GP1U58X Series
GP1U58X Series
Outline Dimensions (Unit : mm )
Features
Applications
1. Less sensitive to fluorescent lamp driven
by inverter
1. TVs
2. VCRs
3. Audio equipment
4. Air conditioners
Absolute Maximum Ratings
(Ta= 25˚C)
Recommended Operating Conditions
*1 No dew formation
*2 For 5 seconds
Parameter Symbol Rating Unit
Operating supply voltage
VCC 0 to 6.3 V
*1 Operating temperature T opr
- 10 to +70
˚C
Storage temperature T stg
- 20 to +70
˚C
*2 Soldering temperature T sol 260 ˚C
22
1.6
3.6
1.7
2.54 2.54
3.3
14.21.4
3.9 2.4
Rib
Recommended drilling as viewed
from the soldering face
Rib
123
123
2 Vcc
3 GND
1
1
1 Detector center
1 Vout
2. Various B.P.F. (Band Pass Filter ) frequency
(Including protrusion of detector )
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
Remote Control
Parameter Symbol Value Unit
Operating supply voltage VCC 4.7 to 5.3 V
IR Detecting Unit For
* Tolerance 0.3mm
3-φ0.8
7.5±0.5
15+0.5
-0.3
3.65±0.5
12.6+0.5
-0.3
16.0
GP1U58X Series
Electrical Characteristics
Model Line-up
(Ta =25˚C, V CC =+ 5V)
Internal Block Diagram
The value of fO is shown in a separate table.
Duty 50%
Model No. B.P.F. frequency Unit
40
kHz
36
38
36.7
32.75
56.8
GP1U58X
GP1U580X
GP1U581X
GP1U582X
GP1U583X
GP1U587X
*3 The burst wave as shown in the following figure shall be transmitted by the transmitter shown in Fig. 1.
600µs600µs
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Dissipation current ICC No input light - - 5.0 mA
High level output voltage VOH
*3
V
CC
- 0.5
--V
Low level output voltage VOL - - 0.45 V
High level pulse width T 1400 - 800 µs
Low level pulse width T 2400 - 800
B.P.F. center frequency fO- - - kHz
*4 Diversified models with a different B.P.F frequency, as shown in a separate table, are also available.
*440
Vout
Vcc
GND
B.P.F.Limiter
Amp
ComparatorIntegratorDemodulator
GP1U58X Series
Performance
(2) Sensitivity angle reception distance characteristics
(3) Anti outer peripheral light reception distance characteristics
In the above figure, the transmitter should be set so that the output Vout can be 40mVPP .
However, the PD49PI to be used here should be of the short-circuit current ISC=2.6 µA at EV=
100 lx.
(EV is an illuminance by CIE standard light source A
(tungsten lamp ).)
20cm 10k+5V
10µF
PD49PI
10k
Oscilloscope
Vout
Transmitter
Vout
Transmitter (GL521 used)
Duty 50 %
Center frequency (fo)
depends on the attached
model list.
Fig. 1. Transmitter
Fig. 2. Standard optical system
Reception distance :L
Light detector face
illuminance:Ee
vertical directions. )
Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough
to meet the following items in the standard optical system in Fig. 2.
φ
φ
(φ indicates horizontal and
characteristcs in the attached list.
characteristics in the attached list.
characteristics in the attached list.
When L= 0.2 to 8m, Ee<10 lx and φ= in Fig. 2, the output signal shall meet the electrical
When L= 0.2 to 6m, Ee<10 lx and φ<= 30˚ in Fig. 2, the output signal shall meet the electrical
When L= 0.2 to 4m, Ee<= 300 lx and φ= in Fig. 2, the output signal shall meet the electrical
(1) Linear reception distance characteristics
Precautions for Use
(2) Pay attention to a malfunction of the light detecting unit when the surface is stained with
(3) The shield case chall be grounded on PWB pattern.
(4) Do not apply unnecessary force to the terminals and case form outside.
(5) Do not push the light detector surface (photodiode) from outside.
(6) To avoid the electorstatic breakdown of IC, handle the unit under the condition of ground-
(7) In case of adopting the infrared light detecting unit for the wireless remote control, use it
GP1U58X Series
(8) As for other general cautions, refer to the chapter“Precautions for Use”
characteristics and operating condition of light emitting device and the characteristics of
the light detecting unit.
dust and refuse. Care must be taken not to touch the light detector surface. If it should be
dirty, wipe off with soft cloth so as to prevent scratch. In case some solvents are required,
use metyl alcohol, ethyl alcohol or isoprophyl alcohol. Also, protect the light detecting unit
against flux and others.
ing with human body, soldering iron, etc.
in accordance with the transmission scheme and the signal format recommended inCoun-
termeasures for malfunction prevention of home appliances with infrared remote control”
issued form Japan Association of Electrical Home Appliances (AEHA ) in July 1987.
(1) Use the light emitting unit (remote control transmitter), in consideration of performance,