Ordering information Power module type CBS200 CB 1 S 2 200 3 48 4 12 5 -O 6 1Series name 2Single output 3Output wattage 4Input voltage 24:DC18 - 36V 48:DC36 - 76V 5Output voltage 6Optional R :with Remote ON/OFF Positive logic control T :with Mounting hole f3.4 thru FO:with Addition of a Heat sink R MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT CBS2002403 CBS2002405 CBS2002412 CBS2002415 CBS2002424 CBS2002428 CBS2004803 CBS2004805 CBS2004812 CBS2004815 CBS2004824 CBS2004828 115.5 150.0 200.4 201.0 201.6 201.6 115.5 150.0 200.4 201.0 201.6 201.6 3.3V 35A 5V 30A 12V 16.7A 15V 13.4A 24V 8.4A 28V 7.2A 3.3V 35A 5V 30A 12V 16.7A 15V 13.4A 24V 8.4A 28V 7.2A SPECIFICATIONS INPUT OUTPUT MODEL VOLTAGE[V] *1 CURRENT[A] *1 EFFICIENCY[%] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] -20 to +100C *2 RIPPLE[mVp-p] -40 to -20C *2 -20 to +100C *2 RIPPLE NOISE[mVp-p] -40 to -20C *2 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *3 DRIFT[mV] START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *4 PROTECTION CIRCUIT AND OTHERS ISOLATION CBS ENVIRONMENT SAFETY OTHERS OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-CASE PIN, BASE PLATE OUTPUT-CASE PIN, BASE PLATE OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CASE SIZE/WEIGHT COOLING METHOD CBS2002403 CBS2002405 CBS2002412 CBS2002415 CBS2002424 CBS2002428 CBS2004803 CBS2004805 CBS2004812 CBS2004815 CBS2004824 CBS2004828 DC18 - 36 DC36 - 76 6.09typ 7.62typ 9.60typ 9.63typ 9.66typ 9.66typ 3.01typ 3.77typ 4.74typ 4.76typ 4.77typ 4.77typ 79typ 82typ 87typ 87typ 87typ 87typ 80typ 83typ 88typ 88typ 88typ 88typ 3.3 5 12 15 24 28 3.3 5 12 15 24 28 35.0 30.0 16.7 13.4 8.4 7.2 35.0 30.0 16.7 13.4 8.4 7.2 10max 10max 24max 30max 48max 56max 10max 10max 24max 30max 48max 56max 10max 10max 24max 30max 48max 56max 10max 10max 24max 30max 48max 56max 80max 80max 120max 120max 120max 120max 80max 80max 120max 120max 120max 120max 120max 120max 150max 150max 150max 150max 120max 120max 150max 150max 150max 150max 120max 120max 150max 150max 150max 150max 120max 120max 150max 150max 150max 150max 200max 200max 200max 200max 250max 250max 200max 200max 200max 200max 250max 250max 35max 50max 120max 150max 240max 280max 35max 50max 120max 150max 240max 280max 66max 100max 240max 300max 480max 560max 66max 100max 240max 300max 480max 560max 16max 20max 40max 60max 90max 90max 16max 20max 40max 60max 90max 90max 200max (DCIN 24V, Io=100%) 200max (DCIN 48V, Io=100%) Fixed (TRM pin open), 60 - 110% adjustable by external resistor 1.98 - 3.63 3.0 - 5.5 7.2 - 13.2 9.0 - 16.5 14.4 - 26.4 16.8 - 30.8 1.98 - 3.63 3.0 - 5.5 7.2 - 13.2 9.0 - 16.5 14.4 - 26.4 16.8 - 30.8 3.25 - 3.45 4.90 - 5.20 11.74 - 12.46 14.55 - 15.45 23.28 - 24.72 27.16 - 28.84 3.25 - 3.45 4.90 - 5.20 11.74 - 12.46 14.55 - 15.45 23.28 - 24.72 27.16 - 28.84 Works over 105% of rating and recovers automatically 4.00 - 5.50 5.75 - 7.00 13.80 - 16.80 17.25 - 21.00 27.60 - 33.60 32.20 - 39.20 4.00 - 5.50 5.75 - 7.00 13.80 - 16.80 17.25 - 21.00 27.60 - 33.60 32.20 - 39.20 Provided Provided (Negative logic L : ON, H : OFF) DC1,500V or AC1,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(20t15C) DC1,500V or AC1,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(20t15C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20t15C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950, C-UL, EN60950 57.9X12.7X61.0mm (WXHXD) / 83g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1 At rated input(DC24V,DC48V) and rated load. *2 Ripple and ripple noise is measured by using measuring board with recommended capacitor Co & the film capacitor 0.1mF. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:RM101). *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *4 When the input voltage is in the range of DC18 - 20V, DC36 - 40V, output voltage adjustment range is 60 - 105%. G-64