CSM_E2FQ_DS_E_5_1
1
Chemical-resistant Proximity Sensor
E2FQ
Inductive Profoximity Sensor with
Chemical-resistant Fluororesin Case
Housing and mounting are made of Fluororesin resistant to
chemicals.
Maximum sensing distance: 10 mm.
Note: The cable is made of vinyl chloride and requires separate protection.
Ordering Information
Sensors [Refer to Dimensions on page 6.]
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 5.
Appearance Sensing distance Output configuration Operation mode Model
M12 DC 2-wire
NO
E2FQ-X2D1 2M
DC 3-wire, NPN E2FQ-X2E1 2M
M18
DC 2-wire E2FQ-X5D1 2M
DC 3-wire, NPN E2FQ-X5E1 2M
AC 2-wire E2FQ-X5Y1 2M
M30
DC 2-wire E2FQ-X10D1 2M
DC 3-wire, NPN E2FQ-X10E1 2M
AC 2-wire E2FQ-X10Y1 2M
Shielded
2 mm
5 mm
10 mm
E2FQ
2
Ratings and Specifications
* The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
Model E2FQ-X2E1
E2FQ-X2D1
E2FQ-X5E1
E2FQ-X5D1, E2FQ-X5Y1
E2FQ-X10E1
E2FQ-X10D1, E2FQ-X10Y1
Item
Sensing distance 2 mm ±10% 5 mm ±10% 10 mm ±10%
Set distance 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential travel E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 3.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *E1 Models: 1.5 kHz
D1 Models: 800 Hz
E1 Models: 600 Hz
D1 Models: 500 Hz
E1 Models: 400 Hz
D1 Models: 300 Hz
Y1 Models: 25 Hz
Power supply voltage
(operating voltage
range)
E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz
D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.
Current consumption E1 Models: 17 mA max.
Leakage current D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC)
Control
output
Load
current E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA
Residual
voltage
E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m)
Y1 Models: Refer to Engineering Data on page 3.
D1 Models: 3 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators E Models: Detection indicator (red), Y Models: Operation indicator (red),
D Models: Operation indicator (red), Setting indicator (green) (NO only)
Operation mode
(with sensing object
approaching)
E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.)
Protection circuits E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge sup-
pressor
Ambient temperature
range Operating/Storage: 25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence
E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
D1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range
Y1 Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each
in X, Y, and Z directions Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Cable length: 2 m)
Weight (packed state) Approx. 70 g Approx. 130 g Approx. 170 g
Materials
Case
Fluororesin
Sensing
surface
Clamping
nuts
Toothed
washer Zinc-plated iron
Cable Vinyl chloride
Accessories Instruction manual
3
E2FQ
Engineering Data (Reference Value)
Sensing Area
E2FQ-X@
Influence of Sensing Object Size and Material
E2FQ-X2@E2FQ-X5@E2FQ-X10@
Residual Output Voltage
E2FQ-X@E2FQ-X@Y1 at 24 VAC
Y
X
8
4
2
6
10
-20 -16 -12 -8 -4 0 4 8 12 16
E2FQ-X10
E2FQ-X5
E2FQ-X2
Distance Y
(mm)
Distance X (mm)
E2FQ-X2 Sensing Head
E2FQ-X5 Sensing Head
E2FQ-X10 Sensing Head
2.4
2.2
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0 5 10 15 20 25
X
d ×
d t = 1
mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless steel
(SUS304)
Iron
Brass
12
11
10
9
8
7
6
5
4
3
2
1
100
X
403020 6050
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless
steel
(SUS304)
Iron
Brass
5
4
3
2
1
0
1 3 5 10 30 50 100 300 500 1,000
Load current (mA)
Residual output voltage (V)
24 VAC
VL
V
~
~
A
30
20
10
0
OFF
ON
1 3 5 10 30 50 100 300 500 1,000
24 VAC
Load current (mA)
Residual
Load
Voltage
Residual output
voltage
Load voltage VL (V)
E2FQ
4
E2FQ-X@Y1 at 100 VAC E2FQ-X@Y1 at 200 VAC
Leakage Current
E2FQ-X@DE2FQ-X@Y
100 VAC
VL
V
~
~
A
120
100
80
60
40
20
0
OFF
ON
1 3 5 10 30 50 100 300
Load current (mA)
Residual
output voltage
Residual
load
voltage
Load voltage VL (V)
200 VAC
VL
V
~
~
A
240
200
160
120
80
40
0
OFF
ON
1 3 5 10 30 50 100 300
Load current (mA)
Residual
output voltage
Residual
load
voltage
Load voltage VL (V)
0 10 20 30 40
1.0
0.8
0.6
0.4
0.2
Power supply voltage (V)
Leakage current (mA)
2.0
1.5
1.0
0 50 100 150 200 250
V
~
mA
~
Power supply voltage (V)
AC
power,
50/60Hz
Protective resistance
Proximity
Sensor
(OFF)
Leakage current (mA)
5
E2FQ
I/O Circuit Diagrams
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the clearances
given in the following table are maintained. Failure to maintain these
distances may cause deterioration in the performance of the Sensor.
Influence of Surrounding Metal (Unit: mm)
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side, ensure
that the minimum distances given in the following table are maintained.
Mounting
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Note: The following torque assume washers are being used.
Miscellaneous
Chemical Resistance
Refer to Chemical Resistance for details.
Operation
mode
Output con-
figuration Model Timing chart Output circuit
NO
NPN
E2FQ-X2E1
E2FQ-X5E1
E2FQ-X10E1
DC 2-wire
E2FQ-X2D1
E2FQ-X5D1
E2FQ-X10D1
AC 2-wire E2FQ-X5Y1
E2FQ-X10Y1
WARNING
H
L
Present
Not present
Operate
Reset
Load
(between brown
and black leads)
(between black and
blue leads)
Output voltage
Sensing object
ON
OFF
Detection indicator
(red)
2.2 Ω
4.7 kΩ
100 Ω
Tr
0 V
+
V
*1
*2
Brown
Black
Output
Blue
Proximity
Sensor
main
circuit
*1. 200 mA max. (load current).
*2. When a transistor is connected.
Load
80 0100
(%)
Sensing
object
Rated
sensing
distance
Stable sensing area
Non-sensing
area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation indicator
(red)
Control output
0 V
+V
Load
Brown
Blue
Proximity
Sensor
main
circuit
Note: The load can be connected to either
the +V or 0 V side.
Operation
indicator (red)
Operate
Reset
ON
OFF
Load
Sensing object
Present
Not present
Load
Brown
Blue
Proximity
Sensor
main
circuit
Precautions for Correct Use
Model Item l d D m n
E2FQ-X2@
0
12
0
818
E2FQ-X5@18 20 27
E2FQ-X10@30 40 45
m
n
m
D
d dia.
Model Torque
E2FQ-X2@0.98 N·m
E2FQ-X5@
2 N·m
E2FQ-X10@
Mutual Interference (Unit: mm)
Model Item A B
E2FQ-X2@30 20
E2FQ-X5@50 35
E2FQ-X10@100 70
A
B
E2FQ
6
Dimensions
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E2FQ-X2E1
24
27
38
17
21 dia.
6
M12 × 1
*
Two toothed washers
Two clamping nuts
Detection indicator (red)
* 6-dia. vinyl-insulated round cable with 3 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X2D1
24
27
38
17
21 dia.
M12 × 16
*
Two toothed washers
Two clamping nuts
Operation indicator (red)
* 6-dia. vinyl-insulated round cable with 2 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X5E1
24 29
32
47
40
29 dia.
M18 × 18
*
Two toothed washers
Two clamping nuts
Detection indicator (red)
* 6-dia. vinyl-insulated round cable with 3 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X5D1
E2FQ-X5Y1
24 29
32
47
40
29 dia.
M18 × 18
*1
Two toothed washers
Two clamping nuts
Indicator *2
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D1: Operation indicator (red) and Setting indicator (green)
Y1: Operation indicator (red)
38
41
50
57
36
42 dia.
M30 × 1.5 8
*
Two toothed washers
Two clamping nuts
Detection indicator (red)
* 6-dia. vinyl-insulated round cable with 3 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X10E1
38
41
50
57
36
42 dia.
M30 × 1.5 8
*1
Two toothed washers
Two clamping nuts
Indicator *2
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D1: Operation indicator (red) and Setting indicator (green)
Y1: Operation indicator (red)
E2FQ-X10D1
E2FQ-X10Y1
Mounting Hole Dimensions
Model F (mm)
E2FQ-X2@12.5 dia.
E2FQ-X5@18.5 dia.
E2FQ-X10@30.5 dia.
+0.5
0
+0.5
0
+0.5
0
F
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E2FQ-X10D1 E2FQ-X10D1-5M E2FQ-X10D1-6T E2FQ-X10D2-6T E2FQ-X10E1 E2FQ-X10E1-5M E2FQ-X10F1
E2FQ-X10Y1 E2FQ-X10Y1-5M E2FQ-X2D1 E2FQ-X2D1-5M E2FQ-X2E1 E2FQ-X2E1-2 5M E2FQ-X2E1-5M
E2FQ-X2F1 E2FQ-X5D1 E2FQ-X5D1-5M E2FQ-X5E1 E2FQ-X5E1-5M E2FQ-X5F1 E2FQ-X5Y1 E2FQ-X5Y1-5M
E2FQ-X7D1-6T