Switches & Pilot Devices o30mm - CS Series Switches & Pilot Devices CS Series -- Heavy Duty Cam Switches Key features: * Wide variety of heavy-duty oiltight cam switches * Operators available up to 12 positions * Switches made with a double circuit contact block * Contact blocks rated 600V, 10A Signaling Lights * Ideal for ammeter/voltmeter applications * Built to order -- not available in subcomponents * UL listed and CSA certified * Type 4, 13 CSA Certified File No. LR48366 UL Listed File No. E68961 Rated Thermal Current AC 10A Break Current Resistive DC Inductive Relays & Sockets Contact Ratings 120V/5A 240V/3A 480V/2A 600V/1A Break Current 24V/8A 110V/3A 220V/1A 440V/0.45A Break Current 24V/5A 110V/1.2A 220V/0.45A 440V/0.20A Make Current (A) Rated amperage x 1.1 Electrical Life 500,000 operations minimum (at full rated load) Mechanical Life 5,000,000 (at no load) Timers CS Series Operator Series ACSNO Up to 12 45 Up to 8 60 Up to 6 90 Up to 4 30 Up to 12 45 Up to 8 60 Up to 6 90 Up to 4 30 Up to 12 45 Up to 8 60 Up to 6 90 Up to 4 45 Spring return Only 3 Handle Styles 1 to 10 decks; Up to 20 contacts YB, SB, PB, FB 1 to 10 decks; Up to 20 contacts HB or standard key 1 to 10 decks; Up to 20 contacts YB, SB, PB, FB 1 to 3 decks; Up to 6 contacts YB, SB, PB, FB Circuit Breakers UCSQM 30 Maximum Contacts To Be Mounted Terminal Blocks UCSQO Position Contactors ACSNK Style Cam Angle 1. Do not use spring return (SR) for more than six contacts. 2. Two identical keys come with ACSNK unit. Specify "H" for handle key option. 1705151134 800-262-IDEC (4332) * USA & Canada 773 Switches & Pilot Devices Switches & Pilot Devices o30mm - CS Series Selector Switches (Assembled) Assembled Selector Switches Signaling Lights ACSNO - 3 6 6 - ( ) SB - C3013 Series Contact Arrangement ACSNO = Standard Cam Switch (30mm) ACSNK = Key Cam Switch (30mm) UCSQO = Cam Switch (5 hole mounting) UCSQM = 3 Position Spring Return Cam Switch (5 hole mounting) 1. For standard contact arrangements, use designations on page 642. 2. For custom contact arrangements, omit contact arrangement designation and complete the blank order form on page 777. Relays & Sockets Number of Levels (Decks) 1 through 10 Handle Note: One level contains two independent contacts.* YB = Knob, Small SB = Lever, Small PB = Lever, Large FB = Knob, Large HB = Handle Key (ACSNK only) Blank = Standard Key (ACSNK only) Number of Positions 2 through 12 3 = 30 (12 position max) 4 = 45 (8 position max) 6 = 60 (6 position max) 9 = 90 (4 position max) Spring Return Action Blank: Maintained RO = Spring return from left (3 or 4position, 45 only) OR = Spring return from right (3 or 4 position, 45 only) RR = Return from right and left (3 pos, 45 only) 1. *Contact blocks may contain two independent contacts, (a four position switch with four independent contacts only requires two contact blocks). 2. *Caution: switches with 180 or more of rotation may require separate blocks for each contact due to cam overlapping. 3. Key retainable in every 45 position (45, 90, 180, 225, 270, 315, 360). Circuit Breakers Terminal Blocks Contactors Timers Angle 774 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - CS Series Switches & Pilot Devices Contact Arrangements Standard Arrangements Terminal Numbers 3 4 1 2 1 2 Position Numbers C-1002 C-1014 C-1005 C-1008 3 4 3 4 3 4 3 4 3 4 1 2 1 2 1 2 1 2 1 2 1 C-2001 1 2 C-2002 2 1 C-2006 2 1 C-2004 2 Signaling Lights C-1001 3 C-2008 C-2009 C-2027 8 7 8 7 8 7 8 7 8 7 8 7 8 5 6 5 6 5 6 5 6 5 6 5 6 5 6 3 4 3 4 3 4 3 4 3 4 3 4 1 2 1 2 3 4 1 2 1 2 1 2 1 2 1 1 1 2 2 1 C-3001 C-3002 2 3 1 C-3005 2 3 4 1 C-3013 2 3 4 12 11 12 11 12 11 12 11 12 9 10 9 10 9 10 9 10 9 10 7 8 7 8 7 8 7 8 7 8 5 6 5 6 5 6 3 4 5 6 5 6 3 4 3 4 1 2 3 4 3 4 1 2 1 2 1 2 1 1 2 1 3 2 3 1 C-4001 2 3 4 5 15 16 14 13 14 11 12 11 12 9 10 9 10 7 8 7 8 5 6 5 6 3 4 3 4 1 2 1 C-5001 3 6 2 1 2 1 2 3 4 5 6 7 C-6001 23 24 23 24 18 21 22 21 22 16 19 20 19 20 13 14 17 18 11 12 17 18 15 16 9 10 13 14 15 16 7 8 11 12 13 14 5 6 9 10 11 12 3 4 7 8 9 10 1 2 5 6 7 8 3 4 5 6 1 2 3 4 2 3 4 1 Terminal Blocks 20 1 5 C-6002 15 3 4 8 17 2 3 2 4 19 1 5 Contactors 16 13 2 4 C-4002 15 1 3 Timers 2 2 C-3016 11 1 2 1 Relays & Sockets 7 2 1 2 3 4 5 6 7 8 9 10 11 12 Circuit Breakers 1705151134 800-262-IDEC (4332) * USA & Canada 775 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o30mm - CS Series Contact Arrangements continued Ammeter Switching C-1012 C-4007 CS R S T CT 15 O R S T A 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 E C-4003 C-6003 CS CS Relays & Sockets R S T 15 CT O R S T A 16 R S T 23 O R S T 14 21 22 11 12 19 20 9 10 17 18 7 8 15 16 5 6 13 14 3 4 11 12 1 2 9 10 7 8 5 6 3 4 1 2 E CT A 24 13 Timers E Voltmeter Switching C-2022 C-3008 CS R S T E PT Contactors 3o-4W CS 7 8 5 6 3 1 V R S T 11 PT O RS ST TR 12 9 10 4 7 8 2 5 6 3 4 1 2 C-3009 V C-3007 CS R S T E PT 12 9 10 7 8 5 6 3 4 1 2 V Circuit Breakers Terminal Blocks 3o-4W 11 776 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - CS Series Switches & Pilot Devices Order Form (Custom Contact Arrangement) ( ) Series Handle ACSNO ACSNK UCSQO UCSQM YB = Knob, Small SB = Lever, Small PB = Lever, Large FB = Knob, Large *Number of Decks Specify Qty = 1, 2, 3, 4, 5, 6, 7, 8, 9, or 10 Number of Positions ACSNO ACSNK* UCSQO Positions 30 only 9, 10, 11, 12 30 or 45 only 7 or 8 30, 45 or 60 5 or 6 Angle 45 only 3 only * ACSNK keys only remove at 45. HB = Handle Key (option) Blank = Standard Key Blank = Maintained RO = Spring return from left (3 or 4 position, 45) OR = Spring return from right (3 or 4 position, 45) RR = Return from right and left (3 position, 45) For handle styles, see page 778. Relays & Sockets 3 = 30 4 = 45 6 = 60 9 = 90 30, 45, 60, 90 2, 3, or 4 UCSQM ACSNK: Spring Return Angle Signaling Lights *Note: One Deck can drive two independent contacts. Unit ACSNO, UCSQO, UCSQM: UCSQM is available in spring-return version only. Contact Arrangement Table Position Terminal Numbers 1 and 2 3 and 4 5 and 6 7 and 8 9 and 10 11 and 12 13 and 14 15 and 16 17 and 18 19 and 20 21 and 22 23 and 24 25 and 26 27 and 28 29 and 30 31 and 32 33 and 34 35 and 36 37 and 38 39 and 40 Cams Deck 1 Deck 3 Deck 4 Deck 5 Deck 6 Deck 8 Deck 9 Deck 10 3 4 5 6 7 8 9 10 11 12 Contactors Deck 7 2 Timers Deck 2 1 Terminal Blocks To specify non-standard arrangements (designation not on preceding pages), fill in this table using the following symbols. X = Closed contact (break before make) O = Open contact X X = Overlapping contact (remain on when switch is moved between two positions) Specifying Nameplate (Optional) 30 11 66 55 1705151134 44 22 66 33 55 11 44 22 88 7733 44 66 90 11 22 44 33 11 44 11 4422 33 22 33 55 22 33 If no engraving information is provided, a blank nameplate will be supplied. Position 1________________________________ 1________________________________ 2________________________________ 2________________________________ 3________________________________ 3________________________________ 4________________________________ 4________________________________ 5________________________________ 5________________________________ 6________________________________ 6 800-262-IDEC (4332) * USA & Canada Circuit Breakers 60 11 12 12 11 22 12 12 11 22 45 88 11 11 33 33 11 11 10 10 77 44 10 1044 99 55 99 55 6 88 7 66 6 55 88 7 66 7 7 Specifying Legends 777 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o30mm - CS Series Accessories -- CS Series Replacement Handles Part Number CSH-YB CSH-SB CSH-PB CSH-FB CSH-H2B Dimensions 0.79"D x 1.61"H 0.79"D x 1.97"H 1.58"D x 1.97"H 1.58"D x O 1.97" 0.95"D x 2.28"H Timers Relays & Sockets Applicable Models ACSNO, UCSQO, UCSQM ACSNK Replacement Nameplates Size & Shape q 2.52" (64mm) Black Aluminum Part Number Applicable Models CQ CQM CQN UCSQO UCSQM ACSNO, ACSNK 1. Extra cost for engraving, 3/16" min. letter height, Legends maximum ten characters. 2. Blank nameplates are supplied with all cam switches (they need not be ordered separately). Contactors Wiring Clips Part Number Contact Block Jumpers CJ-1 Between decks Terminal Blocks CJ-2 Same deck Replacement Keys Circuit Breakers Part Number Description K301 Pair of keys (#301) 778 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - CS Series Switches & Pilot Devices Dimensions/Terminal Arrangements/Mounting Holes Panel Thickness 0.8 to 6 2 Terminal Arrangement 52 50 (S2 Handle) M3.5 Terminal Screw 52 ACSNO 12 9 47 12N+9 47 30.7 * ACSNK Signaling Lights * Spring Return: 44 Maintained: 42 N: Number of Contact Blocks Panel Thickness 0.8 to 6 M3.5 Terminal Screw 52 12 9 35 * 47 * Spring Return: 44 Maintained: 42 N: Number of Contact Blocks Mounting Holes Panel Thickness 7.0 max. 2 33 +0.5 0 9 12 12N+9 * 48 25 7 Panel Thickness 7.0 max. UCSQO UCSQM 50 (P2 Handle) 9 12 12N+9 31 7 43 Contactors M3.5 Terminal Screw 2 4-M4 Screw 64 46.4 52 UCSQM o30.5 +0.5 0 (ACSNO/ACSNK) 70 * Spring Return: 31 Maintained: 29 N: Number of Contact Blocks Timers M3.5 Terminal Screw R0.8 max. +0.2 4.8 0 4-M4 Screw 64 41 (Y2 Handle) 46.4 52 UCSQO Relays & Sockets 12N+9 47 4-o4.5 48 3 o1 70 N: Number of Contact Blocks 48 2 30 52 47 48 Terminal Blocks Circuit Breakers 1705151134 800-262-IDEC (4332) * USA & Canada 779