Simple Fiber Amplifier E3X-SD/-NA The Highest Level of Power and Precision in the Industry with "GIGA RAY" Giga Power Lighting Element * Stable detection of minute objects even when the Sensor is covered with dust and oil in severe environments. * Quick-tuning to automatically adjust light level and set threshold value. * Use the one-key one-function feature for quick, easy operation. * Reasonable price. Ordering Information Amplifier Units [Refer to Dimensions on page 13.] Digital Display and Direct Key Setting Item Connection method Appearance Ratings and Specifications Pre-wired (2 m) Standard models Model NPN output PNP output E3X-SD21 2M E3X-SD51 2M E3X-SD7 E3X-SD9 --Wire-saving connector * *An Amplifier Unit Connector (sold separately) is required. Bar Display and Adjuster Setting Item Appearance Connection method Ratings and Specifications Pre-wired (2 m) Standard models PNP output E3X-NA11 2M E3X-NA41 2M E3X-NA6 E3X-NA8 E3X-NA11F 2M E3X-NA41F 2M E3X-NA11V 2M E3X-NA41V 2M E3X-NA14V E3X-NA44V --Wire-saving connector *1 High-speed detection models Model NPN output Pre-wired (2 m) Response time: 20 s Pre-wired (2 m) Water-resistant models Degree of protection: IP66 Connector (M8) *2 *1. An Amplifier Unit Connector (sold separately) is required. *2. A Sensor I/O Connector (sold separately) is required. 1 E3X-SD/-NA Amplifier Unit Connectors (sold separately) Item Appearance Note: Protective seals provided. [Refer to Dimensions on page 17.] Cable length No. of conductors Model 3 E3X-CN11 1 E3X-CN12 Master Connector 2m Slave Connector Ordering Precautions for Amplifier Units Connectors A Connector is not provided with the Amplifier Unit. Refer to the tables at the right when placing an order. Amplifier Units Applicable Connectors (sold separately) Type NPN PNP Standard models E3X-SD7 E3X-SD9 E3X-NA6 E3X-NA8 + Master Connector Slave Connector E3X-CN11 (3-wire) E3X-CN12 (1-wire) When Using 5 Amplifier Units 5 Amplifier Units + 1 Master Connector + 4 Slave Connectors Sensor I/O Connectors (Models for Connectors: A Connector is not provided with the Amplifier Unit. Be sure to order a Connector separately.) [Refer to Dimensions on XS3.] Size Cable specifications M8 Appearance Cable type Straight connector 2m L-shaped connector 2m 5m Standard cable Model XS3F-M421-402-A Fourconductor cable 5m XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A Accessories (sold separately) Mounting Brackets End Plate A Mounting Bracket is not provided with the Amplifier Unit. Order a Mounting Bracket separately if required. [Refer to Dimensions on page 17.] End Plates are not provided with the Amplifier Unit. Order End Plates separately if required. [Refer to Dimensions on page 17.] Appearance 2 Applicable models Model E3X-SD@ E3X-NA@ E3X-NA@F E39-L143 E3X-NA@V E39-L148 Quantity 1 Appearance Model Quantity PFP-M 1 E3X-SD/-NA Ratings and Specifications Amplifier Units Digital display and direct key setting Type Bar display and adjuster setting Standard models Standard models High-speed detection models Water-resistant models E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Model Item Light source (wavelength) Red, 4-element LED (625 nm) Red LED (680 nm) Power supply voltage 12 to 24 VDC 10%, ripple (p-p): 10% max. Power consumption/ Current consumption 960 mW max. (Power supply voltage: 24 V, Current consumption: 40 mA max.) (Power supply voltage: 12 V, Current consumption: 80 mA max.) 960 mW max. (Current consumption: 40 mA max.) Control output Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.) Light-ON/Dark-ON mode selector Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1 V max.) Light-ON/Dark-ON mode selector. Response time Operate or reset: 200 s max. (1) Sensitivity adjustment UP/DOWN direct key setting, teaching with/without a workpiece, automatic teaching 8-turn sensitivity adjuster (with indicator) Protection circuits Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection Power supply reverse polarity protection, output short-circuit protection Timer function --- Operate: 20 s max. Reset: 30 s max. Operate or reset: 200 s max. (1) No timer, OFF-delay timer; or Timer selector (timer time: 40 ms (fixed)) Mutual interference prevention Up to 5 Amplifiers (optically synchronized) (2) Up to 5 Amplifiers (optically synchronized) (2) Ambient illumination Receiver side Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. Number of gang-mounted Amplifiers 16 max. (The ambient temperature specification depends on the number of gang-mounted Amplifiers.) Ambient temperature range Operating: Groups of 1 to 3 Amplifiers: -25C to 55C Groups of 4 to 11 Amplifiers: -25C to 50C Groups of 12 to 16 Amplifiers: -25C to 45C Storage: -30C to 70C (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Insulation resistance 20 M. min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute (3) Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions Degree of protection IEC 60529 IP50 (with Protective Cover attached) Connection method Pre-wired (standard cable length: 2 m), or connector None IEC 60529 IP66 (with Protective Cover attached) Weight (packed state) (4) Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g Material Case Polybutylene terephthalate (PBT) Cover Polycarbonate (PC) Accessories Polyethersulfone (PES) Instruction manual 1. When there are 8 or more E3X-NA Amplifiers mounted side-by-side, the response time will be 350 s max. 2. Mutual interference prevention is effective when E3X-SD/-NA-series Amplifiers are gang-mounted without other E3X-series Amplifiers. 3. Water-resistant models and models with connectors have a dielectric strength of 500 VAC. 4. Add 10 g for water-resistant models. Amplifier Unit Connectors (Wire-saving Connectors) Item Model E3X-CN11 E3X-CN12 Rated current 2.5 A Rated voltage 50 V Contact resistance 20 m max. (20 mVDC max., 100 mA max.) (The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) Number of insertions Material Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector) Housing Polybutylene terephthalate (PBT) Contact Phosphor bronze/gold-plated nickel Weight (packed state) Approx. 55 g Approx. 25 g 3 E3X-SD/-NA Sensing distance Amplifier Unit Fiber Unit Screw-shaped model Sensing Size method M3 Throughbeam models M4 Sensing direction Straight Right angle Straight Right angle M3 Straight M4 Reflective models Right angle M6 Straight Model E32-T21R 2M E32-T11N 2M E32-T11R 2M E32-TC200 2M E32-T11L 2M E32-C31N 2M E32-D21R 2M E32-C31 2M E32-D211R 2M E32-D11N 2M E32-C11N 2M E32-D11R 2M E32-DC200 2M E32-CC200 2M E32-D11L 2M Amplifier Unit Fiber Unit Flat model Sensing method Sensing direction Top view Throughbeam models Side view Flat view Top view Reflective models Side view Flat view Size Standard Small Standard Small Standard Small Standard Small Standard Small Standard Small Model E32-T15XR E32-T25XR E32-T15YR E32-T25YR E32-T15ZR E32-T25ZR E32-D15XR E32-D25XR E32-D15YR E32-D25YR E32-D15ZR E32-D25ZR 2M 2M 2M 2M 2M 2M 2M 2M 2M 2M 2M 2M Amplifier Unit Fiber Unit Cylindrical model Sensing Sensing method direction Throughbeam models Reflective models Top view Side view Top view Size 1 3 1 3 1.5 2 3 Side view 2 6 Model E32-T223R 2M E32-T12R 2M E32-T24R 2M E32-T14LR 2M E32-D22B 2M E32-D32 2M E32-D22R 2M E32-D32L 2M E32-D24R 2M E32-D14LR 2M Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 120 530 560 800 1,400 25 30 80 30 170 170 180 300 300 400 High-speed detection models 36 160 160 240 420 7.5 10 26 10 50 50 60 100 100 130 Water-resistance models 60 280 280 400 700 13 15 40 15 90 85 90 150 150 200 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 560 120 220 60 220 60 180 30 40 8 40 8 High-speed detection models 160 36 66 18 66 18 60 10 10 2.4 10 2.4 Water-resistance models 280 60 110 30 110 30 90 15 20 4 20 4 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 120 560 60 220 30 80 30 160 14 32 High-speed detection models 36 160 18 66 10 26 10 50 4.6 10 Water-resistance models 60 280 30 110 15 40 15 80 7 16 For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 4 E3X-SD/-NA Amplifier Unit Fiber Unit Model equipped with sleeve Sensing Sleeve size Mounting size method 0.25 x 5 3 Through0.5 x 40 beam 0.9 x 40 M3 models 1.2 x 90 M4 0.5 x 15 2 0.8 x 15 3 Reflective models 1.2 x 40 M3 2.5 x 90 M6 Model E32-T333-S5 1M E32-T33 1M E32-TC200F4R 2M E32-TC200BR 2M E32-D331 2M E32-D33 2M E32-DC200F4R 2M E32-DC200BR 2M Amplifier Unit Fiber Unit Movable section (Flexibility) Sensing Shape method Screw-shaped model Throughbeam models Cylindrical model Flat model Screw-shaped model Reflective models Cylindrical model Flat model Size M3 M4 1.5 3 Standard Small M3 M4 M6 1.5 3 Standard Small Model E32-T21 2M E32-T11 2M E32-T22B 2M E32-T12B 2M E32-T15XB 2M E32-T25XB 2M E32-D21 2M E32-D21B 2M E32-D11 2M E32-D22B 2M E32-D221B 2M E32-D15XB 2M E32-D25XB 2M Amplifier Unit Fiber Unit Heat-resistance model Sensing Operating method temperature 100C Throughbeam models 150C --Lens High-power lens --Lens High-power lens --- 200C 350C Reflective models Lens 100C 150C 200C 350C 400C Lens --High-power lens --- Model E32-T51R 2M E32-T51R 2M + E39-F1 E32-T51R 2M + E39-F16 E32-T51 2M E32-T51 2M + E39-F1-33 E32-T51 2M + E39-F16 E32-T54 2M E32-T81R-S 2M E32-T61-S 2M + E39-F1 E32-T61-S 2M E32-T61-S 2M + E39-F16 E32-D51R 2M E32-D51 2M E32-D81R 2M E32-D61 2M E32-D73 2M Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 10 40 120 560 3 16 30 180 High-speed detection models 3 13.5 36 160 1 4 10 60 Water-resistance models 5 20 60 280 1.5 10 15 90 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 200 720 200 720 720 150 30 70 180 30 70 180 50 High-speed detection models 60 200 60 200 200 40 10 20 60 10 20 60 16 Water-resistance models 100 360 100 360 360 75 15 35 90 15 35 90 25 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 400 2,000 4,000 800 2,400 4,000 260 360 4,000 600 4,000 140 240 90 90 60 High-speed detection models 120 720 1,560 240 720 3,120 70 100 1,800 180 2,340 42 80 27 27 18 Water-resistance models 225 1,650 2,900 400 1,400 4,000 130 180 3,000 300 3,900 70 120 45 45 30 The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 5 E3X-SD/-NA Amplifier Unit Fiber Unit Chemical-resistance / Oil-resistance model Sensing Type Model method 5 E32-T12F 2M 7.2 E32-T11F 2M 5 E32-T51F 2M Heat-resistance Through5 E32-T14F 2M beam Side view models M4 E32-T11U 2M Chemical-resistance cable M4 Right angle E32-T11NU 2M Chemical-resistance cable 6 E32-D12F 2M 7 Reflective E32-D14F 2M Side view models M6 E32-D11U 2M Chemical-resistance cable Amplifier Unit Fiber Unit Vacuum-resistance model Operating Sensing ambient method temperature Throughbeam models 120C 200C Sensing direction Top view Right angle Model E32-T51V 1M E32-T51V 1M + E39-F1V E32-T54V 1M E32-T84SV 1M Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 3,200 2,100 High-speed detection models 960 760 Water-resistance models 1,600 1,050 1,400 400 700 400 120 200 720 200 360 400 120 210 100 32 50 40 13 20 180 60 90 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@F E3X-NA@V E3X-NA@ Standard models High-speed detection models Water-resistance models 200 1,200 130 500 --------- 100 600 65 250 For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 6 E3X-SD/-NA Amplifier Unit Fiber Unit Long distance/Dust resistance (High-power), Detection through gaps (Narrow vision field) Sensing Sensing direction/ Type Model method Lens type Top view E32-T17L 10M High-power (integrated unit) Side view E32-T14 2M High-power E32-T11N 2M + E39-F1 Ultrahigh-power E32-T11N 2M + E39-F16 High-power E32-T11R 2M + E39-F1 Ultrahigh-power E32-T11R 2M + E39-F16 Side view E32-T11R 2M + E39-F2 High-power E32-TC200 2M + E39-F1 Ultrahigh-power E32-TC200 2M + E39-F16 Side view E32-TC200 2M + E39-F2 High-power E32-T11 2M + E39-F1 Ultrahigh-power E32-T11 2M + E39-F16 ThroughSide view E32-T11 2M + E39-F2 High-power beam (with lens unit) High-power E32-T11U 2M + E39-F1 models Ultrahigh-power E32-T11U 2M + E39-F16 Side view E32-T11U 2M + E39-F2 High-power E32-T11NU 2M + E39-F1 Ultrahigh-power E32-T11NU 2M + E39-F16 High-power E32-T81R-S 2M + E39-F1 Ultrahigh-power E32-T81R-S 2M + E39-F16 Side view E32-T81R-S 2M + E39-F2 High-power E32-T61-S 2M + E39-F1 Ultrahigh-power E32-T61-S 2M + E39-F16 Side view E32-T61-S 2M + E39-F2 Narrow vision Top view E32-T22S 2M field (aperture Side view E32-T24S 2M angle: 4) Reflective High-power Top view E32-D16 2M models Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models High-speed detection models Water-resistance models 20,000 1 3,600 3,700 4,000 2 4,000 2 4,000 2 440 4,000 2 4,000 2 700 4,000 2 4,000 2 720 3,600 4,000 2 660 1,800 4,000 2 1,800 4,000 2 280 4,000 2 4,000 2 780 2,000 8,400 1,080 1,110 2,000 1,260 2,000 130 1,800 3,000 210 1,200 2,600 200 1,080 2,600 198 700 1,500 630 1,300 84 1,800 2,340 260 600 1,400 420 800 140 14,000 1,800 2,100 3,600 2,100 3,600 220 3,000 4,000 2 350 2,000 4,000 2 360 2,000 4,000 2 330 1,500 2,700 1,100 2,300 140 3,000 3,900 390 1,000 700 40 to 400 1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. 2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Amplifier Unit Fiber Unit Minute object detection (Small-spot model) Sensing Spot diameter Focal length Model method (mm) (mm) 0.1 to 0.6 6 to 15 E32-C42 1M + E39-F3A (Variable) 5 E32-C42S 1M 0.1 7 E32-C41 1M + E39-F3A-5 0.2 17 E32-C41 1M + E39-F3B 7 E32-C31 2M + E39-F3A-5 Reflective 0.5 models 17 E32-C31 2M + E39-F3B 6 50 E32-L15 2M 4 0 to 20 E32-C31 2M + E39-F3C Parallel light E32-C11N 2M + E39-F18 3 50 E32-CC200 2M + E39-F18 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models High-speed detection models Water-resistance models Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm Spot diameter of 0.1 mm at 5 mm Spot diameter of 0.1 mm at 7 mm Spot diameter of 0.2 mm at 17 mm Spot diameter of 0.5 mm at 7 mm Spot diameter of 0.5 mm at 17 mm Spot diameter of 6 mm at 50 mm Spot diameter of 4 mm max. at 0 to 20 mm Spot diameter of 3 mm at 50 mm Spot diameter of 3 mm at 50 mm For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 7 E3X-SD/-NA Amplifier Unit Fiber Unit Area-sensing (Area beam) Sensing Area range method Throughbeam models Reflective models 11 mm Sensing direction Side view Flat view 30 mm 11 mm Side view Model E32-T16PR 2M E32-T16JR 2M E32-T16WR 2M E32-D36P1 2M Amplifier Unit Fiber Unit Detection without background interference (Convergent-reflective) Sensing Sensing Size Model method detection Standard E32-L16-N 2M Flat view Small E32-L24S 2M Reflective models Top view E32-L25L 2M --Flat view E32-L24L 2M Amplifier Unit Fiber Unit Detection of transparent objects (Retro-reflective) Sensing Type Model method Square E32-R16 5M + E39-R1 (Attached) Small E32-R21 2M + E39-R3 (Attached) Retroreflective E32-C31 2M models + E39-F3R + E39-RP1 Film detection 2 1 E32-C31 2M + E39-F3R + E39-RSP1 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 800 700 1,380 High-speed detection models 260 220 400 Water-resistance models 450 390 690 50 75 150 Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ Standard models 0 to 15 5.4 to 9 (Center 7.2) E3X-NA@F E3X-NA@V High-speed detection models 0 to 12 0 to 4 5.4 to 8 (Center 7.2) 2 to 6 (Center 4) Water-resistance models 0 to 15 5.4 to 9 (Center 7.2) Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models 1,500 10 to 250 High-speed detection models 1,000 250 Water-resistance models 150 to 1,500 10 to 250 450 135 225 220 65 110 1. When using a highly reflective object, light reflected from the object may affect the Sensor. 2. Film detection may not be effective for some types of film. Confirm operation in advance. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 8 E3X-SD/-NA Amplifier Unit Fiber Unit FPD / Semiconductor / Solar battery industry Sensing Operating Application Model method temperature E32-L16-N 2M Glass 70C substrate E32-A08 2M alignment 300C E32-A08H2 3M Glass detection 70C E32-L16-N 2M 70C E32-A09 2M Glass substrate 150C E32-A09H 2M mapping 300C E32-A09H2 2M Reflective models WET process Throughbeam models Wafer mapping 60C E32-L11FP 5M 70C E32-L12FS 5M 85C E32-L11FS 5M 70C E32-A03 2M E32-A03-1 2M E32-A04 2M E32-A04-1 2M Sensing distance (Unit: mm) E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Standard models High-speed Water-resistance detection models models 0 to 15 10 to 20 10 to 20 0 to 15 15 to 38 (Center 25) 15 to 38 (Center 25) 20 to 30 (Center 25) 8 to 20 mm from end of lens (recommended: 11 mm) 19 to 31 mm from center point A of mounting hole (recommended: 22 mm) 8 to 20 mm from end of lens (recommended: 11 mm) 32 to 44 mm from center point A of mounting hole (recommended: 35 mm) 8 to 20 mm from end of lens (recommended: 11 mm) 32 to 44 mm from center point A of mounting hole (recommended: 35 mm) 890 267 445 890 267 445 340 102 170 340 102 170 Amplifier Unit Sensing distance (Unit: mm) Fiber Unit E3X-SD@ E3X-NA@F E3X-NA@V E3X-NA@ Liquid-level detection model Sensing Sensing Standard High-speed Water-resistance Pipe diameter Model method direction models detection models models No limit E32-D36T 5M Applicable pipe: Transparent (no restriction on diameter) Mounted to Reflective Applicable pipe: Transparent pipe with diameter of 8 to pipe 8 to 10 mm E32-L25T 2M models 10 mm, recommended pipe wall thickness: 1 mm Wet --E32-D82F1 4M Wet model For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 9 E3X-SD/-NA I/O Circuit Diagrams Output form Output transistor operation mode Model Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Light-ON E3X-SD21 E3X-SD7 NPN Output Operation selector Timing charts Output circuit Brown LIGHT ON (L-ON) Load Photoelectric Sensor main circuit Operate Load (relay) 1 Operation indicator (orange) T Control output Reset (Between brown and black leads) E3X-NA11 E3X-NA6 E3X-NA11F E3X-NA11V E3X-NA14V Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Dark-ON Blue T * M8 Connector Pin Arrangement DARK ON (D-ON) Light-ON E3X-SD51 E3X-SD9 3 Brown T LIGHT ON (L-ON) Operation indicator (orange) Operate Reset (Between blue and black leads) Incident light No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (relay) Reset (Between blue and black leads) Dark-ON 4 Not present on the E3X-NA. Load (relay) E3X-NA41 E3X-NA8 E3X-NA41F E3X-NA41V E3X-NA44V 2 1 Note: Pin 2 is not used. Operate Reset (Between brown and black leads) Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF 1 Photoelectric Sensor main circuit Black Control output 4 Load Blue * M8 Connector Pin Arrangement DARK ON (D-ON) 2 1 4 3 Note: Pin 2 is not used. Not present on the E3X-NA. OFF delay ON OFF ON D-ON OFF T L-ON T Plug (Sensor I/O Connector) Terminal number 4 3 2 1 Brown White Blue Black XS3F-M421-402-A XS3F-M421-405-A 10 Wire color 1 2 3 4 XS3F-M422-402-A XS3F-M422-405-A 12 to 24 VDC 3 Note: Timing Charts for Timer Settings (T: Set Time) Incident light No incident light 12 to 24 VDC 3 Load (relay) PNP Output Black 4 Classification DC Note: Pin 2 is not used. Wire color Connection pin Application Brown 1 Power supply (+V) White 2 --- Blue 3 Power supply (0 V) Black 4 Output E3X-SD/-NA Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Caution Do not exceed the rated voltage. Excess voltage may result in malfunction or fire. Do not use an AC power supply. Using an AC power supply may result in rupturing. High-temperature environments may result in burn injury. Precautions for Safe Use The following precautions must be observed to ensure safety. 1. Do not use the product in locations where flammable or explosive gas is present. 2. Do not use the product in locations subject to splashing water, oil, or chemicals, or in locations subject to steam. 3. Do not attempt to disassemble, repair, or modify the product. 4. Do not apply voltage or current in excess of the rated ranges. 5. Do not use the product in atmospheres or environments that exceed product ratings. 6. Do not wire the product incorrectly, such as using incorrect power supply polarity. 7. Connect the load properly. 8. Do not short-circuit both ends of the load. 9. Do not use the product if the case is damaged. 10. When disposing of the product, dispose of it as industrial waste. 11. Do not use the product in locations subject to direct sunlight. 12. The surface temperature of the product may rise as a result of the ambient temperature, power supply, or other usage conditions. Use caution when performing maintenance and washing. Failure to do so may result in burn injury. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Amplifier Units Designing Communications Hole The hole on the side of the Amplifier Unit is a communications hole for preventing mutual interference when Amplifier Units are mounted side-by-side. The E3X-MC11 Mobile Console (sold separately) cannot be used. If an excessive amount of light is received via the Sensor, the mutual interference prevention function may not work. In this case, make the appropriate adjustments using the sensitivity adjuster. Mutual interference prevention is effective when E3X-SD/NA-series Amplifiers are gang-mounted without other E3Xseries Amplifiers. Mounting DIN Track Mounting/Removal Mounting Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN track. 2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place. Clip Click into place Removing Amplifier Units Slide Amplifier Units away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifier Units from the DIN track without separating them first.) Note 1. The specifications for ambient temperature will vary according to the number of Amplifier Units used together. For details, refer to Ratings and Specifications. 2. Always turn OFF the power supply before mounting or removing Amplifier Units. 11 E3X-SD/-NA Fiber Connection and Disconnection The E3X Amplifier Unit has a lock lever. Connect or disconnect the fibers to or from the E3X Amplifier Unit using the following procedures: 1. Connection Open the Protective Cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock lever. Insertion position Lock lever Fiber Fiber insertion mark 10.7 mm Sticker Removing Connectors 1. Slide the slave Amplifier Unit for which the Connector is to be removed away from the rest of the group. 2. After the Amplifier Unit has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first.) Press down Lever Note: If one of the fibers from the Fiber Unit has a white line, such as with a Coaxial Sensor, that fiber is for the Emitter. Insert it into the Emitter section. Refer to Dimensions for the Fiber Unit to see if there is an Emitter fiber. 2. Disconnection Remove the Protective Cover and raise the lock lever to pull out the fiber. Protective Cover Locked Unlocked Note:To maintain the fiber properties, confirm that the lock is released before removing the fiber. 3. Precautions for Fiber Connection/Disconnection Be sure to lock or unlock the lock lever within an ambient temperature range between -10C and 40C. Operating Environment Ambient Conditions If dust or dirt adhere to the hole for optical communications, it may prevent normal communications. Be sure to remove any dust or dirt before using the Units. Sticker Note: Attach the stickers to the sides with grooves. Remove Mounting End Plate (PFP-M) Depending on how it is mounted, an Amplifier Unit may move during operation. In this case, use an End Plate. Before mounting an End Plate, remove the clip from the master Amplifier Unit using a nipper or similar tool. Clip The clip can also be removed using the following mechanism, which is incorporated in the construction of the section underneath the clip. 1. Insert the clip to be removed into the slit underneath the clip on another Amplifier Unit. Other Protective Cover Be sure to mount the Protective Cover before use. Amplifier Units with Connectors Mounting Mounting Connectors 1. Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place. 2. Remove the clip by rotating the Amplifier Unit. Rotate Insert 2. Join Amplifier Units together as required after all the Master and Slave Connectors have been inserted. 3. Attach the stickers (provided as accessories) to the sides of Master and Slave Connectors that are not connected to other Connectors. 12 Pull Strengths for Connectors (Including Cables) E3X-CN11: 30 N max. E3X-CN12: 12 N max. E3X-SD/-NA (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this sheet unless otherwise specified. Amplifier Units Amplifier Units with Cables E3X-SD21 10 E3X-SD51 E3X-NA11 E3X-NA11F E3X-NA41 E3X-NA41F 15 Vinyl-insulated round cable 4 dia. cable / 3 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) Operation indicator DIN track mounting 3 128.95 180 93.75 Hole for optical communications 31.5 8 (9) 10.7 10.75 Two, 2.4 dia. 3.4 2.4 13 Multiple connection diagram 4 30.4 End Plate (sold separately) PFP-M 12.4 L 64.3 Center of DIN track DIN track (sold separately) PFP-@N 10 Fiber Attachment mounted (E39-F9) 10 The number of expansion L (mm) 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 10 9 90 10 100 With Mounting Bracket Attached 3 128.95 180 93.75 Hole for optical communications 31.5 8 (9) 10.7 10.75 Two, 2.4 dia. 3.4 2.4 Two, 3.2 dia. holes 4.3 13 (9.4) 4 16 64.3 Mounting Bracket (E39-L143) SUS304 stainless steel (sold separately) Mounting Holes Two, M3 3.4 4.4 16 22.4 16 There is no hole for E3X-NA@F models. Fiber Attachment mounted (E39-F9) Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side. 13 E3X-SD/-NA Amplifier Units with Connectors E3X-SD7 10 E3X-SD9 E3X-NA6 E3X-NA8 15 Operation indicator DIN track mounting 3 128.95 180 93.75 31.5 8 Hole for optical communications A dia. (9) 12.95 10.7 Two, 2.4 dia. 3.4 Multiple connection diagram 13 30.4 End Plate (sold separately) PFP-M 12.4 L 64.3 Center of DIN track DIN track (sold separately) PFP-@N 10 Fiber Attachment mounted (E39-F9) 10 The number of expansion L (mm) 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 10 9 90 10 100 With Mounting Bracket Attached 3 128.95 180 93.75 31.5 8 Hole for optical communications A dia. (9) 12.95 10.7 Two, 2.4 dia. 3.4 Two, 3.2 dia. holes 4.3 13 (9.4) 16 64.3 Mounting Bracket (E39-L143) SUS304 stainless steel (sold separately) Mounting Holes Two, M3 3.4 4.4 Cable Diameters 16 22.4 E3X-CN11 (3 conductors) 4.0 dia. E3X-CN12 (1 conductor) 2.6 dia. 16 Fiber Attachment mounted (E39-F9) Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side. 14 E3X-SD/-NA Amplifier Units with Cables, Water-resistant Models E3X-NA11V 12 E3X-NA41V Area of digital indication 28.65 25.95 9.2 Vinyl-insulated round cable Operation indicator 4 dia. cable / 3 conductors / Standard length: 2 m (Conductor cross section: 0.45 mm2, Insulator diameter: 1.1 mm) Incident level indicators DIN track mounting 6.9 152.3 105.9 180 33 (9) 8 11.2 10.7 Two, 2.4 dia. 3.4 Hole for optical communications 14.4 31.9 18 Multiple connection diagram 67.2 End Plate (sold separately) PFP-M L Center of DIN track DIN track (sold separately) PFP-@N 10 Fiber Attachment mounted (E39-F9) 12 10 The number of expansion L (mm) 1 12 2 24 3 36 4 48 5 60 6 72 7 84 8 96 9 108 10 120 With Mounting Bracket Attached 6.9 152.3 105.9 180 33 (9) 8 11.2 10.7 Two, 2.4 dia. 3.4 Hole for optical communications 4.3 14.4 9.5 16 67.2 6.6 Mounting Bracket (E39-L148) SUS304 stainless steel (sold separately) Mounting Holes Two, M3 3.4 5.4 16 23.9 16 Fiber Attachment mounted (E39-F9) 15 E3X-SD/-NA Amplifier Units with Connectors, Water-resistant Models E3X-NA14V E3X-NA44V 12 Area of digital indication 28.65 25.95 9.2 Operation indicator Incident level indicators DIN track mounting 6.9 152.3 105.9 180 33 (9) 8 11.2 10.7 Two, 2.4 dia. 3.4 Hole for optical communications 14.4 31.9 18 Multiple connection diagram 67.2 End Plate (sold separately) PFP-M L Center of DIN track DIN track (sold separately) PFP-@N 10 Fiber Attachment mounted (E39-F9) 12 10 The number of expansion L (mm) 1 12 2 24 3 36 4 48 5 60 6 72 7 84 8 96 9 108 10 120 With Mounting Bracket Attached 6.9 152.3 105.9 180 33 (9) 8 11.2 10.7 Two, 2.4 dia. 3.4 Hole for optical communications 4.3 14.4 9.5 16 67.2 Mounting Holes Two, M3 3.4 5.4 16 23.9 16 Fiber Attachment mounted (E39-F9) 16 11 Mounting Bracket (E39-L148) SUS304 stainless steel (sold separately) E3X-SD/-NA Amplifier Unit Connectors (Wire-saving Connectors) Master Connector E3X-CN11 2,000 +500 Edge of amplifier (7) E3X-CN11: 4 dia. cable / 3 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Slave Connector E3X-CN12 2,000 +500 Edge of amplifier (7) E3X-CN12: 2.6 dia. cable / 1 conductor / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Accessories (sold separately) Mounting Brackets E39-L143 34.8 22 16 2.5 (10.3) 3 Mounting Holes Two, M3 7.3 5.3 26.8 Two, 3.2 dia. 3 16 7 160.1 3 Four, R1.7 3.4 10.3 10 max. 7 Material: Stainless steel (SUS304) 1 3.4 End Plates PFP-M 11.5 1 50 M4 x 8 panhead screw 10 M4 spring washer 4.8 6.2 10 1 1.3 1.8 35.5 1.8 35.3 17 E3X-SD/-NA Nomenclature Amplifier Units E3X-SD E3X-NA Digital incident light level display or digital threshold value display (red) Digital threshold value adjustment Display of contents of functions (UP/DOWN) during operation Operation Selector Teaching status Use to switch between indication(orange) Light-ON and Dark-ON Operation Indicator Light-ON and (Orange) Dark-ON Indicator Lock Lever Teaching Button The sensitivity and threshold value can be set automatically. Sensitivity indicator 8-turn sensitivity adjuster Lock lever Incident level indicators Operation Indicator Operation Selector Use to switch between Light-ON and Dark-ON Timer switch ON: Timer function is ON. OFF: Timer function is OFF. Operating Procedure E3X-SD E3X-NA 1 Sensitivity Setting The sensitivity can be set with the UP and DOWN Keys similar to using an adjuster knob. The sensitivity can also be easily set by using the following two teaching functions. 2-1. Teaching with/without a Workpiece Two points (one with the workpiece and the other without) are detected, and the operating level is set to the midpoint. Light level is also automatically set to the optimal value. Operation description Press the TEACH button with the workpiece. Press the TEACH button without the workpiece. Press the TEACH button for 3 s min. Let the workpiece pass while the button is pressed. 18 Displays A bar display (with four green and one red) showing excess gain is provided in addition to the orange operation indicator. Use these when adjusting the light axis and setting the sensitivity at setup. Display/indicator status (for L/ON) TEACH TEACH Excess gain level Approx. 120% min. Stable incident light Excess gain level display Approx. 110% to 120% Approx. 90% to 110% Unstable incident light or Unstable interrupted light Approx. 80% to 90% Stable interrupted light Button/Key TEACH Description Operation indicator Button/Key 2-2. Automatic Teaching Changes within a time are detected, and the operating level is set to the midpoint between the maximum and the minimum values of the changes. This setting is optimal for when the workpieces cannot be stopped. Execute automatic teaching again if the incident light level is not automatically set to the optimal value. Operation description 1 Approx. 80% max. READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. This document provides information mainly for selecting suitable models. Please read the Instruction sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2010 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_3_1_1010 Cat. No. E401-E1-01 0110