Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
Sensing and Control
FEATURES
Rugged, isolated stainless
steel package
Reliable semiconductor
technology
Calibrated and
temperature compensated
Voltage or current supply
options
Absolute and sealed gage
pressures
Low-cost cell package
Absolute pressure
0 psi to 500 psi, 1000 psi,
2000 psi, 3000 psi, and
5000 psi
TYPICAL APPLICATIONS
Industrial controls
Hydraulic controls
Tank pressure
Pressure transmitters
Process control systems
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Honeywell’s 13 mm Series stainless steel pressure sensors are designed
for high pressure applications that involve measurement of hostile media in
harsh environments. This series uses Honeywell’s proven piezoresistive
semiconductor sensor chip in an oil-isolated housing with or without an
integral ceramic for temperature compensation and calibration. This design
has proven to be highly reliable, stable and accurate.
These sensors feature a weld-ring collar and special back support ring for
high cycle life capability as they are designed for further package integration
in OEM (Original Equipment Manufacturer) applications. Products are
available with pressure ranges from 500 psi through 5000 psi and can be
used with voltage or current supplies.
EQUIVALENT CIRCUIT
13 mm compensated series 13 mm uncompensated series
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
2 Honeywell Sensing and Control
PRESSURE SENSOR CHARACTERISTICS (all devices)
Environmental specifications
Compensated temperature range 0 °C to 82 °C [32 °F to 180 °F]
Operating temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Storage temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Vibration 10 G at 20 Hz to 2000 Hz
Shock 100 G for 11 ms
Life 1 million cycles min.
Insulation resistance 100 m at 50 Vdc
Maximum ratings
Voltage version “K” Supply voltage VS = +15 Vdc
Voltage version “L” Supply current IS = +2.0 mA
PERFORMANCE CHARACTERISTICS – COMPENSATED SERIES (1)
Characteristic Minimum Typical Maximum Units
Zero pressure offset -2 0 +2 mV
Pressure non-linearity (3)±0.1 ±0.25 %FSS
Pressure hysteresis (3)±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
Temp. effect on span (4)±0.5 ±1.0 %FSS
Temp. effect on offset (4)±0.5 ±1.0 %FSS
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) ±0.1 ±0.3 %FSS
Long-term stability of offset and span (5)±0.1 ±0.3 %FSS
Response time (6) – 0.1 – ms
Common mode voltage (voltage version “K”) (9) 0.50 1.25 2.0 Vdc
Input resistance (current version “L”) 2.0 4.5 8.0 k
Input resistance (voltage version “K”) 8.0 25 50 k
Output resistance 3.0 4.5 6.0 k
PRESSURE RANGE SPECIFICATIONS – COMPENSATED SERIES
Catalog Listing Pressure range Full scale span (2) Proof pressure
(7) Burst pressure
(8)
13C 0500P (A,S) (1,4,5,6) (K,L) 0 psi to 500 psi 98 mV to 102 mV 1500 psi 2500 psi
13C 1000P (A,S) (1,4,5,6) (K,L) 0 psi to 1000 psi 98 mV to 102 mV 3000 psi 5000 psi
13C 2000P (A,S) (1,4,5,6) (K,L) 0 psi to 2000 psi 98 mV to 102 mV 6000 psi 10,000 psi
13C 3000P (A,S) (1,4,5,6) (K,L) 0 psi to 3000 psi 98 mV to 102 mV 9000 psi 10,000 psi
13C 5000P (A,S) (1,4,5,6) (K,L) 0 psi to 5000 psi 148 mV to 152 mV 10,000 psi 10,000 psi
NOTES
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; Supply VS = 10 Vdc ±0.01 Vdc or IS = 1.5 mA
±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
9. Common mode voltage as measure from output to ground.
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
Honeywell Sensing and Control 3
PERFORMANCE CHARACTERISTICS – UNCOMPENSATED SERIES (1)
Characteristic Minimum Typical Maximum Unit
Zero pressure offset -7.5 0 +7.5 mV/V
Pressure non-linearity (3)±0.1 ±0.25 %FSS
Pressure hysteresis (3)±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
Temp. coefficient of span (4)
(0 °C to 82 °C [32 °F to 180 °F])
360 720 1260 ppm/°C
Temp. coefficient of resistance (4)
(0 °C to 82 °C [32 °F to 180 °F])
2700 3420 4500 ppm/°C
Temp. coefficient of offset (4)
(0 °C to 82 °C [32 °F to 180 °F])
– 30 µV/V/°C
Thermal hysteresis
(0 °C to 82 °C [32 °F to 180 °F])
– ±0.1 ±0.3 %FSS
Long-term stability of offset and span (5) ±0.1 ±0.3 %FSS
Response time (6) – 0.1 – ms
Input resistance 4.0 4.75 6.0 k
Output resistance 4.0 4.75 6.0 k
PRESSURE RANGE SPECIFICATIONS – UNCOMPENSATED SERIES
Catalog Listing Pressure range Full scale span (2) Proof pressure
(7) Burst pressure
(8)
13U 0500P A 0 K 0 psi to 500 psi 175 mV to 300 mV 1200 psi 2400 psi
13U 1000P A 0 K 0 psi to 1000 psi 175 mV to 300 mV 3000 psi 5000 psi
13U 2000P A 0 K 0 psi to 2000 psi 175 mV to 300 mV 6000 psi 10,000 psi
13U 3000P A 0 K 0 psi to 3000 psi 175 mV to 300 mV 9000 psi 10,000 psi
13U 5000P A 0 K 0 psi to 5000 psi 290 mV to 500 mV 10,000 psi 10,000 psi
NOTES
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; Supply VS = 10 Vdc ±0.01 Vdc or IS = 1.5 mA
±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
4. The error band resulting from maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
temperature is varied from 25 °C [77 °F] to any other temperature within the specified range 0 °C to 82 °C [32 °F to
180 °F]. This parameter is not 100 % tested and is guaranteed by process design and tested on a sample basis only.
Temperature coefficient of span is evaluated using a constant current source.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
4 Honeywell Sensing and Control
PHYSICAL DIMENSIONS for reference only, in (mm)
Package 1 (see note): Ring with back support
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and
lower portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-
concentricity).
Package 4: 1/8-27 NPT
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
Honeywell Sensing and Control 5
Package 5: 1/4-18 NPT
Package 6: 7/16-20 UNF
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
6 Honeywell Sensing and Control
Package 0 (see note): Ring and cell
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and
lower portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-
concentricity).
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 13 mm Series
Honeywell Sensing and Control 7
ORDERING INFORMATION
13 mm Compensated Series
For example: Part #13C3000PS4K = 13 mm Cell, Compensated, 3000 psi, Sealed Gauge, 1/8NPT Port with 10 Vdc
excitation.
13 mm Uncompensated Series
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
Sensing and Control
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
008131-1-EN IL50 GLO 1004 Printed in USA
Copyright 2004 Honeywell International Inc. All Rights Reserved.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are returned
to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective. The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application. For application
assistance, current specifications, or name of the
nearest Authorized Distributor, contact a nearby
sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com