1
ELECTRICAL SPECIFICATIONS
Input
Input Voltage (VAC)
120V-277V (+/- 10%)
Frequency Range (Hz)
50 60 Hz (+/- 10%)
120V
277V
Input Current (A)
0.85
0.37
THD @ Full load
< 20%
< 20%
Power Factor @ Full load
>0.9
>0.9
Efficiency @ Full load
85%
85%
Inrush Current (Apk)
30
68
Output
Output Current (mA)
1.252.0A (1mA step)
(Programmable)
Output Voltage (VDC)
30-55VDC
(Power limited)
Output Ripple Current
<25% of DC value
Max. Output power (W)
85W Max (Regulated)
LED Power-up time
< 1 sec
Load Regulation
<5%
Line Regulation
<5%
Over voltage protection
Yes, non- latching
Over load protection
Yes, current fold back
@87W
Output short-circuit
protection
Yes, latching
LEDSet2 (LT2)
LEDSet2
Available
LED thermal protection (NTC)
NTC value active range
25kΩ
Output level minimum
User defined
GENERAL INFORMATION
79470
Constant Current,
Class2, Class TL
85W (Max.)
51645, 51647 & 51648
Download
Output current
Dimming level
LED thermal protection
Constant Lumen output
End of life indicator
ELECTRICAL SPECIFICATIONS
Dimming
Dimming Control
0 10V (Isolated)
Dimming Range
10-100%
Dimming Type
Analog
Dimming Input Isolation
2.5KV
Source/Sink Current
<0.8mA
ENVIRONMENTAL SPECIFICATIONS
Ambient Operating
Temperature
-40 ºC to 40 ºC
Case Temperature (Tc)
80ºC*
90°C (max)
Max. Storage Temp.
70ºC
Max. Relative Humidity (%)
85% non condensing
Transient Protection
NEMA SSL1 - 2010
Non-Roadway 2.5KV
UL Environmental Rating
Dry & Damp, RoHS
UL File number
E320395 // Class TL
EMI Compliance
FCC Part 15 Class A
Sound Rating
Class A
*- Warranty applicable only at 80ºC
OPTOTRONIC® LED Power Supply
OTi 85/120-277/2A0 DIMLT2 L- Technical Specifications
www.osramamericas.com/OPTOTRONIC
2
WIRING DIAGRAM
Note 1: Default current programmed on the Driver is 2A.
Note 2: Maximum suggested remote mounting distance is 16 feet. For additional information on further distances and EMI
compliance reference OPTOTRONIC Technical Guide LED258
MECHANICAL DIAGRAM
MECHANICAL SPECIFICATIONS
Length
14.2” (360mm)
Width
1.2” (30mm)
Height
1.0” (25.4mm)
Mounting Distance
13.77” (350mm)
3
OPERATING RANGE
DIMMING RANGE
25
35
45
55
1200 1400 1600 1800 2000
Output Voltage [V]
Output Current [mA]
2A model
0
20
40
60
80
100
0 1 2 3 4 5 6 7 8 9 10
% of Output Current
Dim Voltage [V]
10% Dimming
4
THD VS INPUT VOLTAGE (FULL LOAD)
POWER FACTOR VS INPUT VOLTAGE (FULL LOAD)
1
2
3
4
5
6
100 150 200 250 300 350
THD [%]
Input Voltage [VAC]
0.97
0.975
0.98
0.985
0.99
0.995
1
100 150 200 250 300 350
Power Factor
Input Voltage [VAC]
5
EFFICIENCY VS OUTPUT VOLTAGE
83
84
85
86
30 35 40 45 50 55
Efficiency (%)
Output Voltage (V)
Efficiency @ 120V
2000mA
1800mA
1550mA
80
82
84
86
88
30 35 40 45 50 55
Eficiency [%]
Output Voltage [V]
Efficicency @ 277V
2000mA
1800mA
1550mA
6
POWER FACTOR VS OUTPUT VOLTAGE
0.900
0.910
0.920
0.930
0.940
0.950
0.960
0.970
0.980
0.990
1.000
30 35 40 45 50 55
Power Factor
Output Voltage (V)
Power Factor @ 120V
2000mA
1800mA
1550mA
0.900
0.910
0.920
0.930
0.940
0.950
0.960
0.970
0.980
0.990
1.000
30 35 40 45 50 55
Power factor
Output Voltage [V]
Power factor @ 277V
2000mA
1800mA
1550mA
7
THD VS OUTPUT VOLTAGE
0.00
2.00
4.00
6.00
8.00
10.00
30 35 40 45 50 55
THD (%)
Output Voltage (V)
THD @ 120V
2000mA
1800mA
1550mA
0.00
2.00
4.00
6.00
8.00
10.00
30 35 40 45 50 55
THD [%]
Output Voltage [V]
THD @ 277V
2000mA
1800mA
1550mA
8
LED THERMAL PROTECTION (NTC) CHARACTERISTIC
The LED thermal protection feature of the OTi85W helps reduce the temperature of the LED module by reducing
the output current in case of abnormal temperature conditions. To use this feature a third party NTC thermistor
should be connected to the LED power supply as shown in the wiring diagram below.
In the end application, care must be taken to place the NTC thermistor close to the hottest spot on the LED module.
If LED thermal protection is not required the NTC port on the LED power supply connector can be left open.
Vishay, EPCOS, Murata, Panasonic are some of the manufacturers of NTC thermistor. EPCOS part number for
reference only B57164K153J (15kΩ @ 25°C). Murata part number for reference only - NCP03XH223J05RL (22kΩ
@ 25°C)
Note 4: Graphs for reference. The derating limits can be programmed using the OT Linear Handheld Programmer
Derating start = 6.3kΩ; Derating end = 4.3kΩ; Min output level = 10%
CONSTANT LUMEN MAINTENANCE
The Constant Lumen Maintenance feature of the OTi85W helps to maintain the required lumen output of the fixture
at a constant level throughout its lifetime. In general LED’s lumen output will depreciate over time and in order to
maintain sufficient light level towards the end of lifetime, the LED’s are driven at high current initially and will result
in more energy consumption. The constant lumen maintenance will give the flexibility to drive the LEDs at optimal
driving current throughout its lifetime. This helps in energy savings, constant light output and enhanced reliability of
the system.
Note 5: A detailed step-by-step instructions are outlined in the ‘OT Programmer User Manual
0
20
40
60
80
100
4 4.5 5 5.5 6 6.5
% Of Output Current
RNTC in kΩ
9
END OF LIFE INDICATOR
The End-of-Life indicator feature helps the end user to receive a signal from the fixture indicating that it has
reached its programmed life-time. After the LED driver reach the programmed life-time, whenever it is turned ON, it
stays at ‘Dim’ level (10%) for 10 minutes and reaches its appropriate level.
INRUSH CHARACTERISTICS
Vin
(V)
Ipeak
(A)
T (@ 50% of
Ipeak)
120
30
50uS
277
68
30uS
LIFE TIME VS CASE TEMPERATURE
DIMMER COMPATIBILITY
Manufacturer
Part no
Encelium EMS
EN-LCM-1R10V-GB2-BK
EN-LCM-1R10V-GB2-BK/DR
EN-ALC-1R10V-GB2-BK
EN-ALC-1R10V-GB2-BK-DR
OSRAM
45561 - LC-SL3W-TVWBX/UNV
Leviton
IP710-DLX
Lutron
DVTV-XX
Wattstopper
ADF-120277
Synergy lighting Controls
ISD BC
Note: The absence of a dimmer from this chart does not necessarily imply incompatibility. Please reference the
dimmer manufacturer’s instructions for installation.
20
40
60
80
100
120
30 35 40 45 50 55 60 65 70 75 80 85 90
Lifetime (KHrs)
Temperature C)
Driver-Lifetime Vs Case Temperature
10
UL CONDITIONS OF ACCEPTABILITY (E320395)
The LED driver was evaluated using an electronic LED load resulting in an output rated current and rated
power as indicated in the electrical ratings.
The unit employs a Class B isolation transformer (L300) on the main PWB. The need to repeat the temperature
test shall be determined in end-use product. TC point case temperatures in the end-use shall not exceed 90°C.
The unit was tested on a 20A branch circuit. If used on a branch circuit greater than this, additional testing may
be necessary.
The PWB spacing’s for use in damp locations have been evaluated to CSA 250.13/UL 8750, the unit is partially
potted on the top of the PCB and fully potted on the bottom of the PCB. Areas that are potted meet spacing
requirements are out of Table 5/7.4 parts potted or subsequently coated. Other areas meet applicable
requirements in table 5/7.4.
The leakage current test was conducted between the ground terminal, exposed conductive surface and the
grounded pole of the supply circuit.
The products are intended for use in Dry and Damp locations. The use in other environmental locations shall be
considered in the end product.
Leads to be determined in the end product.
These test conditions are for TL rating: This model was tested in a 40°C ambient. For Tref. values see Table
Below. Determination to repeat the temperature test shall be made in end-use product. During the normal
temperature test of the end product, the temperature at any point on the case is to be monitored and shall not
exceed 90°C. When provided the tc in a circle can be a considered a reference hot spot on the case:
Product
Tref Max
Tref measured @ 40C
OTi 85/120-277/2A0 DIMLT2 L
90°C
89°C
WARRANTY
OPTOTRONIC® products are covered by our LED Module, OPTOTRONIC Power Supply or Control Warranty. For
additional details, refer to the latest version of the warranty (LED395) available at www.osram-americas.com/optotronic.
OSRAM and OPTOTRONIC are registered trademarks of OSRAM GmbH..
Specifications subject to change without notice