HBD DC/DC Series Data Sheet 60-Watt, Dual Output Features * Independent Dual Outputs * Flexible Load Sharing * High Efficiency Topology * Open-Frame Design * Planar Magnetics * Independent Trim For Each Output * 1500V Isolation * 100C Baseplate Operation Description HBD dual output, DC/DC converters feature high efficiency, 1500 VDC isolation, and open-frame packaging. The HBD family allows board designers to deliver any combination of power from either output, up to each model's maximum rating. The HBD is available in 5V/3.3V or 3.3V/2.5V combinations in either a 24V or 48V input version. The HBD uses planar magnetics and has an MTBF of over a million hours. Efficiency vs. Load (24V Input) 85 Technical Specifications 80 Voltage Range 24 VDC Nominal 48 VDC Nominal Reflected Ripple Input Reverse Voltage Protection 18.00 - 36.00 VDC 34.00 - 75.00 VDC 80 mA Shunt Diode EFFICIENCY % Input 75 HBD060YGE-A 70 EFF. (18V) EFF. (24V) 65 EFF. (36V) 60 10 20 30 40 Output Load Regulation Iout Min. - Iout Max., Vin Nom., Output2 Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range (5V/3.3V Units) Power Limit Threshold Range, % of Iout Rated OVP Trip Range (Main Ouput) 60 70 80 90 100 LOAD % 1% 0.2% Vout 1.0% Vout 0.5% Vout 1.0% Vout 10% Iout Rated 25% Iout 4% Vout 500 m s 10% 110 - 140% 115 - 140% Vout Nom. Efficiency vs. Load (48V Input) 85 80 75 EFFICIENCY % Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated, Output 1 Line Regulation Vin Min. - Vin Max., Iout Rated, Output 2 Load Regulation Iout Min. - Iout Max., Vin Nom., Output 1 50 70 HBD060ZGE-A 65 HBD040ZGE-A 60 HBD040ZED-A 55 50 10 20 30 40 50 60 70 80 90 100 LOAD % General Turn-On Time Remote Shutdown Switching Frequency Isolation Input - Output Input - Case Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Thermal Shutdown Range Humidity Max., Non-Condensing Vibration, 3 Axes, 5 Min Each MTBF (Bellcore TR-NWT-000332) Safety Weight (approx.) 10 ms Positive Logic 500 kHz 1500 VDC 1050 VDC 500 VDC 0.03%/C -40 To +100C -40 To +125C 105 To 115C 95% 5g 6 1.3 x 10 Hrs UL, cUL, VDE 2.4 oz REV. SEP 05, 2003 Page 1 of 3 Notes 1 For negative logic, add suffix "N" to model number. MTBF predictions may vary slightly from model to model. Specifications typically at 25C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with commercial wave-soldering equipment. Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. HBD DC/DC Series Data Sheet 60-Watt, Dual Output Model Selection MODEL INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) RATED OUTPUT CURRENT (AMPS) 24 24 24 48 48 48 18-36 18-36 18-36 34-75 34-75 34-75 2.89 4.54 3.02 1.51 1.62 2.27 3.3/2.5 5.0/3.3 5.0/3.3 5.0/3.3 3.3/2.5 5.0/3.3 12/15 12/15 8/12 8/12 12/15 12/15 HBD040YED-A HBD060YGE-A HBD040YGE-A HBD040ZGE-A HBD040ZED-A HBD060ZGE-A NOTES: RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY** 75/75 100/75 100/75 100/75 75/75 75/75 75% 78% 80% 80% 75% 75% * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. Note: Current can be drawn from either output to its maximum value, or from both outputs to a combined total of 15A. Mechanical Drawing $ $! $% % ! "# Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 6.6 C/W 5.7 C/W 4.2 C/W 3.1 C/W 2.6 C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. Pin Function 1 -Vin 2 3 4 Case On/Off +Vin 5 +Vout 2 6 - Vout 2 7 8 Trim 2 +Vout 1 9 -Vout 1 Trim 1 10 REV. SEP 05, 2003 Page 2 of 3 Tolerances Inches: .XX 0.020 .XXX 0.010 Pin: 0.002 (Millimeters) .X 0.5 .XX 0.25 0.05 (Dimensions as listed unless otherwise specified.) OPTIONS This page is offered as a reference. Consult factory for actual availability of options. When ordering equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the model number. Ordering option examples are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, QBS, QES, QLS, TES, TQD Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES, QLS Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES Pin Length and Heatsink Options REMARKS TTL "Low" Turns Module ON TTL "High" Turns Module OFF Standard Pin Length is 0.180" (4.6mm) 0.110" (2.8mm) Pin Length 8 All Leaded Models 0.150" (3.8mm) Pin Length 9 All Leaded Models 0.24" (6.1mm) Horizontal Heatsink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.24" (6.1mm) Vertical Heatsink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Horizontal Heatsink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Vertical Heatsink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Horizontal Heatsink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Vertical Heatsink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad Example Options: HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95" vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110" pin length. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. SEP 05, 2003 Page 3 of 3