MOS FET Relays G3VM-61A1/D1 11
MOS FET Relays
G3VM-61A1/D1
Compact, General-purpose, Analog-switching
MOS FET Relay, with Dielectric Strength of
2.5 kVAC between I/O Using Optical Isolation
Upgraded G3VM-61 A/D Series.
Switches minute analog signals.
RoHS Compliant.
Application Examples
Measurement devices
Security systems
Amusement machines Note: The actual product is marked differently from the image shown
here.
List of Models
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/Internal Connections (Top View)
PCB Dimensions (Bottom View) Actual Mounting Pad Dimensions
(Recommended Value, Top View)
Contact form Terminals Load voltage (peak value) Model Number per stick Number per tape
SPST-NO PCB terminals 60 VAC G3VM-61A1 100 ---
Surface-mounting
terminals
G3VM-61D1
G3VM-61D1(TR) --- 1,500
4.58±
0.25
6.4±
0.25
2.54±
0.25
1.2±
0.15
0.5±
0.1
0.8±
0.25
7.62±
0.25
7.85 to 8.80
2.5 min.
3.65
+0.15
0.25
0.25
+0.1
0.05
4.58±0.25
6.4±0.25
2.54±0.25
1.2±0.15
7.62±0.25
10.0 max.
1.0 min.
1.0
min.
3.65 +0.15
0.25 4.0 +0.25
0.2
G3VM-61A1 G3VM-61D1
Note: The actual product
is marked different-
ly from the image
shown here.
Note: The actual product
is marked different-
ly from the image
shown here. Weight: 0.25 g Weight: 0.25 g
43
12
43
12
G3VM-61A1 G3VM-61D1
Four 0.8-dia. holes
2.54
2.54
(0.61)
(0.61)
(1.52)
(1.52)
G3VM-61A1
G3VM-61D1
12 MOS FET Relays G3VM-61A1/D1
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Symbol Rating Unit Measurement conditions
Input LED forward current IF50 mA
Repetitive peak LED forward
current
IFP 1 A 100 μs pulses, 100 pps
LED forward current
reduction rate
Δ IF/°C0.5 mA/°CTa 25°C
LED reverse voltage VR5V
Connection temperature Tj125 °C
Output Load voltage (AC peak/DC) VOFF 60 V
Continuous load current IO500 mA
ON current reduction rate Δ ION/°C5.0 mA/°CTa 25°C
Connection temperature Tj125 °C
Dielectric strength between input and
output (See note 1.)
VI-O 2,500 Vrms AC for 1 min
Operating temperature Ta40 to +85 °C With no icing or condensation
Storage temperature Tstg 55 to +125 °C With no icing or condensation
Soldering temperature (10 s) --- 260 °C10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item Symbol Minimum Typical Maxi-
mum Unit Measurement
conditions
Input LED forward voltage VF1.0 1.15 1.3 V IF = 10 mA
Reverse current IR--- --- 10 μAV
R = 5 V
Capacity between terminals CT--- 30 --- pF V = 0, f = 1 MHz
Trigger LED forward current IFT --- 1.6 3 mA IO = 500 mA
Output Maximum resistance with output ON RON --- 1 2 ΩIF = 5 mA,
IO = 500 mA
Current leakage when the relay is open ILEAK --- 0.001 1.0 μAV
OFF = 60 V
Capacity between terminals COFF --- 130 --- pF V = 0, f = 1MHz
Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance RI-O 1,000 --- --- MΩVI-O = 500 VDC,
RoH 60%
Tu r n - O N t i m e t ON --- 0.8 2.0 ms IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Turn-OFF time tOFF --- 0.1 0.5 ms
10% 90%
VOUT
IF
tON tOFF
IF1
2
4
3
RLVDD
VOUT
Note: 2. Turn-ON and Turn-OFF
Times
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD --- --- 48 V
Operating LED forward current IF57.525mA
Continuous load current (AC peak/DC) IO--- --- 500 mA
Operating temperature Ta 20 --- 65 °C
MOS FET Relays G3VM-61A1/D1 13
Engineering Data
LED forward current vs.
Ambient temperature
IF - Ta
Continuous load current vs.
Ambient temperature
IO - Ta
LED forward current vs.
LED forward voltage
IF - VF
LED forward current I
F
(mA)
Continuous load current I
O
(mA)
LED forward current I
F
(mA)
Ambient temperature Ta ()
Ambient temperature Taഒ
LED forward voltage V
F
(V)
Continuous load current vs.
On-state voltage
IO - VON
On-state resistance vs.
Ambient temperature
RON - Ta
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
Continuous load current I
O
(mA)
On-state resistance R
ON
(Ω)
Trigger LED forward current I
FT
(mA)
On-state voltage V
ON
(V
)
Ambient temperature Ta ()
Ambient temperature Ta ()
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
Current leakage vs.
Ambient temperature
I LEAK - Ta
Turn ON, Turn OFF time t
ON
, t
OFF
(μS)
Turn ON, Turn OFF time t
ON
, t
OFF
(μS)
Current leakage I
LEAK
(nA)
LED forward current I
F
(mA)
Ambient temperature Ta (ഒ
Ambient temperature Ta ()
0
20
60
20
40
80
100
120 100 80 60 40 20 0
0
20 120 100 80 60 40 20 0
600
500
400
300
200
100
Ta = 25°C
0.6 0.8 1 1.2 1.6 1.8 1.4
100
30
10
3
1
0.3
0.1
Ta = 25°C
IF = 5 mA
0.6 0.4 0.2 0 0.4 0.6 0.2
600
400
200
0
200
400
600
IO = 500 mA
IF = 5 mA
3
0
20 0 20 40 80 100 60
1
2
4
5
IO = 500 mA
t < 1 s
3
0
20 0 20 40 80 100 60
1
2
4
5
1 3 5 10 30 50 100 300
30
50
100
300
500
1000
3000
5000
Ta = 25°C
VDD = 20 V
RL = 200 Ω
tOFF
tON
VDD = 20 V
RL = 200 Ω
IF = 5 mA
10
20
3000
1000
300
100
30
0 20 40 80 80 100
tOFF
tON
0.1
20
30
10
3
1
0.3
0 20 40 80 80 100
VOFF = 60 V
MOS FET Relays G3VM-61A1/D1
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X302-E-1 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
12/10 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.