For low drain / long tetm operating
applications requesting superior
voltage response in -55 ~+85
environments.
Cell size references
Alternative models
Electrical characteristics
(typical values relative to cells stored for one year or less at +30 max.)
Nominal capacity 0.45Ah
(at 0.5 mA +20 2.0V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off).
Open circuit voltage (at +20 ) 3.66V
Nominal voltage (at 0.5mA +20 ) 3.6V
Pulse capability: Typically up to 20 mA (30 mA/0.1 second pulses,
drained every 2 mn at +20 from undischarged cells with 10 A base
current, yield voltage readings above 3.0V. The readings may vary according
to the pulse characteristics, the temperature, and the cell s previous history.
Fitting the cell with a capacitor may be recommended in severe conditions.
Consult ABLE)
Max. Continuous current 10mA
Max. Pulse current 20mA
Storage (recommended) +30 +86 F max
(for more severe conditions, consult ABLE)
Operating temperature range -55 / +85
(Operation above ambient T may lead to reduced capacity and -76 F / +185 F
lower voltage readings at the beginning of pulses. Consult ABLE)
Physical characteristics
Diameter (max) 13mm(0.45 in)
Height (max) 15mm(0.6 in)
Typical weight 5.5g(0.18oz)
Available termination suffix radial tabs, radial pins, axial leads, flying leads
R
Primary lithium batteries
ER13150 3.6V 450mAh
3.6V Primary lithium-thionyl chloride
(Li-SOCl2) Energy type
bobbin cell
Primary Lithium Battery Expert
Tel:0086 755 29807561/63 Fax:0086 755 29807510 Email:able@able-battery.com website:www.able-battery.com