4 Industrial Control Transformers International Series Control Transformers: 50 - 750 VA Electromagnetic control components demand inrush currents up to 10 times the transformers nominal rating without sacrificing secondary voltage stability beyond practical limits. The International series transformers fully comply with IEC and NEMA standards and are available with IEC touchproof covers (IP20). Features * Epoxy encapsulated for cooler operation * Interleaved copper windings to reduce impedence * 50/60 Hz * 55C Rise, 105C insulation system for harsh, heavy duty applications * Exceeds IEC, NEMA, ANSI, NMTBA, JIC and automotive standards Certifications and Compliances * E77014 Listed: E77014 - UL 506 - CSA C22.2 No. 66 * - IEC 61558-1, IEC 61558-2-2 * RoHS Compliant Related Products * DIN Rail Power Supplies * 63 Series Power Conditioners * Surge Protective Devices Catalog Number Field Installed options Descriptions DIN Circuit Breaker Mounting SBEDIN Field installed IEC fuse holder adaptor kit Terminal Covers (Two Covers Per Kit) IP20 190 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. Field installed primary and secondary IEC Touch Proof Cover Kit. 4 Industrial Control Transformers Selection Tables: International Series Group 1 - 208/240/415 Volt Primary, 120/24 Secondary, 50/60 Hz 200/230/400 Volt Primary, 115/23 Secondary, 50/60 Hz Continuous Instantaneous VA VA * Catalog Height Width Depth Mtg Width Mtg Depth Number in (mm) in (mm) in (mm) W1 / W2 - in (mm) D1 / D2 - in (mm) Slot Size S1/S2 - in (mm) Approx. Ship Weight lbs (kg) 50 105 E050TC 2.96 (75.2) 3.39 4.36 (86.1) (110.7) 2.81 / 2.50 (71.4 / 63.5) 2.10 / N/A (53.3 / N/A) .20 x .50 / .20 x .50 (5.08 x 12.7 / 5.08 x 12.7) 4.0 (1.82) 100 230 E100TC 3.89 4.50 4.48 (98.8) (114.3) (113.8) 2.56 / 2.87 (65.0 / 72.9) 2.87 / 3.18 (72.9 / 80.8) .20 x .65 / .20 x .33 (5.08 x 16.5 / 5.08 x 8.4) 8.0 (3.67) 150 420 E150TC 3.89 4.50 5.21 (98.8) (114.3) (132.3) 3.74 / 3.12 (95.0 / 79.3) 3.29 / 3.61 (83.6 / 91.7) .20 x .65 / .20 x .33 (5.08 x 16.5 / 5.08 x 8.4) 11.0 (5.00) 250 675 4.53 5.25 5.07 E250TC (115.1) (133.4) (128.8) 4.38 / 3.75 (111.3 / 95.3) 3.54 / N/A (89.9 / N/A) 500 1600 5.56 6.38 6.93 E500TC (141.2) (162.1) (176.0) 5.32 / 4.37 (135.1 / 111.0) 4.25 / 5.75 (108.0 / 146.1) .31 x .85 / .31 x .85 15.0 (6.82) (7.87 x 21.59 / 7.87 x 21.59 .31 x .03 / .31 x .85 30.0 (13.64) (7.87 x .85 / 7.87 x 21.59) * At 50% PF (Power Factor), 95% Nominal Secondary Voltage. Group 2 - 208/240/415 Volt Primary, 24 Volt Secondary, 50/60 Hz 277/480 Volt Primary, 24 Volt Secondary, 60 Hz 200/230/400 Volt Primary, 24 Volt Secondary, 50/60 Hz 220/380 Volt Primary, 23 Volt Secondary, 50/60 Hz Continuous Instantaneous VA VA* Catalog Height Width Depth Number in (mm) in (mm) in (mm) Mtg Width W1 / W2 in (mm) Mtg Depth D1 / D2 in (mm) Slot Size S1/S2 - in (mm) Approx. Ship Weight lbs (kg) 50 105 E050TE 2.96 (75.2) 3.39 4.36 (86.1) (110.7) 2.81 / 2.50 (71.4 / 63.5) 2.10 / N/A (53.3 / N/A) .20 x .50 / .20 x .50 (5.08 x 12.7 / 5.08 x 12.7) 4.0 (1.82) 100 230 E100TE 3.89 4.50 4.48 (98.8) (114.3) (113.8) 2.56 / 2.87 (65.0 / 72.9) 2.87 / 3.18 (72.9 / 80.8) .20 x .03 / .20 x .01 (5.08 x .65 / 5.08 x .33) 8.0 (3.67) 150 420 E150TE 3.89 4.50 5.21 (98.8) (114.3) (132.3) 3.74 / 3.12 (95.0 / 79.3) 3.29 / 3.61 (83.6 / 91.7) .20 x .03 / .20 x .01 (5.08 x .65 / 5.08 x .33) 11.0 (5.00) 250 675 E250TE 4.53 5.25 5.07 (115.1) (133.4) (128.8) 4.38 / 3.75 (111.3 / 95.3) 3.54 / N/A (89.9 / N/A) .30 x .71 / .30 x .71 (7.87 x 18.0 / 7.87 x 18.0) 15.0 (6.82) 500 1600 E500TE 5.56 6.38 6.93 (141.2) (162.1) (176.0) 5.32 / 4.37 (135.1 / 111.0) 4.25 / 5.75 (108.0 / 146.1) .30 x .85 / .30 x .85 30.0 (13.64) (7.87 x 21.6 / 7.87 x 21.6) Note: Fuse holders are not available for these voltage configurations. * At 50% PF (Power Factor), 95% Nominal Secondary Voltage. Design Style Mounting Dimensions Profile Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. Top View 191 4 Industrial Control Transformers Selection Tables: International Series - continued Group 3 - 208/240/415/480/600 * Volt Primary, 120 Volt Secondary, 50/60 Hz 200/230/400/460/575 * Volt Primary, 115 Volt Secondary, 50/60 Hz 220/277 */380 Volt Primary, 110 Volt Secondary, 50/60 Hz Continuous Instantaneous VA VA ** 50 93 100 205 150 390 250 630 Catalog Height Width Depth Mtg Width Mtg Depth Number in (mm) in (mm) in (mm) W1 / W2 - in (mm) D1 / D2 - in (mm) Slot Size S1/S2 - in (mm) Approx. Ship Weight lbs (kg) E050TF 2.96 (75.2) 3.39 4.36 (86.1) (110.7) 2.81 / 2.50 (71.4 / 63.5) 2.10 / N/A (53.3 / N/A) .20 x .50 / .20 x .50 (5.08 x 12.7 / 5.08 x 12.7) 4.0 (1.82) E100TF 3.89 4.50 4.48 (98.8) (114.3) (113.8) 3.74 / 3.12 (95.0 / 79.3) 2.56 / 2.87 (65.0 / 73.0) .20 x .65 / .20 x .33 (5.08 x 16.5 / 5.08 x 8.38) 8.0 (3.67) E150TF 3.89 4.50 5.21 (98.8) (114.3) (132.3) 3.74 / 3.12 (95.0 / 79.3) 3.29 / 3.61 (83.6 / 91.7) .20 x .65 / .20 x .33 (5.08 x 16.5 / 5.08 x 8.38) 11.0 (5.00) E250TF 4.53 5.25 5.07 (115.1) (133.4) (128.8) 4.38 / 3.75 (111.3 / 95.3) 3.54 / N/A (89.9 / N/A) .31 x .71 / .31 x .71 (7.9 x 18.0 / 7.9 x 18.0) 15.0 (6.82) 5.32 / 4.37 (135.1 / 111.0) 4.25 / 5.75 (108.0 / 146.1) .31 x .85 / .31 x .85 (7.9 x 21.6 / 7.9 x 21.6) 30.0 (13.64) 5.32 / 4.37 (135.1 / 111.0) 4.68 / 6.18 (118.9 / 157.0) .31 x .85 / .31 x .85 (7.9 x 21.6 / 7.9 x 21.6) 34.0 (15.45) 500 1200 E500TF 5.56 6.38 6.93 (141.2) (162.1) (176.0) 750 2290 E750TF 5.56 6.38 7.36 (141.2) (162.1) (187.0) H4 X4 120 (415/208) 115 (400/200) 110 (380) 200-277 H1 H3 H2 H4 X3 H2 120 (480/240) 115 (460/230) 110 (220) H3 X2 120 (600) 115 (575) 110 (277) 380-600 H2 H4 H1 H3 H1 50/60 Hz 60 Hz Only X1 0 * 60 Hz Only. ** At 50% PF (Power Factor), 95% Nominal Secondary Voltage. Group 4 - 240/415/480 Volt Primary, 120/240 Volt Secondary, 50/60 Hz 230/400/460 Volt Primary, 115/230 Volt Secondary, 50/60 Hz 220/380/440 Volt Primary, 110/220 Volt Secondary, 50/60 Hz Continuous Instantaneous VA VA* 50 110 100 235 150 470 Catalog Height Width Depth Number in (mm) in (mm) in (mm) Mtg Width W1 / W2 in (mm) Mtg Depth D1 / D2 in (mm) Slot Size S1/S2 - in (mm) Approx. Ship Weight lbs (kg) 4.0 (1.82) E050TH 2.96 (75.2) 3.39 4.36 (86.1) (110.7) 2.81 / 2.50 (71.4 / 63.5) 2.10 / N/A (53.3 / N/A) .20 x .50 / .20 x .50 (5.08 x 12.7 / 5.08 x 12.7) E100TH 3.89 4.50 4.48 (98.8) (114.3) (113.8) 3.74 / 3.12 (95.0 / 79.3) 2.56 / 2.87 (65.0 / 73.0) .20 x .65 / .20 x .33 (5.08 x 16.5 / 5.08 x 8.38) 8.0 (3.67) E150TH 3.89 4.50 5.21 (98.8) (114.3) (132.3) 3.74 / 3.12 (95.0 / 79.3) 3.29 / 3.61 (83.6 / 91.7) .20 x .65 / .20 x .33 (5.08 x 16.5 / 5.08 x 8.38) 11.0 (5.00) 4.38 / 3.75 (111.3 / 95.3) 3.54 / N/A (89.9 / N/A) .31 x .81 / .31 x .85 (7.9 x 20.59 / 7.9 x 18.0) H4 X4 440/460/480 H3 X1 X3 X2 X4 H2 X2 X3 220/230/240 250 730 E250TH 4.53 5.25 5.07 (115.1) (133.4) (128.8) 500 1670 E500TH 5.56 6.38 6.93 (141.2) (162.1) (176.0) 5.32 / 4.37 (135.1 / 111.0) 4.25 / 5.75 (108.0 / 146.1) .31 x .85 / .31 x .85 30.0 (13.64) (7.9 x 21.59 / 7.9 x 21.59) 750 2250 E750TH 5.56 6.38 7.36 (141.2) (162.1) (187.0) 5.32 / 4.37 (135.1 / 111.0) 4.68 / 6.18 (118.9 / 157.0) .31 x .85 / .31 x .85 34.0 (15.45) (7.9 x 21.59 / 7.9 x 21.59) X1 X3 X2 X4 15.0 (6.82) X1 H1 0 50/60 Hz Note: Fuse holders are not available for these voltage configurations. * At 50% PF (Power Factor), 95% Nominal Secondary Voltage. International Series - Fuse Recommendations Primary Fusing: Consult local Electrical Code. Secondary Fusing: per IEC EN61558-2-2. * See 500 VA fuse rating for MC design. VA 50 Maximum Current Rating of Fuse 24 Vac 115 Vac 230 Vac 2 0.5 0.25 100 4 1 0.5 150 6 1.6 0.8 250 10 2 1 500 20 4 2 4 750 * 6 1000 * 8 4 1500 * 12 6 2000 - 16 8 * See 500 VA fuse rating for MC design. 192 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 120 (480/415/240) 115 (460/400/230) 110 (440/380/220) 380/400/415 0 240 (480/415/240) 230 (460/400/230) 220 (440/380/220) 4 Industrial Control Transformers ICE International Series: 750 - 2000 VA International CE marked transformers include IP20 touchproof terminations and copper windings in an encapsulated design. These units range from 750 to 2000 VA with 80oC temperature rise. The design is highly flexible due to the use of the standardized primary coil for multiple worldwide voltage combinations. CE marked and cULus approval make the ICE International Series the perfect choice for OEM export equipment. Features * IP20 Touch-Proof terminals * Copper windings * Epoxy encapsulated for cooler operation and increased reliability * 80oC rise temp, 130oC insulation system for harsh, heavy-duty standards * 50/60 Hz Frequency * Meets or exceeds electrical requirements of NEMA, ANSI and IEC E77014 Design Style Certifications and Compliances * Listed: E77014 - UL 506 - CSA C22.2 No. 66 * -IEC 61558-1, IEC 61558-2-2 * RoHS Compliant Related Products * DIN Rail Power Supplies * 63 Series Power Conditioners * Surge Protective Devices Top View Profile Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 193 4 Industrial Control Transformers Selection Tables: International Series Group 5 - 240/415/480 Volt Primary, 120/240 Volt Secondary, 50/60 Hz 230/400/460 Volt Primary, 115/230 Volt Secondary, 50/60 Hz 220/380/440 Volt Primary, 110/220 Volt Secondary, 50/60 Hz Continuous Instantaneous VA VA * Catalog Number Height in (mm) Width in (mm) Depth in (mm) Mtg Width "W" Mtg Depth "D" Slot Size inches (mm) Approx. Ship Weight lbs (kg) 380/400/415 220/230/240 1000 2500 CE1000TH 5.63 (143.0) 6.38 (162.1) 6.00 (152.4) 5.31 (135.0) 4.25 (108.0) .31 x .69 (7.87 x 17.52) 25 (11.36) 1500 4200 CE1500TH 5.63 (143.0) 6.38 (162.1) 6.75 (171.5) 5.31 (135.0) 5.00 (127.0) .31 x .69 (7.87 x 17.52) 32 (14.55) CE2000TH 5.63 (143.0) 6.38 (162.1) 7.75 (196.9) 5.31 (135.0) 6.00 (152.4) .31 x .69 (7.87 x 17.52) 37 (16.82) Slot Size in (mm) Approx. Ship Weight lbs (kg) 2000 6000 H4 X4 440/460/480 H3 X1 X3 X2 X4 H2 120 (480/415/240) 115 (460/400/230) 110 (440/380/220) X2 X3 X1 X3 X2 X4 240 (480/415/240) 230 (460/400/230) 220 (440/380/220) X1 H1 0 0 50/60 Hz * At 50% PF (Power Factor), 95% Nominal Secondary Voltage. Group 6 - 208/240/415/480/600 Volt Primary, 120/240 Volt Secondary, 50/60 Hz 200/230/400/460/575 Volt Primary, 115/230 Volt Secondary, 50/60 Hz - /220/380/440/550 Volt Primary, 110/220 Volt Secondary, 50/60 Hz Continuous Instantaneous VA VA * Catalog Number Height in (mm) Width in (mm) Depth in (mm) Mtg Width "W" in (mm) Mtg Depth "D" in (mm) H6 X4 550/575/600 H5 X1 X3 X2 X4 120 (600/480/415/240/208) 115 (575/460/400/230/200) 110 (550/440/380/220/ - ) 440/460/480 1000 2500 CE1000MH 5.63 (143.0) 6.38 (162.1) 6.00 (152.4) 5.31 (135.0) 4.25 (108.0) .31 x .69 (7.87 x 17.52) 25.0 (11.36) H4 X2 X3 380/400/415 H3 1500 4200 CE1500MH 5.63 (143.0) 6.38 (162.1) 6.75 (171.5) 5.31 (135.0) 5.00 (127.0) .31 x .69 (7.87 x 17.52) 32.0 (14.55) 2000 6000 CE2000MH 5.63 (143.0) 6.38 (162.1) 7.75 (196.9) 5.31 (135.0) 6.00 (152.4) .31 x .69 (7.87 x 17.52) 37.0 (16.82) Approx. Ship Weight lbs (kg) 220/230/240 X1 X3 X2 X4 240 (600/480/415/240/208) 230 (575/460/400/230/200) 220 (550/440/380/220/ - ) X1 H1 0 50/60 Hz 0 * At 50% PF (Power Factor), 95% Nominal Secondary Voltage. Group 7 - 208/240/415/480/600 Volt Primary, 120/ - /24 Volt Secondary, 50/60 Hz 200/230/400/460/575 Volt Primary, 115/24/23 Volt Secondary, 50/60 Hz - /220/380/440/550 Volt Primary, 110/23/- Volt Secondary, 50/60 Hz Continuous Instantaneous VA VA * Catalog Number Height in (mm) Width in (mm) Depth in (mm) Mtg Width "W" in (mm) Mtg Depth "D" in (mm) Slot Size in (mm) CE750MC 5.63 (143.0) 6.38 (162.1) 6.00 (152.4) 5.31 (135.0) 4.25 (108.0) .31 x .69 (7.87 x 17.52) 25 (11.36) CE1000MC 5.63 (143.0) 6.38 (162.1) 6.75 (171.5) 5.31 (135.0) 5.00 (127.0) .31 x .69 (7.87 x 17.52) 32 (14.55) H6 NC X5 H5 440/460/480 750 1000 1875 3000 X6 550/575/600 H4 120 (600/480/415/240/208) 115 (575/460/400/230/200) 110 (550/440/380/220/ - ) 380/400/415 X4 24 (575/460/400/230/200) 23 (550/440/380/220/ - ) H3 220/230/240 H2 X3 24 (600/480/415/240/208) -200/208 1500 4500 CE1500MC 5.63 (143.0) 6.38 (162.1) 7.75 (196.9) 5.31 (135.0) 6.00 (152.4) .31 x .69 (7.87 x 17.52) 37 (16.82) Notes: 24V output 500 VA maximum load. Fuse holders are not available for these voltage configurations. * At 50% PF (Power Factor), 95% Nominal Secondary Voltage. 194 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. X2 X1 H1 0 50/60 Hz 0