Page 1 of 3
HBD DC/DC Series Data Sheet
REV. SEP 05, 2003
60-Watt, Dual Output
HBD060YGE-A
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
EFF. (18V)
EFF. (24V)
EFF. (36V)
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
HBD060ZGE-A
HBD040ZGE-A
HBD040ZED-A
Technical Specifications
Voltage Range
24 VDC Nominal 18.00 - 36.00 VDC
48 VDC Nominal 34.00 - 75.00 VDC
Reflected Ripple 80 mA
Input Reverse Voltage Protection Shunt Diode
HBD dual output, DC/DC converters feature high efficiency, 1500 VDC isolation, and open-frame packaging. The HBD
family allows board designers to deliver any combination of power from either output, up to each model’s maximum
rating. The HBD is available in 5V/3.3V or 3.3V/2.5V combinations in either a 24V or 48V input version. The HBD uses
planar magnetics and has an MTBF of over a million hours.
Independent Dual Outputs
Flexible Load Sharing
High Efficiency Topology
Open-Frame Design
Planar Magnetics
Independent Trim For Each Output
1500V Isolation
100°C Baseplate Operation
Description
Features
Input
Efficiency vs. Load (24V Input)
Efficiency vs. Load (48V Input)
Notes
1For negative logic, add suffix “N” to model number.
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
Turn-On Time 10 ms
Remote Shutdown Positive Logic
Switching Frequency 500 kHz
Isolation
Input - Output 1500 VDC
Input - Case 1050 VDC
Output - Case 500 VDC
Temperature Coefficient 0.03%/°C
Case Temperature
Operating Range -40 To +100°C
Storage Range -40 To +125°C
Thermal Shutdown Range 105 To 115°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g
MTBF(Bellcore TR-NWT-000332) 1.3 x 106Hrs
Safety UL, cUL, VDE
Weight (approx.) 2.4 oz
General
Setpoint Accuracy ±1%
Line Regulation Vin Min. - Vin Max., Iout Rated, Output 1 0.2% Vout
Line Regulation Vin Min. - Vin Max., Iout Rated, Output 2 1.0% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom., Output 1 0.5% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom., Output2 1.0% Vout
Minimum Output Current 10% Iout Rated
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500 ms
Voltage Trim Range (5V/3.3V Units) ±10%
Power Limit Threshold Range, % of Iout Rated 110 - 140%
OVP Trip Range (Main Ouput) 115 - 140% Vout Nom.
Output
Page 2 of 3
MODEL INPUT VOLTAGE INPUT VOLTAGE MAXIMUM INPUT OUTPUT RATED OUTPUT RIPPLE & NOISE TYPICAL
(VOLTS) RANGE (VOLTS) CURRENT (AMPS)* VOLTAGE (VOLTS) CURRENT (AMPS) pk-pk (mV) EFFICIENCY**
HBD040YED-A 24 18-36 2.89 3.3/2.5 12/15 75/75 75%
HBD060YGE-A 24 18-36 4.54 5.0/3.3 12/15 100/75 78%
HBD040YGE-A 24 18-36 3.02 5.0/3.3 8/12 100/75 80%
HBD040ZGE-A 48 34-75 1.51 5.0/3.3 8/12 100/75 80%
HBD040ZED-A 48 34-75 1.62 3.3/2.5 12/15 75/75 75%
HBD060ZGE-A 48 34-75 2.27 5.0/3.3 12/15 75/75 75%
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Note: Current can be drawn from either output to its maximum value, or from both outputs to a combined total of 15A.
HBD DC/DC Series Data Sheet
REV. SEP 05, 2003
60-Watt, Dual Output
Thermal Impedance
Natural Convection 6.6 °C/W
100 LFM 5.7 °C/W
200 LFM 4.2 °C/W
300 LFM 3.1 °C/W
400 LFM 2.6 °C/W
Tolerances
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
Mechanical Drawing
1-V
in
2 Case
3 On/Off
4+V
in
5+V
out 2
6- V
out 2
7 Trim 2
8+V
out 1
9-V
out 1
10 Trim 1
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
(Dimensions as listed unless otherwise
specified.)
Pin Function

 















 

 






  ! "#
 $$! $%%




Model Selection
Page 3 of 3
REV. SEP 05, 2003
OPTIONS
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Pin Length and Heatsink Options Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length 8 All Leaded Models
0.150" (3.8mm) Pin Length 9 All Leaded Models
0.24" (6.1mm) Horizontal Heatsink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heatsink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heatsink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heatsink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
This page is offered as a reference. Consult factory for actual availability of options. When ordering equip-
ment options, use the following suffix information. Select preferred option(s) and add the suffix to the model
number. Ordering option examples are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equip-
ment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.