littelfuse.com © 2015 Littelfuse POWR-GARD® Products
Rev: 082715
POWR-GARD® Fuse Datasheet
1 of 3
Part Numbering System
SERIES AMP PACKAGE
QUANTITY
CATALOG
NUMBER
ORDERING
NUMBER
0KLK 1/8 10 0KLK.125 0KLK.125T
0KLK 5100 0KLK005 0KLK005.H
Specifications
Voltage Rating: 600 Vac / 500 Vdc
Amperage Rating:
1
/10, 1
/8, 2/10, 1
/4, 3/10, 1
/2, 3/4, 1, 11
/2, 2, 21
/2, 3,
31
/2, 4, 5, 6, 7, 8, 9,10, 12, 15, 20, 25, 30
Interrupting Ratings: AC: 100 kA
200 kA Littelfuse self-certified
DC: 50 kA
Material: Body: Melamine / Caps: Copper Alloy
Operating Temperature: See Rerating Curve
Approvals: UL 248-14 Listed (File: E10480)
CSA Certified (File: LR29862)
QPL (File: F60C)
CE
Country of Origin: Mexico
Environmental: RoHS Compliant
Description
Fast-Acting, High-Interrupting Capacity, Current-Limiting
Type Fuse. Especially suited for control circuits, street
lighting, HID lighting, computers, and other applications
without high in-rush currents.
Features/Benefits
• UL approved
• 1/10 - 30 A ratings available
• 100,000 A Interrupting Rating
Applications
• Control Circuits
• Street lighting, HID lighting
• Computers
Dimensions Inches (mm)
Recommended Fuse Holders
Littelfuse LFPSM Dead-Front Series
Littelfuse LEB Series
Littelfuse L60030M Series
Web Resources
Download CAD drawings and other technical information:
littelfuse.com/klk
KLK SERIES 10x38 FUSES
600 Vac/500 Vdc • 1/10-30 A • Fast Acting
0KLK xxx H
Package Quantity
Series
Amp Code
T = 10
H = 100
Refer to Amp Code
Column in Electrical
Specifications Table
1
Cartridge and Axial Lead Fuses
©2015 Littelfuse, Inc.
Specifications are subject to change without notice. Revised: February 20, 2015
KLK Series
AC > Fast-Acting Type > KLK Series
KLK Series, AC, Fast-Acting Midget/5AG Size Fuse
Agency Approvals
Agency Agency File Number Ampere Range
E10480 .3A - 30A
F60C
Electrical Characteristics for Series
Fast-Acting, High-Interrupting Capacity, Current-Limiting
Type Fuse. Especially suited for control circuits, street
lighting, H.I.D. lighting, computers, and other applications
without high in-rush currents.
% of Ampere
Rating Ampere Rating Opening Time
100% 0–30 Until temp stabilizes
135% 0–30 1 hours, Maximum
200% 0–30 2 minutes, Maximum.
Ordering
Number
Amp
Rating
(A)
Max
Voltage
Rating
(V)
Interrupting
Rating
Nominal
Cold
Resistance
(Ohms)
Agency Approvals
KLK .100 .100
600 100,000
amperes
(capable of
200,000) at
600VAC.
85.5 x x x
KLK .125 .125 65.0 x x x
KLK .200 .200 30.9 x x x
KLK .250 .250 22.0 x x x
KLK .300 .300 16.2 x x x
KLK .500 .500 7.99 x x x
KLK .750 .750 .398 x x x
KLK 001 1 .249 x x x
KLK 01.5 1. 5 .132 x x x
KLK 002 2 .129 x x x
KLK 02.5 2.5 .0989 x x x
KLK 003 3 .0773 x x x
KLK 03.5 3.5 .0613 x x x
KLK 004 4 .0511 x x x
KLK 005 5 .0357 x x x
KLK 006 6 .0261 x x x
KLK 007 7 .0205 x x x
KLK 008 8 .0194 x x x
KLK 009 9 .0166 x x x
KLK 010 10 .0128 x x x
KLK 012 12 .0103 x x x
KLK 015 15 .0073 x x x
KLK 020 20 .00421 x x x
KLK 025 25 .00329 x x x
KLK 030 30 .00267 x x x
Electrical Specifications by Item
Temperature Rerating Curve
Product Characteristics
Military Type F60C
Interrupting Rating
200,000 amperes at 500VAC
150,000 amperes at 500vDC
(1.50") 10.31
(.406")
-60°C -40°C -20°C 0°C 20°C 40°C 60°C 80°C 100°C 120°C 140°C
-76°F -40°F -4°F 32°F 68°F 104°F 140°F 176°F 212°F 248°F 284°F
AMBIENT TEMPERATURE
60
40
20
0
PERCENT OF UPRATING
0
20
40
60
PERCENT OF DOWNRATING
Temperature Derating Curve (Temperature