CC-E Insulation type DC-DC converter ks ph DENAN F A Features Built to meet UL60950-1/ CSA C22.2 No.60950-1 F A Mounting area halved compared to existing products Nonuse of tantalum capacitor or aluminum electro- pf-a lytic capacitor F products A Symbol for number of outputs S: Single output, D: Dual outputs Nominal output voltage 03: 3.3V, 05: 5V, 12: 12V High accuracy of 3% in output voltage (10W of Nominal input voltage lower single output) hk-a 05: 5V, 12: 12V, 24: 24V, 48: 48V 5-side metal-shielded low noise design Maximum output power Lightweight design with no resin filled up 1R5: 1.5W, 3: 3W, 6:6W 10: 10W, 15: 15W, 25: 25W Supports DIP insertion,SMD mounting and SIP verti- Representing series name by cal insertion (3W products) hws combination with "-E"at the end Approved by UL60950-1, CSA C22.2 No.60950-1 Applications F Conformity to RoHS Directive (C-UL), and EN60950-1 (NEMKO) A This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retar- dants, PBB and PBDE, have not been used, except for exempted applications. Product Line up alpha Output Input power voltage 5V dlp 1.5W DIP type SMD type F A SIP type Output current DIP type SMD type Model name (output voltage: 12V/15V) SIP type Output current DIP type SMD type Model name (output voltage: 12V/15V) SIP type Output current DIP type SMD type SIP type 0.3A CC1R5-0505SF-E CC1R5-0505SR-E - 0.125A (0.1A) CC1R5-0512SF-E CC1R5-0512SR-E - 0.06A (0.05A) CC1R5-0512DF-E CC1R5-0512DR-E - 12V 0.4A CC1R5-1203SF-E CC1R5-1203SR-E - 0.3A CC1R5-1205SF-E CC1R5-1205SR-E - 0.125A (0.1A) CC1R5-1212SF-E CC1R5-1212SR-E - 0.06A (0.05A) CC1R5-1212DF-E CC1R5-1212DR-E - 24V 0.4A CC1R5-2403SF-E CC1R5-2403SR-E - 0.3A CC1R5-2405SF-E CC1R5-2405SR-E - 0.125A (0.1A) CC1R5-2412SF-E CC1R5-2412SR-E - 0.06A (0.05A) CC1R5-2412DF-E CC1R5-2412DR-E - 48V 0.4A CC1R5-4803SF-E CC1R5-4803SR-E -F 0.3A CC1R5-4805SF-E CC1R5-4805SR-E - 0.125A (0.1A) CC1R5-4812SF-E CC1R5-4812SR-E - 0.06A (0.05A) CC1R5-4812DF-E CC1R5-4812DR-E - A 0.8A CC3-0503SF-E CC3-0503SR-E CC3-0503SS-E 0.6A CC3-0505SF-E CC3-0505SR-E CC3-0505SS-E 0.25A (0.2A) CC3-0512SF-E CC3-0512SR-E CC3-0512SS-E 0.125A (0.1A) CC3-0512DF-E CC3-0512DR-E CC3-0512DS-E 12V 0.8A CC3-1203SF-E CC3-1203SR-E CC3-1203SS-E 0.6A CC3-1205SF-E CC3-1205SR-E CC3-1205SS-E 0.25A (0.2A) CC3-1212SF-E CC3-1212SR-E CC3-1212SS-E 0.125A (0.1A) CC3-1212DF-E CC3-1212DR-E CC3-1212DS-E 24V 0.8A CC3-2403SF-E CC3-2403SR-E CC3-2403SS-E 0.6A CC3-2405SF-E CC3-2405SR-E CC3-2405SS-E 0.25A (0.2A) CC3-2412SF-E CC3-2412SR-E CC3-2412SS-E 0.125A (0.1A) CC3-2412DF-E CC3-2412DR-E CC3-2412DS-E 48V 0.8A CC3-4803SF-E CC3-4803SR-E CC3-4803SS-E 0.6A CC3-4805SF-E CC3-4805SR-E CC3-4805SS-E 0.25A (0.2A) CC3-4812SF-E CC3-4812SR-E CC3-4812SS-E 0.125A (0.1A) CC3-4812DF-E CC3-4812DR-E CC3-4812DS-E CC6-0505SF-E CC6-0505SR-E - 0.5A (0.4A) CC6-0512SF-E CC6-0512SR-E - 0.25A (0.2A) CC6-0512DF-E CC6-0512DR-E - CC6-1205SF-E CC6-1205SR-E - 0.5A (0.4A) CC6-1212SF-E CC6-1212SR-E - 0.25A (0.2A) CC6-1212DF-E CC6-1212DR-E - 5V 6W Model name (output voltage: 5V) - 5V 3W Output current Model name (output voltage: 3.3V) 0.4A CC1R5-0503SF-E CC1R5-0503SR-E fps warranty R: Horizontally-mounted SMD type FS Vertically-mounted SIP type 5 Low Voltage Directive Electrical Appliance and Material Safety Law (Input Voltage 100VAC) Shape F: Horizontally-mounted DIP type Remote On/Off function incorporated in all series of EN60950-1 Low Voltage Directive Electrical UL60950-1/ Appliance CSA C22.2 No.60950-1 and Material Safety Law (Input Voltage 100VAC) Model-naming method CC 3 - 05 05 S F -E EN60950-1 Y E A R DENAN S Built to meet 1.2A CC6-0503SF-E CC6-0503SR-E 12V 1.2A CC6-1203SF-E CC6-1203SR-E -F - A 1A 1.2A 24V 1.2A CC6-2403SF-E CC6-2403SR-E - 1.2A CC6-2405SF-E CC6-2405SR-E - 0.5A (0.4A) CC6-2412SF-E CC6-2412SR-E - 0.25A (0.2A) CC6-2412DF-E CC6-2412DR-E - 48V 1.2A CC6-4803SF-E CC6-4803SR-E - 1.2A CC6-4805SF-E CC6-4805SR-E - 0.5A (0.4A) CC6-4812SF-E CC6-4812SR-E - 0.25A (0.2A) CC6-4812DF-E CC6-4812DR-E - 5V 2.5A CC10-0503SF-E CC10-0503SR-E - 2A CC10-0505SF-E CC10-0505SR-E - 0.8A (0.64A) CC10-0512SF-E CC10-0512SR-E - 0.4A (0.32A) CC10-0512DF-E CC10-0512DR-E - 12V 2.5A CC10-1203SF-E CC10-1203SR-E - 2A CC10-1205SF-E CC10-1205SR-E - 1A (0.8A) CC10-1212SF-E CC10-1212SR-E - 0.45A (0.36A) CC10-1212DF-E CC10-1212DR-E - 24V 2.5A CC10-2403SF-E CC10-2403SR-E - 2A CC10-2405SF-E CC10-2405SR-E - 1A (0.8A) CC10-2412SF-E CC10-2412SR-E - 0.45A (0.36A) CC10-2412DF-E CC10-2412DR-E - 48V 2.5A CC10-4803SF-E CC10-4803SR-E - 2A CC10-4805SF-E CC10-4805SR-E - 1A (0.8A) CC10-4812SF-E CC10-4812SR-E - 0.45A (0.36A) CC10-4812DF-E CC10-4812DR-E - 15W 24V 4.5A CC15-2403SF-E CC15-2403SR-E - 3A CC15-2405SF-E CC15-2405SR-E - - - - - - - - - 25W 24V 7.5A CC25-2403SF-E CC25-2403SR-E - 5A CC25-2405SF-E CC25-2405SR-E - - - - - - - - - 10W All specifications are subject to change without notice. 001-01/20080421/etl_cc_e CC1R5-E CC1R5-E Specifications MODEL CC1R5-0503Sx-E CC1R5-0505Sx-E CC1R5-0512Sx-E CC1R5-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) 71 77 80 79 Current (typ) (*1) A 0.372 0.390 0.375 0.380 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature-40 C to +50 C) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC1R5-1203Sx-E CC1R5-1205Sx-E CC1R5-1212Sx-E CC1R5-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature-40 C to +50 C) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4 - 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC1R5-E MODEL CC1R5-2403Sx-E CC1R5-2405Sx-E CC1R5-2412Sx-E CC1R5-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 72 77 81 79 Current (typ) (*1) A 0.076 0.081 0.077 0.079 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature-40 C to +50 C) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC1R5-4803Sx-E CC1R5-4805Sx-E CC1R5-4812Sx-E CC1R5-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) 70 76 80 79 Current (typ) (*1) A 0.039 0.041 0.039 0.040 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature-40 C to +50 C) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC1R5-E Outline Drawing 16.60.2 Recommended measurements for mounting board 14.605 2.92 8.5max. 4.0 Shape/Dimensions 5 7-0.3x0.6 6 7 a 1 b 0.5 2-o1.5 (land diameter o2.5) 16.51 3.5 2 7-o1.0 (land diameter o2.0) 1.0 0.5 b 4 2.7 a 2.54 5.08 2.54 2.54 (3.22) 1.905 a 3 7.62 (3.22) 12.7 7.62 13.08 12.7 16.51 1.905 Outer shape of product 10.16 3.5 t=0.3 2.54 5.08 2.54 CC1R5-xxxxxF-E (DIP type) b Unit: mm Allowable tolerance is 0.5 if not specified separately. 2.7 CC1R5-xxxxxR-E (SMD type) 16.60.2 Recommended measurements for mounting board (3.22) 2 5 7-0.3x0.6 6 1 (3.22) 3.2 7 6 -Vin 2 3 5 No.1 No.2 No.3 No.4 No.5 No.6 No.7 TRM -Vout 4 NC +Vin +Vin RC -Vin NC -Vout TRM +Vout 7 1 6 RC 5 2 4 3 -Vin Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature ( C) Output power derating by ambient temperature (common specification) All specifications are subject to change without notice. Terminal connections +Vout TRM COM -Vout Load RC +Vout CC1R5-xxxxDx-E Load 7 Terminal connections Load 1 3.2 Unit: mm Allowable tolerance is 0.5 if not specified separately. Connection diagram CC1R5-xxxxSx-E +Vin 15.6 22.0 2.54 5.08 2.54 4 2.54 5.08 2.54 1.8 3 7.62 2.54 (3.22) 1.8 (13.38) Coplanarity: 0.1 or lower 19.81 1.2 16.51 Outer shape of product 10.16 t=0.3 7.62 8.8max. 4.0 Shape/Dimensions No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC -Vin -Vout Common out TRM +Vout CC3-EDIP/SMD CC3-E Specifications MODEL CC3-0503Sx-E CC3-0505Sx-E CC3-0512Sx-E CC3-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) 73 77 82 81 Current (typ) (*1) A 0.723 0.779 0.732 0.741 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-1203Sx-E CC3-1205Sx-E CC3-1212Sx-E CC3-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) 74 79 82 81 Current (typ) (*1) A 0.297 0.316 0.305 0.309 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC3-EDIP/SMD MODEL CC3-2403Sx-E CC3-2405Sx-E CC3-2412Sx-E CC3-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-4803Sx-E CC3-4805Sx-E CC3-4812Sx-E CC3-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) 73 79 81 80 Current (typ) (*1) A 0.075 0.079 0.077 0.078 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC3-EDIP/SMD Outline Drawing CC3-xxxxxF-E (DIP type) 16.60.2 Recommended measurements for mounting board 2.92 20.32 22.86 2.54 a 2-o1.5 (land diameter o2.5) 5 7-0.3x0.6 6 7 b 22.86 1.0 0.5 2 7.62 4 3.5 b 3 1 (3.22) 2.7 a 7-o1.0 (land diameter o2.0) 0.5 17.78 2.54 5.08 2.54 2.54 (3.22) 2.54 Outer shape of product 2.54 5.08 2.54 13.08 17.78 10.16 3.5 t=0.3 7.62 8.5max. 4.0 Shape/Dimensions b 2.7 Unit: mm Allowable tolerance is 0.5 if not specified separately. a CC3-xxxxxR-E (SMD type) 16.60.2 (3.22) Recommended measurements for mounting board 7.62 2.54 5.08 2.54 Coplanarity: 0.1 or lower Outer shape of product 1.2 22.86 (13.38) t=0.3 10.16 8.8max. 4.0 Shape/Dimensions 26.16 1.8 1.8 3.2 22.0 3.2 4 2 5 7-0.3x0.6 6 1 (3.22) 2.54 5.08 2.54 3 7.62 2.54 (3.22) 28.4 7 Connection diagram CC3-xxxxSx-E +Vin 7 -Vin 5 2 3 No.1 No.2 No.3 No.4 No.5 No.6 No.7 TRM -Vout 4 NC CC3-xxxxDx-E +Vin +Vin RC -Vin NC -Vout TRM +Vout 7 1 6 RC 5 2 4 3 -Vin Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature ( C) Output power derating by ambient temperature (common specification) All specifications are subject to change without notice. Terminal connections +Vout TRM COM -Vout Load RC +Vout Load 6 Terminal connections Load 1 Unit: mm Allowable tolerance is 0.5 if not specified separately. No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC -Vin -Vout Common out TRM +Vout CC3-ESIP CC3-E Specifications MODEL CC3-0503SS-E CC3-0505SS-E CC3-0512SS-E CC3-0512DS-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) 73 77 82 81 Current (typ) (*1) A 0.723 0.779 0.732 0.741 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.67 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-1203SS-E CC3-1205SS-E CC3-1212SS-E CC3-1212DS-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) 73 79 82 Current (typ) (*1) A 0.301 0.316 0.305 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.67 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC3-ESIP MODEL CC3-2403SS-E CC3-2405SS-E CC3-2412SS-E CC3-2412DS-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.67 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-4803SS-E CC3-4805SS-E CC3-4812SS-E CC3-4812DS-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) 73 79 82 Current (typ) (*1) A 0.075 0.079 0.076 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC3-ESIP 10 Outline Drawing CC3-xxxxxS-E (SIP type) 9.2 17.9 Shape/Dimensions (0.5) 3.5 (0.5) 4.1 P P P P 2P P 22.86 P P 2.47 P 6 17.78 P=2.54 27.8 3 4 5 7 8 9 10 a 0.5 2 Recommended measurements for mounting board a 9.2 1 5.01 27.8 2.47 22.86 2.47 17.78 4 2-o1.5 (land diameter o2.5) P=2.54 SMD mounting space P P P P 2P P P P 9.2 Unit: mm Allowable tolerance is 0.5 if not specified separately. 6.0 2.47 1(t=0.3) 9-o0.8 (land diameter o2.0) Load 7 Load Load Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature ( C) Output power derating by ambient temperature (common specification) All specifications are subject to change without notice. 8 9 +Vin 5 -Vin 4 +Vin 3 RC 2 TRM 1 -Vout 10 COM 9 +Vout NC NC -Vout TRM NC RC -Vin +Vin +Vin COM 8 Terminal connections +Vout 7 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 No.10 +Vin 5 -Vin 4 +Vin 3 RC 2 -Vout 1 CC3-xxxxDS-E Terminal connections TRM +Vout Connection diagram CC3-xxxxSS-E 10 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 No.10 +Vout COM COM -Vout TRM NC RC -Vin +Vin +Vin 11 CC6-E CC6-E Specifications MODEL CC6-0503Sx-E CC6-0505Sx-E CC6-0512Sx-E CC6-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) 76 79 82 Current (typ) (*1) A 1.042 1.266 1.463 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 1.200 1.000 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 5 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC6-1203Sx-E CC6-1205Sx-E CC6-1212Sx-E CC6-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) 78 82 85 Current (typ) (*1) A 0.423 0.610 0.588 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 1.200 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC6-E MODEL CC6-2403Sx-E CC6-2405Sx-E CC6-2412Sx-E CC6-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 77 81 87 86 Current (typ) (*1) A 0.214 0.309 0.287 0.291 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 1.200 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC6-4803Sx-E CC6-4805Sx-E CC6-4812Sx-E CC6-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) 77 81 86 Current (typ) (*1) A 0.107 0.154 0.145 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 1.200 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. 12 13 CC6-E Outline Drawing CC6-xxxxxF-E (DIP type) 21.10.2 Recommended measurements for mounting board 20.32 2.63 8.5max. 4.0 Shape/Dimensions 10.16 5.08 17.78 15.24 17.87 3.5 t=0.3 5.08 Outer shape of product 7-o1.0 (land diameter o2.0) a b 2.7 0.5 2.54 5.08 4 7-0.3x0.6 2 22.86 1.0 5 a 5.08 10.16 2-o1.5 (land diameter o2.5) 3.5 b 3 0.5 5.08 (2.93) 2.54 5.08 22.86 2.7 5.08 6 (2.93) 1 Unit: mm Allowable tolerance is 0.5 if not specified separately. 7 b a CC6-xxxxxR-E (SMD type) 21.10.2 (2.93) Recommended measurements for mounting board Outer shape of product 3 4 7-0.3x0.6 3.2 22.0 3.2 28.4 5 10.16 5.08 2 (2.93) 5.08 5.08 1.8 5.08 5.08 (2.93) 1.8 1.2 (18.17) Coplanarity: 0.1 or lower 10.16 22.86 26.16 15.24 t=0.3 5.08 8.8max. 4.0 Shape/Dimensions 5.08 6 1 7 Unit: mm Allowable tolerance is 0.5 if not specified separately. Connection diagram CC6-xxxxSx-E +Vin 7 -Vin 5 2 3 -Vout 4 NC +Vin +Vin RC -Vin NC -Vout TRM +Vout Terminal connections 7 1 6 RC 5 2 4 3 -Vin Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature ( C) Output power derating by ambient temperature (common specification) All specifications are subject to change without notice. +Vout TRM COM -Vout Load RC TRM Load 6 No.1 No.2 No.3 No.4 No.5 No.6 No.7 CC6-xxxxDx-E Load 1 Terminal connections +Vout No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC -Vin -Vout Common out TRM +Vout 14 CC10-E CC10-E Specifications MODEL CC10-0503Sx-E CC10-0505Sx-E CC10-0512Sx-E CC10-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) 84 83 Current (typ) (*1) A 1.964 2.381 2.286 2.313 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 2.500 2.000 0.800 0.640 0.400 0.320 Maximum Power (*2) W 8.25 10 9.6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC10-1203Sx-E CC10-1205Sx-E CC10-1212Sx-E CC10-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) 84 86 88 86 Current (typ) (*1) A 0.318 0.969 1.136 1.047 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 2.500 2.000 1000 800 450 360 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. CC10-E MODEL CC10-2403Sx-E CC10-2405Sx-E CC10-2412Sx-E CC10-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 84 86 87 86 Current (typ) (*1) A 0.409 0.484 0.575 0.523 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 2.500 2.000 1.000 0.800 0.450 0.360 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC10-4803Sx-E CC10-4805Sx-E CC10-4812Sx-E CC10-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) 84 86 88 86 Current (typ) (*1) A 0.205 0.242 0.284 0.262 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 2.500 2.000 1.000 0.800 0.450 0.360 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. All specifications are subject to change without notice. 15 16 CC10-E Outline Drawing CC10-xxxxxF-E (DIP type) Recommended measurements for mounting board 30.48 25.4 Outer shape of product 5.08 5.08 5.08 18.62 3.5 t=0.3 15.24 4.0 8.5max. 22.60.2 10.16 3.38 Shape/Dimensions 7-o1.0 (land diameter o2.0) 35.56 25.4 5.08 2-o1.5 (land diameter o2.5) 0.5 5.08 a 4 5 6 7-0.3x0.6 1 b a 7 b 2.7 0.5 (3.68) 10.16 2 2.7 3.5 3 b 5.08 5.08 5.08 5.08 (3.68) 35.56 a Unit: mm Allowable tolerance is 0.5 if not specified separately. 1.0 CC10-xxxxxR-E (SMD type) Shape/Dimensions Recommended measurements for mounting board 1.8 3 4 2 5 6 7-0.3x0.6 7 1 3.2 5.08 5.08 5.08 (3.68) 10.16 5.08 (3.68) 1.8 CC10-xxxxDx-E 7 3 TRM No.1 No.2 No.3 No.4 No.5 No.6 No.7 -Vout 4 NC +Vin +Vin RC -Vin NC -Vout TRM +Vout 7 1 6 RC -Vin 5 2 4 3 Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature ( C) Output power derating by ambient temperature (common specification) All specifications are subject to change without notice. Terminal connections +Vout TRM COM -Vout Load -Vin 5 2 Terminal connections +Vout Load 6 RC 3.2 Unit: mm Allowable tolerance is 0.5 if not specified separately. Load 1 34.6 41.0 Connection diagram CC10-xxxxSx-E +Vin 5.08 5.08 5.08 (18.92) Coplanarity: 0.1 or lower 38.86 Outer shape of product 1.2 35.56 15.24 t=0.3 10.16 8.8max. 4.0 (3.68) 22.60.2 No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC -Vin -Vout Common out TRM +Vout 17 CC15-E CC15-E Specifications MODEL CC15-2403Sx-E CC15-2405Sx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 89 Current (typ) (*1) A 0.695 0.702 Nominal Voltage VDC 3.3 5 Maximum Current A 4.500 3.000 Maximum Power (*2) W 14.85 15 Maximum Line Regulation(Within input voltage range) mV 65 100 Maximum Load Regulation (0-100% load) mV 120 200 Output Temperature Coefficient 80mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max)(*3) +5/-3 Maximum Ripple & Noise (typ/max) (*4) mVp-p 40/120 Voltage Adjustable Range Not available Over Current Protection (*5) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 12.5 Mechanical Size (W x H x D) mm DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) Output voltage includes input change, load change (balanced load), and temperature change. (*4) In 50MHz, Ta=25 C. (*5) Latch method Resumes by restarting input or resetting remote on/off. All specifications are subject to change without notice. 18 CC15-E Outline Drawing CC15-xxxxxSF-E (DIP type) Recommended measurements for mounting board 6.075 27.33 25.4 6.075 37.55 17-0.3x0.6 b a 10.16 2-o1.5 (land diameter o2.5) 1.0 b 6.075 31.475 P=2.54 37.55 2.7 17 a 0.5 11 12 13 14 15 16 25-o1.0 (land diameter o2.0) 3.5 b Outer shape of product 0.5 a 2.54 10 9 8 7 6 5 4 3 2 1 2.7 22.86 t=0.3 10.16 3.0 (4.62) 2.54 (4.62) P P P P P P P P 4.47 32.1 7.0max. 38.1 P P P P P Shape/Dimensions Unit: mm Allowable tolerance is 0.5 if not specified separately. CC15-xxxxxSR-E (SMD type) Recommended measurements for mounting board (4.62) 27.33 11 12 13 14 15 16 2.54 10 9 8 7 6 5 4 3 2 1 17-0.3x0.6 10.16 Coplanarity: 0.1 or lower 10.16 2.54 (4.62) 40.9 22.86 t=0.3 Outer shape of product 3.2 17 1.8 +Vin -Vout Load -Vin Terminal connections 17 16 15 14 13 12 11 +Vout No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 NC NC RC NC NC +Vin +Vin -Vin -Vin No.10 No.11 No.12 No.13 No.14 No.15 No.16 No.17 NC NC +Vout +Vout +Vout -Vout -Vout NC Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature ( C) Output power derating by ambient temperature (common specification) All specifications are subject to change without notice. 3.2 P=2.54 Unit: mm Allowable tolerance is 0.5 if not specified separately. Connection diagram 1 2 3 4 5 6 7 8 9 10 36.6 43.0 1.8 RC P P P P P 7.5max. 32.1 1.2 38.1 P P P P P P P P P 4.47 Shape/Dimensions 19 CC25-E CC25-E Specifications MODEL CC25-2403Sx-E CC25-2405Sx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 90 Current (typ) (*1) A 1.146 1.157 Nominal Voltage VDC 3.3 5 Maximum Current A 7.500 5.000 Maximum Power (*2) W 24.75 25 Maximum Line Regulation (Within input voltage range) mV 65 100 Maximum Load Regulation (0-100% load) mV 120 200 Output Temperature Coefficient 80mV (Ambient temperature -40 to +50 ) Max Power Total Regulation (max)(*3) +5/-3 Maximum Ripple & Noise (typ/max) (*4) mVp-p 40/120 Voltage Adjustable Range VDC Not available Over Current Protection (*5) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Temperature -40 to +85 Storage Temperature -40 to +85 Operating Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Environment Storage Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 3 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 20 Mechanical Size (W x H x D) mm DIP: 42.65 x 7.0 x 44.9 / SMD: 42.65 x 7.5 x 44.9 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) Output voltage includes input change, load change (balanced load), and temperature change. (*4) In 50MHz, Ta=25 C. (*5) Latch method Resumes by restarting input or resetting remote on/off. All specifications are subject to change without notice. 20 CC25-E Outline Drawing CC25-xxxxSF-E (DIP type) Shape/Dimensions Recommended measurements for mounting board 43.2 30.5 5.08 PPPPP 6.075 6.075 6 5 4 3 2 1 35.56 PPP 6.075 36.575 42.65 P=2.54 25 b a Unit: mm Allowable tolerance is 0.5 if not specified separately. Recommended measurements for mounting board 43.2 7.5max. 4.52 44.9 Outer shape of product 35.56 40.08 (4.67) 48.1 25 Terminal connections -Vout No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 Load 25 24 23 22 21 20 19 18 17 16 15 14 3.2 P=2.54 Unit: mm Allowable tolerance is 0.5 if not specified separately. Connection diagram 1 2 RC 3 4 5 -Vin 6 7 8 9 10 11 12 +Vin 13 41.7 3.2 (4.67) 6 5 4 3 2 1 PPP 9 8 7 14 15 16 17 18 19 20 21 22 23 24 10.16 13 12 11 10 P P P P P P P P P P 10.16 Coplanarity: 0.1 or lower 1.8 5.08 PP 46.0 5.08 PPPPP t=0.3 1.8 5.08 2-o1.5 (land diameter o2.5) 2.7 Shape/Dimensions 5.08 5.08 PP 1.0 a CC25-xxxxSR-E (SMD type) 2.54 25-o1.0 (land diameter o2.0) 10.16 9 8 7 25-0.3x0.6 2.7 b 3.5 14 15 16 17 18 19 20 21 22 23 24 0.5 b 0.5 a (4.67) 13 12 11 10 40.08 42.65 P P P P P P P P P P 10.16 Outer shape of product t=0.3 (4.67) 2.54 5.08 5.08 3.0 7.0max. 4.52 44.9 +Vout NC NC NC RC NC NC -Vin -Vin -Vin No.10 No.11 No.12 No.13 No.14 No.15 No.16 No.17 No.18 +Vin +Vin +Vin NC NC +Vout +Vout +Vout +Vout No.19 No.20 No.21 No.22 No.23 No.24 No.25 Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature ( C) Output power derating by ambient temperature (common specification) All specifications are subject to change without notice. -Vout -Vout -Vout -Vout -Vout -Vout NC 21 CC-E CC-E Instruction Manual 1. Control functions/Protection functions/Connections 1. Remote On/Off terminal (RC) 1.5-10W type 1-2. O utput voltage adjusting terminal (TRM) (1.5-10W type) Output voltage can be set to the values shown in the figure Open collector is recommended as the connection system. below by connecting the TRM terminal to the -Vout termi- Consult us for use with other systems. nal. Use a transistor with "VCE: Vin or over" and "Ic: 1mA or over". When not using this function (always on), set the TRM terminal to open. Output is switched off by setting the RC terminal open, and Note that when the output voltage is set high by this func- switched on by setting the RC terminal to LOW (0-0.4V). tion, derating of output current is necessary according to the maximum power. +Vout DIP/SMDmodels Load RC -Vin -Vout When not using this function (always on), short-circuit between RC terminal and -Vin terminal. +Vin +Vout RC +Vin 3.6V 6V 15V +Vout Load TRM TRM -Vout +Vin -Vin +12V +Vout and switched off by setting the RC terminal to HIGH (con- TRM necting to Vin terminal). -Vout +Vout Load RC -Vout When not using this function (always on), set the RC termi- +Vin Load -Vout -12V SIPmodels Model name CC3-xx03SS-E CC3-xx05SS-E CC3-xx12SS-E CC3-xx12DS-E Model name 3.3V 5V 12V 12V +15V +Vout TRM Load COM -Vin nal to open. Load COM -Vin Load -Vout -15V Connection to -Vout 3.67V 6V 15V 15V Fig. 3 3 3 4 Load +Vin -Vin TRM +Vout +Vin -Vin TRM -Vout 3.67V, 6V, 15V Load Load -12V +15V Load -15V +Vin -Vin TRM -Vout COM COM Load +Vout Fig.4 +12V All specifications are subject to change without notice. Load 3.3V, 5V, 12V +Vin -Vout +Vout -Vin TRM RC -Vout +Vout -Vout +Vin +Vout Fig.3 Load When not using this function (always on) +Vin Fig.2 Output is switched on by setting the RC terminal to open, -Vin 3.3V 5V 12V +Vout -Vout 15/25W type RC control signal Fig. 1 1 1 2 Fig.1 -Vin +Vin Connection to -Vout 3.6V 6V 15V 15V Load -Vin Open 3.3V 5V 12V 12V To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Load When not using this function (always on) Model name CC -xx03Sx-E CC -xx05Sx-E CC -xx12Sx-E CC -xx12Dx-E -Vin RC control signal +Vin 22 CC-E For the 12V output model, output voltage can be set to Adding a resistance Rb between TRM terminal and 24V single output by making the COM terminal and TRM +Vout terminal, to set the output voltage low terminal open. And output voltage can be set to 30V single *5 Vout = 3.3 - 15.53/(39.6+Rb) [Rb 62] output by making the COM terminal open and connecting *6 Vout = 5.01 - 52.55/(31.8+Rb) [Rb 160] the TRM terminal to the -Vout terminal. *7 Vout = 12.01 - 431.1/(57+Rb) [Rb 620] *8 Vout = 12.02 - 968.5/(103+Rb) [Rb 1500] models Model name Calculating connected resistance Ra, Rb (k) from set out- COM terminal TRM terminal Single output Fig. Open Open Open Connection to -Vout put voltage Vout (V) * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Fig.5 +Vout 24V +Vout 30V TRM Load COM -Vin +Vin Load TRM COM -Vin -Vout -Vout +Vin TRM -Vin -Vout COM +Vout +Vin -Vin TRM -Vout *6 Rb = 52.55/(5.01-Vout) - 31.8 *7 Rb = 431.1/(12.01-Vout) - 57 Fig.9 Fig.10 +Vout Output voltage can be varied in the range shown in the figure below by connecting a resistance (Ra, Rb) between the TRM terminal and the -Vout terminal or between the TRM terminal and +Vout terminal. Note that when the output voltage is set high, derating of output current is necessary according to the maximum power. models Connection between Fig. +Vout and Rb to to to to * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Calculating output voltage Vout (V) from connected resistance Ra, Rb (k) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high TRM -Vout Fig.11 Ra *1, *2, *3 TRM Fig.12 Load Ra *4 Rb 3.153.3V 4.755V 11.412V -Vout Load COM -Vout TRM +12+15V +Vout *5, *6, *7 +Vout Load 30V 1-3. Output voltage adjusting function (adding external resistance) (1.5-10W type) 3.33.6V 56V 1215V Load Load 24V Connection between Fig. -Vout and Ra to to to to *5 Rb = 15.53/(3.3-Vout) - 39.6 *8 Rb = 968.5/(12.02-Vout) - 103 Fig.8 COM +Vout *4 Ra = 53.55/(Vout-12.02) - 18 terminal, to set the output voltage low COM terminal TRM terminal Single output Fig. Open Open Open Connection to -Vout Fig.7 Model name *2 Ra = 17.64/(Vout-5.01) - 17.8 *3 Ra = 50.53/(Vout-12.01) - 16.9 Adding a resistance Rb between TRM terminal and +Vout models Model name Load terminal, to set the output voltage high *1 Ra = 9.59/(Vout-3.3) - 32 Fig.6 +Vin Adding a resistance Ra between TRM terminal and -Vout -12-15V +Vout TRM *8 Rb COM -Vout +11.4+12V Load Load -11.4-12V models Model name Connection between Fig. -Vout and Ra to to to to Connection between Fig. +Vout and Rb to to to to Calculating output voltage Vout (V) from connected resistance Ra, Rb (k) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high *1 Vout = 3.3 + 1.04/(2.83+Ra) * To be 3(3W), 6(6W), or 10(10W) for actual model names. *2replaced Vout with = 51R5(1.5W), + 12.75/(12.69+Ra) *3 Vout = 12 + 48.4/(16.18+Ra) *4 Vout = 12 + 54.7/(18+Ra) *1 Vout = 3.3 + 9.59/(32+Ra) *2 Vout = 5.01 + 17.64/(17.8+Ra) Adding a resistance Rb between TRM terminal and *3 Vout = 12.01 + 50.53/(16.9+Ra) +Vout terminal, to set the output voltage low *4 Vout = 12.02 + 53.55/(18+Ra) *5 Vout = 3.3 - 1.69/(3.66+Rb) [Rb 7.6] *6 Vout = 5 - 12.78/(17.79+Rb) [Rb 33.3] *7 Vout = 12 - 184.1/(35.54+Rb) [Rb 271.3] *8 Vout = 12 -470.3/(61.75+Rb) [Rb 722.1] All specifications are subject to change without notice. 23 CC-E Calculating connected resistance Ra, Rb (k) from set output voltage Vout (V) 1-5. Over voltage protection Adding a resistance Ra between TRM terminal and -Vout An over voltage protection function is not incorporated in terminal, to set the output voltage high the model. Be careful if an external voltage over the nomi- *1 Ra = 1.04/(Vout-3.3) - 2.83 nal voltage is applied, damage may be caused. *2 Ra = 12.75/(Vout-5) - 12.69 *3 Ra = 48.4/(Vout-12) - 16.18 *4 Ra = 54.7/(Vout-12) - 18 1-6. Low input voltage protection This series is equipped with the low input voltage protec- Adding a resistance Rb between TRM terminal and tion in order to prevent malfunction due to low input volt- +Vout terminal, to set the output voltage low *5 Rb = 1.69/(3.3-Vout) - 3.66 age. The converter stops operation if the input voltage become lower than the set voltage. The set ranges are *6 Rb = 12.78/(5-Vout) - 17.79 shown in the table below. *7 Rb = 184.1/(12-Vout) - 35.54 Model name *8 Rb = 470.3/(12-Vout) - 61.75 Load *5, *6, *7 3.153.3V4.755V11.412V TRM -Vout COM +Vout TRM -Vout and between terminal and case, is AC500V. Rb Ra *4 Load Load +12+15V -12-15V 1-7. Insulation withstand voltage The insulation withstand voltage between input and output, Fig.16 COM +Vout TRM Rb Ra *1, *2, *3 Load 3.33.67V56V1215V Fig.15 -Vout TRM +Vout Fig.14 -Vout +Vout Fig.13 Input voltage range Voltage range set for protection circuit to to to to to to to to to to to to To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Load Load +11.4+12V *8 -11.4-12V 1-4. Over current protection 1.5-10W type 1-8. Series/Parallel connections Series connection Serial connection is applicable by wiring as shown in the figure below (left). If output voltage is not generated by this connection, connect a Schottky diode in which the forward voltage is possibly low. An over current protection circuit is incorporated in the Also note that the Schottky diode should have a reverse model, and if over current occurs, the output voltage is voltage that is twice or over the value of the voltage be- lowered. By removing the over current and shorted condi- tween +Vout and -Vout. tions, the output voltage automatically resumes. Note that And the output current should be the same or lower than if the over current status continues for 30 seconds or over, the nominal current value, whichever is smaller in the con- the internal elements of the converter may be deteriorated verters. or damaged. The current value, from which it is judged as an over current, is not to be lower than the nominal current value. If the output voltage does not resume even after re- 15/25W type +Vin +Vout -Vin -Vout -Vin -Vout +Vin +Vout +Vin +Vout -Vin -Vout -Vin -Vout An over current protection circuit is incorporated in the model, and if over current occurs, the output voltage is lowered and the converter is stopped and latched. The Parallel connection output voltage does not automatically resume even after Parallel connection is not applicable. removing the over current and shorted conditions. To resume output voltage, restart input or reset remote on/ off. The current value, from which it is judged as an over current, is not to be lower than the nominal current value. All specifications are subject to change without notice. Load the power or remote control once, and then restart it. +Vout Load moving the over current conditions and any causes, turn off +Vin 24 CC-E 2. Noise reduction methods 2-1. Ripple noise measurement method 2-3. Output ripple & noise The measured value of the converter noise may differ de- To reduce Output ripple & noise, connect a capacitor to pending on the measurement method. Measurement should the output of the converter. In addition, reduction can be be conducted in a position close to the output terminal. enhanced if a type filter is incorporated as shown in the When connecting a prove, do not allow a loop to be config- figure below. In this case, use of a coil with around 100H ured in order not to pick up flux. is recommended. As well, note that the spike voltage greatly differs depending on the ripple voltmeter and frequency band of the oscil- +Vout -Vin -Vout Our noise measurement is conducted by the wiring shown in the figure below and in the frequency band of 50MHz. 10mm +Vin Iin V V -Vout -Vin A A lout +Vout Vout 0.1F 50 coaxial cable 1.5m -Vout Ripple voltmeter 50MHz verter is long, connect the capacitor as close as possible to the load. To reduce output spike noise, connect a ceramic capacitor with around 1F to the output of the converter. +Vin +Vout 1MF 2-2. Input ripple noise -Vin Load Oscilloscope or 50MHz End-point: 50+0.1F -Vin When the distance to the load from the output of the conLoad Vin 20mm +Vout Load loscope. +Vin Load +Vin -Vout This series is equipped with a built-in capacitor for input. Therefore, this series can operate without an external capacitor, input ripple noise and input return noise can be 2-4. C apacity of external capacitor connected to output reduced. In addition, it is more effective if a type filter is installed Note that if a capacitor with capacity over the value shown in the table below is connected to the output, or several as shown in the figure below. capacitors with low impedance are connected in parallel, capacitor connected to input. However, by connecting a operation of the converter may become unstable. +Vin +Vout +Vin +Vout Load Load -Vin -Vout -Vin -Vout When the distance to the input of the converter from the input power supply is long, attach a capacitor as close as possible to the input terminal. +Vout -Vin -Vout Load +Vin When the distance to the input of the converter from the input power supply is long, the impedance of the input line can become high, causing high spike noise. In this case, it is recommended to connect a capacitor as close as possible to the input of the DC-DC converter. All specifications are subject to change without notice. Model name Electrostatic capacitance (F) max. 25 CC-E 2-5. Common mode noise 2-6. Radiation noise For products other than with 10W, capacitors are not con- Radiation noise of the converter can be reduced by con- nected between the primary GND and the secondary GND. necting the case terminal to the input or output GND ter- To reduce common mode noise, connect a capacitor with minal. The effectiveness varies depending on the device. around 1000pF between the primary GND and the second- Check it on the actual device. ary GND, as shown in the figure below. Regarding wiring, use GND line and solid pattern for the In this case, note that if the capacitor that is connected is bottom of the converter as much as possible. too large, coupling capacitance between input and output - SMD models are not equipped with case terminals. becomes large. Also be careful about the withstand voltage of the capacitor (500V or over is desirable with consideration of the insulation withstand voltage). +Vout -Vin -Vout Load +Vin For products with 10W, capacitors with 1000pF are internally connected between primary and secondary. 3. Soldering conditions/Cleaning conditions 3-1. Soldering conditions Board cleaning after soldering is not recommended. How- Soldering conditions DIP models / SIP models Observe the following conditions in soldering board. Solder dip Soldering copper 260C, 10s max. 380C, 3s max. SMD models Lead-free soldering / High-temperature reflow process Surface temperature of parts 3-2. Cleaning method 30p20s ever, the cleaning fluids and conditions shown in the table below have been tested and proved to have no problem. These fluids and conditions can be used. Consult us for using cleaning fluids other than those shown below. Cleaning fluids and test conditions Cleanthrough 750H (1) Cleaning (shaking) at 60 C for 4 minutes (2) Rinsing (shaking in water) at 60 C for 4 minutes 245C max. (3) Rinsing (shaking in water) at ordinary temperature - 225C min. 40 C for 4 minutes 180C (4) Drying at 70 C for 6 minutes 150C Pine alpha ST100S (1) Cleaning (shaking) at 60 C for 5 minutes 1 to 3C/s 40 to 100s 1 to 4C/s 1 to 5C/s (2) Rinsing (shaking in water) at 30 C for 3 minutes (3) Drying at 70 C for 6 minutes Terpene Cleaner EC-7R (1) Cleaning (shaking) at 60 C for 5 minutes (2) Rinsing (shaking in IPA) at 30 C for 10 minutes (3) Drying at 70 C for 6 minutes Isopropyl alcohol (1) Ultrasonic waves at 60 C for 1 minute (2) Cool bath cleaning R.T. for 1 minute (3) Vapor cleaning at 83 C for 1 minutes Asahiklin AK-225AES (1) Ultrasonic waves at 50 C for 2 minutes (2) Cool bath cleaning R.T. for 2 minutes All specifications are subject to change without notice.