1
G3VM-101LR
MOS FET Relays
World’s Smallest* SSOP Package
MOS FET Relays with High Load Voltage
of 100 V.
Leakage current of 200 pA max. when output relay is open.
*As of March 2011 Survey by OMRON
Application Examples Terminal Arrangement/Internal
Connections
List of Models
Note: Ask your OMRON representative for orders under 1500 pcs or 500 pcs. We can supply products with the tape already cut.
Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them.
Refer to common precautions.
*The AC peak and DC value are given for the load voltage.
Absolute Maximum Ratings (Ta = 25 °C)
Electrical Characteristics (Ta = 25 °C)
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
Semiconductor test equipment
Test & Measurement equipment
Communication equipment
Data loggers OMRON mark
Model name
LOT.No.
416
612
Note: The actual product is marked differently from the image shown here.
Package type Contact form Terminals Load voltage
(peak value) *Model
Minimum package quantity
Number per tape and reel
SSOP4 1a
(SPST-NO) Surface-mounting Terminals 100 V
G3VM-101LR -
G3VM-101LR (TR05) 500
G3VM-101LR (TR) 1,500
Item Symbol Rating Unit Measurement conditions
Input
LED forward current IF50 mA
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
LED forward current reduction rate
IF/°C0.5 mA/°C Ta 25 °C
LED reverse voltage VR5 V
Connection temperature
TJ125 °C
Output
Load voltage (AC peak/DC)
VOFF 100 V
Continuous load current (AC peak/DC)
IO80 mA
ON current reduction rate
IO/°C0.8 mA/°C Ta 25 °C
Connection temperature
TJ125 °C
Dielectric strength between
I/O (See note 1.) VI-O 1500 Vrms AC for 1 min
Ambient operating temperature
Ta 20 to +85 °C With no icing or condensation
Ambient storage temperature
Tstg 40 to +125 °C With no icing or condensation
Soldering temperature - 260 °C10 s
Item Symbol
Minimum
Typical
Maximum
Unit Measurement conditions
Input
LED forward voltage VF1.0 1.15 1.3 V IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times
Reverse current IR- - 10 µA VR = 5 V
Capacity between terminals
CT- 15 - pF V = 0, f = 1 MHz
Trigger LED forward current
IFT -15mA IO = 80 mA
Output
Maximum resistance with output ON
RON -814
I
F
= 10 mA, I
O
= 80 mA, t = 10 ms
Current leakage when the relay is open
ILEAK --200pA VOFF = 80 V
Capacity between terminals
COFF - 6 8 pF V = 0, f = 100 MHz, t < 1 s
Capacity between I/O terminals
CI-O - 0.6 - pF f = 1 MHz, VS = 0 V
Insulation resistance between I/O terminals
RI-O 1000 - - M
V
I-O
= 500 VDC, R
O
H
60 %
Turn-ON time tON - 0.1 0.3 ms
IF = 5 mA, RL = 200 ,
VDD = 20 V (See note 2.)
Turn-OFF time tOFF - 0.1 0.3 ms
VOUT
IF
tON tOFF
10% 90%
IF1
2
4
3
RLVDD
VOUT
2
G3VM-101LR MOS FET Relays
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Engineering Data
Safety Precautions
Refer to "Common Precautions" for all G3VM models.
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD --80V
Operating LED forward current
IF10 - 30 mA
Continuous load current (AC peak/DC)
IO--80mA
Ambient operating temperature
Ta 25 - 60 °C
LED forward current vs. Ambient temperature
Continuous load current vs. Ambient temperature
LED forward current vs. LED forward voltage
Continuous load current vs. On-state voltage
On-state resistance vs. Ambient temperature
Trigger LED forward current vs. Ambient temperature
Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature
Current leakage vs. Load voltage
Output terminal capacitance vs. Load voltage
I
F
- Ta
Ambient temperature Ta (°C)
LED forward current I
F
(mA)
-20 0 20 40 60 80 100 120
0
20
40
60
80
100
I
O
- Ta
Ambient temperature Ta (°C)
Continuous load current I
O
(mA)
-20 0 20 40 60 80 100 120
0
20
40
60
80
100
120
I
F
- V
F
LED forward voltage V
F
(V)
LED forward current I
F
(mA)
Ta = 25 °C
0.6 0.8 1 1.2 1.4 1.6 1.8
0.1
1
10
100
I
O
- V
ON
On-state voltage V
ON
(V)
Continuous load current I
O
(mA)
-1 -0.5 0 0.5 1
-100
-80
-60
-40
-20
0
20
40
60
80
100
Ta = 25 °C
I
F
= 10 mA
R
ON
- Ta
Ambient temperature Ta (°C)
On-state resistance R
ON
()
-20 0 20 40 60 80 100
0
10
20
30
0
10
20
30
I
O
= 80 mA
I
F
= 10 mA, t < 1 s
I
FT
- Ta
Ambient temperature Ta (°C)
Trigger LED forward current I
FT
(mA)
-20 0 20 40 60 80 100
0
1
2
3
4
5
0
1
2
3
4
5
I
O
= 80 mA
t < 1 s
t
ON
, t
OFF
- I
F
LED forward current I
F
(mA)
Turn ON, Turn OFF time t
ON
, t
OFF
(µs)
550
330110100
3
5
100
300
5000
30
50
500
3000
1
10
1000
Ta = 25 °C
V
DD
= 20 V
R
L
= 200
t
ON
t
OFF
t
ON
, t
OFF
- Ta
Ambient temperature Ta (°C)
Turn ON, Turn OFF time t
ON
, t
OFF
(µs)
-20 0 20 40 60 80 100
30
3
100
300
3000
5000
5
50
500
1
10
1000
V
DD
= 20 V
R
L
= 200
I
F
= 5 mA
t
ON
t
OFF
I
LEAK
- V
OFF
Load voltage (V)
Current leakage I
LEAK
(pA)
02040 60 80 100
Ta = 25 °C
0
20
40
60
80
100
COFF - VOFF
Load voltage (V)
Output terminal capacitance COFF/COFF (pF)
Ta = 25 °C
010203040
0
2
4
6
8
10
Appearance/Dimensions SSOP4 type
Appearance
Dimensions (Unit: mm)
Note: The actual product is marked differently from the image shown here.
Actual Mounting Pad
Dimensions
(Recommended Value, TOP VIEW)
SSOP (Shrink Small Outline Package)
SSOP (Shrink Small Outline Package)
SSOP4
Note: The actual product is marked differently from the image shown here.
416
612
OMRON mark
Model name
LOT.No.
612
416
1.9
1.4 dia.
4.2
2.04
1.27
0.15 1.8
3.65
0.2
(0.46)
3.8
(0.3)
Unless otherwise specified, the
dimensional tolerance is ± 0.1 mm.
Surface-mounting Terminals
Weight: 0.03 g
3.73
0.95
0.8
1.27
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Cat. No. K218-E1-01
0412(0412)(O)
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb