Agilent HCPL-316J 2.5 Amp Gate Drive Optocoupler with Integrated (VCE) Desaturation Detection and Fault Status Feedback Data Sheet Features * 2.5 A maximum peak output current * Drive IGBTs up to IC = 150 A, VCE = 1200 V * Optically isolated, FAULT status feedback * SO-16 package * CMOS/TTL compatible * 500 ns max. switching speeds * "Soft" IGBT turn-off * Integrated fail-safe IGBT protection - Desat (VCE) detection - Under Voltage Lock-Out protection (UVLO) with hysteresis * User configurable: inverting, noninverting, auto-reset, autoshutdown * Wide operating VCC range: 15 to 30 Volts * -40C to +100C operating temperature range * 15 kV/s min. Common Mode Rejection (CMR) at VCM = 1500 V * Regulatory approvals: UL, CSA, IEC/EN/DIN EN 60747-5-2 (891 Vpeak Working Voltage) Fault Protected IGBT Gate Drive +HV ISOLATION BOUNDARY ISOLATION BOUNDARY ISOLATION BOUNDARY HCPL - 316J HCPL - 316J HCPL - 316J 3-PHASE INPUT M HCPL - 316J HCPL - 316J ISOLATION BOUNDARY HCPL - 316J ISOLATION BOUNDARY ISOLATION BOUNDARY HCPL - 316J ISOLATION BOUNDARY -HV FAULT MICRO-CONTROLLER Agilent's 2.5 Amp Gate Drive Optocoupler with Integrated Desaturation (VCE) Detection and Fault Status Feedback makes IGBT VCE fault protection compact, affordable, and easy-to-implement while satisfying worldwide safety and regulatory requirements. CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD. Typical Fault Protected IGBT Gate Drive Circuit The HCPL-316J is an easy-touse, intelligent gate driver which makes IGBT VCE fault protection compact, affordable, and easyto-implement. Features such as user configurable inputs, integrated VCE detection, under voltage lockout (UVLO), "soft" IGBT turn-off and isolated fault feedback provide maximum design flexibility and circuit protection. HCPL-316J 1 VIN+ VE 16 2 VIN- VLED2+ 15 3 VCC1 DESAT 14 4 GND1 VCC2 13 5 RESET VC 12 6 FAULT VOUT 11 7 VLED1+ VEE 10 8 VLED1- VEE 9 * CBLANK 100 + - C RF DDESAT + + - * VF - + RG VCE - + * - + RPULL-DOWN VCE - * THESE COMPONENTS ARE ONLY REQUIRED WHEN NEGATIVE GATE DRIVE IS IMPLEMENTED. Figure 1. Typical desaturation protected gate drive circuit, noninverting. Description of Operation during Fault Condition 1. DESAT terminal monitors the IGBT VCE voltage through DDESAT. 2. When the voltage on the DESAT terminal exceeds 7 volts, the IGBT gate voltage (VOUT) is slowly lowered. 3. FAULT output goes low, notifying the microcontroller of the fault condition. 4. Microcontroller takes appropriate action. Output Control The outputs (VOUT and FAULT) of the HCPL-316J are controlled by the combination of VIN, UVLO and a detected IGBT Desat condition. As indicated in the below table, the HCPL-316J can 2 be configured as inverting or non-inverting using the VIN+ or VIN- inputs respectively. When an inverting configuration is desired, VIN+ must be held high and VIN- toggled. When a non-inverting configuration is desired, VIN- must be held low and VIN+ toggled. Once UVLO is not active (VCC2 - VE > VUVLO), VOUT is allowed to go high, and VIN+ X X Low X High VINX X X High Low UVLO (VCC2 - VE) Active X X X Not Active the DESAT (pin 14) detection feature of the HCPL-316J will be the primary source of IGBT protection. UVLO is needed to ensure DESAT is functional. Once VUVLO+ > 11.6 V, DESAT will remain functional until VUVLO- < 12.4 V. Thus, the DESAT detection and UVLO features of the HCPL-316J work in conjunction to ensure constant IGBT protection. Desat Condition Detected on Pin 14 X Yes X X No Pin 6 (FAULT) Output X Low X X High VOUT Low Low Low Low High Product Overview Description The HCPL-316J is a highly integrated power control device that incorporates all the necessary components for a complete, isolated IGBT gate drive circuit with fault protection and feedback into one SO-16 package. TTL input logic levels allow direct interface with a microcontroller, and an optically isolated power output stage drives IGBTs with power ratings of up to 150 A and 1200 V. A high speed internal optical link minimizes the propagation delays between the microcontroller and the IGBT while allowing the two systems to operate at very large common mode voltage differences that are common in industrial motor drives and other power switching applications. An output IC provides local VLED1+ protection for the IGBT to prevent damage during overcurrents, and a second optical link provides a fully isolated fault status feedback signal for the microcontroller. A built in "watchdog" circuit monitors the power stage supply voltage to prevent IGBT caused by insufficient gate drive voltages. This integrated IGBT gate driver is designed to increase the performance and reliability of a motor drive without the cost, size, and complexity of a discrete design. Two light emitting diodes and two integrated circuits housed in the same SO-16 package provide the input control circuitry, the output power stage, and two optical channels. The input Buffer IC is designed on a bipolar process, while the VLED1- 7 8 13 INPUT IC VIN+ VIN- 12 1 LED1 2 D R I V E R UVLO 11 14 VCC1 DESAT SHIELD LED2 16 5 FAULT 6 SHIELD OUTPUT IC 4 GND1 3 VOUT DESAT Under normal operation, the input gate control signal directly controls the IGBT gate through the isolated output detector IC. LED2 remains off and a fault latch in the input buffer IC is disabled. When an IGBT fault is detected, the output detector IC immediately begins a "soft" shutdown sequence, reducing the IGBT current to zero in a controlled manner to avoid potential IGBT damage from inductive overvoltages. Simultaneously, this fault status is transmitted back to the input buffer IC via LED2, where the fault latch disables the gate control input and the active low fault output alerts the microcontroller. 3 9,10 RESET FAULT VCC2 VC output Detector IC is designed manufactured on a high voltage BiCMOS/Power DMOS process. The forward optical signal path, as indicated by LED1, transmits the gate control signal. The return optical signal path, as indicated by LED2, transmits the fault status feedback signal. Both optical channels are completely controlled by the input and output ICs respectively, making the internal isolation boundary transparent to the microcontroller. 15 VLED2+ VEE VE During power-up, the Under Voltage Lockout (UVLO) feature prevents the application of insufficient gate voltage to the IGBT, by forcing the HCPL-316J's output low. Once the output is in the high state, the DESAT (VCE) detection feature of the HCPL-316J provides IGBT protection. Thus, UVLO and DESAT work in conjunction to provide constant IGBT protection. Package Pin Out 1 VIN+ VE 16 2 VIN- VLED2+ 15 3 VCC1 DESAT 14 4 GND1 VCC2 13 5 RESET VC 12 6 FAULT VOUT 11 7 VLED1+ VEE 10 8 VLED1- VEE 9 Pin Descriptions Symbol Description VIN+ Noninverting gate drive voltage output (VOUT) control input. VINInverting gate drive voltage output (VOUT) control input. Symbol VE Description Common (IGBT emitter) output supply voltage. VLED2+ LED 2 anode. This pin must be left unconnected for guaranteed data sheet performance. (For optical coupling testing only.) Desaturation voltage input. When the voltage on DESAT exceeds an internal reference voltage of 7 V while the IGBT is on, FAULT output is changed from a high impedance state to a logic low state within 5 s. See Note 25. Positive output supply voltage. Collector of output pull-up triple-darlington transistor. It is connected to VCC2 directly or through a resistor to limit output turn-on current. VCC1 Positive input supply voltage. (4.5 V to 5.5 V) DESAT GND1 RESET Input Ground. FAULT reset input. A logic low input for at least 0.1 s, asynchronously resets FAULT output high and enables VIN. Synchronous control of RESET relative to VIN is required. RESET is not affected by UVLO. Asserting RESET while VOUT is high does not affect VOUT. Fault output. FAULT changes from a high impedance state to a logic low output within 5 s of the voltage on the DESAT pin exceeding an internal reference voltage of 7 V. FAULT output remains low until RESET is brought low. FAULT output is an open collector which allows the FAULT outputs from all HCPL-316Js in a circuit to be connected together in a "wired OR" forming a single fault bus for interfacing directly to the micro-controller. LED 1 anode. This pin must be left unconnected for guaranteed data sheet performance. (For optical coupling testing only.) LED 1 cathode. This pin must be connected to ground. VCC2 VC FAULT VLED1+ VLED1- 4 VOUT Gate drive voltage output. VEE Output supply voltage. Ordering Information Specify Part Number followed by Option Number (if desired). Example: HCPL-316J#XXXX No Option = 16-Lead, Surface Mt. package, 45 per tube. 500 = Tape and Reel Packaging Option, 850 per reel. XXXE = Lead Free Option. Remarks: The notation "#" is used for existing products, while (new) products launched since 15th July 2001 and lead free option will use "-" Option data sheets available. Contact Agilent sales representative, authorized distributor, or visit our WEB site at http://www.agilent.com/view/optocouplers. Package Outline Drawings 16-Lead Surface Mount Dimensions in inches (millimeters) Notes: Initial and continued variation in the color of the HCPL-316J's white mold compound is normal and does note affect device performance or reliability. 0.018 (0.457) 0.050 (1.270) LAND PATTERN RECOMMENDATION 16 15 14 13 12 11 10 9 TYPE NUMBER DATE CODE A 316J YYWW 0.458 (11.63) 0.295 0.010 (7.493 0.254) 0.085 (2.16) 1 2 3 4 5 6 7 8 0.406 0.10 (10.312 0.254) 0.025 (0.64) 0.345 0.010 (8.986 0.254) 9 Floating Lead Protrusion is 0.25 mm (10 mils) max. 0.018 (0.457) 0.138 0.005 (3.505 0.127) 0-8 0.025 MIN. 0.408 0.010 (10.160 0.254) ALL LEADS TO BE COPLANAR 0.002 0.008 0.003 (0.203 0.076) STANDOFF Package Characteristics All specifications and figures are at the nominal (typical) operating conditions of VCC1 = 5 V, VCC2 - VEE = 30 V, VE - VEE = 0 V, and TA = +25C. Parameter Input-Output Momentary Withstand Voltage Resistance (Input-Output) Capacitance (Input-Output) Output IC-to-Pins 9 &10 Thermal Resistance Input IC-to-Pin 4 Thermal Resistance 5 Symbol VISO Min. 3750 Typ. RI-O CI-O qO9-10 >109 1.3 30 qI4 60 Max. Units Vrms pF C/W Test Conditions RH < 50%, t = 1 min., TA = 25C VI-O = 500 Vdc f = 1 MHz TA = 100C Note 1, 2, 3 3 Solder Reflow Thermal Profile 300 TEMPERATURE (C) PREHEATING RATE 3C + 1C/-0.5C/SEC. REFLOW HEATING RATE 2.5C 0.5C/SEC. PEAK TEMP. 245C PEAK TEMP. 240C PEAK TEMP. 230C 200 2.5C 0.5C/SEC. SOLDERING TIME 200C 30 SEC. 160C 150C 140C 30 SEC. 3C + 1C/-0.5C 100 PREHEATING TIME 150C, 90 + 30 SEC. 50 SEC. TIGHT TYPICAL LOOSE ROOM TEMPERATURE 0 0 50 100 150 200 TIME (SECONDS) Recommended Pb-Free IR Profile tp Tp TEMPERATURE TL Tsmax TIME WITHIN 5 C of ACTUAL PEAK TEMPERATURE 20-40 SEC. 260 +0/-5 C 217 C RAMP-UP 3 C/SEC. MAX. 150 - 200 C RAMP-DOWN 6 C/SEC. MAX. Tsmin ts PREHEAT 60 to 180 SEC. tL 60 to 150 SEC. 25 t 25 C to PEAK TIME NOTES: THE TIME FROM 25 C to PEAK TEMPERATURE = 8 MINUTES MAX. Tsmax = 200 C, Tsmin = 150 C 6 250 Regulatory Information The HCPL-316J has been approved by the following organizations: IEC/EN/DIN EN 60747-5-2 Approved under: IEC 60747-5-2:1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01. UL Recognized under UL 1577, component recognition program, File E55361. CSA Approved under CSA Component Acceptance Notice #5, File CA 88324. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage 150 Vrms for rated mains voltage 300 Vrms for rated mains voltage 600 Vrms Climatic Classification Pollution Degree (DIN VDE 0110/1.89) Maximum Working Insulation Voltage Input to Output Test Voltage, Method b** VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial Discharge < 5 pC Input to Output Test Voltage, Method a** VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec, Partial Discharge < 5 pC Highest Allowable Overvoltage** (Transient Overvoltage tini = 10 sec) Safety-limiting values - maximum values allowed in the event of a failure, also see Figure 2. Case Temperature Input Power Output Power Insulation Resistance at TS, VIO = 500 V Symbol Characteristic Unit VIORM I - IV I - III I - II 55/100/21 2 891 VPEAK VPR 1670 VPEAK VPR 1336 VPEAK VIOTM 6000 VPEAK TS PS, INPUT PS, OUTPUT RS 175 400 1200 >109 C mW mW *Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application. Surface mount classification is class A in accordance with CECCOO802. **Refer to the optocoupler section of the Isolation and Control Components Designer's Catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles. 1400 PS, OUTPUT PS, INPUT PS - POWER - mW 1200 1000 800 600 400 200 0 0 25 50 75 100 125 150 175 200 TS - CASE TEMPERATURE - C Figure 2. Dependence of safety limiting values on temperature. 7 Insulation and Safety Related Specifications Parameter Minimum External Air Gap (Clearance) Minimum External Tracking (Creepage) Minimum Internal Plastic Gap (Internal Clearance) Symbol L(101) Value 8.3 Units mm L(102) 8.3 mm 0.5 mm Tracking Resistance (Comparative Tracking Index) Isolation Group CTI >175 Volts IIIa Conditions Measured from input terminals to output terminals, shortest distance through air. Measured from input terminals to output terminals, shortest distance path along body. Through insulation distance conductor to conductor, usually the straight line distance thickness between the emitter and detector. DIN IEC 112/VDE 0303 Part 1 Material Group (DIN VDE 0110, 1/89, Table 1) Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature Output IC Junction Temperature Peak Output Current Fault Output Current Positive Input Supply Voltage Input Pin Voltages Total Output Supply Voltage Negative Output Supply Voltage Positive Output Supply Voltage Gate Drive Output Voltage Collector Voltage DESAT Voltage Output IC Power Dissipation Input IC Power Dissipation Solder Reflow Temperature Profile Symbol Min. -55 -40 Max. Ts 125 TA 100 TJ 125 |Io(peak)| 2.5 IFAULT 8.0 VCC1 -0.5 5.5 VIN+, VIN- and VRESET -0.5 VCC1 (VCC2 - VEE) -0.5 35 (VE - VEE) -0.5 15 (VCC2 - VE) -0.5 35 - (VE - VEE) Vo(peak) -0.5 VCC2 VC VEE + 5 V VCC2 VDESAT VE VE + 10 PO 600 PI 150 See Package Outline Drawings section Units C A mA Volts Note 4 5 6 mW 4 Recommended Operating Conditions Parameter Operating Temperature Input Supply Voltage Total Output Supply Voltage Negative Output Supply Voltage Positive Output Supply Voltage Collector Voltage 8 Symbol TA VCC1 (VCC2 - VEE) (VE - VEE) (VCC2 - VE) VC Min. -40 4.5 15 0 15 VEE + 6 Max. +100 5.5 30 15 30 - (VE - VEE) VCC2 Units C Volts Note 28 9 6 Electrical Specifications (DC) Unless otherwise noted, all typical values at TA = 25C, VCC1 = 5 V, and VCC2 - VEE = 30 V, VE - VEE = 0 V; all Minimum/Maximum specifications are at Recommended Operating Conditions. Parameter Symbol Min. Typ. Max. Units Test Conditions Logic Low Input Voltages VIN+L, VIN-L, 0.8 V VRESETL Logic High Input Voltages VIN+H, VIN-H, 2.0 VRESETH Logic Low Input Currents IIN+L, IIN-L, -0.5 -0.4 mA VIN = 0.4 V IRESETL FAULT Logic Low Output IFAULTL 5.0 12 VFAULT = 0.4 V Current FAULT Logic High Output IFAULTH -40 A VFAULT = VCC1 Current High Level Output Current IOH -0.5 -1.5 A VOUT = VCC2 - 4 V -2.0 VOUT = VCC2 - 15 V Low Level Output Current IOL 0.5 2.3 VOUT = VEE + 2.5 V 2.0 VOUT = VEE + 15 V Low Level Output Current IOLF 90 160 230 mA VOUT - VEE = 14 V During Fault Condition High Level Output Voltage VOH VC - 3.5 VC - 2.5 VC - 1.5 V IOUT = -100 mA VC -2.9 VC - 2.0 VC - 1.2 IOUT = -650 A VC IOUT = 0 Low Level Output Voltage VOL 0.17 0.5 IOUT = 100 mA High Level Input Supply Current Low Level Input Supply Current Output Supply Current ICC1H 17 22 ICCIL 6 11 ICC2 2.5 5 1.0 1.3 3.0 0 Low Level Collector Current ICL High Level Collector Current ICH VE Low Level Supply Current VE High Level Supply Current Blanking Capacitor Charging Current IEL -0.7 0.3 0.3 1.8 -0.4 IEH -0.5 -0.14 0 ICHG -0.13 -0.18 -0.25 -0.25 -0.33 -0.33 Blanking Capacitor Discharge Current UVLO Threshold IDSCHG 10 50 VUVLO+ VUVLO(VUVLO+ VUVLO-) VDESAT 11.6 13.5 12.4 0.4 12.3 11.1 1.2 6.5 7.0 7.5 UVLO Hysteresis DESAT Threshold 9 mA Fig. Note 30 31 3, 8, 32 4, 9, 33 5, 34 6, 8, 35 7 5 7 5 8 9, 10, 11 7, 9, 26 36 VIN+ = VCC1 = 5.5 V, 10, 37 VIN- = 0 V 38 VIN+ = VIN- = 0 V, VCC1 = 5.5 V VOUT open 11, 12, 11 39, 40 IOUT = 0 15, 59 27 IOUT = 0 15, 58 27 IOUT = -650 A 15, 57 14, 61 14, 40 25 VDESAT = 0 - 6 V VDESAT = 0 - 6 V, TA = 25C - 100C VDESAT = 7 V V 13, 41 11, 12 42 VOUT > 5 V VOUT < 5 V 43 9, 11, 13 9, 11, 14 VCC2 - VE > VUVLO- 16, 44 11 Switching Specifications (AC) Unless otherwise noted, all typical values at TA = 25C, VCC1 = 5 V, and VCC2 - VEE = 30 V, VE - VEE = 0 V; all Minimum/Maximum specifications are at Recommended Operating Conditions. Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note VIN to High Level Output tPLH 0.10 0.30 0.50 s Rg = 10 17,18,19, 15 Propagation Delay Time Cg = 10 nF, 20,21,22, f = 10 kHz, 45,54,55 VIN to Low Level Output tPHL 0.10 0.32 0.50 Duty Cycle = 50% Propagation Delay Time Pulse Width Distortion Propagation Delay Difference Between Any Two Parts 10% to 90% Rise Time 90% to 10% Fall Time DESAT Sense to 90% VOUT Delay PWD (tPHL - tPLH) PDD tr tf tDESAT(90%) DESAT Sense to 10% VOUT Delay DESAT Sense to Low Level FAULT Signal Delay DESAT Sense to DESAT Low Propagation Delay RESET to High Level FAULT Signal Delay RESET Signal Pulse Width UVLO to VOUT High Delay UVLO to VOUT Low Delay Output High Level Common Mode Transient Immunity Output Low Level Common Mode Transient Immunity 10 -0.30 -0.35 0.02 0.30 0.35 0.1 0.1 0.3 0.5 tDESAT(10%) 2.0 3.0 tDESAT(FAULT) 1.8 5 tDESAT(LOW) 0.25 tRESET(FAULT) 3 7 PWRESET tUVLO ON tUVLO OFF |CMH| 0.1 15 4.0 6.0 30 |CML| 15 30 16,17 17,18 45 Rg = 10 , Cg = 10 nF VCC2 - VEE = 30 V 20 VCC2 = 1.0 ms ramp kV/s TA = 25C, VCM = 1500 V, VCC2 = 30 V TA = 25C, VCM = 1500 V, VCC2 = 30 V 23,56 19 24,28, 46,56 25,47, 56 56 20 21 26,27, 56 22 49 13 14 23 50,51, 52,53 24 Notes: 1. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage 4500 Vrms for 1 second (leakage detection current limit, II-O 5 A). This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/ DIN EN 60747-5-2 Insulation Characteristic Table, if applicable. 2. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an inputoutput continuous voltage rating. For the continuous voltage rating refer to your equipment level safety specification or IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table. 3. Device considered a two terminal device: pins 1 - 8 shorted together and pins 9 - 16 shorted together. 4. In order to achieve the absolute maximum power dissipation specified, pins 4, 9, and 10 require ground plane connections and may require airflow. See the Thermal Model section in the application notes at the end of this data sheet for details on how to estimate junction temperature and power dissipation. In most cases the absolute maximum output IC junction temperature is the limiting factor. The actual power dissipation achievable will depend on the application environment (PCB Layout, air flow, part placement, etc.). See the Recommended PCB Layout section in the application notes for layout considerations. Output IC power dissipation is derated linearly at 10 mW/C above 90C. Input IC power dissipation does not require derating. 5. Maximum pulse width = 10 s, maximum duty cycle = 0.2%. This value is intended to allow for component tolerances for designs with IO peak minimum = 2.0 A. See Applications section for additional details on IOH peak. Derate linearly from 3.0 A at +25C to 2.5 A at +100C. This compensates for increased IOPEAK due to changes in VOL over temperature. 6. This supply is optional. Required only when negative gate drive is implemented. 11 7. Maximum pulse width = 50 s, maximum duty cycle = 0.5%. 8. See the Slow IGBT Gate Discharge During Fault Condition section in the applications notes at the end of this data sheet for further details. 9. 15 V is the recommended minimum operating positive supply voltage (VCC2 VE) to ensure adequate margin in excess of the maximum VUVLO+ threshold of 13.5 V. For High Level Output Voltage testing, VOH is measured with a dc load current. When driving capacitive loads, VOH will approach VCC as IOH approaches zero units. 10. Maximum pulse width = 1.0 ms, maximum duty cycle = 20%. 11. Once VOUT of the HCPL-316J is allowed to go high (VCC2 - VE > VUVLO), the DESAT detection feature of the HCPL-316J will be the primary source of IGBT protection. UVLO is needed to ensure DESAT is functional. Once VUVLO+ > 11.6 V, DESAT will remain functional until VUVLO- < 12.4 V. Thus, the DESAT detection and UVLO features of the HCPL-316J work in conjunction to ensure constant IGBT protection. 12. See the Blanking Time Control section in the applications notes at the end of this data sheet for further details. 13. This is the "increasing" (i.e. turn-on or "positive going" direction) of VCC2 - VE. 14. This is the "decreasing" (i.e. turn-off or "negative going" direction) of VCC2 - VE. 15. This load condition approximates the gate load of a 1200 V/75A IGBT. 16. Pulse Width Distortion (PWD) is defined as |tPHL - tPLH| for any given unit. 17. As measured from VIN+, VIN- to VOUT. 18. The difference between tPHL and tPLH between any two HCPL-316J parts under the same test conditions. 19. Supply Voltage Dependent. 20. This is the amount of time from when the DESAT threshold is exceeded, until the FAULT output goes low. 21. This is the amount of time the DESAT threshold must be exceeded before VOUT begins to go low, and the FAULT output to go low. 22. This is the amount of time from when RESET is asserted low, until FAULT output goes high. The minimum specification of 3 s is the guaranteed minimum FAULT signal pulse width when the HCPL-316J is configured for Auto-Reset. See the AutoReset section in the applications notes at the end of this data sheet for further details. 23. Common mode transient immunity in the high state is the maximum tolerable dVCM/dt of the common mode pulse, VCM, to assure that the output will remain in the high state (i.e., VO > 15 V or FAULT > 2 V). A 100 pF and a 3K pull-up resistor is needed in fault detection mode. 24. Common mode transient immunity in the low state is the maximum tolerable dVCM/ dt of the common mode pulse, VCM, to assure that the output will remain in a low state (i.e., VO < 1.0 V or FAULT < 0.8 V). 25. Does not include LED2 current during fault or blanking capacitor discharge current. 26. To clamp the output voltage at VCC - 3 VBE, a pull-down resistor between the output and VEE is recommended to sink a static current of 650 A while the output is high. See the Output Pull-Down Resistor section in the application notes at the end of this data sheet if an output pull-down resistor is not used. 27. The recommended output pull-down resistor between VOUT and VEE does not contribute any output current when VOUT = VEE. 28. In most applications VCC1 will be powered up first (before VCC2) and powered down last (after VCC2). This is desirable for maintaining control of the IGBT gate. In applications where VCC2 is powered up first, it is important to ensure that Vin+ remains low until VCC1 reaches the proper operating voltage (minimum 4.5 V) to avoid any momentary instability at the output during VCC1 ramp-up or ramp-down. 7 IOL - OUTPUT LOW CURRENT 1.8 1.6 1.4 1.2 1.0 -40 -20 0 20 40 60 80 6 5 VOUT = VEE + 15 V VOUT = VEE + 2.5 V 4 3 2 1 0 -40 -20 100 60 40 80 100 -1 -2 -3 20 40 60 80 0.20 IOUT = 100 mA 0.15 0.10 0.05 0 -40 -20 100 Figure 6. VOH vs. temperature. 0 20 40 60 80 100 ICC1 - SUPPLY CURRENT - mA 4 3 2 1 0.5 1.0 1.5 2.0 IOL - OUTPUT LOW CURRENT - A Figure 9: VOL vs. IOL. 50 25 2.5 0 5 10 15 20 25 30 15 ICC1H ICC1L 10 5 0 -40 -20 0 20 40 60 80 TA - TEMPERATURE - C Figure 10. ICC1 vs. temperature. +100C +25C -40C 28.8 28.6 28.4 28.2 28.0 27.8 27.6 27.4 0 0.2 0.4 0.8 0.6 1.0 Figure 8. VOH vs. IOH. 20 +100C +25C -40C -40C 25C 100C 75 IOH - OUTPUT HIGH CURRENT - A Figure 7. VOL vs. temperature. 6 0 0.1 100 TA - TEMPERATURE - C TA - TEMPERATURE - C 5 125 29.0 VOH - OUTPUT HIGH VOLTAGE - V IOUT = -650 A IOUT = -100 mA 0 150 Figure 5. IOLF vs. VOUT. 0.25 0 -4 -40 -20 175 VOUT - OUTPUT VOLTAGE - V Figure 4. IOL vs. temperature. VOL - OUTPUT LOW VOLTAGE - V (VOH -VCC) - HIGH OUTPUT VOLTAGE DROP - V Figure 3. IOH vs. temperature. VOL - OUTPUT LOW VOLTAGE - V 20 200 TA - TEMPERATURE - C TA - TEMPERATURE - C 12 0 100 ICC2 - OUTPUT SUPPLY CURRENT - mA IOH - OUTPUT HIGH CURRENT - A 2.0 IOLF - LOW LEVEL OUTPUT CURRENT DURING FAULT CONDITION - mA Performance Plots 2.6 2.5 2.4 ICC2H ICC2L 2.3 2.2 -40 -20 0 20 40 60 80 TA - TEMPERATURE - C Figure 11: ICC2 vs. t emperature. 100 -0.15 2.55 2.50 2.45 ICC2H ICC2L 2.40 2.35 15 20 25 0.50 IE -VE SUPPLY CURRENT - mA ICHG - BLANKING CAPACITOR CHARGING CURRENT - mA -0.20 -0.25 -0.30 -40 -20 30 80 -40C +25C +100C 0 0.5 1.0 1.5 2.0 0.35 6.5 6.0 -40 -20 0 20 40 60 80 PROPAGATION DELAY - s 0.35 0.30 0.25 25 VCC - SUPPLY VOLTAGE - V Figure 18. Propagation delay vs. supply voltage. 30 0.40 60 80 100 0.4 0.3 0 20 40 60 80 100 TA - TEMPERATURE - C Figure 17. Propagation delay vs. temperature. 0.50 VCC1 = 5.5 V VCC1 = 5.0 V VCC1 = 4.5 V 0.35 0.30 0.25 -50 40 tPHL tPLH 0.2 -40 -20 100 0.45 tPHL tPLH 20 0.5 Figure 16. DESAT threshold vs. temperature. 0.40 0 Figure 14. IE vs. temperature. TA - TEMPERATURE - C Figure 15. IC vs. IOUT. 20 0.40 TA - TEMPERATURE - C 7.0 IOUT (mA) 0.20 15 0.45 0.30 -40 -20 100 TP - PROPAGATION DELAY - s VDESAT - DESAT THRESHOLD - V IC (mA) 2 1 TP - PROPAGATION DELAY - s 60 7.5 3 13 40 Figure 13. ICHG vs. temperature. 4 0 20 IEH IEL TA - TEMPERATURE - C VCC2 - OUTPUT SUPPLY VOLTAGE - V Figure 12. ICC2 vs. VCC2. 0 PROPAGATION DELAY - s ICC2 - OUTPUT SUPPLY CURRENT - mA 2.60 0 50 100 TEMPERATURE - C Figure 19. VIN to high propagation delay vs. temperature. 0.45 VCC1 = 5.5 V VCC1 = 5.0 V VCC1 = 4.5 V 0.40 0.35 0.30 0.25 -50 0 50 TEMPERATURE - C Figure 20. VIN to low propagation delay vs. temperature. 100 0.40 0.45 0.40 tPLH tPHL tPLH tPHL 0.25 DELAY - s 0.30 0.30 0 20 60 40 80 0.20 100 0 10 30 20 40 0.25 -50 50 LOAD RESISTANCE - LOAD CAPACITANCE - nF Figure 21. Propagation delay vs. load capacitance. 2.4 DELAY - s 2.5 2.0 100 50 Figure 23. DESAT sense to 90% Vout delay vs. temperature. 0.008 2.6 VCC2 = 15 V VCC2 = 30 V 0 TEMPERATURE - C Figure 22. Propagation delay vs. load resistance. 3.0 DELAY - s 0.35 0.30 0.25 VEE = 0 V VEE = -5 V VEE = -10 V VEE = -15 V VCC2 = 15 V VCC2 = 30 V 0.006 DELAY - ms 0.20 0.40 0.35 DELAY - s DELAY - s 0.35 2.2 2.0 1.5 0.004 0.002 1.8 1.0 -50 0 50 0 1.6 -50 100 TEMPERATURE - C 0 VCC1 = 5.5 V VCC1 = 5.0 V VCC1 = 4.5 V 10 DELAY - s DELAY - s 0.0025 0.0020 8 6 0.0015 20 30 40 LOAD RESISTANCE - Figure 27. DESAT sense to 10% Vout delay vs. load resistance. 50 4 -50 0 50 100 10 20 30 40 50 Figure 26. DESAT sense to 10% Vout delay vs. load capacitance. 12 VCC2 = 15 V VCC2 = 30 V 0 LOAD CAPACITANCE - nF Figure 25. DESAT sense to low level fault signal delay vs. temperature. 0.0030 14 100 TEMPERATURE - C Figure 24. DESAT sense to 10% Vout delay vs. temperature. 0.0010 10 50 150 TEMPERATURE - C Figure 28. RESET to high level fault signal delay vs. temperature. Test Circuit Diagrams - + DESAT VCC1 DESAT VCC2 GND1 VCC2 RESET VC FAULT VOUT 5V VC FAULT VOUT VEE VLED1+ VEE VLED1- VEE VLED1- VEE Figure 31. IFAULTH test circuit. VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE 0.1 F 30 V 0.1 F 15 V PULSED + - + - 30 V IOUT VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 0.1 F 0.1 F RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE VE 0.1 F VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE + - VIN- 5V 30 V 0.1 F + - 30 V + - 14 V Figure 34. IOLF test circuit. 30 V 0.1 F 0.1 F + - IOUT 30 V + 15 V - PULSED Figure 33. IOL pulsed test circuit. IOUT 15 RESET IFAULT + - 5V + - VLED1+ VIN+ 0.1 F VLED2+ GND1 5V Figure 32. IOH pulsed test circuit. + - VIN- VCC1 VIN+ + - VE VLED2+ Figure 30. IFAULTL test circuit. 5V VIN+ VIN- IFAULT 0.1 F 0.1 F 10 mA + - 0.4 V + - 0.1 F + - 4.5 V VE 0.1 F + - 0.1 F VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE Figure 35. VOH pulsed test circuit. 0.1 F + - VIN+ 0.1 F 30 V 0.1 F + - VOUT 30 V 2A PULSED 0.1 F VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET 0.1 F VOUT VLED1+ VEE VLED1- VEE 5.5 V 30 V 30 V VOUT 0.1 F VE VIN- VLED2+ VCC1 DESAT 0.1 F 5V ICC1 VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE + - VIN+ VE VIN- VLED2+ VCC1 DESAT 0.1 F 30 V ICC2 GND1 VCC2 GND1 VCC2 RESET VC RESET VC FAULT VOUT FAULT VOUT VLED1+ VEE VLED1+ VEE VLED1- VEE VLED1- VEE Figure 38. ICC1L test circuit. VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 0.1 F 0.1 F 5V 30 V ICC2 RESET VC FAULT VOUT VLED1+ VLED1- 0.1 F + - VIN+ VE VIN- VLED2+ + - 0.1 F ICHG VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VEE VLED1+ VEE VEE VLED1- VEE Figure 40. ICC2L test circuit. 0.1 F 30 V Figure 39. ICC2H test circuit. + - VIN+ 16 VE VIN- + - 0.1 F 30 V Figure 41. ICHG pulsed test circuit. 0.1 F + - + - VIN+ Figure 37. ICC1H test circuit. VIN+ 5.5 V ICC1 + - Figure 36. VOL test circuit. 0.1 F + - 0.1 F 100 mA VC FAULT 0.1 F + - + - VIN+ + - 5V 0.1 F 30 V 0.1 F + - 0.1 F 30 V VE VLED2+ DESAT GND1 VCC2 RESET 0.1 F + - VCC2 SWEEP + - VC VEE VLED1- VEE VOUT 0.1 F Figure 43. UVLO threshold test circuit. VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT SWEEP 0.1 F 0.1 F 15 V + - VIN- VIN + - VE + - VIN+ 0.1 F 5V + - 15 V 3k VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1+ VEE VLED1- VEE VLED1- VEE VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE Figure 46. tDESAT(10%) test circuit. VIN 0.1 F 0.1 F + - VIN+ 0.1 F 30 V 0.1 F 0.1 F VOUT + - 30 V 10 10 nF Figure 45. tPLH, tPHL, tr, tf test circuit. Figure 44. DESAT threshold test circuit. 3k GND1 VEE 0.1 F 5V DESAT VLED1+ 30 V 0.1 F Figure 42. IDSCHG test circuit. + - VCC1 VEE VLED1- 0.1 F VLED2+ VOUT VLED1+ 0.1 F VIN- FAULT VOUT 10 mA VE RESET VC FAULT 17 + - 5V 30 V VIN+ + - 30 V VOUT 10 10 nF 0.1 F 5V 0.1 F + - 3k VFAULT 30 V VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE Figure 47. tDESAT(FAULT) test circuit. VIN 0.1 F + - VCC1 IDSCHG 0.1 F + - VIN- 0.1 F + - 7V + - VIN+ 30 V 0.1 F 0.1 F 10 10 nF + - 30 V + - 5V 3k VIN HIGH TO LOW VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 FAULT VOUT VLED1+ VEE VLED1- VEE 0.1 F 30 V + - 5V 0.1 F VC RESET VFAULT 0.1 STROBE F 8V + - 0.1 F 0.1 F + - 30 V 10 3k 10 nF Figure 48. tRESET(FAULT) test circuit. 0.1 F 1 VIN+ VE 16 2 VIN- VLED2+ 15 3 VCC1 DESAT 14 4 GND1 VCC2 13 5 RESET VC 12 0.1 F 25 V 0.1 F SCOPE 100 pF VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE 6 FAULT VOUT 11 7 VLED1+ VEE 10 8 VLED1 VEE 9 10 VIN+ VE 16 2 VIN- VLED2+ 15 3 VCC1 DESAT 14 4 GND1 VCC2 13 5 RESET VC 12 6 FAULT VOUT 11 7 VLED1+ VEE 10 8 VLED1 VEE 9 0.1 F 10 10 nF 9V Figure 51. CMR test circuit, LED2 on. VIN+ VE 16 2 VIN- VLED2+ 15 3 VCC1 DESAT 14 5V 25 V 0.1 F 0.1 F GND1 25 V VCm 1 4 10 nF 750 10 nF Figure 50. CMR test circuit, LED2 off. 0.1 F 10 1 VCm 5V RAMP 0.1 F VOUT + - 100 pF VIN- 3 k 3 k SCOPE VE Figure 49. UVLO delay test circuit. 5V 5V VIN+ VCC2 13 3 k 1 VIN+ VE 16 2 VIN- VLED2+ 15 3 VCC1 DESAT 14 4 GND1 VCC2 13 5 RESET VC 12 6 FAULT VOUT 11 7 VLED1+ VEE 10 8 VLED1 VEE 9 0.1 F 3 k 5 RESET VC 12 6 FAULT VOUT 11 7 VLED1+ VEE 10 8 VLED1 VEE 9 25 V SCOPE 100 pF VCm Figure 52. CMR test circuit, LED1 off. 18 10 10 nF 100 pF VCm Figure 53. CMR test circuit, LED1 on. SCOPE 10 10 nF VINVIN- 0V VIN+ 2.5 V 2.5 V VIN+ 2.5 V 5.0 V 2.5 V tr tf tr 90% 90% 50% 50% 10% VOUT tPLH tf 10% VOUT tPHL tPLH Figure 54. VOUT propagation delay waveforms, noninverting configuration. tPHL Figure 55. VOUT propagation delay waveforms, inverting configuration. tDESAT (FAULT) tDESAT (10%) tDESAT (LOW) 7V VDESAT 50% tDESAT (90%) VOUT 90% 10% FAULT 50% (2.5 V) tRESET (FAULT) RESET Figure 56. Desat, VOUT, fault, reset delay waveforms. 19 50% VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 0.1 F VC FAULT VOUT + - RESET 5V 0.1 F + - 30 V 650 A VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1+ VEE VLED1- VEE VLED1- VEE 0.1 F DESAT GND1 VCC2 VC 5V + - VLED2+ VCC1 + - 30 V 0.1 F IC + - 0.1 F VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT FAULT VOUT VLED1+ VEE VLED1+ VEE VLED1- VEE VLED1- VEE 0.1 F 30 V Figure 59. ICL test circuit. + - VIN+ VE VIN- VLED2+ VCC1 DESAT GND1 VCC2 RESET VC FAULT VOUT VLED1+ VEE VLED1- VEE Figure 61. IEL test circuit. 20 Figure 60. IEH test circuit. IE 0.1 F + - 5V 0.1 F 30 V 0.1 F IC + - 0.1 F 30 V Figure 58. ICH test circuit. VE RESET VIN+ 0.1 F IC Figure 57. ICH test circuit. VIN- 0.1 F 30 V 0.1 F VIN+ + - 30 V 0.1 F 0.1 F + - 30 V IE 0.1 F + - 0.1 F + - + - 5V 30 V 0.1 F 0.1 F + - 30 V Typical Application/Operation Introduction to Fault Detection and Protection The power stage of a typical three phase inverter is susceptible to several types of failures, most of which are potentially destructive to the power IGBTs. These failure modes can be grouped into four basic categories: phase and/or rail supply short circuits due to user misconnect or bad wiring, control signal failures due to noise or computational errors, overload conditions induced by the load, and component failures in the gate drive circuitry. Under any of these fault conditions, the current through the IGBTs can increase rapidly, causing excessive power dissipation and heating. The IGBTs become damaged when the current load approaches the saturation current of the device, and the collector to emitter voltage rises above the saturation voltage level. The drastically increased power dissipation very quickly overheats the power device and destroys it. To prevent damage to the drive, fault protection must be implemented to reduce or turn-off the overcurrents during a fault condition. A circuit providing fast local fault detection and shutdown is an ideal solution, but the number of required components, board space consumed, cost, and complexity have until now limited its use to high performance drives. The features which this circuit must have are high speed, low cost, low resolution, low power dissipation, and small size. 21 Applications InformationThe HCPL-316J satisfies these criteria by combining a high speed, high output current driver, high voltage optical isolation between the input and output, local IGBT desaturation detection and shut down, and an optically isolated fault status feedback signal into a single 16-pin surface mount package. The fault detection method, which is adopted in the HCPL-316J, is to monitor the saturation (collector) voltage of the IGBT and to trigger a local fault shutdown sequence if the collector voltage exceeds a predetermined threshold. A small gate discharge device slowly reduces the high short circuit IGBT current to prevent damaging voltage spikes. Before the dissipated energy can reach destructive levels, the IGBT is shut off. During the off state of the IGBT, the fault detect circuitry is simply disabled to prevent false `fault' signals. The alternative protection scheme of measuring IGBT current to prevent desaturation is effective if the short circuit capability of the power device is known, but this method will fail if the gate drive voltage decreases enough to only partially turn on the IGBT. By directly measuring the collector voltage, the HCPL-316J limits the power dissipation in the IGBT even with insufficient gate drive voltage. Another more subtle advantage of the desaturation detection method is that power dissipation in the IGBT is monitored, while the current sense method relies on a preset current threshold to predict the safe limit of operation. Therefore, an overlyconservative overcurrent threshold is not needed to protect the IGBT. Recommended Application Circuit The HCPL-316J has both inverting and non-inverting gate control inputs, an active low reset input, and an open collector fault output suitable for wired `OR' applications. The recommended application circuit shown in Figure 62 illustrates a typical gate drive implementation using the HCPL-316J. The four supply bypass capacitors (0.1 F) provide the large transient currents necessary during a switching transition. Because of the transient nature of the charging currents, a low current (5 mA) power supply suffices. The desat diode and 100 pF capacitor are the necessary external components for the fault detection circuitry. The gate resistor (10 ) serves to limit gate charge current and indirectly control the IGBT collector voltage rise and fall times. The open collector fault output has a passive 3.3 k pull-up resistor and a 330 pF filtering capacitor. A 47 k pulldown resistor on VOUT provides a more predictable high level output voltage (VOH). In this application, the IGBT gate driver will shut down when a fault is detected and will not resume switching until the microcontroller applies a reset signal. HCPL-316J 1 VIN+ VE 16 2 VIN- VLED2+ 15 3 VCC1 DESAT 14 0.1 F 0.1 F 100 pF DDESAT 100 C 5V + - 3.3 k 0.1 F + - VF 330 pF 4 GND1 5 6 VCC2 13 RESET VC 12 FAULT VOUT 11 7 VLED1+ VEE 10 8 VLED1- VEE 9 + - VCC2 = 18 V Q1 VCE Rg 47 k + - 0.1 F 3-PHASE OUTPUT + - Q2 VEE = -5 V + VCE - Figure 62. Recommended application circuit. Description of Operation/Timing Figure 63 below illustrates input and output waveforms under the conditions of normal operation, a desat fault condition, and normal reset behavior. Normal Operation During normal operation, VOUT of the HCPL-316J is controlled by either VIN+ or VIN-, with the IGBT collector-to-emitter voltage being monitored through DDESAT. The FAULT output is NORMAL OPERATION VINNON-INVERTING CONFIGURED INPUTS INVERTING CONFIGURED INPUTS high and the RESET input should be held high. See Figure 63. Fault Condition When the voltage on the DESAT pin exceeds 7 V while the IGBT is on, VOUT is slowly brought low in order to "softly" turn-off the IGBT and prevent large di/dt induced voltages. Also activated is an internal feedback channel which brings the FAULT output low for the purpose of notifying FAULT CONDITION 0V 5V VIN+ VIN- 5V VIN+ 5V 7V VDESAT VOUT FAULT RESET Figure 63. Timing diagram. 22 the micro-controller of the fault condition. See Figure 63. RESET Reset The FAULT output remains low until RESET is brought low. See Figure 63. While asserting the RESET pin (LOW), the input pins must be asserted for an output low state (VIN+ is LOW or VIN- is HIGH). This may be accomplished either by software control (i.e. of the microcontroller) or hardware control (see Figures 73 and 74). Slow IGBT Gate Discharge During Fault Condition When a desaturation fault is detected, a weak pull-down device in the HCPL-316J output drive stage will turn on to `softly' turn off the IGBT. This device slowly discharges the IGBT gate to prevent fast changes in drain current that could cause damaging voltage spikes due to lead and wire inductance. During the slow turn off, the large output pull-down device remains off until the output voltage falls below VEE + 2 Volts, at which time the large pull down device clamps the IGBT gate to VEE. DESAT Fault Detection Blanking Time The DESAT fault detection circuitry must remain disabled for a short time period following the turn-on of the IGBT to allow the collector voltage to fall below the DESAT theshold. This time period, called the DESAT blanking time, is controlled by the internal DESAT charge current, the DESAT voltage threshold, and the external DESAT capacitor. The nominal blanking time is calculated in terms of external capacitance (CBLANK), FAULT threshold 23 voltage (VDESAT), and DESAT charge current (ICHG) as tBLANK = CBLANK x VDESAT / ICHG. The nominal blanking time with the recommended 100 pF capacitor is 100 pF * 7 V / 250 A = 2.8 sec. The capacitance value can be scaled slightly to adjust the blanking time, though a value smaller than 100 pF is not recommended. This nominal blanking time also represents the longest time it will take for the HCPL-316J to respond to a DESAT fault condition. If the IGBT is turned on while the collector and emitter are shorted to the supply rails (switching into a short), the soft shut-down sequence will begin after approximately 3 sec. If the IGBT collector and emitter are shorted to the supply rails after the IGBT is already on, the response time will be much quicker due to the parasitic parallel capacitance of the DESAT diode. The recommended 100 pF capacitor should provide adequate blanking as well as fault response times for most applications. Under Voltage Lockout The HCPL-316J Under Voltage Lockout (UVLO) feature is designed to prevent the application of insufficient gate voltage to the IGBT by forcing the HCPL-316J output low during power-up. IGBTs typically require gate voltages of 15 V to achieve their rated VCE(ON) voltage. At gate voltages below 13 V typically, their onvoltage increases dramatically, especially at higher currents. At very low gate voltages (below 10 V), the IGBT may operate in the linear region and quickly overheat. The UVLO function causes the output to be clamped whenever insufficient operating supply (VCC2) is applied. Once VCC2 exceeds VUVLO+ (the positive-going UVLO threshold), the UVLO clamp is released to allow the device output to turn on in response to input signals. As VCC2 is increased from 0 V (at some level below VUVLO+), first the DESAT protection circuitry becomes active. As VCC2 is further increased (above VUVLO+), the UVLO clamp is released. Before the time the UVLO clamp is released, the DESAT protection is already active. Therefore, the UVLO and DESAT FAULT DETECTION features work together to provide seamless protection regardless of supply voltage (VCC2). Behavioral Circuit Schematic The functional behavior of the HCPL-316J is represented by the logic diagram in Figure 64 which fully describes the interaction and sequence of internal and external signals in the HCPL-316J. Input IC In the normal switching mode, no output fault has been detected, and the low state of the fault latch allows the input signals to control the signal LED. The fault output is in the open-collector state, and the state of the Reset pin does not affect the control of the IGBT gate. When a fault is detected, the FAULT output and signal never on at the same time. If an undervoltage condition is detected, the output will be actively pulled low by the 50x DMOS device, regardless of the LED state. If an IGBT desaturation fault is detected while the signal LED is on, the Fault signal will latch in the high state. The triple darlington AND the 50x DMOS device are disabled, and a smaller 1x DMOS pull-down device is activated to slowly discharge the IGBT gate. When the output drops below two volts, the 50x DMOS device again turns on, clamping the IGBT gate firmly to Vee. The Fault signal remains latched in the high state until the signal LED turns off. input are both latched. The fault output changes to an active low state, and the signal LED is forced off (output LOW). The latched condition will persist until the Reset pin is pulled low. Output IC Three internal signals control the state of the driver output: the state of the signal LED, as well as the UVLO and Fault signals. If no fault on the IGBT collector is detected, and the supply voltage is above the UVLO threshold, the LED signal will control the driver output state. The driver stage logic includes an interlock to ensure that the pull-up and pull-down devices in the output stage are 250 A DESAT (14) + VIN+ (1) VIN- (2) - LED VCC1 (3) GND (4) VE (16) UVLO DELAY 7V VCC2 (13) - + 12 V FAULT VC (12) FAULT (6) Q VOUT (11) R S RESET (5) 50 x FAULT VEE (9,10) 1x Figure 64. Behavioral circuit schematic. 24 HCPL-316J HCPL-316J 1 VIN+ 2 VIN- 3 VCC1 4 GND1 5 RESET 6 FAULT 7 VLED1+ 8 VLED1- HCPL-316J VE 16 VE 16 VLED2+ 15 VLED2+ 15 100 pF C DESAT 14 DESAT 14 VCC2 13 VCC2 13 VC 12 VC 12 VOUT 11 VOUT 11 Rg VEE 10 VEE 9 RPULL-DOWN 100 DDESAT Rg VEE 10 VEE 9 3.3 k 330 pF + - Figure 65. Output pull-down resistor. Figure 66. DESAT pin protection. Figure 67. FAULT pin CMR protection. Other Recommended Components The application circuit in Figure 62 includes an output pull-down resistor, a DESAT pin protection resistor, a FAULT pin capacitor (330 pF), and a FAULT pin pullup resistor. DESAT Pin Protection The freewheeling of flyback diodes connected across the IGBTs can have large instantaneous forward voltage transients which greatly exceed the nominal forward voltage of the diode. This may result in a large negative voltage spike on the DESAT pin which will draw substantial current out of the IC if protection is not used. To limit this current to levels that will not damage the IC, a 100 ohm resistor should be inserted in series with the DESAT diode. The added resistance will not alter the DESAT threshold or the DESAT blanking time. The added capacitance does not increase the fault output delay when a desaturation condition is detected. Output Pull-Down Resistor During the output high transition, the output voltage rapidly rises to within 3 diode drops of VCC2. If the output current then drops to zero due to a capacitive load, the output voltage will slowly rise from roughly VCC2-3(VBE) to VCC2 within a period of several microseconds. To limit the output voltage to VCC2-3(VBE), a pull-down resistor between the output and VEE is recommended to sink a static current of several 650 A while the output is high. Pull-down resistor values are dependent on the amount of positive supply and can be adjusted according to the formula, Rpull-down = [VCC2-3 * (VBE)] / 650 A. 25 Capacitor on FAULT Pin for High CMR Rapid common mode transients can affect the fault pin voltage while the fault output is in the high state. A 330 pF capacitor (Fig. 66) should be connected between the fault pin and ground to achieve adequate CMOS noise margins at the specified CMR value of 15 kV/s. Pull-up Resistor on FAULT Pin The FAULT pin is an opencollector output and therefore requires a pull-up resistor to provide a high-level signal. Driving with Standard CMOS/TTL for High CMR Capacitive coupling from the isolated high voltage circuitry to the input referred circuitry is the primary CMR limitation. This coupling must be accounted for to achieve high CMR performance. The input pins VIN+ and VIN- must have active drive signals to prevent unwanted switching of the output under extreme common mode transient conditions. Input drive circuits that use pull-up or pull-down resistors, such as open collector configurations, should be avoided. Standard CMOS or TTL drive circuits are recommended. User-Configuration of the HCPL-316J Input Side The VIN+, VIN-, FAULT and RESET input pins make a wide variety of gate control and fault configurations possible, depending on the motor drive requirements. The HCPL-316J has both inverting and noninverting gate control inputs, an open collector fault output suitable for wired `OR' applications and an active low reset input. Driving Input pf HCPL-316J in Non-Inverting/Inverting Mode The Gate Drive Voltage Output of the HCPL-316J can be configured as inverting or non-inverting using the VIN- and VIN+ inputs. As shown in Figure 68, when a non-inverting configuration is desired, VIN- is held low by connecting it to GND1 and VIN+ is toggled. As shown in Figure 69, when an inverting configuration is desired, VIN+ is held high by connecting it to VCC1 and VIN- is toggled. HCPL-316J C VIN+ 1 VIN+ 2 VIN- 2 VIN- 3 VCC1 3 VCC1 + - C + - 4 GND1 4 GND1 5 RESET 5 RESET 6 FAULT 6 FAULT 7 VLED1+ 7 VLED1+ 8 VLED1- 8 VLED1- Figure 68. Typical input configuration, noninverting. 26 HCPL-316J 1 Figure 69. Typical Input Configuration, Inverting. Local Shutdown, Local Reset As shown in Figure 70, the fault output of each HCPL-316J gate driver is polled separately, and the individual reset lines are asserted low independently to reset the motor controller after a fault condition. Global-Shutdown, Global Reset As shown in Figure 71, when configured for inverting operation, the HCPL-316J can be configured to shutdown automatically in the event of a fault condition by tying the FAULT output to VIN+. For high reliability drives, the open collector FAULT outputs of each HCPL-316J can be wire `OR'ed together on a common fault bus, forming a single fault bus for interfacing directly to the microcontroller. When any of the six gate drivers detects a fault, the fault output signal will disable all six HCPL-316J gate drivers simultaneously and thereby provide protection against further catastrophic failures. Auto-Reset As shown in Figure 72, when the inverting VIN- input is connected to ground (non-inverting configuration), the HCPL-316J can be configured to reset automatically by connecting RESET to VIN+. In this case, the gate control signal is applied to the non-inverting input as well as the reset input to reset the fault latch every switching cycle. During normal operation of the IGBT, asserting the reset input low has no effect. Following a fault condition, the gate driver remains in the latched fault state until the gate control signal changes to the `gate low' state and resets the fault latch. If the gate control signal is a HCPL-316J 1 VIN+ 2 VIN- 3 VCC1 4 GND1 5 RESET 6 FAULT 7 VLED1+ 8 VLED1- + - C Figure 70. Local shutdown, local reset configuration. HCPL-316J 1 VIN+ 2 VIN- 3 VCC1 4 GND1 5 RESET 6 FAULT 7 VLED1+ 8 VLED1- + - C CONNECT TO OTHER RESETS CONNECT TO OTHER FAULTS Figure 71. Global-shutdown, global reset configuration. HCPL-316J C 1 VIN+ 2 VIN- 3 VCC1 4 GND1 5 RESET 6 FAULT 7 VLED1+ 8 VLED1- + - Figure 72. Auto-reset configuration. 27 continuous PWM signal, the fault latch will always be reset by the next time the input signal goes high. This configuration protects the IGBT on a cycle-by-cycle basis and automatically resets before the next `on' cycle. The fault outputs can be wire `OR'ed together to alert the microcontroller, but this signal would not be used for control purposes in this (Auto-Reset) configuration. When the HCPL- 316J is configured for Auto-Reset, the guaranteed minimum FAULT signal pulse width is 3 s. Resetting Following a Fault Condition To resume normal switching operation following a fault condition (FAULT output low), the RESET pin must first be asserted low in order to release the internal fault latch and reset the FAULT output (high). Prior to asserting the RESET pin low, the input (VIN) switching signals must be configured for an output (VOL) low state. This can be handled directly by the microcontroller or by hardwiring to synchronize the RESET signal with the appropriate input signal. Figure 73a shows how to connect the RESET to the VIN+ signal for safe automatic reset in the noninverting input configuration. Figure 73b shows how to configure the VIN+/ RESET signals so that a RESET signal from the microcontroller causes the input to be in the "output-off" state. Similarly, Figures 73c and 73d show automatic RESET and microcontroller RESET safe configurations for the inverting input configuration. HCPL-316J 1 VIN+ 2 VIN- HCPL-316J VIN+ VCC 1 VIN+ 2 VIN- 3 VCC1 4 GND1 5 RESET 6 FAULT VCC 3 VCC1 C C VIN+/ RESET FAULT 4 GND1 5 RESET 6 FAULT 7 VLED1+ 7 VLED1+ 8 VLED1- 8 VLED1- RESET FAULT Figure 73a. Safe hardware reset for noninverting input configuration (automatically resets for every VIN+ input). Figure 73b. Safe hardware reset for noninverting input configuration. HCPL-316J VCC 1 VIN+ 2 VIN- HCPL-316J VCC VIN- VIN- VCC 1 VIN+ 2 VIN- 3 VCC1 4 GND1 5 RESET 6 FAULT VCC 3 VCC1 C C 4 GND1 RESET RESET FAULT 5 RESET 6 FAULT 7 VLED1+ 7 VLED1+ 8 VLED1- 8 VLED1- FAULT Figure 73c. Safe hardware reset for inverting input configuration. User-Configuration of the HCPL-316J Output Side RG and Optional Resistor RC: The value of the gate resistor RG (along with VCC2 and VEE) determines the maximum amount of gate-charging/ discharging current (ION,PEAK and IOFF,PEAK) and thus should be carefully chosen to match the size of the IGBT being driven. Often it is desirable to have the peak gate charge current be somewhat less than the peak 28 Figure 73d. Safe hardware reset for inverting input configuration (automatically resets for every VIN- input). discharge current (ION,PEAK < IOFF,PEAK). For this condition, an optional resistor (RC) can be used along with RG to independently determine ION,PEAK and IOFF,PEAK without using a steering diode. As an example, refer to Figure 74. Assuming that RG is already determined and that the design IOH,PEAK = 0.5 A, the value of RC can be estimated in the following way: RC + RG = [VCC2 - VOH - (VEE)] IOH,PEAK = [4 V - (-5 V)] 0.5 A = 18 ) RC = 8 See "Power and Layout Considerations" section for more information on calculating value of RG. Higher Output Current Using an External Current Buffer: To increase the IGBT gate drive current, a non-inverting current buffer (such as the npn/pnp buffer shown in Figure 75) may be used. Inverting types are not compatible with the desatura-tion fault protection circuitry and should be avoided. To preserve the slow IGBT turn-off feature during a fault condition, a 10 nF capacitor should be connected from the buffer input to VEE and a 10 W resistor inserted between the output and the common npn/ pnp base. The MJD44H11/ MJD45H11 pair is appropriate for currents up to 8A maximum. The D44VH10/ D45VH10 pair is appropriate for currents up to 15 A maximum. HCPL-316J VE 16 VLED2+ 15 DESAT 14 VCC2 13 VC 12 VOUT 11 VEE 10 VEE 9 100 pF RC 8 10 10 nF 15 V -5 V Figure 74. Use of RC to further limit ION,PEAK. DESAT Diode and DESAT Threshold The DESAT diode's function is to conduct forward current, allowing HCPL-316J VE 16 VLED2+ 15 DESAT 14 VCC2 13 VC 12 VOUT 11 VEE 10 VEE 9 100 pF MJD44H11 or D44VH10 4.5 10 2.5 10 nF MJD45H11 or D45VH10 15 V -5 V sensing of the IGBT's saturated collector-to-emitter voltage, VCESAT, (when the IGBT is "on") and to block high voltages (when the IGBT is "off"). During the short period of time when the IGBT is switching, there is commonly a very high dVCE/dt voltage ramp rate across the IGBT's collector-to-emitter. This results in ICHARGE (= CD-DESAT x dVCE/dt) charging current which will charge the blanking capacitor, CBLANK. In order to minimize this charging current and avoid false DESAT triggering, it is best to use fast response diodes. Listed in the below table are fast-recovery diodes that are suitable for use as a DESAT diode (DDESAT). In the recommended application circuit shown in Figure 62, the voltage on pin 14 (DESAT) is VDESAT = VF + VCE, (where VF is the forward ON voltage of DDESAT and VCE is the IGBT collector-to-emitter voltage). The value of VCE which triggers DESAT to signal a FAULT condition, is nominally 7V - VF. If desired, this DESAT threshold voltage can be decreased by using multiple DESAT diodes in series. If n is the number of DESAT diodes then the nominal threshold value becomes VCE,FAULT(TH) = 7 V - n x VF. In the case of using two diodes instead of one, diodes with half of the total required maximum reverse-voltage rating may be chosen. Figure 75. Current buffer for increased drive current. Part Number MUR1100E MURS160T3 UF4007 BYM26E BYV26E BYV99 Manufacturer Motorola Motorola General Semi. Philips Philips Philips Power/Layout Considerations Operating Within the Maximum Allowable Power Ratings (Adjusting Value of RG): When choosing the value of RG, it 29 trr (ns) 75 75 75 75 75 75 Max. Reverse Voltage Rating, VRRM (Volts) 1000 600 1000 1000 1000 600 is important to confirm that the power dissipation of the HCPL-316J is within the maximum allowable power rating. Package Type 59-04 (axial leaded) Case 403A (surface mount) DO-204AL (axial leaded) SOD64 (axial leaded) SOD57 (axial leaded) SOD87 (surface mount) The steps for doing this are: 1. Calculate the minimum desired RG; 2. Calculate total power dissipation in the part referring to Figure 77. (Average switching energy supplied to HCPL-316J per cycle vs. RG plot); 3. Compare the input and output power dissipation calculated in step #2 to the maximum recommended dissipation for the HCPL-316J. (If the maximum recommended level has been exceeded, it may be necessary to raise the value of RG to lower the switching power and repeat step #2.) and output-side power (PO): As an example, the total input and output power dissipation can be calculated given the following conditions: * ION, MAX ~ 2.0 A * VCC2 = 18 V * VEE = -5 V * fCARRIER = 15 kHz PO(SWITCH) = transient power dissipation in the HCPL-316J due to charging and discharging power device gate. [VOH@650 A - (VOL+VEE)] RG = -------------------------------------- IOL,PEAK [VCC2 - 1 - (VOL + VEE )] = ---------------------------------- IOL,PEAK 18 V - 1 V - (1.5 V + (-5 V)) = -------------------------------------- 2.0 A = 10.25 W 10.5 W (for a 1% resistor) (Note from Figure 76 that the real value of IOL may vary from the value calculated from the simple model shown.) Step 2: Calculate total power dissipation in the HCPL-316J: The HCPL-316J total power dissipation (PT) is equal to the sum of the input-side power (PI) 30 3 PI = ICC1 * VCC1 = ICC2 * (VCC2-VEE ) + ESWITCH * fSWITCH 2 ION, IOFF (A) PO = PO(BIAS) + PO,SWTICH 1 IOFF (MAX.) 0 ION (MAX.) -1 where, PO(BIAS) = steady-state power dissipation in the HCPL-316J due to biasing the device. -2 -3 Figure 76. Typical peak ION and IOFF currents vs. Rg (for HCPL-316J output driving an IGBT rated at 600 V/100 A. ESWITCH = Average Energy dissipated in HCPL-316J due to switching of the power device over one switching cycle (J/cycle). SWITCHING ENERGY vs. GATE RESISTANCE (VCC2 / VEE2 = 25 V / 5 V 9 8 fSWITCH = average carrier signal frequency. For RG = 10.5, the value read from Figure 77 is ESWITCH = 6.05 J. Assume a worst-case average ICC1 = 16.5 mA (which is given by the average of ICC1H and ICC1L ). Similarly the average ICC2 = 5.5 mA. PI = 16.5 mA * 5.5 V = 90.8 mW PO = PO(BIAS) + PO,SWITCH 0 20 40 60 80 100 120 140 160 180 200 Rg () 7 6 Ess (J) Step 1: Calculate RG minimum from IOL peak specification: To find the peak charging lOL assume that the gate is initially charged the steady-state value of VEE. Therefore apply the following relationship: 4 PT = PI + PO MAX. ION, IOFF vs. GATE RESISTANCE (VCC2 / VEE2 = 25 V / 5 V 5 Ess (Qg = 650 nC) 4 3 2 1 0 0 50 100 150 200 Rg () Figure 77. Switching energy plot for calculating average Pswitch (for HCPL-316J output driving an IGBT rated at 600 V/100 A). = 5.5 mA * (18 V - (-5 V)) + 6.051 J * 15 kHz = 126.5 mW + 90.8 mW = 217.3 mW Step 3: Compare the calculated power dissipation with the absolute maximum values for the HCPL-316J: For the example, PI = 90.8 mW < 150 mW (abs. max.) ) OK PO = 217.3 mW < 600 mW (abs. max.) ) OK Therefore, the power dissipation absolute maximum rating has not been exceeded for the example. Please refer to the following Thermal Model section for an explanation on how to calculate the maximum junction temperature of the HCPL-316J for a given PC board layout configuration. Thermal Model The HCPL-316J is designed to dissipate the majority of the heat through pins 4 for the input IC and pins 9 and 10 for the output IC. (There are two VEE pins on the output side, pins 9 and 10, for this purpose.) Heat flow through other pins or through the package directly into ambient are considered negligible and not modeled here. In order to achieve the power dissipation specified in the absolute maximum specification, it is imperative that pins 4, 9, and 10 have ground planes connected to them. As long as the maximum power specification is not exceeded, the only other limitation to the amount of power one can dissipate is the absolute maximum junction temperature specification of 125 C. The junction temperatures can be calculated with the following equations: Tji = Pi (qi4 + q4A) + TA Tjo = Po (qo9,10 + q9,10A) + TA where Pi = power into input IC and Po = power into output IC. Tji Tjo i4 = 60C/W O9,10 = 30C/W TP4 TP9,10 4A = 50C/W* Tji = Piqi4 + TP4 Tjo = Poqo9,10 + TP9,10 These equations, however, require that the pin 4 and pins 9, 10 temperatures be measured with a thermal couple on the pin at the HCPL-316J package edge. From the earlier power dissipation calculation example: Pi = 90.8 mW, Po = 314 mW, TA = 100 C, and assuming the thermal model shown in Figure 77 below. Tji = (90.8 mW)(60 C/W + 50 C/W) + 100 C = 110 C Tjo = (240 mW)(30 C/W + 50 C/W) + 100 C = 119 C both of which are within the absolute maximum specification of 125 C. If we, however, assume a worst case PCB layout and no air flow where the estimated q4A and q9,10A are 100 C/W. Then the junction temperatures become Tji = (90.8 mW)(60 C/W + 100 C/W) + 100 C = 115 C Tjo = (240 mW)(30 C/W + 100 C/W) + 100 C = 131 C The output IC junction temperature exceeds the absolute maximum specification of 125 C. In this case, PCB layout and airflow will need to be designed so that the junction temperature of the output IC does not exceed 125 C. If the calculated junction temperatures for the thermal model in Figure 78 is higher than 125 C, the pin temperature for pins 9 and 10 should be measured (at the package edge) under worst case operating environment for a more accurate estimate of the junction temperatures. Tji = junction temperature of input side IC Tjo = junction temperature of output side IC TP4 = pin 4 temperature at package edge TP9,10 = pin 9 and 10 temperature at package edge qI4 = input side IC to pin 4 thermal resistance qI9,10 = output side IC to pin 9 and 10 thermal resistance q4A = pin 4 to ambient thermal resistance q9,10A = pin 9 and 10 to ambient thermal resistance 9,10A = 50C/W* TA Figure 78. HCPL-316J thermal model. 31 Since q4A and q9,10A are dependent on PCB layout and airflow, their exact number may not be available. Therefore, a more accurate method of calculating the junction temperature is with the following equations: *The q4A and q9,10A values shown here are for PCB layouts shown in Figure 78 with reasonable air flow. This value may increase or decrease by a factor of 2 depending on PCB layout and/or airflow. Printed Circuit Board Layout Considerations Adequate spacing should always be maintained between the high voltage isolated circuitry and any input referenced circuitry. Care must be taken to provide the same minimum spacing between two adjacent high-side isolated regions of the printed circuit board. Insufficient spacing will reduce the effective isolation and increase parasitic coupling that will degrade CMR performance. The placement and routing of supply bypass capacitors Figure 79. Recommended layout(s). 32 requires special attention. During switching transients, the majority of the gate charge is supplied by the bypass capacitors. Maintaining short bypass capacitor trace lengths will ensure low supply ripple and clean switching waveforms. Ground Plane connections are necessary for pin 4 (GND1) and pins 9 and 10 (VEE) in order to achieve maximum power dissipation as the HCPL-316J is designed to dissipate the majority of heat generated through these pins. Actual power dissipation will depend on the application environment (PCB layout, air flow, part placement, etc.) See the Thermal Model section for details on how to estimate junction temperature. The layout examples below have good supply bypassing and thermal properties, exhibit small PCB footprints, and have easily connected signal and supply lines. The four examples cover single sided and double sided component placement, as well as minimal and improved performance circuits. System Considerations Propagation Delay Difference (PDD) The HCPL-316J includes a Propagation Delay Difference (PDD) specification intended to help designers minimize "dead time" in their power inverter designs. Dead time is the time period during which both the high and low side power transistors (Q1 and Q2 in Figure 62) are off. Any overlap in Q1 and Q2 conduction will result in large currents flowing through the power devices between the high and low voltage motor rails, a potentially catastrophic condition that must be prevented. conditions, transistor Q1 has just turned off when transistor Q2 turns on, as shown in Figure 80. The amount of delay necessary to achieve this condition is equal to the maximum value of the propagation delay difference specification, PDDMAX, which is specified to be 400 ns over the operating temperature range of -40 C to 100 C. Delaying the HCPL-316J turn-on signals by the maximum propagation delay difference ensures that the minimum dead time is zero, but it does not tell a designer what the maximum dead time will be. The maximum To minimize dead time in a given design, the turn-on of the HCPL-316J driving Q2 should be delayed (relative to the turn-off of the HCPL-316J driving Q1) so that under worst-case dead time is equivalent to the difference between the maximum and minimum propagation delay difference specifications as shown in Figure 81. The maximum dead time for the HCPL-316J is 800 ns (= 400 ns - (-400 ns)) over an operating temperature range of -40 C to 100 C. Note that the propagation delays used to calculate PDD and dead time are taken at equal temperatures and test conditions since the optocouplers under consideration are typically mounted in close proximity to each other and are switching identical IGBTs. VIN+1 VOUT1 Q1 ON Q1 OFF Q2 ON VOUT2 Q2 OFF VIN+1 VIN+2 VOUT1 tPHLMIN Q1 ON Q1 OFF tPHLMAX tPLHMIN tPLHMAX Q2 ON VOUT2 VIN+2 (tPHL-tPLH) Q2 OFF tPHLMAX tPLHMIN PDD* MAX = (tPHL- tPLH)MAX = tPHLMAX - tPLHMIN = PDD*MAX MAX MAXIMUM DEAD TIME (DUE TO OPTOCOUPLER) = (tPHLMAX - tPHLMIN) + (tPLHMAX - tPLHMIN) = (tPHLMAX - tPLHMIN) - (tPHLMIN - tPLHMAX) = PDD*MAX - PDD*MIN *PDD = PROPAGATION DELAY NOTE: FOR PDD CALCULATIONS THE PROPAGATION DELAYS ARE TAKEN AT THE SAME TEMPERATURE AND TEST CONDITIONS. *PDD = PROPAGATION DELAY DIFFERENCE NOTE: FOR DEAD TIME AND PDD CALCULATIONS ALL PROPAGATION DELAYS ARE TAKEN AT THE SAME TEMPERATURE AND TEST CONDITIONS. Figure 80. Minimum LED Skew for Zero Dead Time. Figure 81. Waveforms for Dead Time Calculation. 33 www.agilent.com/semiconductors For product information and a complete list of distributors, please go to our web site. For technical assistance call: Americas/Canada: +1 (800) 235-0312 or (916) 788-6763 Europe: +49 (0) 6441 92460 China: 10800 650 0017 Hong Kong: (+65) 6756 2394 India, Australia, New Zealand: (+65) 6755 1939 Japan: (+81 3) 3335-8152(Domestic/International), or 0120-61-1280(Domestic Only) Korea: (+65) 6755 1989 Singapore, Malaysia, Vietnam, Thailand, Philippines, Indonesia: (+65) 6755 2044 Taiwan: (+65) 6755 1843 Data subject to change. Copyright (c) 2005 Agilent Technologies, Inc. Obsoletes 5989-2143EN October 3, 2005 5989-2945EN