4 Power Supplies Silver Line Series - Single & Multi-Output Linears Specifications Parameter Condition Limit Input 100/120/220/230/240 VAC Selectable Input Voltage Input Frequency 47-63 Hz Output Line Regulation for 10% change Load Regulation for 50% change The Silver Line series follows the industry accepted footprint for open frame, linear power supplies. Sola improves on this design by offering standard screw terminal connections and optional covers for safety considerations. Features * * * * * * * * * * Easy-to-install screw terminal connections Cover options Industry standard footprint Universal input and approvals (115/230 VAC) Low noise, extremely quiet DC output. For noise sensitive or analog circuitry. Fast transient response. Ideal for test applications. Built-in OVP on 5 V models and optional on 12, 15 and 24 V models Automatic resetting overload protection Short circuit protected Two year warranty Applications * * * * * * * * 110 Industrial control circuits and components Instrumentation Drives CNC machinery Equipment for food industry Microprocessor circuits Analog circuits Noise sensitive circuitry and sensors LVD DC Output Adjustment Range 5% Minimum All 5-Volt outputs include build-in OVP as standard (setting is 6.2 V 0.4 V) OVP is optionally available on other types Overvoltage Protection Transient Response Time at 50% Load Changes Overload Protection Remote Sensing 0.05% 3.0 mV maximum Peak-to-Peak Ripple UL 60950 E137632 0.05% 50 msec. Automatic current limit foldback Available to compensate for output voltage drop on selected models. 0.5 VDC General Operating Temperature Range Derate to 40% at +70C 0 to +50C Storage Temperature Range -25C to +85C Temperature Coefficient (Typical) 0.01% 0C Stability After warm-up .5% Vibration Method 514 Per MIL-STD-810C Shock Method 516 Per MIL-STD-810C Linear power supplies have inherently low conducted and radiate noise levels For most system applications they will meet requirements of FCC Class B and VDE 0871 for class B EMI/RFI Cover Option Cooling Derate power by an additional 15% Forced air. 20 CFM required for full rating Derate 30% without cooling Specifications are typical. Load Regulation on outputs without Remote Sense, .1% typical. Visit our website at www.solaheviduty.com or contact Technical Services at (800) 377-4384 with any questions. 4 Power Supplies SL Series Selection Table Catalog Number Dimensions - inches (mm) Output 1 Output 2 Output 3 Case SLS-05-030-1T 5 V @ 3 A*# - - A SLS-05-060-1T 5 V @ 6 A*# - - B1 SLS-05-090-1T 5 V @ 9 A*# - - C SLS-05-120-1T 5 V @ 12 A*# - - I2 SLS-12-017T1 12 V @ 1.7 A# or 15 V @ 1.5 A - - A SLS-12-034T 12 V @ 3.4 A# - - B1 SLS-12-051T 12 V @ 5.1 A# - - C SLS-12-068T 12 V @ 6.8 A# - - I2 SLS-15-045T 15 V @ 4.5 A# - - C SLS-15-060T 15 V @ 6 A# - - I2 SLS-24-012T 24 V @ 1.2 A# - - A SLS-24-024T 24 V @ 2.4 A# - - B2 SLS-24-036T 24 V @ 3.6 A# - - C SLS-24-048T 24 V @ 4.8 A# - - I2 SLS-24-072T 24 V @ 7.2 A# - - K SLS-24-120T 24 V @ 12.0 A# - - L SLD-12-1010-12T1 12 V @ 1 A or 15 V @ .8 A -12 V @ 1 A or -15 V @ .8 - H1 SLD-12-1818-12T1 12 V @ 1.8 A or 15 V @ 1.5 A -12 V @ 1.8 A or -15 V @ 1.5 A - D SLD-12-3434-12T 12 V @ 3.4 A# -12 V @ 3.4 A# - I3 SLD-15-3030-15T 15 V @ 3 A# -15 V @ 3 A# - I3 SLD-12-6034-05T 5 V @ 6 A*# 12 V @ 3.4 A# - I1 SLD-12-3015-05T 5 V @ 3 A*# 12 V@ 1.5 A - C1 SLT12-20404-12T1 5 V @ 2 A*# 12 V @ .4 A or 15 V @ .4 A -12 V @ .4 A or -15 V @ .4 A H2 SLT12-31010-12T1 5 V @ 3 A*# 12 V @ 1 A# or 15 V @ .8 A -12 V @ 1 A# or -15 V @ .8 A F SLT12-61010-12T1 5V @ 6 A*# 12 V @ 1 A or 15 V @ 1 A -12 V @ 1 A or -15 V @ 1 A I4 SLT12-61818-12T1 5V @ 6A*# 12 V @1.8 A or 15 V @1.5 A -12 V @ 1.8 A or -15 V @ 1.5 A G2 SLT24-30530-05T 5V @ 3A* -5 V @ .5 A* 24 V @ 3 A G1 Over Voltage Protector (OVP) SLO-12-000-1 SLO-12-000-TB 6.2 V to 34 V Adjustable @ 8 A 6.2 V to 34 V Adjustable @ 8 A For Cases B through K For Case A or Cases B through K (when used with a cover) J1 J2 Case A Case B Cover Options Catalog Number Description Catalog Number Description SLCASA-CVR Cover for Case A SLCASG-CVR Cover for Cases G1 and G2 SLCASB-CVR Cover for Case B SLCASH-CVR Cover for Cases H1 and H2 SLCASC-CVR Cover for Case C SLCASI-CVR Cover for Cases I1, I2, I3 and I4 SLCASC1-CVR Cover for Case C1 SLCASK-CVR Cover for Case K SLCASD-CVR Cover for Case D SLCASL-CVR Cover for Case L SLCASF-CVR Cover for Case F Note: Covers are sold separately. When used, derate the power supply by 15% of its rated value. Notes: * With Built-In OVP # With Remote Sense (R.S.) 1 12/15 Volt models are factory set for 12 Volt operation. 15 Volt operation is field adjustable. Visit our website at www.solaheviduty.com or Contact Technical Services at (800) 377-4384 with any questions. 111 4 Power Supplies Silver Line Dimensions (inches/mm) Case F Cases C and C1 Cases G1 and G2 Case D AC Input Jumper Connections AC Input Jumper Connections For use at: 100 VAC 120 VAC 220 VAC 230/240 VAC Connect: 1-3, 2-4 1-3, 2-4 2-3 2-3 Apply AC: 1&5 1&4 1&5 1&4 Cases H1 and H2 112 Visit our website at www.solaheviduty.com or contact Technical Services at (800) 377-4384 with any questions. 4 Power Supplies Silver Line Dimensions (inches/mm) Case J1 Case J2 Cases I1, I2, I3 and I4 Case K Notes: All dimensions in inches (mm). Dimensions may change and should not be used for construction purposes. Be sure to specify the complete part number when ordering. Orders may be placed with your local Sola/Hevi-Duty distributor. Case L Visit our website at www.solaheviduty.com or Contact Technical Services at (800) 377-4384 with any questions. 113 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Sola/Hevi-Duty: SLCASI-CVR SLCASC-CVR SLCASB-CVR SLCASA-CVR SLD-12-6034-05T SLCASL-CVR SLCASLCVR