Keysight U1190 Series
Clamp Meters
Data Sheet
Introduction
Keysight Technologies, Inc., U1190 Series clamp meters are packed with a wealth of features to help
you work more conveniently and more safely. Designed in a robust case—the unique wire separator

area while Vsense performs non-contact voltage detection. What’s more, the U1190 Series clamp

retool your expectations in handheld tools.
3
Figure 1. The unique wire separator
allows you to separate and measure
individual wires more easily
Unique wire separator with

The U1190 Series clamp meters are built to
perform in the environments you work.
The unique wire separator allows you to
effortlessly isolate and perform measure-
ments on individual wires in a bundle.
For improved visibility when making
measurements, these clamp meters also
come with an easily activated built-in LED
flashlight that illuminates the test area.
These features ensure that you are better
equipped when making measurements.
Vsense for non-contact
voltage detection
The U1190 Series clamp meters have
Vsense—a unique method of non-contact
voltage detection that safeguards users
from exposure to hot or live wires while
making measurements in dangerous work-
ing environments. Upon the detection of
voltage, a unique safety alert of an audible
beeper is produced to alert users.
Ergonomically built with
current measurement
up to 600 A
Ergonomically built, the U1190 Series
clamp meters fit comfortably in the palm
of your hand and allow you to select
measurement functions with just a simple
thumb press. Better yet, the U1193A and
U1194A come with a current measurement
up to 600 A. The wide range of current
measurement functions cover an array of
applications such as electrical installation,
maintenance, and troubleshooting tasks—
making it an ideal tool to use across many
industrial applications.
Features
The U1190 Series clamp meters
include:
Unique wire separator to separate
wires from a bundle
Vsense to perform non-
contact voltage detection1
Built-in LED flashlight to illumi-
nate test area1
Visual (backlight alert) and
audible continuity indication
in noisy environments
Current measurement up to
600 A2
Digital multimeter (DMM) with
resistance, capacitance1, DCV,
ACV, DCA3, ACA, DCµA3 and
ACµA3 measurement
capabilities
Continuity and diode test mea-
surements
CAT III 600 V / CAT IV 300 V
safety rating
1. Exclusive to U1192A, U1193A,
and U1194A.
2. Exclusive to U1193A and U1194A.
3. Exclusive to U1194A.
4
Take a Closer Look
Unique wire separator to
separate and clamp wires
from a bundle
Data Hold, Min, or Max
recording capability
LCD display with maximum
reading of 6,000 counts
Backlight display and
built-in LED flashlight1
Figure 2. Built-in LED flashlight
to illuminate test area
Vsense performs non-
contact voltage detection1,
DCµA2, and ACµA2 current
measurements
1. Exclusive to U1192A, U1193A, and U1194A.
2. Exclusive to U1194A.
Capacitance/Diode
test measurements
Resistance/Continuity
measurements
DCV, ACV, DCA2, ACA, and
frequency measurement
capabilites
5
Model Comparison
U1191A U1192A U1193A U1194A
Basic features
Display 6,000 counts 6,000 counts 6,000 counts 6,000 counts
RMS method Average responding Average responding True RMS True RMS
Measurement range
DC voltage 600 V 60 to 600 V 60 to 600 V 60 to 600 V
AC voltage 600 V 60 to 600 V 60 to 600 V 60 to 600 V
DC current 60 to 600 A
DC µA current 60 to 600 µA
AC current 400 A 60 to 400 A 60 to 600 A 60 to 600 A
AC µA current 60 to 600 µA
Resistance 600 Ω to 6 kΩ 600 Ω to 60 kΩ 600 Ω to 60 kΩ 600 Ω to 60 kΩ
Capacitance 600 µF to 6 mF 600 µF to 6 mF 600 µF to 6 mF
Diode 1.5 V 1.5 V 1.5 V 1.5 V
Continuity 600 Ω 600 Ω 600 Ω 600 Ω
Temperature K-type: –40 to 1,200 °C
Frequency 99.99 Hz to 99.99 kHz 99.99 Hz to 99.99 kHz 99.99 Hz to 99.99 kHz
Data management
Data hold Yes Yes Yes Yes
Null Yes Yes Yes Yes
MAX/MIN/AVG Yes Yes Yes Yes
Auto/Range Yes1Yes Yes Yes
Other features
Built-in LED flashlight No Yes Yes Yes
Auto power OFF Yes Yes Yes Yes
Clamp opening 31 mm 31 mm 37 mm 37 mm
Clamping diameter 27 mm 27 mm 35 mm 35 mm
Safety and regulatory
Over-voltage safety
protection
CAT III 600 V/
CAT IV 300 V
CAT III 600 V/
CAT IV 300 V
CAT III 600 V/
CAT IV 300 V
CAT III 600 V/
CAT IV 300 V
EN/IEC 61010-1, CE,
CSA compliance
Yes Yes Yes Yes
1. Applicable to Resistance range only.
6


Accuracy is given as ± (% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity less than 80% RH. AC voltage
and AC current specifications for U1193A and U1194A are AC coupled, true rms and are valid from 5% of range to 100% of range. The crest
factor may be up to 3.0 at 4,000 counts. For non-sinusoidal waveforms, add additional accuracy of (2% reading + 2% full scale) typically. In
the EMC RF field of 3 V/m, total accuracy is specified as specified accuracy + 30 digits for all functions.

Function Range Resolution
Accuracy
U1191A U1192A U1193A U1194A
Voltage
60 V 0.01 V 0.5% + 3 0.5% + 3 0.5% + 3
600 V 0.1 V 0.5% + 3 0.5% + 3 0.5% + 3 0.5% + 3
Resistance
600 Ω 0.1 Ω 0.8% + 5 0.8% + 5 0.8% + 5 0.8% + 5
6 kΩ 0.001 kΩ 0.8% + 3 0.8% + 3 0.8% + 3 0.8% + 3
60 kΩ 0.01 kΩ 0.8% + 3 0.8% + 3 0.8% + 3
Diode
1.5 V 0.001 V 1.0% + 3 1.0% + 3 1.0% + 3 1.0% + 3
Current
60 µA 0.01 µA 1.0% + 5
600 µA 0.1 µA 1.0% + 5
60 A 0.01 A 2.0% + 5
600 A 0.1 A 2.0% + 5
Notes for DC voltage specification:
1. Input impedance of 10 MΩ.
Notes for resistance specifications:
1. Overload protection: 600 Vrms for short circuits with < 0.1 mA current.
2. Maximum open voltage is < 1.4 V.
3. The accuracy is specified after the Relative function is used to subtract the test lead resistance and thermal effect (by shorting the test leads).
Notes for diode specifications:
1. Overload protection: 600 Vrms for short circuits with < 0.4 mA current.
2. Maximum open voltage is 1.8 V.
3. Built-in buzzer beeps continuously when the voltage measured is less than 100 mV and beeps once for forward-biased diode or semiconductor
junctions measured between 0.3 and 0.8 V (0.3 V ≤ reading ≤ 0.8 V).
Notes for DC current specifications:
1. DC current measurement is only available for U1194A model.
2. 60 to 600 A ranges are from clamp current measurement. 60 to 600 µA ranges are from digital multimeter measurement.
3. Overload protection for 60 to 600 A range: 600 Arms.
4. Position error: 1% from reading.
5. Use Relative mode to zero residual offset.
7


Range Resolution
Voltage accuracy (45 to 500 Hz)
U1191A U1192/3/4A
60 V 0.01 V 1.2% + 5
600 V 0.1 V 1.2% + 5 1.2% + 5
Notes for AC voltage:
1. Input impedance 10 MΩ (nominal) in parallel with < 100 pF.
2. Frequency response: 45 to 500 Hz (sine wave).

Range Resolution
U1191A3U1192A3U1193A4U1194A4
Current
accuracy
(45 to
65 Hz)
Current
accuracy
(65 to
500 Hz)
Current
accuracy
(45 to
65 Hz)
Current
accuracy
(65 to
500 Hz)
Current
accuracy
(45 to
65 Hz)
Current
accuracy
(65 to
500 Hz)
Current
accuracy
(45 to
65 Hz)
Current
accuracy
(65 to
500 Hz)
60 µA 0.01 µA 1.0% + 5 1.0% + 5
600 µA 0.1 µA 1.0% + 5 1.0% + 5
60 A 0.01 A 2.0% + 5 3.0% + 5 2.0% + 5 3.0% + 5 2.0% + 5 3.0% + 5
400 A 0.1 A 2.0% + 5 3.0% + 5 2.0% + 5 3.0% + 5
600 A 0.1 A 2.0% + 5 3.0% + 5 2.0% + 5 3.0% + 5
Notes for AC current:
1. Frequency response: 45 to 500 Hz (sine wave).
2. Position error: 1% of reading.
3. AC conversion type for U1191A and U1192A: Average sensing, RMS indication.
4. AC conversion type for U1193A and U1194A: RMS sensing, RMS indication.
5. Maximum overload: 400 A RMS.
6. For non-sinusoidal waveform, add additional accuracy of (2% reading + 2% full scale) typically for crest factor ≥ 3.0.

Range Resolution
Accuracy
U1191A U1192/3/4A
600 µF 0.1 µF 2.0% + 4
6 mF 0.001 mF 2.0% + 4
Notes for capacitance specifications:
1. Capacitance measurement is not available with U1191A model.
2. Overload protection: 600 Vrms for short circuits with < 0.1 mA current.
3. The accuracy for all ranges is specified based on a film capacitor or better, and use Relative mode.
8


Thermal type Range Resolution
Accuracy
U1194A
K
–40 to 400 °C 0.1 °C 1.0% + 2.0 °C
400 to 1,200 °C 1.0 °C 1.0% + 2.0 °C
–40 to 752 °F 0.1 °F 1.0% + 3.6 °F
752 to 2,192 °F 1.0 °F 1.0% + 3.6 °F
Notes for temperature specifications:
1. Temperature measurement is only available with the U1194A model.
2. The accuracy does not include the tolerance of the thermocouple probe, and the meter should be put on a place that has been operating for a
minimum of one hour.
3. Do not allow the temperature sensor to contact a surface that is energized above 30 Vrms or 60 V DC. Such voltage poses a shock hazard.
4. The temperature calculation is specified according to the safety standards of EN/IEC-60548-1 and NIST175.
5. Accuracy specification assumes the surrounding temperature is stable with ±1 °C. For the surrounding temperature changes of ±3 °C, rated accuracy
applies after two hours.

Range Resolution
Accuracy
U1192/3/4A
99.99 Hz 0.01 Hz 0.5% + 3
999.9 Hz 0.1 Hz 0.5% + 3
9.999 kHz 0.001 kHz 0.5% + 3
99.99 kHz 0.01 kHz 0.5% + 3
Notes for frequency specifications:
1. Exclusive to U1192A, U1193A, and U1194A.
2. Overload protection: 600 V.
3. Minimum frequency is 10 Hz.
9

For voltage measurements
Input range Minimum sensitivity (rms sine wave)

10 Hz to 10 kHz 10 to 60 kHz
U1192/3/4A U1192/3/4A
60 V 6.0 V 30 V
600 V 60 V -
For current measurements
Input range Minimum sensitivity (rms sine wave)

45 Hz to 1 kHz
U1192/3/4A
60 A 6.0 A
600 A 60 A

Range Resolution
Accuracy
U1191A U1192A U1193A U1194A Test current
600 Ω 0.1 Ω 0.8% + 5 0.8% + 5 0.8% + 5 0.8% + 3 0.1 mA
Notes for continuity specifications:
1. Overload protection: 600 Vrms for short circuits with < 0.1 mA current.
2. Maximum open voltage is 1.4 V.
3. Built-in buzzer beeps continuously when the reading measured is less than 30 Ω and does not beep when the measured resistance is more than
200Ω. Buzzer may either sound or not between 30 Ω and 200 Ω.
4. Continuity indicator: 2.7 kHz tone buzzer.
Measuring rate (approximate)
Function
Times/second
U1191A U1192A U1193A U1194A
AC V 3 3 3 3
DC V 3 3 3 3
Ω 2 2 2 2
Diode 3 3 3 3
Capacitance 2 times/second for 600 µF
1 time/9 seconds for 6 mF
2 times/second for 600 µF
1 time/9 seconds for 6 mF
2 times/second for 600 µF
1 time/9 seconds for 6 mF
Temperature 2
DC A 3
AC A 3 3 3 3
Frequency 3 (> 10 Hz) 3 (> 10 Hz) 3 (> 10 Hz)
10
Product Characteristics
Power supply
Battery type 2 x 1.5 V AAA Alkaline battery
Battery life Approximately 40 hours with backlight on
Approximately 200 hours with backlight off and continuous DC voltage measurement
Power consumption Approximately 9 mVA with backlight off and DC voltage measurement
Approximately 42 mVA with backlight on and DC voltage measurement
Display Liquid crystal display (LCD) (with maximum reading of 6,000 counts)
Operating environment Operating temperature from –10 to 50°C, 0 to 80% RH
Altitude up to 2,000 meters
Pollution degree II
Relative humidity (RH) Relative humidity up to 80% RH for temperature up to 30 °C decreasing linearly to 50% RH at 50 °C
Storage compliance –40 to 60 °C, 40% to 80% RH without batteries
Safety compliance Low Voltage Directive (2006/95/EC)
IEC 61010-1:2001/EN 61010-1:2001
IEC 61010-2-032:2002/EN 61010-2-032:2002
CAN/CSA-C22.2 No. 61010-1-04
CAN/CSA-C22.2 No. 61010-2-032-04
ANSI/UL Std No. 61010-1:2004
Measurement category CAT III 600 V / CAT IV 300 V
Electromagnetic
compatibility (EMC)
EMC Directive (2004/108/EC)
IEC 61326-1:2005/EN61326-1:2006
Canada: ICES/NMB-001: Issue 4, June 2006
Australia/New Zealand: AS/NZS CISPR 11:2004
Temperature coefficient 0.1 x (specified accuracy)/°C (from 0 to 18 °C, or 28 to 50 °C)
Common mode rejection
ratio (CMRR)
> 60 dB at 50/60 Hz in the AC V function
> 120 dB at DC, 50/60 Hz in the DC V function
Dimensions (W x H x D) U1191/2A: 77.1 x 225.0 x 38.6 mm
U1193/4A: 77.1 x 238.0 x 38.6 mm
Warranty1 Three years for product
Three months for product’s standard accessories (unless otherwise specified)
Weight (with batteries) U1191/2A: 320 g
U1193A: 334 g
U1194A: 348 g
Calibration cycle One year
Notes:
1. Please refer to http://www.keysight.com/go/warranty_terms.
Please note that for the product, the warranty does not cover:
Damage from contamination
Normal wear and tear of mechanical components
Manuals and batteries
11
Ordering Information
Standard shipped items
Certificate of calibration
Quick Start Guide
K-type thermocouple (only for U1194A)
1.5 V AAA Alkaline battery
Soft carrying case
Test leads with 4-mm tips
Recommended accessories
U1168A Standard test lead kit
U1169A Test Probe Leads
U1176A LED Probe Clip Light
U1178A Soft carrying case
U1181A Immersion temperature probe
U1182A Industrial surface temperature probe
U1183A Air temperature probe
U1184A Temperature probe adaptor
U1186A K-type thermocouple extension grade
U1188A K-type thermocouple grade
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight

www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444

Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 0800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637

www.keysight.com/find/contactus
(BP-05-29-14)
12 | Keysight | U1190 Series Clamp Meters - Data Sheet
This information is subject to change without notice.
© Keysight Technologies, 011 – 2014
Published in USA, August 1, 2014
5990-8646EN
www.keysight.com
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.keysight.com/quality
Keysight Electronic Measurement Group

Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners

breadth, combined with channel partner convenience.
www.keysight.com/find/handheldmm
www.keysight.com/find/U1190clamp