Set your site on VICOR at vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM7B Rev. 1.3 Page 1 of 7
Features
EMI filtering-MIL-STD-461E(1)
Transient protection-MIL-STD-1275A/B/D,
MIL-STD-704A-F and DO-160E
Environments-MIL-STD-810, MIL-STD- 202
Environmental stress screening
Low profile mounting options
Output power up to 400 W
Mini sized package
Inrush current limiting
Product Highlights
The M-FIAM7B is a DC front-end module
that provides EMI filtering and transient
protection. The M-FIAM7B enables designers
using Vicor’s 28 V DC-DC V•I Chip and
VIBRICK modules to meet conducted
emission/ conducted susceptibility per
MIL-STD-461E; and input transients per
MIL-STD-1275A/B/D, MIL-STD-704A-F
and DO-160E. The M-FIAM7B accepts an
input voltage of 14 – 50 Vdc and delivers
output power up to 400 W.
M-FIAM7B is housed in an industry
standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon
model selected, may be mounted onboard
or inboard for height critical applications.
Compatible Products
28 V Input DC-DC V•I Chip or
VIBRICK modules.
Note: This product is not compatible with
Maxi, Mini, Micro DC-DC converters.
(1)EMI performance is subject to a wide
variety of external influences such as PCB
construction, circuit layout etc. As such,
external components in addition to those
listed herein may be required in specific
instances to gain full compliance to the
standards specified.
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
M-FIAM7B M 2 1
Part Numbering*
*Compatible with SurfMate and InMate socketing system.
Product Product Grade Temperatures (°C)
Grade Operating Storage
M= –55 to +100 65 to +125
H= –40 to +100 –55 to +125
Baseplate
1= Slotted
2=Threaded
3=Thru hole
Thermal Resistance and Capacity
Parameter Min Typ Max Unit
Baseplate to sink
flat, greased surface 0.16 °C/Watt
with thermal pad (P/N 20264) 0.1 °C/Watt
Baseplate to ambient
Free convection 7.9 °C/Watt
1000 LFM 2.2 °C/Watt
MTBF per MIL-HDBK-217F (M-FIAM7BM21)
Temperature Environment
MTBF
Unit
25°C Ground Benign: G.B. 4,041 1,000 Hrs
50°C Naval Sheltered: N.S. 727 1,000 Hrs
65°C Airborne Inhabited Cargo: A.I.C. 570 1,000 Hrs
Parameter Rating Unit Notes
+In to –In 50 Vdc Continuous
Mounting torque 5 (0.57) in-lbs6 each, #4-40 or M3
Pin soldering temperature 500 (260) °F(°C) <5 sec; wave solder
750 (390) °F(°C) <7 sec; hand solder
Absolute Maximum Rating
Data Sheet
M-FIAM7B
Military COTS 28 Vin Filter
Input Attenuator Module
Model Number: M-FIAM7BM21*
Pin Style
1= Short Pin
2= Long Pin
S= Short ModuMate*
N= Long ModuMate*
F= Short RoHS
G= Long RoHS
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM7B Rev. 1.3 Page 2 of 7
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Unit Notes
Input voltage 14 28 50 Vdc Continuous
Inrush limiting 0.007 A/µF See Fig. 4
Transient immunity
100 Vdc 50 ms per MIL-STD-1275A/B/D, continuous operation (see Fig. 3)
250 Vdc 70 µs per MIL-STD-1275B, continuous operation
70 Vdc 20 ms per MIL-STD-704A, continuous operation
80 Vdc 100 ms per DO-160E, Section 16, Power Input, Category Z
50 ms per MIL-STD-704A, continuous operation
INPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Output current 25 A Over continuous input and temp. range
Output power 400 W Transient compliance over temp. range (see Fig.7)
Efficiency 96 98 %
Internal voltage drop 0.5 0.7 @25 A, 100°C baseplate
External capacitance See Figure 8
330 3300 µF 63 V
OUTPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
ON/OFF control
Enable (ON) 0.0 1.0 Vdc Referenced to – Vout
Disable (OFF) 4.0 5.50 Vdc 100 kΩinternal pull-up resistor
EMI GRD earth Not electrically connected to baseplate
CONTROL PIN SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Dielectric withstand 1,500 Vrms Input/Output to Base
2,121 Vdc Input/Output to Base
SAFETY SPECIFICATIONS
SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
Standard Test Procedure Notes
MIL-STD-461E
Conducted emissions: CE101, CE102
Conducted susceptibility: CS101 (see note), CS114, CS115, CS116 With suggested Reverse Polarity Protection
EMI
Parameter Min Typ Max Unit Notes
Weight 3.3 (94) Ounces (grams)
Warranty 2 Years
GENERAL SPECIFICATIONS
EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components
in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified.
Set your site on VICOR at vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM7B Rev. 1.3 Page 3 of 7
SPECIFICATIONS (CONT.)
ENVIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17
with overall level of 7.7 G rms for 1 hour per axis.
Shock
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 g, 9ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
Parameter H-Grade M-Grade
Operating temperature -40°C to +100°C -55°C to +100°C
Storage temperature -55°C to +125°C -65°C to +125°C
Temperature cycling* 12 cycles 12 cycles
-65°C to +100°C -65°C to +100°C
Ambient test @ 25°C Yes Yes
Power cycling burn-in 12 hours, 29 cycles 24 hours, 58 cycles
Functional and parametric ATE tests -40°C and +100°C -55°C and +100°C
Hi-Pot test Yes Yes
Visual inspection Yes Yes
Test datavicorpower.com vicorpower.com
ENVIRONMENTAL STRESS SCREENING
Figure 2 – MIL-STD-461F, CE102; M-FIAM7B and three
MIL-COTS PRMs and three MIL-COTS VTMs, 350 W
Shut Down Time vs. Overvoltage
T (ms)
Vin (V)
0
100
200
300
400
500
600
700
800
900
60 70 80 90 100 105
Figure 1 T = Time period before over-voltage protection. Vin
= Input voltage (switching up from 28 Vdc)
*Temperature cycled with power off, 17°C per minute rate of change.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM7B Rev. 1.3 Page 4 of 7
Set your site on VICOR at vicorpower.com
Figure 3 – Transient Immunity; M-FIAM7B output response to an input transient
Figure 4 Inrush Limiting; Inrush current with
3300
μF external capacitance
Figure 5 Insertion Loss Curve
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
10
0.01 0.10 1.00 10.00
Frequency [MHz]
Differential Mode (DM) and Common Mode (CM) IL
DM IL CM IL
IL [dB]
Set your site on VICOR at vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM7B Rev. 1.3 Page 5 of 7
EMI
GND
NC
++
NC
NC
ON
OFF
C1
M-FIAM7B +Out
–Out
+In
–In
PRM-AL
-In
+In
-Out
+Out
VTM
+Out
-Out
K
Ro
Transorb
P/N
19180-510
C
C
C
C
F1
Component Suggestions
Recommended Fuse: (F1) 30 A (max), Bussmann ABC style/Littlefuse nano 2, 40A (max)
Capacitance: (C1) 330 µF (min), 3300 µF (max); (C) 4700 pF
Input
Figure 8 – Basic connection diagram with suggested Transient, Surge Protection and Reverse Polarity Protection (R.P.P)
Figure 6 – M-FIAM7B EMI Compliance only
0
M-FIAM7B EMI Compliance Only
Output Power (W)
Input Voltage (VDC)
5 1014 20253035404550
1500
1250
1000
750
500
250
Safe Operating
Area
350
Figure 7 M-FIAM7B EMI and MIL-STD-1275D Transient Compliance
0
M-FIAM7B EMI and MIL-STD-1275D
Transient Compliance
Output Power (W)
Input Voltage (VDC)
425
400
375
350
325
Safe Operating
Area
010 2030405060708090100 110
14
(Normal Operation) (Transient 50 mS max.)
16
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM7B Rev. 1.3 Page 6 of 7
Set your site on VICOR at vicorpower.com
0.195
4,95
1.400*
35,56
1.000*
25,40
0.700*
17,78
0.400*
10,16
1.790**
45,47
0.06
1,5
R (4X) 0.158
4,01
56789
12 34
±0.003
±0,08
* DENOTES TOL =
PCB THICKNESS 0.062 ±0.010
1,57 ±0,25
SHORT PIN STYLE
0.094 ±0.003
2,39 ±0,08
INBOARD
SOLDER
MOUNT
0.43
10,9
0.53
13,5
1.900*
48.26
1.900*
48,26
1.575**
40,00
0.164 ±0.003
4,16 ±0,08
LONG PIN STYLE
0.094 ±0.003
2,39 ±0,08
ONBOARD
SOLDER
MOUNT
0.164 ±0.003
4,16 ±0,08
PLATED
THROUGH HOLE
DIA
(7X)
(2X)
** PCB WINDOW
ALL MARKINGS
THIS SURFACE
PINS STYLES
SOLDER:TIN / LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
ALUMINUM
BASEPLATE
Module Pins
No. Function Label
1+In +
2No NC
Connection
3 Ground EMI/GND
4–In
5–Out–
6 ON/OFF ON/OFF
7No NC
Connection
8No NC
Connection
9+Out+
MECHANICAL DRAWINGS
Figure 9 Mechanical diagram
Figure 10 PCB Mounting Specifications
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM7B Rev. 1.3 1/2012
Set your site on VICOR at vicorpower.com
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR
DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com