RT-3
Semirigid, flame-retardant polyolefin
heat-shrinkable tubing
RT-3 tubing is ideally suited for wire
strain-relief applications. It provides
excellent strain relief and insulation of
“weak points,” transferring flex stress
away from solder and crimp joints
and other typically sensitive wire-
splice and termination points.
RT-3 is especially well suited for
semi-automated production
equipment requiring tubing with a
tightly controlled expanded
diameter. Sizes and expansion
ratios of RT-3 are available for
specific spade/disconnect terminals.
RT-3 tubing is made from a semirigid,
radiation-crosslinked, flame-retardant
polyolefin. Unlike other typical flame-
retardant tubings, RT-3 tubing is free
of polybrominated biphenyls (PBBs)
and polybrominated biphenyl oxides
(PBBOs). In Europe, these chemicals
are classified as environmentally
hazardous substances.
RT-3 is UL-recognized in all colors
and CSA- certified in black at
125°C, 600 V.
Temperature rating
Full recovery temperature: 135°C
Continuous operating temperature: 55°C to 135°C
Specifications*
Type Raychem UL CSA
RT-3 RT-360** E35586 LR31929 (Black only)
* When ordering, always specify latest issue.
** Except dimensions and longitudinal change.
Dimensions (millimeters/inches)
Inside diameter Wall thickness
D d (max.) W
Expanded Recovered after Recovered after
Size* as supplied heating heating***
RT-3 No. 1 6.1 ± 0.4 0.240 ± 0.015 2.4 0.095 0.79 ± 0.08 0.031 ± 0.003
RT-3 No. 2 8.1 ± 0.4 0.320 ± 0.015 3.2 0.125 0.79 ± 0.08 0.031 ± 0.003
RT-3 No. 3 9.5 ± 0.5 0.375 ± 0.020 3.8 0.150 0.79 ± 0.08 0.031 ± 0.003
RT-3 No. 4 12.3 ± 0.5 0.485 ± 0.020 5.1 0.200 0.79 ± 0.08 0.031 ± 0.003
***Wall thickness will be less if tubing recovery is restricted during shrinkage.
Ordering information
Color Standard Black only.
Size selection Always order the largest size that will shrink snugly over the component being covered.
A variety of nonstandard sizes are available.
Standard packaging 1-inch cut-pieces or 4-foot lengths
Ordering description Specify product name, size, and color; for example, RT-3 No. 1-0 (0=Black).
®
Fully recovered after heating
D
W
d
Expanded as supplied
PBBs
PBBEs
PBBOs
Tyco Electronics Corporation
300 Constitution Drive Faraday Road 3816 Noborito, Tama-ku Asia Pacific Headquarters
Menlo Park, CA 94025-1164 Dorcan, Swindon, SN3 5HH Kawasaki, Kanagawa 214-8533 26 Ang Mo Kio, Industrial Park 2
USA United Kingdom Japan Singapore 569507
Tel:(800) 926-2425 (US & Canada) Tel: +44 1793 528171 Tel: +81 44 900 5102 Tel: +65 4866 151
Tel:+1 (650) 361-3860 (All other countries)
Users should independently evaluate the suitability of the product for their application.
For more information about this product visit www.tycoelectronics.com
All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics Corporation makes
no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics Corporation’s only obligations are those in the Standard Terms and
Conditions of Sale for these products and in no case will Tyco Electronics Corporation be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the
product. Tyco Electronics Corporation’s Specifications are subject to change without notice. In addition, Tyco Electronics Corporation reser ves the right to make changes in materials or processing
without notification to the Buyer which do not affect compliance with any applicable specification.
Specification values
Property Unit Requirement Method of test
Physical Dimensions mm (inches) See reverse ASTM D 2671
Longitudinal change percent +0, 10 ASTM D 2671
Tensile strength psi (MPa) 2000 (13.8) minimum ASTM D 2671
Ultimate elongation percent 200 minimum ASTM D 2671
Secant modulus (expanded) psi (MPa) 2.5 x 104(172) minimum ASTM D 2671
Specific gravity 1.35 maximum ASTM D 2671
Low-temperature flexibility No cracking ASTM D 2671
(4 hours at 55°C/67°F)
Heat shock No dripping, flowing, ASTM D 2671
(4 hours at 250°C/482°F) or cracking
Heat resistance ASTM D 2671
(168 hours at 175°C/347°F)
Followed by test for:
Ultimate elongation percent 150 minimum ASTM D 2671
Electrical Dielectric strength volts/mil (kV/mm) 500 (19.7) minimum ASTM D 2671
Volume resistivity ohm-cm 1014 minimum ASTM D 2671
Chemical Copper mirror corrosion Noncorrosive ASTM D 2671
(16 hours at 150°C/302°F) Procedure A
Copper contact corrosion No pitting or blackening ASTM D 2671
(168 hours at 150°C/302°F) of copper Procedure B
Flammability Self-extinguishing within ASTM D 2671
1 minute; no more than 25% Procedure B
of indicator burned or charred;
no falling, burning particles.
Fungus resistance ISO 846
Followed by tests for: Method B
Tensile strength psi (MPa) 2000 (13.8) minimum ASTM D 2671
Ultimate elongation percent 200 minimum ASTM D 2671
Dielectric strength volts/mil (kV/mm) 500 (19.7) minimum ASTM D 2671
Water absorption percent 0.5 maximum ASTM D 2671
(24 hours at 23°C/73°F)
Fluid resistance ASTM D 2671
(24 hours at 23°C/73°F) in:
JP-8 fuel (MIL-T-5624)
Skydrol 500
Hydraulic fluid (MIL-H-5606)
Aviation gasoline 100/300
(MIL-G-5572)
Water
Followed by tests for:
Dielectric strength volts/mil (kV/mm) 400 (15.8) minimum ASTM D 2671
Tensile strength psi (MPa) 1600 (11.0) minimum ASTM D 2671
Note: Consult RT-360 for specific details about test procedures.
Skydrol is a trademark of Monsanto Company.
Raychem is a trademark of Tyco Electronics Corporation.
© 1988, 1990, 1995, 2002 Tyco Electronics Corporation Printed in USA 1654050 Revised 04/04