Mounting Bracket Attached
Fiber Attachment mounted (E39-F9)
Two, M3
Mounting Holes
Two,
2.4 dia.
Area of digital indication
Amplifier Units with
C
onnectors,
Water-resistant Models
E3X-NA14V
E3X-NA44V
The number of
expansion L (mm)
112
224
336
448
560
672
784
896
9108
10 120
E3X-SD/-NA
15
Amplifier Unit Connectors (Wire-saving Connectors)
Accessories (sold separately)
Master Connector
E3X-CN11 (7)
2,000 +50
0
E3X-CN11: 4 dia.
4 dia.
cable / 3 conductors
3 conductors
/ Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Edge of amplifier
Slave Connector
E3X-CN12
(7)
2,000 +50
0
E3X-CN12: 2.6 dia.
2.6 dia.
cable / 1 conductor
1 conductor
/ Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Edge of amplifier
Mounting Brackets
E39-L143
Four, R1.7
7
3.4
1
3163
10 max. 710.3
7.3
5.3
(10.3) 2.5
34.8
22
16
26.8
3
Two, 3.2 dia.
3.4
1
Two, M3
16±0.1
Mounting Holes
Material: Stainless steel
(SUS304)
End Plates
PFP-M
50
11.5
10
M4 × 8
panhead screw
M4 spring washer
4.8
1.3
1.8
1.8
1
6.2 10
35.5
35.3
E3X-SD/-NA
16
Nomenclature
Operating Procedure
E3X-SD
The sensitivity can be set with the UP and DOWN Keys similar
to using an adjuster knob. The sensitivity can also be easily
set by using the following two teaching functions.
Two points (one with the workpiece and the other without) are
detected, and the operating level is set to the midpoint.
Light level is also automatically set to the optimal value.
Changes within a time are detected, and the operating level is
set to the midpoint between the maximum and the minimum
values of the changes. This setting is optimal for when the
workpieces cannot be stopped. Execute automatic teaching
again if the incident light level is not automatically set to the
optimal value.
E3X-NA
A bar display (with four green and one red) showing excess
gain is provided in addition to the orange operation indicator.
Use these when adjusting the light axis and setting the
sensitivity at setup.
Digital threshold value adjustment
(UP/DOWN)
Teaching status
indication(orange)
Operation Selector
Use to switch between
Light-ON and Dark-ON
Lock Lever
Digital incident light level display or
digital threshold
value
display (red)
Display of contents of functions
during operation
Light-ON and
Dark-ON Indicator
Teaching Button
The sensitivity and threshold
value can be set automatically.
Operation Indicator
(Orange)
Fiber Amplifier Units
E3X-SD E3X-NA
Incident level indicators
Lock lever
Sensitivity indicator
8-turn sensitivity adjuster
Operation Indicator
Operation Selector
Use to switch between
Light-ON and Dark-ON
Timer switch
ON: Timer function is ON.
OFF: Timer function is OFF.
Operation description Button/Key
Press the TEACH button with the workpiece.
Press the TEACH button without the
workpiece.
Operation description Button/Key
Press the TEACH button for 3 s min. Let the
workpiece pass while the button is pressed.
Sensitivity Setting1
2-1. Teaching with/without a Workpiece
TEACH
TEACH
2-2. Automatic Teaching
TEACH
Display/indicator status (for L/ON) Excess gain
level Description
Approx.
120% min.
Stable incident
light
Approx.
110% to 120%
Approx.
90% to 110%
Unstable
incident light or
Unstable
interrupted light
Approx.
80% to 90%
Stable
interrupted light
Approx.
80% max.
Displays1
Operation indicator
Excess gain level display
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. E401-E1-01 0110
© OMRON Corporation 2010 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
This document provides information mainly for selecting suitable models. Please read the Instruction sheet carefully for information that the user
must understand and accept before purchase, including information on warranty, limitations of liability, and precautions.
CSM_6_2_0915