Rubber Cord Cord & Cordset Super Vu-Tron(R) Supreme Types SJOOW/SOOW 105C 300 and 600 Volt UL /CSA Portable Cord Product Construction: Conductors: *18 through 10 AWG fully annealed stranded tinned copper per ASTM B-174 Insulation: *Premium-grade, color-coded, oil-resistant 105C EPDM *European color code: See chart below Jacket: *Super Vu-Tron(R) Supreme, yellow *Temperature range: -50C to +105C UL/CSA *Voltage rating: 300 volts Type SJOOW 600 volts Type SOOW Jacket Marking: *CAROL SUPER VU-TRON(R) SUPREME (SIZE) (mm2) 105C (UL) WATER RESISTANT SJOOW (OR SOOW) CSA -50C FT-1 --- P-123-103 MSHA (VOLTS) RoHS MADE IN USA Applications: *Machine tools * Power tools * Dockside power applications * Motor leads * Portable machinery * Cranes * Submersible pumps * Where water immersion is required *Severe environment OEM/MRO applications Features: * Excellent flexibility in cold temperatures *Lasts longer in flex applications (Class M stranding) * Integral Flexfill(R) *Ozone-sunlight (UV)- and weather-resistant *ULListed and CSA Certified for indoor and outdoor use * Water-resistant *Safety-colored, with high-visibility yellow jacket * High heat and flame resistance *Resistant to sunlight, oils, acids and chemicals * Excellent abrasion and cut resistance * TRU-Mark(R) sequential footage marking *Tinned copper conductors -- corrosion/ oxidation-resistant Industry Approvals: * UL Flexible Cord - ULSubject 62 * CSA Flexible Cord - C22.2-49 * MSHA Approved * OSHA Acceptable * JC580 * RoHS Compliant Packaging: *250' (76.2 m), 500' (152.4 m), 1000' (304.8 m) *Other put-ups available on special order TYPE SJOOW - 300 VOLT - UL/CSA NOM. INS. JACKET NO. APPROX. COPPER THICKNESS NOMINAL O.D. CATALOG OF AWG COND. STRAND CURRENT NET WT. WT. STD. NUMBER COND. SIZE STRAND O.D. INCHES mm INCHES mm AMPS LBS/M'(S) LBS/M' CTN. 02601 02602 02603 2 3 4 18 18 18 41/34 41/34 41/34 .048" 0.030 0.76 0.310 .048" 0.030 0.76 0.320 .048" 0.030 0.76 0.345 7.87 8.13 8.76 10 10 7 60 70 85 10 15 20 1000' 1000' 250' 02604 02605 02606 2 3 4 16 16 16 65/34 65/34 65/34 .061" 0.030 0.76 0.315 .061" 0.030 0.76 0.335 .061" 0.030 0.76 0.370 8.00 8.51 9.40 13 13 10 67 83 100 16 24 32 1000' 250' 250' 02607 02608 02609 2 3 4 14 105/34 .078" 0.030 0.76 0.370 9.40 14 105/34 .078" 0.030 0.76 0.375 9.53 14 105/34 .078" 0.030 0.76 0.405 10.29 18 18 15 90 114 132 26 41 55 250' 250' 250' TYPE SOOW - 600 VOLT - UL/CSA NOM. INS. THICKNESS JACKET NOMINAL O.D. NO. CATALOG OF AWG COND. NUMBER COND. SIZE STRAND INCHES mm INCHES 02631* 02632 02633* 2 3 4 18 18 18 41/34 41/34 41/34 0.030 0.030 0.030 0.76 0.76 0.76 0.365 0.375 0.400 9.27 9.53 10.16 10 10 7 75 84 110 10 15 21 250' 250' 250' 02634 02635 02636 02621 2 3 4 5 16 16 16 16 65/34 65/34 65/34 65/34 0.030 0.030 0.030 0.030 0.76 0.76 0.76 0.76 0.370 0.395 0.425 0.515 9.40 10.03 10.80 13.08 13 13 10 8 86 105 127 181 16 24 32 40 250' 250' 250' 250' 02637* 02638 02639 02622* 2 3 4 5 14 14 14 14 105/34 105/34 105/34 105/34 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.510 0.525 0.575 0.675 12.95 13.34 14.61 17.15 18 18 15 12 155 176 218 285 26 41 55 66 250' 250' 250' 250' 02641* 02642 02643 02623* 2 3 4 5 12 12 12 12 168/34 168/34 168/34 168/34 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.590 0.600 0.650 0.730 14.99 15.24 16.51 18.54 25 25 20 16 200 243 295 315 41 67 90 103 250' 250' 250' 250' 02645 02646 02624* 3 4 5 10 10 10 259/34 259/34 259/34 0.045 0.045 0.045 1.14 1.14 1.14 0.660 0.710 0.770 16.76 18.03 19.56 30 25 20 299 413 432 99 132 168 250' 250' 250' TOP PERFORMANCE IN THE TOUGHEST ENVIRONMENTS Volume change (%) of SUPER VU-TRON(R) SUPREME after 28 days at room temperature in the following materials ACETIC ACID (30%) AMMONIA HYDROXIDE ASTM 3 OIL BEER BLEACH WATER BUTYL ALCOHOL CORN OIL FORMALDEHYDE GLYCOL (ANTI-FREEZE) HYDROCHLORIC ACID (20%) JP-4 KEROSENE +19.00 +3.12 +0.26 +4.42 +2.60 -1.82 0.00 +3.38 -2.60 +10.60 +10.90 +10.60 LINSEED OIL LUBE OIL MILK NITRIC ACID (10%) SAE 30 OIL SKYDROL 500 SODIUM HYDROXIDE SULFURIC ACID (10%) TOLUENE UNLEADED GAS WATER +1.04 -1.82 +4.16 +7.29 -1.30 +17.10 +10.90 +2.34 +30.20 +22.10 +2.86 OSHA *Non-stock item; minimum quantity purchase required. G reen conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. COLOR CODE CHART NO. OF CONDUCTORS COLOR 2 3 4 5 Black, White Black, White, Green/Yellow Black, White, Red, Green/Yellow Black, White, Red, Orange, Green/Yellow Acceptable Occupational Safety and Health Administration 9 APPROX. COPPER CURRENT NET WT. WT. STD. mm AMPS LBS/M'(S) LBS/M' CTN. Rubber Cord Cord & Cordset Super Vu-Tron(R) III Types SJOOW/SOOW 105C 300 and 600 Volt UL /CSA Portable Cord Product Construction: Conductors: *18 through 10 AWG fully annealed stranded bare copper per ASTM B-174 Insulation: *Premium-grade, color-coded, oil-resistant 105C EPDM *Color code: See chart below TYPE SJOOW - 300 VOLT - UL/CSA CATALOG NUMBER NOMINAL INS. THICKNESS NO. OF AWG COND. COND. SIZE STRAND INCHES Jacket: mm APPROX. NOMINAL O.D. CURRENT NET WT. INCHES mm AMPS LBS/M1(S) STD. CTN. 02001* 02002* 02003* 2 3 4 18 18 18 41/34 41/34 41/34 0.030 0.030 0.030 0.76 0.76 0.76 0.310 0.320 0.345 8.00 8.12 8.76 10 10 7 56 65 80 1000' 1000' 250' 02004* 02005* 02006* 2 3 4 16 16 16 65/34 65/34 65/34 0.030 0.030 0.030 0.76 0.76 0.76 0.315 0.335 0.370 8.00 8.51 9.40 13 13 10 68 80 95 1000' 250' 250' 02007* 02008* 02009* 2 3 4 14 14 14 41/30 41/30 41/30 0.030 0.030 0.030 0.76 0.76 0.76 0.370 9.40 0.375 9.52 0.405 10.29 18 18 15 90 110 130 250' 250' 250' TYPE SOOW - 600 VOLT - UL/CSA CATALOG NUMBER NO. OF AWG COND. SIZE NOMINAL INS. THICKNESS COND. STRAND INCHES mm APPROX. CURRENT NET WT. mm AMPS LBS/M1(S) NOMINAL O.D. INCHES STD. CTN. *Super Vu-Tron(R) III, yellow *Temperature range: -50C to +105C UL/CSA *Voltage rating: 300 volts Type SJOOW 600 volts Type SOOW Jacket Marking: *CAROL SUPER VU-TRON(R) III (SIZE) (mm2) 105C (UL) WATER RESISTANT SJOOW (OR SOOW) CSA -50C FT-1 --- P-123-103 MSHA (VOLTS) RoHS MADE IN USA Applications: Features: 02031* 02032* 02033* 2 3 4 18 18 18 41/34 41/34 41/34 0.030 0.030 0.030 0.76 0.76 0.76 0.365 9.27 0.375 9.53 0.400 10.16 10 10 7 75 80 110 250' 250' 250' 02034* 02035* 02036* 02021* 2 3 4 5 16 16 16 16 65/34 65/34 65/34 65/34 0.030 0.030 0.030 0.030 0.76 0.76 0.76 0.76 0.370 9.40 0.395 10.80 0.425 10.80 0.515 13.08 13 13 10 8 75 100 120 150 250' 250' 250' 250' 02037* 02038* 02039* 02022* 2 3 4 5 14 14 14 14 41/30 41/30 41/30 41/30 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.510 0.525 0.575 0.675 12.95 13.34 14.61 17.15 18 18 15 12 155 165 215 285 250' 250' 250' 250' 02041* 02042* 02043* 02023* 2 3 4 5 12 12 12 12 65/30 65/30 65/30 65/30 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.590 0.600 0.650 0.730 14.99 15.24 16.51 18.54 25 25 20 16 200 250 280 315 250' 250' 250' 250' 02045* 02046* 02024* 3 4 5 10 10 10 104/30 104/30 104/30 0.045 0.045 0.045 1.14 1.14 1.14 0.660 16.76 0.710 18.03 0.770 19.56 30 25 20 320 375 432 250' 250' 250' *Non-stock item available by special order; minimum quantity purchase required. G reen conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. *Machine tools * Power tools * Dockside power applications * Motor leads * Portable machinery * Cranes * Submersible pumps * Excellent flexibility in cold temperatures * Last longer in flex applications * Integral Flexfill(R) * Ozone-sunlight (UV)- and weather-resistant *ULListed and CSA Certified for indoor and outdoor use * Water-resistant, sunlight (UV)- resistant * Safety-colored * High heat and flame resistance * Resistant to oils, acids and chemicals * Excellent abrasion and cut resistance Industry Approvals: * UL Flexible Cord - ULSubject 62 * CSA Flexible Cord - C22.2-49 * MSHA Approved * RoHS Compliant Packaging: *250' (76.2 m), 500' (152.4 m), 1000' (304.8 m) *Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS COLOR 2 3 4 5 Black, White Black, White, Green Black, White, Red, Green Black, White, Red, Orange, Green 10 Rubber Cord Cord & Cordset Carolprene(R) Jacketed Type SOOW/SJOOW 90C 600 Volt UL /CSA Portable Cord Product Construction: Conductors: *18 through 10 AWG fully annealed stranded bare copper per ASTM B-174 Insulation: *Premium-grade, color-coded 90C EPDM *Color code: See chart below Jacket: *Yellow *Temperature range: -40C to +90C Jacket Marking: *CAROL (SIZE) 90C (UL) WATERRESISTANT SOOW/SJOOW CSA (-40C) FT-2 P-7K-123033 MSHA -- MADE IN USA 600 VOLT Applications: * Portable tools and equipment * Portable appliances * Small motors and associated machinery *Food processing plants and equipment *Marinas/docks * Shipyards * OEM/MRO * OSHA VPP safety *Construction site power *Industrial plants *Mining Features: * Excellent resistance to oil and moisture *Good tensile strength, elongation and aging characteristics *High flexibility * Excellent abrasion resistance * Water-resistant *UL Listed and CSA certified for indoor and outdoor use *Ozone-sunlight (UV)- and weather-resistant YELLOW HIGH-VISIBILITY - TYPE SJOOW - 300 VOLT - 90C - UL/CSA CATALOG NO. OF AWG NUMBER COND SIZE NOMINAL INS. THICKNESS COND. STRAND INCHES mm INCHES APPROX. CURRENT NET WT. mm AMPS LBS/M' (S) NOMINAL O.D. STD. CTN. 01411 3 18 16/30 0.030 0.76 0.305 7.75 10 63 1000' 01444 4 18 16/30 0.030 0.76 0.330 8.38 7 76 250' 01442 3 16 26/30 0.030 0.76 0.330 8.38 13 76 250' 01443 4 16 26/30 0.030 0.76 0.365 9.27 10 95 250' 01460 3 14 41/30 0.030 0.76 0.370 9.40 18 106 250' 01464 4 14 41/30 0.030 0.76 0.410 10.41 15 121 250' 01480 3 12 65/30 0.030 0.76 0.430 10.92 25 146 250' 01481 4 12 65/30 0.030 0.76 0.475 12.07 20 185 250' 01483 3 10 104/30 0.045 1.14 0.580 14.73 30 242 250' 01484 4 10 104/30 0.045 1.14 0.655 16.64 25 304 250' YELLOW HIGH-VISIBILITY - TYPE SOOW - 600 VOLT - 90C - UL/CSA CATALOG NO. OF AWG NUMBER COND SIZE NOMINAL INS. THICKNESS COND. STRAND INCHES mm INCHES APPROX. CURRENT NET WT. mm AMPS LBS/M' (S) NOMINAL O.D. STD. CTN. 84 250' 02469 3 18 16/30 0.030 0.76 0.365 9.27 02470 4 18 16/30 0.030 0.76 0.390 9.91 7 101 250' Industry Approvals: 02465 3 16 26/30 0.030 0.76 0.390 9.91 13 103 250' 02466 4 16 26/30 0.030 0.76 0.420 10.67 10 119 250' 02462 3 14 41/30 0.045 1.14 0.535 13.59 18 172 250' 02468 4 14 41/30 0.045 1.14 0.575 14.61 15 208 250' 02425 3 12 65/30 0.045 1.14 0.595 15.11 25 229 250' 02426 4 12 65/30 0.045 1.14 0.650 16.51 20 280 250' 02428 3 10 104/30 0.045 1.14 0.660 16.76 30 295 250' 02427 4 10 104/30 0.045 1.14 0.715 18.16 25 353 250' * UL Flexible Cord * CSA Flexible Cord * MSHA Approved * RoHS Compliant Packaging: *250' (76.2 m), 1000' (304.8 m) *Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS 3 4 11 COLOR Black, White, Green Black, White, Red, Green Cord furnished with UL and CSA labels Green conductor for grounding only. (S) Actual shipping weight may vary. 10 Rubber Cord Cord & Cordset Carolprene(R) Jacketed Type SOOW 90C 600 Volt UL /CSA Portable Cord Product Construction: Conductors: *18 through 2 AWG fully annealed stranded bare copper per ASTM B-174 Insulation: *Premium-grade, color-coded 90C EPDM *Color code: See chart below Jacket: *Carolprene(R), black *Temperature range: -40C to +90C TYPE SOOW - 600 VOLT - UL/CSA NOMINAL INS. THICKNESS AWG COND. SIZE STRAND INCHES mm CATALOG NUMBER NO. OF COND. 02763 2 18 16/30 0.030 02769 3 18 16/30 0.030 02770 4 18 16/30 02722 2 16 02765 3 02766 4 02723 02762 NOMINAL O.D. APPROX. CURRENT NET WT. AMPS LBS/M' (S) STD. CTN. Jacket Marking: *CAROL (SIZE) (mm2) 90C (UL) WATER RESISTANT SOOW CSA (-40C) FT-2 P-7K-123033 MSHA 600 VOLT RoHS MADE IN USA INCHES mm 0.76 0.345 8.76 10 72 250' 0.76 0.365 9.27 10 84 250' 0.030 0.76 0.390 9.91 7 101 250' 26/30 0.030 0.76 0.370 9.40 13 83 250' * Portable tools and equipment * Portable appliances * Small motors and associated machinery 16 26/30 0.030 0.76 0.390 9.91 13 103 250' Features: 16 26/30 0.030 0.76 0.420 10.67 10 119 250' 2 14 41/30 0.045 1.14 0.510 12.95 18 158 250' 3 14 41/30 0.045 1.14 0.535 13.59 18 172 250' 02768 4 14 41/30 0.045 1.14 0.575 14.61 15 208 250' 02724 2 12 65/30 0.045 1.14 0.570 14.48 25 195 250' 02725 * Excellent resistance to oil and moisture *Good tensile strength, elongation and aging characteristics *High flexibility * Excellent abrasion resistance * Water-resistant *UL Listed and CSA certified for indoor and outdoor use *Ozone-sunlight (UV)- and weather-resistant 3 12 65/30 0.045 1.14 0.595 15.11 25 229 250' 02726 Industry Approvals: 4 12 65/30 0.045 1.14 0.650 16.51 20 280 250' 02767 2 10 104/30 0.045 1.14 0.620 15.75 30 235 250' 02728 3 10 104/30 0.045 1.14 0.660 16.76 30 295 250' 02727 4 10 104/30 0.045 1.14 0.715 18.16 25 353 250' 16063 3 8 133/29 0.060 1.52 0.845 21.46 40 525 250' 16064 4 8 133/29 0.060 1.52 0.960 24.38 35 676 250' 16065 5 8 133/29 0.060 1.52 1.075 27.31 28 795 250' 16073 3 6 133/27 0.060 1.52 0.980 24.89 55 703 250' 16074 4 6 133/27 0.060 1.52 1.080 27.43 45 891 250' 16075 5 6 133/27 0.060 1.52 1.200 30.48 36 1123 250' 16083 3 4 133/25 0.060 1.52 1.140 28.96 70 1022 250' 16084 4 4 133/25 0.060 1.52 1.260 32.00 60 1336 250' 16085 5 4 133/25 0.060 1.52 1.365 34.67 48 1587 250' 16093 3 2 133/23 0.060 1.52 1.330 33.78 95 1484 250' 16094 4 2 133/23 0.060 1.52 1.460 37.08 80 1869 250' 16095* 5 2 133/23 0.060 1.52 1.580 40.13 64 2240 250' Applications: * UL Flexible Cord - Subject 62 * CSA Flexible Cord - C22.2-49 * MSHA Approved * RoHS Compliant Packaging: *250' (76.2 m), 500' (152.4 m), 1000' (304.8 m) *Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS 2 3 4 5 COLOR Black, White Black, White, Green Black, White, Red, Green Black, White, Red, Orange, Green Cord furnished with UL and CSA labels. * Non-stock item; minimum quantity purchase required. G reen conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. 12 Rubber Cord Cord & Cordset Carolprene(R) Jacketed Type SJOOW 90C 300 Volt UL /CSA Portable Cord Product Construction: Conductors: *18 through 10 AWG fully annealed stranded bare copper per ASTM B-174 Insulation: *Premium-grade, color-coded 90C EPDM *Color code: See chart below Jacket: *Carolprene(R), black *Temperature range: -40C to +90C Jacket Marking: *CAROL (SIZE) (mm2) 90C (UL) WATER RESISTANT SJOOW CSA (-40C) FT-2 P-7K-123033 MSHA 300 VOLT RoHS MADE IN USA TYPE SJOOW - 300 VOLT - UL/CSA CATALOG NUMBER NO. OF AWG COND. COND. SIZE STRAND NOMINAL INS. THICKNESS NOMINAL O.D. INCHES mm INCHES mm APPROX. CURRENT NET WT. AMPS LBS/M' (S) STD. CTN. 01310 2 18 16/30 0.030 0.76 0.285 7.24 10 51 1000' 01311 3 18 16/30 0.030 0.76 0.305 7.75 10 63 1000' Applications: 01344 4 18 16/30 0.030 0.76 0.330 8.38 7 76 250' * Portable tools and equipment * Portable appliances * Small motors and associated machinery 01312 2 16 26/30 0.030 0.76 0.310 7.87 13 60 1000' Features: 01342 3 16 26/30 0.030 0.76 0.330 8.38 13 76 250' 01343 4 16 26/30 0.030 0.76 0.365 9.27 10 95 250' 01358 2 14 41/30 0.030 0.76 0.340 8.64 18 79 250' 01360 3 14 41/30 0.030 0.76 0.370 9.40 18 106 250' 01364 4 14 41/30 0.030 0.76 0.410 10.41 15 121 250' 01379 2 12 65/30 0.030 0.76 0.410 10.41 25 117 250' 01380 3 12 65/30 0.030 0.76 0.430 10.92 25 146 250' 01381 4 12 65/30 0.030 0.76 0.475 12.07 20 185 250' 01382* 2 10 104/30 0.045 1.14 0.560 14.22 30 210 250' 01383 3 10 104/30 0.045 1.14 0.580 14.73 30 242 250' 01384 4 10 104/30 0.045 1.14 0.655 16.64 25 304 250' * Excellent resistance to oil and moisture *Good tensile strength, elongation and aging characteristics *High flexibility * Excellent abrasion resistance * Water-resistant *UL Listed and CSA Certified for indoor and outdoor use *Ozone-sunlight (UV)- and weather-resistant Industry Approvals: * UL Flexible Cord - UL Subject 62 * CSA Flexible Cord - C22.2-49 * MSHA Approved * RoHS Compliant Packaging: *250' (76.2 m), 500' (152.4 m), 1000' (304.8 m) *Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS 2 3 4 13 COLOR Black, White Black, White, Green Black, White, Red, Green Cord furnished with UL and CSA labels. * Non-stock item; minimum quantity purchase required. Green conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. Plastic Cord Cord & Cordset Type SJT 60C 300 Volt UL/CSA Portable Cord Product Construction: Conductors: *18 through 12 AWG annealed stranded bare copper per ASTM B-174 Insulation: *Premium-grade, color-coded PVC *Color code: See chart below Jacket: TYPE SJT -- 300 VOLT -- UL *Polyvinylchloride (PVC) 18 and 16 AWG - black only 14 and 12 AWG - orange only *Temperature range: -20C to +60C CATALOG NUMBER NO. OF COND. AWG SIZE COND. STRAND NOMINAL INS. THICKNESS NOMINAL O.D. INCHES mm INCHES mm Jacket Marking: 86012* 2 18 16/30 0.030 0.76 0.285 7.24 10 45 1000' 86013 3 18 16/30 0.030 0.76 0.305 7.75 10 55 1000' 86022 2 16 26/30 0.030 0.76 0.315 8.00 13 50 1000' 86023 3 16 26/30 0.030 0.76 0.335 8.51 13 70 250' 86333 3 14 41/30 0.030 0.76 0.365 9.27 18 85 250' 86343 3 12 65/30 0.030 0.76 0.440 11.18 25 130 250' *(SIZE) (mm2) 60C SJT E# (UL) --- CSA LL# FT-2 RoHS MADE IN USA 300V Applications: * Portable tools * Motors * Portable lights * Lamps Features: * Non-stock item; minimum quantity purchase required. Green conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. *Resists: * Acids * Alkalies * Ozone Industry Approvals: * UL Listed * RoHS Compliant Packaging: *250' (76.2 m) *Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS 23 COLOR 2 Black, White 3 Black, White, Green APPROX. CURRENT NET WEIGHT AMPS LBS/M'(S) STD. CTN. Cord & Cordset Industrial Cord NOW RED A STO ITEM CK Carolprene(R) Welding Cable 90C 600 Volt Product Construction: Conductor: *6 AWG through 500 kcmil fully annealed stranded bare copper Class K Jacket: * Premium-grade 90C EPDM, black or red *Temperature range: -40C to +90C CAROLPRENE(R) WELDING CABLE - 600 VOLT - CLASS K - 30 AWG STRANDING CATALOG NUMBER AWG OR kcmil CONDUCTOR STRAND NOMINAL O.D. INCHES mm APPROX. NET WT. LBS/M'(S) STD. CTN. Jacket Marking: *CAROLPRENE (SIZE) WELDING CABLE 600 VOLT MADE IN USA Applications: *Secondary voltage resistance welding leads *Power supply applications not exceeding 600 volts AC 01778 6 259/30 0.380 9.65 135 250' 01777 4 374/30 0.400 10.16 172 250' 01776 2 625/30 0.465 11.81 260 250' 01775 1 778/30 0.495 12.57 317 250' 01774 1/0 990/30 0.560 14.22 400 250' 01773 2/0 1248/30 0.615 15.62 487 250' 01772 3/0 1586/30 0.670 17.02 605 250' 01771 4/0 2054/30 0.750 19.05 827 250' *250' (76.2 m), 500' (152.4 m), and 1000' (304.8 m) reels *MCM sizes cut to length *Other put-ups available on special order 99142* 250 kcmil 2496/30 0.830 21.08 976 250' Industry Approvals: 99432* 350 kcmil 3432/30 0.960 24.38 1338 250' * RoHS Compliant 99202* 500 kcmil 5054/30 1.200 30.48 1995 250' Features: * Good flexibility *Abrasion-resistant *Good color retention Packaging: (S) Actual shipping weight may vary. *Non-stock item, minimum quantity required. WELDING CABLE AMPACITIES SINGLE CONDUCTOR Required Cable Sizes: For Welding Cable Application AMPS 100 150 200 250 300 350 400 450 500 550 600 length in feet for total circuit for secondary voltages only - do not use this table for 600 Volt in-line applications 100' 150' 200' 250' 300' 350' 400' 4 4 2 2 1 1/0 1/0 4 2 1 1/0 2/0 3/0 3/0 2 1 1/0 2/0 3/0 4/0 4/0 1 1/0 2/0 3/0 4/0 1/0 2/0 3/0 4/0 1/0 3/0 4/0 2/0 3/0 2/0 4/0 3/0 4/0 3/0 4/0 4/0 REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS Suggested Ampacities: For 600 Volt In-Line Applications AWG OR kcmil AMPERES AWG AMPERES 500 kcmil 695 1/0 190 350 kcmil 552 1 160 250 kcmil 445 2 140 4/0 310 4 100 3/0 265 6 75 2/0 223 Ampacities for portable cable, continuous-duty (ambient temperature of 40C). May not be suitable for all installations per National Electrical Code(R). Ordering Part Number Example 01771.38.03 4/0 500' put-up in red .03 for red jacket The total circuit length includes both welding and ground leads (based on 4-volt drop) 60% duty cycle. These values for current-carrying capacity are based on a copper temperature of 60C (140F), an ambient temperature of 40C (104F) and yield load factors from approximately 32% for the No. 2 AWG cable to approximately 23% for the No. 3/0 AWG cable, and higher for the smaller sizes. The sizes of cables generally used range from No. 2 AWG to No. 3/0 AWG. In actual service, the load factor may be much higher than indicated without overheating the cable, as the ambient temperature will generally be substantially lower than 40C. 34 Specialty Cord Cord & Cordset Hook-Up Wire UL Types MTW, TFF, AWM and CSA TEW 90C 600 Volt MTW, TFF 105C 600 Volt AWM/TEW Product Construction: Conductor: *18 through 8 AWG fully annealed stranded bare copper per ASTM B-8 Insulation: *Premium-grade, color-coded PVC *Temperature range: MTW: -40C to +90C TEW/AWM: -20C to +105C *Color code: See chart below UL TYPE MTW, AWM, TFF, CSA TYPE TEW - 600 VOLT Jacket Marking: *18 and 16 AWG: CAROL (SIZE) 600V E# MTW (UL) OR TFF OR AWM VW-1 --- CSA TEW 105C FT-1 *14 through 8 AWG: CAROL (SIZE) 600V E# MTW (UL) OR AWM VW-1 --- CSA TEW 105C FT-1 Applications: * Motor and transformer lead * External wiring of machinery Features: *Outstanding oil, flame and moisture resistance *Extra-flexible * UL and NMTBA Type MTW/AWM * CSA TEW * Passes VW-1 Vertical Flame Test *OSHA Acceptable *AWM Style 1015 - 18-8 AWG *AWM Style 1335 - 18-10 AWG *AWM Style 1336 - 8 AWG *RoHS Compliant Packaging: *18 and 16 AWG: 500' (152.4 m) spools 2500' (762 m) spools *14 through 10 AWG: 500' (152.4 m) spools 2500' (762 m) reels *8 AWG: 500' (152.4 m) reels *Other put-ups available on special order COLOR CODE CHART STOCK COLORS ORDERING SUFFIX STOCK COLORS Black 01 Orange 04 White 02 Brown 08 Red 03 Purple 19 Blue 07 Gray 10 Green 06 Pink 13 Yellow 05 41 AWG SIZE 76502 18 76512 COND. STRAND ORDERING SUFFIX NOMINAL O.D. APPROX. NET WT. LBS/M'(S) INCHES mm INCHES mm STOCK COLORS 16/30 0.031 0.79 0.110 2.79 1-12 10 16 26/30 0.031 0.79 0.123 3.12 1-12 14 76812 14 19/.0147 0.031 0.79 0.136 3.45 1-12 20 76822 12 19/.0185 0.031 0.79 0.155 3.94 1-7 28 76832 10 19/.0234 0.031 0.79 0.176 4.47 1-5 42 76843 8 19/.0295 0.045 1.14 0.242 6.15 1-5 72 Actual shipping weight may vary. (S) Industry Approvals: CATALOG NUMBER NOMINAL INS. THICKNESS Specialty Cord Cord & Cordset Lamp Cord Type SPT 60C 300 Volts UL /CSA Product Construction: Conductor: *18 and 16 AWG fully annealed bare or tinned copper per ASTM B-174 Insulation: *Premium-grade, color-coded PVC *Temperature range: -20C to +60C *Color code: See chart below TYPE SPT-1 Jacket Marking: NO. CATALOG OF AWG COND. NUMBER COND. SIZE STRAND NOM. INSULATION THICKNESS INCHES mm NOMINAL O.D. INCHES mm 02301 0.030 0.107 2.72 X X 0.210 5.330 0.107 2.72 X X 0.210 5.330 0.107 2.72 X X 0.210 5.330 0.107 2.72 X X 0.210 5.330 02304 02305 02306 2 2 2 2 18 18 18 18 41/34 41/34 41/34 41/34 0.030 0.030 0.030 0.76 0.76 0.76 0.76 APPROX. CURRENT NET WEIGHT (1) AMPS LBS/M (S) JACKET COLOR CHART NOM. INSULATION THICKNESS INCHES mm NOMINAL O.D. INCHES mm 02303 0.045 0.155 (1) 2 16 65/34 1.14 3.94 X X 0.295 7.490 Applications: 10 22 A 10 22 D Industry Approvals: 10 22 C Packaging: * Small appliances *Lamps *Radios *Jukeboxes * UL Listed *CSA Certified *RoHS Compliant * 250' (76.2 m) spools *Other put-ups available on special order 10 22 B TYPE SPT-2 NO. CATALOG OF AWG COND. NUMBER COND. SIZE STRAND *(SIZE) SPT-1 (or STP-2) 60C E# (UL) --CSA LL# FT-2 300V APPROX. CURRENT NET WEIGHT (1) AMPS LBS/M (S) 13 37 JACKET COLOR CHART JACKET COLOR CODE CHART A Black or White or Brown B Clear Silver (tinned copper) C Clear Gold D Clear A Ampacities based on NEC table 400.5(A). Actual shipping weight may vary. (S) 44 Specialty Cord Cord & Cordset Low-Voltage Landscape Lighting Wire 60C 150 Volts UL LOW-VOLTAGE LANDSCAPE LIGHTING WIRE - 150 VOLT - UL CATALOG NUMBER NO. OF COND. AWG SIZE LENGTH OF CORD (FEET) NOM. INS. THICKNESS COND. STRAND INCHES mm NOMINAL O.D. INCHES POWER RATING (1) mm VOLTS AMPS WATTS PKG PER CTN. APPROX. WEIGHT PER CTN. (LBS) (S) 02309.66.01 2 16 50 26/30 0.045 1.14 0.155 X 0.296 3.94 X 7.52 150 13 1950 12 27 02309.67.01 2 16 100 26/30 0.045 1.14 0.155 X 0.296 3.94 X 7.52 150 13 1950 12 44 02309.18.01 2 16 500 26/30 0.045 1.14 0.155 X 0.296 3.94 X 7.52 150 13 1950 1 19 02310.66.01 2 14 50 41/30 0.045 1.14 0.170 X 0.354 4.32 X 8.99 150 18 2700 8 25 02310.67.01 2 14 100 41/30 0.045 1.14 0.170 X 0.354 4.32 X 8.99 150 18 2700 8 45 02310.18.01 2 14 500 41/30 0.045 1.14 0.170 X 0.354 4.32 X 8.99 150 18 2700 1 37 02311.18.01 2 12 500 65/30 0.045 1.14 0.190 X 0.385 4.83 X 9.78 150 25 3750 1 58 02311.66.01 2 12 50 65/30 0.045 1.14 0.190 X 0.385 4.83 X 9.78 150 25 3750 8 30 02311.67.01 2 12 100 65/30 0.045 1.14 0.190 X 0.385 4.83 X 9.78 150 25 3750 8 59 02312.38.01 2 10 500 19/.0234 0.045 1.14 0.400 X 0.200 10.16 X 5.08 150 30 4500 1 52 02313.38.01 2 8 500 19/.0295 0.060 1.52 0.270 X 0.550 6.86 X 13.97 150 55 8250 1 165 Amps and watts are offered ONLY as a guide to the end user. (S) Actual shipping weight may vary. (1) Product Construction: Conductor: *8 through 16 AWG fully annealed stranded bare copper per ASTM B-3 Insulation: *Premium-grade PVC, black *Duplex parallel design for easy tear-down during installation *Polarity ridge on one leg for positive circuit identification *Temperature range: -20C to +60C 45 Jacket Marking: Industry Approvals: *CAROL (SIZE) UNDERGROUND LOW ENERGY CIRCUIT CABLE SUNLIGHT RESISTANT FOR LOW VOLTAGE OUTDOOR LIGHTING E# (UL) -- CSA LL# LVLL 30V FT1 *UL Listed underground low-energy circuit cable *UL Listed for outdoor applications *UL Listed for direct-burial applications *CSA approved *RoHS Compliant Applications: * Low-voltage landscape lighting *Low-voltage security lighting Packaging: *Both 50' and 100' lengths are packaged in a sleeve *500' (513.4 m) spools *Other put-ups available on special order Specialty Cord Cord & Cordset Low-Voltage Sprinkler Wire 60C 30 Volts UL LOW-VOLTAGE SPRINKLER WIRE - 30 VOLT - UL LENGTH OF CORD (FEET) POWER RATING (1) CATALOG NUMBER NO. OF COND. AWG SIZE 23824.60.01 4 18 23804.18.01 4 18 23815.60.01 5 18 23825.60.01 5 18 23805.18.01 5 18 500 Spool 23817.60.01 7 18 50 Cuff 23827.60.01 7 18 100 Cuff 23807.18.01 7 18 500 Spool 23810.18.01 10 18 500 Reel APPROX. WEIGHT PER CTN. (LBS) (S) PACKAGE TYPE VOLTS AMPS WATTS PKG PER CTN. 100 Cuff 30 5.6 168 6 22 500 Spool 30 5.6 168 1 18 50 Cuff 30 5.6 168 6 13 100 Cuff 30 5.6 168 6 27 30 5.6 168 1 22 30 4.9 147 6 18 30 4.9 147 6 36 30 4.9 147 1 31 30 3.5 165 1 44 Amps and watts are offered ONLY as a guide to the end user. (S) Actual shipping weight may vary. (1) Product Construction: Conductor: Jacket Marking: Industry Approvals: *18 AWG fully annealed solid bare copper per ASTM B-3 *CAROL (SIZE) 30V SPRINKLER SYSTEMS WIRE - DIRECT BURIAL E54567 (UL) Insulation: Applications: *Low-voltage golf course satellite sprinkler control *Residential sprinkler solenoid control *UL Listed under a UL Miscellaneous Wire file *ULListed for outdoors applications *UL Listed for direct burial applications *RoHS Compliant *Premium-grade, color-coded PVC *Premium-grade PE jacket, black *Nylon rip cord to facilitate jacket removal *Temperature range: -20C to +60C *Color code: See chart below Packaging: *See tabular data above *Other put-ups available on special order COLOR CODE CHART 1 Black 2 White 3 Red 4 Green 7 Blue 10 Purple 5 Orange 8 Brown 6 Yellow 9 Gray 46 Cord & Cordset Outdoor Extension Cords 6 Index General Cable, under the Carol(R) Brand name, offers a complete line of high-quality Outdoor Extension Cords designed to provide the best electrical performance for your application. Lifetime Plus(R) Super Flex(R) extension cords have a connector end that lights up to indicate the power is on. Twice as flexible as other extension cords, the high- visibility yellow cord resists moisture and will not crack in arctic cold or melt Carol's FrogHide(R) Ultra Flex(R) in desert heat. The super-tough extension cords are the most jacket provides extra resistance flexible, durable rubber outdoor to cracking and abrasion. cords on the market with a Lifetime Plus extension cords name you won't forget. FrogHide remain flexible to -50C. cords are molecularly bonded to the caps and connectors, with The Carol line of All Weather heavy-duty strain reliefs built extension cords and High in for lasting strength, even in Visibility All Weather extension rough applications. Plus, they cords are designed for excellent are resistant to water, oil, ozone performance, even in freezing and chemicals. FrogHide cords temperatures. These blue feature an exclusive personal outdoor cords remain flexible identification system, so you can to -50C. claim them as your own. They Safety Orange(R) generalare easy to spot on the job, thanks to the bold, bright green purpose outdoor extension (R) color. FrogHide extension cords cords and Powr-Centers are basic necessities for every come with a limited lifetime household tool box. The familiar warranty. orange jacket provides excellent visibility for improved safety on the job. 47 Page FrogHide(R) Ultra Flex(R) Extension Cords 48 Lifetime Plus(R) Super Flex(R) Lighted Extension Cords 49 Safety Orange(R) Extension Cords 50 Outdoor Powr-Center(R) Extension Cords 51 All Weather Extension Cords 52 High Visibility All Weather Extension Cords 52 Outdoor Extension Cords Cord & Cordset FrogHide(R) Ultra Flex(R) Extension Cords 3-Conductor Grounded * Type SJOW * -40C to 90C * 300 Volts CATALOG NUMBER LENGTH COLOR NO. OF AWG OF CORD OF COND. SIZE (FT) JACKET PKG. WT./ WT./ PER UNIT CTN. WATTS CTN. LBS LBS POWER RATING VOLTS AMPS UPC CODE 06425.63.06 3 14 25 Green 125 15 1875 10 3.0 30 079407064250 06450.63.06 3 14 50 Green 125 15 1875 6 6.0 36 079407064502 06400.63.06 3 14 100 Green 125 13 1625 4 11.4 46 079407064007 06225.61.06 3 12 25 Green 125 15 1875 6 4.3 26 079407062256 06250.61.06 3 12 50 Green 125 15 1875 4 7.9 32 079407062508 06200.61.06 3 12 100 Green 125 15 1875 2 15.9 32 079407062003 Product Description: Carol(R) Brand FrogHide(R) Ultra Flex(R) extension cords are the most flexible, durable rubber outdoor cords on the market with a name you won't forget. FrogHide cords are molecularly bonded to the caps and connectors with heavy-duty strain reliefs built-in for lasting strength, even in rough applications. Plus, they are resistant to water, oil, ozone and chemicals. FrogHide cords feature an exclusive personal identification system, so you can claim them as your own. They are easy to spot on the job, thanks to the bold, bright green color. FrogHide extension cords come with a limited lifetime warranty. Product Warranty: Carol(R) Brand FrogHide(R) Ultra Flex(R) Limited Lifetime Warranty This product is covered by a limited lifetime warranty against manufacturing defects. If you are not satisfied with this cord, return it with the original packaging to General Cable, 4 Tesseneer Drive, Highland Heights, KY 41076 for evaluation. This warranty does not cover damage to the cord from long-term use, abuse or from failure to follow electrical codes, laws and regulations relating to building or construction, including Article 305 of the National Electrical Code(R). This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. Product Construction: Conductor: * 14 AWG or 12 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded 90C EPDM Jacket: * CPE; green * Temperature range: -40C to 90C * Voltage rating: 300 volts NEMA Configuration: * 5-15P/5-15R Applications: * Chain saws * Wet/dry vacs * Orbital sanders * Other outdoor equipment Features: * New technology molecularly bonds cap and connector * Ultra-flexible * Heavy-duty strain relief * Personal identification system * Resistant to water, oil, ozone and chemicals * Limited lifetime warranty * 3-conductor grounded Industry Approvals: * UL Listed * OSHA Acceptable 48 Outdoor Extension Cords Cord & Cordset Lifetime Plus(R) Super Flex(R) Lighted Extension Cords 3-Conductor Grounded * Type SJTW * -50C to 60C * 300 Volts CATALOG NUMBER LENGTH COLOR NO. OF AWG OF CORD OF COND. SIZE (FT) JACKET VOLTS AMPS UPC CODE 03387.63.05 3 16 25 Yellow 125 13 1625 12 1.7 20 079407033874 03390.63.05 3 14 25 Yellow 125 15 1875 12 2.5 30 079407033904 03391.63.05 3 14 50 Yellow 125 15 1875 6 4.7 28 079407033911 03392.63.05 3 14 100 Yellow 125 13 1625 4 9.2 37 079407033928 03397.61.05 3 12 25 Yellow 125 15 1875 6 3.7 22 079407033973 03398.61.05 3 12 50 Yellow 125 15 1875 4 7.0 28 079407033980 03399.61.05 3 12 100 Yellow 125 15 1875 2 13.1 26 079407033997 Product Description: Lifetime Plus(R) Super Flex(R) extension cords have a connector end that lights up to indicate the power is on. Twice as flexible as other extension cords, the high-visibility yellow cord resists moisture and will not crack in arctic cold or melt in desert heat. The super-tough jacket provides extra resistance to cracking and abrasion. The Lifetime Plus extension cords have a limited lifetime warranty and remain flexible to -50C. Product Construction: Conductor: * 16 AWG, 14 AWG or 12 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded PVC Jacket: * PVC; yellow * Temperature range: -50C to 60C * Voltage rating: 300 volts NEMA Configuration: * 5-15P/5-15R 49 PKG. WT./ WT./ PER UNIT CTN. WATTS CTN. LBS LBS POWER RATING Applications: * Chain saws * Wet/dry vacs * Orbital sanders * Other outdoor equipment Features: * Lights up with power * Super-flexible * Weather- and water-resistant * Limited lifetime warranty * 3-conductor grounded Industry Approvals: * UL Listed * OSHA Acceptable Outdoor Extension Cords Cord & Cordset Safety Orange(R) Extension Cords 3-Conductor Grounded * Type SJTW * -40C to 60C * 300 Volts LENGTH AWG OF CORD SIZE (FT) COLOR OF JACKET WT./ CTN. LBS VOLTS AMPS UPC CODE 3 16 10 Orange 125 13 1625 24 0.8 19 079407033188 03327.63.04 3 16 25 Orange 125 13 1625 24 1.8 43 079407033270 03354.63.04 3 16 50 Orange 125 13 1625 12 3.4 40 079407033546 03302.63.04 3 16 100 Orange 125 10 1250 4 6.6 26 079407033027 03328.63.04 3 14 25 Orange 125 15 1875 6 2.4 14 079407033287 03356.63.04 3 14 50 Orange 125 15 1875 4 4.6 18 079407033560 03304.63.04 3 14 100 Orange 125 13 1625 2 9.0 18 079407033041 06826.63.04 3 12 25 Orange 125 15 1875 4 3.4 14 079407068265 06853.63.04 3 12 50 Orange 125 15 1875 2 6.6 13 079407068531 06801.63.04 3 12 100 Orange 125 15 1875 2 13.0 26 079407068012 CATALOG NUMBER NO. OF COND. 03318.63.04 Product Construction: Conductor: * 16 AWG through 12 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded PVC PKG. WT./ PER UNIT WATTS CTN. LBS POWER RATING Applications: * General use indoor/outdoor cord * Vacuum cleaners * Floor polishers * Sanders * Other power equipment Features: * Indoor/outdoor use * 3-conductor grounded Industry Approvals: * UL Listed * OSHA Acceptable Jacket: * PVC; orange * Temperature range: -40C to 60C * Voltage rating: 300 volts NEMA Configuration: * 5-15P/5-15R 50 Outdoor Extension Cords Cord & Cordset Outdoor Powr-Center(R) Extension Cords 3-Conductor Grounded * Type STW, SJEOOW and SJTW * -40C to 60C * 300 and 600 Volts CATALOG NUMBER LENGTH COLOR NO. OF AWG OF CORD OF COND. SIZE (FT) JACKET PKG. WT./ WT./ PER UNIT CTN. WATTS CTN. LBS LBS POWER RATING VOLTS AMPS UPC CODE STW-600V 00594.63.04 3 12 2 Orange 125 15 1875 6 1.0 6 079407005949 00596.61.04 3 12 50 Orange 125 15 1875 2 11.1 22 079407005963 00597.61.04 3 12 100 Orange 125 15 1875 2 21.7 43 079407005970 SJTW-300V 00690.63.04 3 14 10 Orange 125 15 1875 12 1.2 15 079407006908 00691.63.04 3 14 25 Orange 125 15 1875 6 2.6 16 079407006915 00692.63.04 3 14 50 Orange 125 15 1875 4 4.7 19 079407006922 00694.63.04 3 12 10 Orange 125 15 1875 12 1.8 22 079407006946 00696.63.04 3 12 50 Orange 125 15 1875 2 7.0 14 079407006960 00697.63.04 3 12 100 Orange 125 15 1875 2 13.4 27 079407006977 SJEOOW-300V 00790.63.07 3 14 10 Blue 125 15 1875 12 1.3 16 079407007905 00791.63.07 3 14 25 Blue 125 15 1875 6 2.7 16 079407007912 00792.63.07 3 14 50 Blue 125 15 1875 4 4.8 19 079407007929 00793.63.07 3 14 100 Blue 125 13 1625 2 9.0 18 079407007936 00787.63.05 3 12 50 Yellow 125 15 1875 2 6.5 13 079407007875 00788.63.05 3 12 100 Yellow 125 15 1875 2 13.0 26 079407007882 Product Construction: Conductor: * 14 AWG or 12 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color coded PVC Jacket: * PVC; orange, TPE; blue or yellow * Temperature range: -40C to 60C * Voltage rating: 300 and 600 volts NEMA Configuration: * 5-15P/5-15R 51 Applications: * General use indoor/outdoor cord * Chain saws * Wet/dry vacs * Orbital sanders * Other power equipment Features: * Indoor/outdoor use * 3 grounded outlets Industry Approvals: * UL Listed * OSHA Acceptable Outdoor Extension Cords Cord & Cordset All Weather Extension Cords 3-Conductor Grounded * Type SJEOOW * -50C to 105C * 300 Volts CATALOG NUMBER LENGTH COLOR NO. OF AWG OF CORD OF COND. SIZE (FT) JACKET PKG. PER WATTS CTN. POWER RATING VOLTS AMPS WT./ UNIT LBS WT./ CTN. LBS UPC CODE 03654.63.07 3 16 25 Blue 125 13 1625 4 1.8 7 079407036547 03655.63.07 3 16 50 Blue 125 13 1625 4 3.2 13 079407036554 03660.63.07 3 14 25 Blue 125 15 1875 4 2.2 9 079407036608 03661.63.07 3 14 50 Blue 125 15 1875 4 4.3 17 079407036615 03662.63.07 3 14 100 Blue 125 13 1625 2 8.0 16 079407036622 03667.63.07 3 12 50 Blue 125 15 1875 2 6.5 13 079407036677 03668.63.07 3 12 100 Blue 125 15 1875 2 12.5 25 079407036684 Product Description: Features: Jacket: The Carol(R) line of All Weather Extension Cords are designed for excellent performance, even in freezing temperatures. The blue outdoor cords remain flexible and resist cracking to -50C. * TPE; blue * Temperature range: -50C to 105C * Voltage rating: 300 volts Product Construction: * 5-15P/5-15R * Flexible from -50C to 105C * For harsh weather conditions * 3-conductor grounded NEMA Configuration: Industry Approvals: * UL Listed * OSHA Acceptable Applications: Conductor: * Snow blowers * Engine heaters * Battery chargers * Other outdoor equipment * 16 AWG through 12 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded PVC High Visibility All Weather Extension Cords 3-Conductor Grounded * Type SJEOOW * -50C to 105C * 300 Volts CATALOG NUMBER LENGTH COLOR NO. OF AWG OF CORD OF COND. SIZE (FT) JACKET PKG. PER WATTS CTN. WT./ UNIT LBS WT./ CTN. LBS UPC CODE POWER RATING VOLTS AMPS 03685.61.05 3 10 50 Yellow 125 15 1875 2 12.5 25 079407036851 03686.61.05 3 10 100 Yellow 125 15 1875 2 24.5 49 079407036868 Product Construction: Conductor: * 10 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded premium PVC Jacket: * TPE; yellow * Temperature range: -50C to 105C * Voltage rating: 300 volts NEMA Configuration: * 5-15P/5-15R Applications: * Heavy construction equipment * Air compressors * Circular saws * Generators Industry Approvals: * ULListed * OSHA Acceptable 52 Cord & Cordset Application-Specific Extension Cords 7 Index Pro Flex(R) Rubber Extension Cords 54 Coiled Power Tool Extension Cords and Power Supply Cords 54 Power Supply Replacement Cords General Cable offers a complete line of Power Supply Replacement Cords for use with power tools and household appliances. The three-conductor cords have either right angle or straight caps with a variety of plug configurations. The free ends are conveniently slit for ease of connection. Carol(R) Brand Range Cords and Dryer Cords are available in three-wire and four-wire constructions, with an assortment of plug configurations.They are designed to accommodate virtually any household oven/ range or clothes dryer. 53 Carol offers a wide assortment of Major Appliance Extension Cords with a variety of plug and cap configurations for use with air conditioners, refrigerators, freezers, microwave ovens, dehumidifiers and other large household appliances. Page 54-55, 57 Range Cords 56 Dryer Cords 56 Air Conditioner Replacement Cords 56 Major Appliance Cords 57 Application-Specific Extension Cords Cord & Cordset Pro Flex(R) Rubber Extension Cords 3-Conductor Grounded * Type SJ * 60C * 300 Volts CATALOG NUMBER 06610.63.01 06625.63.01 06911.63.01 NO. LENGTH COLOR OF AWG OF CORD OF COND. SIZE (FT) JACKET POWER RATING PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS VOLTS AMPS WATTS NEMA CONFIG. 5-15P/5-15R 24 3 16 10 Black 125 13 1625 3 16 25 Black 125 13 1625 5-15P/5-15R 3 14 25 Black 125 15 1875 5-15P/5-15R Product Construction: * 16 AWG through 14 AWG stranded bare copper per ASTM B-174 Insulation: 0.7 17 079407066100 24 1.7 40 079407066254 6 2.3 14 079407069118 Features: Jacket: * CPE; black * Temperature: 60C * Voltage rating: 300 volts Conductor: * General use indoor cord * 3-conductor grounded Industry Approvals: Applications: * UL Listed * OSHA Acceptable for indoor use * Floor polishers * Sanders * Premium-grade, color-coded EPDM UPC CODE Coiled Power Tool Extension Cords and Power Supply Cords 2 and 3 Conductor * Type SJT * 60C * 300 Volts CATALOG NUMBER 06014.60.04 02551.70.01 NO. LENGTH COLOR OF AWG OF CORD OF COND. SIZE (FT) JACKET POWER RATING VOLTS AMPS WATTS NEMA CONFIG. PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS UPC CODE 3 16 10 Orange 125 13 1625 5-15P/5-15R 10 1.1 11 079407060146 3 16 12 Black 125 15 1875 5-15P 10 1.1 11 079407025510 Product Construction: Applications: Features (cont'd.): * Workshop and tool bench use Conductor: * 16 AWG stranded bare copper per ASTM B-174 Features: * Coiled cord expands from 3' to 10' or 12' * Right-angle plug helps prevent the cord from being pulled from the socket Insulation: * Premium-grade, color-coded PVC Jacket: * PVC; orange or black * Voltage rating: 300 volts * 06014.60.04 and 02551.70.01 are 3-conductor grounded Industry Approvals: * UL Listed * OSHA Acceptable Power Supply Replacement Cords with Switch 3-Conductor Grounded * Type SJ * 60C * 300 Volts CATALOG NUMBER 02332.70.01 02333.70.01 NO. LENGTH COLOR OF AWG OF CORD OF COND. SIZE (FT) JACKET VOLTS AMPS WATTS NEMA CONFIG. SWITCH SPEED PKG. PER CTN. WT./ UNIT LBS WT./ CTN. LBS UPC CODE 3 16 10 Black 125 10 1250 5-15P 1 Speed (On/Off) 25 0.9 22 079407023325 4 16 10 Black 125 10 1250 5-15P 2 Speed (On/High/Low) 25 0.9 22 079407023332 Product Construction: Conductor: * 16 AWG stranded bare copper per ASTM B-174 Insulation: POWER RATING * Premium-grade, color-coded EPDM Jacket: * CPE; black Applications: * For replacement use * For fan replacements Features: * Switch * Straight plug * Conductor stripped 5/8" * Jacket removed 2" Industry Approvals: * UL Listed * CSA 54 Application-Specific Extension Cords Cord & Cordset Power Supply Replacement Cords 3-Conductor Grounded * Type SJ, SJOW and SJOOW * 60C * 300 Volts CATALOG NUMBER CORD TYPE NO. LENGTH COLOR POWER RATING OF AWG OF CORD OF COND. SIZE (FT) JACKET VOLTS AMPS WATTS 02685.70.01 SJOOW 02686.70.01 SJOW SJ 04932.70.01 SJ 04929.70.01 SJ 04926.70.01 NEMA CONFIG. PLUG CONFIG. PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS UPC CODE 3 18 8 Black 125 10 1250 5-15P Straight 25 0.6 14 079407026852 3 16 8 Black 125 13 1625 5-15P Straight 35 0.7 24 079407026869 3 16 12 Black 125 13 1625 5-15P Straight 50 0.8 40 079407049325 3 16 9 Black 125 13 1625 5-15P Straight 50 0.6 30 079407049295 3 16 6 Black 125 13 1625 5-15P Straight 50 0.6 28 079407049264 Product Construction: Features: Jacket: * CPE; black Conductor: * For replacement use * Straight plug Applications: * 18 AWG or 16 AWG stranded bare copper per ASTM B-174 Industry Approvals: * For replacement use * UL Listed * CSA Insulation: * Premium-grade, color-coded EPDM Power Supply Replacement Cords 2 and 3 Conductor * Type SJT and ST * 60C * 300 Volts and 600 Volts CATALOG NUMBER 300 Volt 02523.73.01 01364.70.01 02052.70.01 02524.73.01 02547.70.01 01513.70.01 04949.60.10 01614.70.01 01278.70.01 01950.70.01 600 Volt 01951.70.01 NO. LENGTH COLOR PKG. WT./ WT./ POWER RATING CORD OF AWG OF CORD OF NEMA PLUG PER UNIT CTN. TYPE COND. SIZE (FT) JACKET VOLTS AMPS WATTS CONFIG. CONFIG. CTN. LBS LBS UPC CODE SJT SJT SJT SJT SJT SJT SJT SJT SJT SJT 3 3 3 3 3 3 3 3 2 3 18 18 18 16 16 16 16 16 16 14 3 8'2" 12 3 6 8'2" 9 12 8 8 Black Black Black Black Black Black Gray Black Black Black 125 125 125 125 125 125 125 125 125 125 10 10 10 13 13 13 13 13 13 15 1250 1250 1250 1625 1625 1625 1625 1625 1625 1875 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P 1-15P 5-15P Straight Straight Straight Straight Straight Straight Straight Straight Straight Straight 50 50 50 50 25 45 50 50 30 50 0.2 0.5 0.7 0.3 0.5 0.7 0.7 0.9 0.5 0.8 12 25 36 14 13 32 35 44 14 41 079407025237 079407213641 079407020522 079407025244 079407018444 079407315130 079407049493 079407016143 079407012787 079407019502 ST 3 12 8 Black 125 15 1875 5-15P Straight 25 1.8 45 079407719518 NO. LENGTH COLOR POWER RATING CORD OF AWG OF CORD OF NEMA PLUG SWITCH PKG. PER WT./UNIT WT./CTN. UPC With Switch TYPE COND. SIZE (FT) JACKET VOLTS AMPS WATTS CONFIG. CONFIG. SPEED CTN. LBS LBS CODE 8 Black 125 10 1250 5-15P Straight 1 Speed (On/Off) 25 0.7 18 079407017324 01732.70.01 SJT 3 18 12 Black 125 10 1250 5-15P Straight 1 Speed (On/Off) 15 0.8 12 079407020539 02053.70.01 SJT 3 18 NO. LENGTH COLOR POWER RATING With Strain CORD OF AWG OF CORD OF NEMA PLUG STRAIN PKG. PER WT./UNIT WT./CTN. UPC Relief TYPE COND. SIZE (FT) JACKET VOLTS AMPS WATTS CONFIG. CONFIG. RELIEF CTN. LBS LBS CODE 6 Black 125 13 1625 5-15P Straight 7" From Free End 25 0.5 13 079407025480 02548.70.01 SJT 3 16 With NO. LENGTH COLOR POWER RATING Receptacle CORD OF AWG OF CORD OF NEMA RECEPTACLE TYPE COND. SIZE (FT) JACKET VOLTS AMPS WATTS CONFIG. CONFIG. Only PKG. PER CTN. 3 Black 125 13 1625 5-15R Straight 50 04530.73.01 SJT 3 16 Product Construction: Conductor: * 18 AWG through 12 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded PVC 55 Jacket: * PVC; black or gray Applications: * For replacement use WT./UNIT LBS 0.2 WT./CTN. LBS 9 UPC CODE 079407045303 Features: * Straight plug * Conductor stripped 5/8" * Jacket removed 1 1/2" Industry Approvals: * UL Listed * CSA Application-Specific Extension Cords Cord & Cordset Range Cords Type SRDT * 50 Amps * 60C * 300 Volts CATALOG NUMBER 05604.63.10 05606.63.10 00604.63.01 00606.63.01 NO. OF COND. AWG SIZE LENGTH COLOR OF CORD OF (FT) JACKET 3 2#6 & 1#8 4 3 2#6 & 1#8 6 4 2#6 & 2#8 4 2#6 & 2#8 POWER RATING PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS VOLTS AMPS WATTS NEMA CONFIG. Gray 250 50 12500 10-50P 12 1.8 22 079407056040 Gray 250 50 12500 10-50P 12 2.6 31 079407056064 4 Black 250 50 12500 14-50P 12 2.2 27 079407006045 6 Black 250 50 12500 14-50P 6 3.2 19 079407006069 Product Construction: Applications: Features: * Ranges in homes built prior to 1997 (3-conductor) * Ranges in homes built after 1997 (4-conductor) Conductor: * 8 AWG through 6 AWG stranded bare copper per ASTM B-174 Insulation: UPC CODE * Right-angle cap * Eyelet ends for safer hookups * Strain-relief clamp protects cord from damage caused by pulling or stretching * Premium-grade PVC; black or gray Industry Approvals: * UL Listed Dryer Cords Type SRDT * 30 Amps * 60C * 300 Volts CATALOG NUMBER 05654.63.10 05656.63.10 01004.63.01 01006.63.01 NO. OF COND. AWG SIZE LENGTH COLOR OF CORD OF (FT) JACKET 3 3#10 4 3 3#10 6 4 4#10 4 4#10 POWER RATING PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS VOLTS AMPS WATTS NEMA CONFIG. Gray 250 30 7500 10-30P 12 1.2 14 079407056545 Gray 250 30 7500 10-30P 12 1.5 18 079407056569 4 Black 250 30 7500 14-30P 12 1.5 18 079407010042 6 Black 250 30 7500 14-30P 6 2.1 12 079407010066 Product Construction: Applications: Features (cont'd): * Dryers in homes built prior to 1997 (3-conductor) * Dryers in homes built after 1997 (4-conductor) Conductor: * 10 AWG stranded bare copper per ASTM B-174 Insulation: * Strain-relief clamp protects cord from damage caused by pulling or stretching Industry Approvals: Features: * Premium-grade, color-coded PVC * UL Listed * Meets revised 1997 NEC requirements * Right-angle cap * Eyelet ends for safer hookups Jacket: * PVC; black or gray UPC CODE Air Conditioner Replacement Cords 3-Conductor Grounded * Type SPT-3 * 60C * 300 Volts CATALOG NUMBER 04194.60.17 04195.60.17 04199.60.17 NO. LENGTH COLOR POWER RATING OF AWG OF CORD OF COND. SIZE (FT) JACKET VOLTS AMPS WATTS 3 14 3 Beige 3 14 6 Beige 125 15 1875 3 12 6 Beige 250 20 5000 Product Construction: Conductor: * 12 AWG and 14 AWG stranded bare copper per ASTM B-174 Insulation: 125 15 1875 PLUG CONFIG. PKG. WT./ WT./ NEMA PER UNIT CTN. CONFIG. CTN. LBS LBS Straight 5-15P 24 Straight 5-15P 24 0.6 15 079407041657 Right Angle 6-20P 24 0.9 22 079407041992 Jacket: * PVC; beige Applications: * For replacement use with air conditioners 0.3 8 UPC CODE 079407041947 Features: * Conductor stripped 5/8" * Free end slit 1 1/2" Industry Approvals: * UL Listed * Premium-grade, color-coded PVC 56 Application-Specific Extension Cords Cord & Cordset Major Appliance Cords 3-Conductor Grounded * Type SPT-3 * 15 and 20 Amps * 60C * 300 Volts CATALOG NUMBER 00436.63.17 00439.63.17 00442.63.17 00762.63.17 00772.63.17 NO. LENGTH COLOR OF AWG OF CORD OF COND. SIZE (FT) JACKET POWER RATING VOLTS AMPS WATTS NEMA CONFIG. PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS UPC CODE 3 14 6 Beige 125 15 1875 5-15P/5-15R 24 0.6 15 079407004362 3 14 9 Beige 125 15 1875 5-15P/5-15R 24 0.9 21 079407004393 3 14 12 Beige 125 15 1875 5-15P/5-15R 12 1.2 14 079407004423 3 12 9 Beige 250 20 5000 6-20P/6-20R 24 1.4 34 079407007622 3 12 9 Beige 125 20 2500 5-20P/5-20R 24 1.4 34 079407007721 Product Construction: Features: * Molded right-angle plug Conductor: Industry Approvals: * 12 and 14 AWG stranded bare copper per ASTM B-174 * UL Listed Insulation: * Premium-grade PVC; beige Applications: * Air conditioners * Refrigerators * Freezers * Microwaves * Dehumidifiers Power Supply Replacement Cords 3-Conductor Grounded * Type SPT-1 and SPT-3 * 60C * 300 Volts CATALOG NUMBER 02050.70.10 02522.73.01 04106.73.10 04103.73.10 04806.73.10 04803.73.10 CORD TYPE NO. LENGTH COLOR OF AWG OF CORD OF COND. SIZE (FT) JACKET POWER RATING VOLTS AMPS WATTS NEMA CONFIG. PLUG CONFIG. PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS SPT-1 3 18 8 Gray 125 10 1250 5-15P Straight 50 0.4 21 079407020508 SPT-3 3 16 6 Black 125 13 1625 5-15P Straight 25 0.6 14 079407025220 SPT-3 3 16 6 Gray 125 13 1625 5-15P Right Angle 50 0.4 22 079407041060 SPT-3 3 16 3 Gray 125 13 1625 5-15P Right Angle 100 0.3 26 079407041039 SPT-3 3 16 6 Gray 125 13 1625 5-15P Straight 50 0.4 19 079407048069 SPT-3 3 16 3 Gray 125 13 1625 5-15P Straight 100 0.3 27 079407048038 Product Construction: Conductor: * 18 AWG and 16 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded PVC Jacket: * PVC; black, gray or beige Applications: * For replacement use 57 UPC CODE Features: * Conductor stripped 5/8" * Free end slit 1 1/2" Industry Approvals: * UL Listed Cord & Cordset Plug-it (R) Extension Cord Accessories 8 Index The Plug-it(R) Fluorescent Light * The Plug-it (R) Ground Fault turns your extension cord into Circuit Interrupter (GFCI) and a light. The portable light has Surge Protector Plug connects no permanent cord attached, to any standard extension providing easy storage when not cord. This handy pocket-size in use. Ideal for contractors and adapter detects power leaks do-it-yourselfers alike, the impactand cuts off electricity in less resistant Plug-it (R) Fluorescent than a second to prevent Light has a 13-watt bulb that electric shock. It is designed runs cool to the touch when in for use anywhere ground fault operation. A cord-locking screw protection is desired, including secures extension cords and job sites, workshops, garages, resists disconnection when in use. kitchens, bathrooms or outdoor outlets, and features Also available in the Plug-it (R) convenient test and reset series are adapters, Powrbuttons. ReelsTM and the GFCI. Page Plug-it(R) Fluorescent Utility Light 59 Plug-it(R) Powr-Center (R) Adapter 59 Powr-ReelTM with 3 Outlets 60 Plug-it(R) Ground Fault Circuit Interrupter (GFCI) and Surge Protector Plug 60 * The Plug-it (R) Powr-Center (R) Adapter features three outlets in a "T" configuration, adapting a single extension cord for more uses. 58 Cord & Cordset Plug-it(R) Extension Cord Accessories Plug-it(R) Fluorescent Utility Light Cordless * Cool-Running * Impact-Resistant Product Description: The impact-resistant Plug-it(R) Fluorescent Light has a 13-watt bulb that runs cool to the touch when in operation. A cord-locking screw secures the extension cord and resists disconnection when in use. CATALOG NUMBER MAXIMUM BULB SIZE (WATTS) 07505.73.05 13 PKG. WT./ WT./ PER UNIT CTN. CTN. LBS LBS 8 1.3 10 Product Construction: UPC CODE 079407075058 Features: Body: * Turns an extension cord into a light * Connects to 3-conductor grounded extension cord * Cool-running 13-watt fluorescent bulb * Rubberized hood * Impact-resistant body and lens * Swivel hook * Locking screw system assures secure cord connections * PVC; yellow Lens: * Clear butyrate Bulb: * PLS 13-watt fluorescent Applications: * Temporary lighting * For general use only * Not for use in hazardous locations Industry Approvals: * UL Listed Plug-it(R) Powr-Center(R) Adapter "T" Configuration--Adapt extension cords for different uses Product Construction: Body: * PVC; beige Applications: * Adapts a single extension cord for multiple uses Features: * 3 convenient outlets 59 CATALOG NUMBER VOLTS AMPS 04781.96.17 125 15 Industry Approvals: * UL Listed WATTS PKG. PER CTN. WT./ UNIT LBS WT./ CTN. LBS UPC CODE COLOR 1875 5 0.6 3 079407047819 Beige Cord & Cordset Plug-it(R) Extension Cord Accessories Powr-ReelTM with 3 Outlets 3-Conductor Grounded * Type SJO * 90C * 300 Volts CATALOG NUMBER NO. LENGTH OF AWG OF CORD COND. SIZE (FT) 44623.61.05 3 16 25 COLOR OF JACKET VOLTS AMPS Yellow 125 10 WATTS PKG. PER CTN. WT./ UNIT LBS WT./ CTN. LBS UPC CODE 1250 4 2.7 11 079407446230 POWER RATING Product Construction: Features: * Tangle-Proof(R) instant cord storage * Sturdy metal reel case * Rubber cord * 3 grounded outlets * Cord locks in place; pull on cord to engage retractable reel Conductor: * 16 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded 90C EPDM Industry Approvals: Jacket: * UL Listed * OSHA Acceptable * CPE; yellow * Voltage rating: 300 volts Applications: * Shop tools Plug-it(R) Ground Fault Circuit Interrupter (GFCI) and Surge Protector Plug PKG. WT./ WT./ PER UNIT CTN. WATTS CTN. LBS LBS POWER RATING CATALOG NUMBER VOLTS AMPS D7524.13.05 125 15 1875 6 0.3 Product Description: The Plug-it(R) Ground Fault Circuit Interrupter and Surge Protector Plug detects power leaks and cuts off electricity in less than one second to prevent electric shock. Product Construction: Body: * PVC; yellow Applications: * Use anywhere GFCI protection is desired: job sites, kitchens, bathrooms, garages and workshops 2 UPC CODE 079407075249 Features: * Detects power leaks and cuts electricity off in less than a second to prevent electric shock * Test and reset buttons * Use with any standard extension cord * Use indoor or outdoor * Protects electrical circuitry from voltage fluctuations * Maximum clamping voltage - 790 volts * MOV - 80 joules Industry Approvals: * UL Listed * OSHA Acceptable 60 Cord & Cordset Specialty Extension Cords and Lighting 9 Index Carol Brand Specialty Extension Cord Products are uniquely designed for specific uses by contractors, do-it-yourselfers and homeowners alike. (R) The Shock Safe(R) 3-outlet Powr-Center (R) has a built-in ground fault circuit interrupter (GFCI) for detecting power leaks. Featuring weatherresistant test and reset buttons, the GFCI cuts off electricity to prevent electric shock. 61 Carol offers 3-outlet Powr-Centers(R) for use when multiple outlets are needed indoors. The three-conductor cords are designed specifically for household, office or workshop use. Carol offers three-conductor standard Utility Lights with plastic or metal guards. Our Brooder Lamp and Clamp Lights are also available to meet your lighting needs. Page Shock Safe(R) Ground Fault Circuit Interrupter (GFCI) Powr-Center(R) 62 Household Powr-Centers(R) 62 Plastic Guard Utility Light 63 Metal Guard Utility Light 63 Brooder and Heat Lamp 64 Clamp Light 64 Specialty Extension Cords and Lighting Cord & Cordset Shock Safe(R) Ground Fault Circuit Interrupter (GFCI) Powr-Center(R) 3 Conductor * Type SJTW * -40C to 60C * 300 Volts POWR-CENTER(R) WITH 3 OUTLETS CATALOG NUMBER NO. OF COND. 04000.63.05 3 LENGTH COLOR AWG OF CORD OF SIZE (FT) JACKET 12 2 PKG. WT./ WT./ PER UNIT CTN. WATTS CTN. LBS LBS POWER RATING Yellow Product Description: VOLTS AMPS 125 15 1875 6 1.3 8 UPC CODE 079407040001 Applications: he Shock Safe(R) 3-outlet Powr-Center(R) has a T built-in GFCI for detecting power leaks. Featuring weather-resistant test and reset buttons, the GFCI cuts off electricity to prevent electric shock. * Power tools * Appliances Features: * Integral GFCI detects power leaks and cuts off electricity to prevent electric shock * Test and reset buttons * 3-conductor grounded Product Construction: Conductor: * 12 AWG stranded bare copper per ASTM B-174 Industry Approvals: * UL Listed * OSHA Acceptable Insulation: * Premium-grade, color-coded PVC Jacket: * PVC; yellow * Temperature range: -40C to 60C * Voltage rating: 300 volts Household Powr-Centers(R) 3-Conductor Grounded * Type SPT-3 and SJT * 60C * 300 Volts CATALOG NUMBER NO. OF COND. 00655.63.04 3 LENGTH COLOR AWG OF CORD OF SIZE (FT) JACKET PKG. WT./ WT./ PER UNIT CTN. WATTS CTN. LBS LBS POWER RATING VOLTS AMPS UPC CODE TYPE SPT-3 14 3 Orange 125 15 1875 10 0.6 6 079407006557 1625 12 0.7 8 079407005659 TYPE SJT 00565.63.17 3 16 9 Beige Product Construction: Conductor: * 16 AWG or 14 AWG stranded bare copper per ASTM B-174 Insulation: * Premium-grade, color-coded PVC Jacket: * PVC; orange or beige * Voltage rating: 300 volts 125 13 Applications: * Clocks * Lamps * Holiday lighting * Other household appliances Features: * 3 grounded outlets Industry Approvals: * UL Listed 62