SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 100ms/230VAC 4000ms, 100ms/115VAC at full load
12ms/230VAC
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
0.94/230VAC
4A/115VAC 2A/230VAC
22A/115VAC 44A/230VAC
<2mA / 240VAC
105 ~ 120% rated output power
5.7 ~ 7V3.7 ~ 4.6V 13.5 ~ 16.3V
105 ~ 130% rated output power
17 ~ 21V 26.7 ~ 32.4V 53 ~ 64.8V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Shut down o/p voltage with auto-recovery
UL60950-1, TUV EN60950-1 approved
,EAC TP TC 004
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020
-10 ~ +65 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
106.3K hrs min. MIL-HDBK-217F (25 )℃
235.2*101.5*38mm (L*W*H)
1.1Kg; 16pcs/18Kg/0.72CUFT
78% 88%84%
0.95/230VAC 0.98/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
88% 88% 89%
±1.0% ±1.0% ±1.0% ±1.0%
±0.5%±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0%±2.0%
±2.0%±2.0%
±2.0% ±2.0% ±2.0% ±2.0%
80mVp-p80mVp-p
4.5 ~ 5.5V2.97 ~ 3.6V
100mVp-p
10.8 ~ 13.2V
100mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
150mVp-p
43.2 ~ 52.8V
5V3.3V
70A70A
0 ~ 50A
0 ~ 70A
0 ~ 50A
0 ~ 70A
250W
350W
165W
231W
12V
29.2A
0 ~ 25A
0 ~ 29.2A
300W
350.4W
15V
23.4A
0 ~ 20A
0 ~ 23.4A
300W
351W
24V
14.6A
0 ~ 12.5A
0 ~ 14.6A
300W
350.4W
48V
7.3A
0 ~ 6.25A
0 ~ 7.3A
300W
350.4W
USP-350-5USP-350-3.3 USP-350-12 USP-350-15 USP-350-24 USP-350-48
350W Single Output with PFC Function
Universal AC input / Full range
Built in active PFC circuit compliance to EN61000-3-2
Protections: Short circuit / Overload / Over voltage / Over temperature
Free air convection for 300W and 350W with 23.5CFM forced air
High power density 6.3w/in3
ZVS technology to reduce power dissipation
Active AC surge current limiting
U-bracket low profile:38mm
3 years warranty
■ Features :
USP-350 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
CURRENT RANGE (23.5CFM FAN)
RATED POWER (convection)
CURRENT RANGE (convection)
RATED POWER (23.5CFM FAN)
EMC IMMUNITY
EMC EMISSION
File Name:USP-350-SPEC 01-152018-
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os