2
CC1R5-E Specifications
MODEL
ITEMS/UNITS
CC1R5-0503Sx-E CC1R5-0505Sx-E
CC1R5-0512Sx-E CC1R5-0512Dx-E
Input
Nominal Voltage V DC5.0
Voltage Range V DC4.5-9.0
Efficiency (typ) (*1) 71 77 80 79
Current (typ) (*1) A 0.372 0.390 0.375 0.380
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature–40C to +50C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) 35
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Temperature -40 to +85
Storage Temperature -40 to +85
Operating Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25C.
(*2) The maximum output power value is between -40C and +50C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC1R5-1203Sx-E CC1R5-1205Sx-E
CC1R5-1212Sx-E CC1R5-1212Dx-E
Input
Nominal Voltage V DC12
Voltage Range V DC9.0-18
Efficiency (typ) (*1) 73 78 82 81
Current (typ) (*1) A 0.151 0.160 0.152 0.154
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature–40C to +50C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) 35
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4 - 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Temperature -40 to +85
Storage Temperature -40 to +85
Operating Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25C.
(*2) The maximum output power value is between -40C and +50C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC1R5-E