TDK-Lambda RDS100-24 SPECIFICATIONS B029-01-01D MODEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ITEMS Nominal Output Voltage Maximum Output Current Maximum Output Power Efficiency (Typ) Input Voltage Range Input Current (Typ) Inrush Current (Typ) Output Voltage Range Maximum Ripple Maximum Ripple & Noise Maximum Line Regulation Maximum Load Regulation Temperature Coefficient Over Current Protection Over Voltage Protection Remote ON/OFF control Parallel Operation Series Operation Operating Temperature Operating Humidity Storage Temperature Storage Humidity Cooling Withstand Voltage 25 26 Isolation Resistance Vibration - 27 Shock - 28 Safety - 29 30 31 Conducted Emission Radiated Emission Immunity - (*1) (*1) (*1) (*8) (*2) (*2) (*3) (*4) (*5) (*6) (*7) V A W % A V mV mV mV mV A V - RDS100-24-5 RDS100-24-12 RDS100-24-15 RDS100-24-24 5 20 100 78 12 8.3 99.6 15 6.6 99 24 4.2 100.8 80 79 18 - 32VDC 5.4 4.7A at Cold Start 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 50 80 80 100 100 170 200 290 40 96 120 192 50 100 100 200 Less than 0.02 %/ 22 - 24 9.3 - 9.9 7.4 - 7.9 4.7 - 5.1 6.2 - 7.5 15.0 - 18.0 18.5 - 22.5 29.5 - 36.0 Possible Possible -20 - +60C (-20 - +50C:100%, +60C:70%) 20 - 95%RH (No Condensing) -25 - +75C 20 - 95%RH (No Condensing) Convection Cooling I/P - O/P, I/P - FG : 2kVAC (10mA) for 1min., O/P - CNT(RC) : 100VAC (100mA) for 1min. O/P - FG : 500VDC 100Mohm, O/P - CNT(RC) : 100VDC 10Mohm 10 - 55Hz : 19.6m/s 2, X,Y,Z 1hour each. Designed to meet JIS E 3014-2-B 294m/s2 (time : 63ms) Designed to meet JIS E 3015-2-B Approved by UL60950-1 & CSA60950-1, Designed to meet EN60950-1 Designed to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A Designed to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A Designed to meet IEC61000-4-2(Level 2,3), -4(Level 3), -8(Level 4) 32 Weight (Typ) g 850 33 Size (W x H x D) mm 60 x 95 x 220 ( Refer to Outline Drawing ) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. At 24VDC, Ta=25C, nominal output voltage and maximum output power. *2. Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz. *3. 18 - 32VDC, constant load. *4. No load-Full load, constant input voltage. *5. OCP TYPE : Constant current limit with automatic recovery. *6. OVP circuit will shut the output down, manual reset (Re power on). *7. Ratings - Derating at standard mounting. Refer to output derating curve(B029-01-02_). - Load (%) is percent of maximum output power or maximum output current, whichever is greater. *8. At 24VDC Input.(Refer to instruction manual.) TDK-Lambda RDS100-24 OUTPUT DERATING B029-01-02A *COOLING : CONVECTION COOLING LOAD (%) Ta (C) -20 - +40 50 60 MOUNTING A 100 100 70 MOUNTING B 100 70 - OUTPUT DERATING CURVE 120 LOAD (%) 100 80 MOUNTING A 60 MOUNTING B 40 20 0 -20 -10 0 10 20 30 40 50 60 70 Ta (C) DON'T USE MOUNTING A (STANDARD MOUNTING) MOUNTING B MOUNTING C MOUNTING D MOUNTING E Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: RDS1002412