CIRCUIT BREAKERS
24 LABINAL POWER SYSTEMS TF300-1E
SERIES 4310 AMBIENT TEMPERATURE-COMPENSATED SUB-MINIATURE CIRCUIT BREAKER
Sub-Miniature Size —
High Performance
Qualified
To MS3320 of Mil-C-5809.
Meets performance specifica-
tion of MS14105 of MIL-C-5809
High Interrupting Capacity
Interrupts 6,000A fault at 28V,
DC; up to 3,500A fault at 120V,
400 Hz., AC (ampere rating
dependent).
Vibration Resistance
Vibration resistance and
mechanical life exceed MIL
Specs — including random vibra-
tion.
Temperature-Compensated
Ambient-temperature-
compensated from -55°C to
+121°C.
Performance Rated Circuit
Breaker
The lightweight, single-phase
circuit breaker, Series 4310,
allows high density packaging
for all aircraft and aerospace
needs.
The 4310 series reflects the lat-
est advancements in circuit
breaker design — plus other
proven features (e.g., self-wiping
contacts).
Tight tolerances in design and
stringent manufacturing stan-
dards are key factors in the reli-
able operation of the 4310 under
severe environmental conditions
of high temperature, high
humidity, extreme vibration, and
shock. It is also fungus- and cor-
rosion-proof.
Calibration integrity is main-
tained through wide variations in
ambient temperature and alti-
tude, making this circuit breaker
ideal for applications where tem-
perature is not controlled.
Multiple Options
This series is available in many
optional configurations.
It is presently being manufactured with 7/16,
15/32 and metric mounting sleeves. Many ver-
sions of different terminals, barriers, and hard-
ware are current production items. Several dif-
ferent actuator options provide our customers
with additional flexibility.
OVERLOAD CALIBRATION DATA
Specification
Table
@ 25°C @ +121°C @ -55°C Test Time
ParametersMIN MAX MIN MAX MIN MAX
Must Hold 115 100 115 % For 1 Hour
Must Trip 138 138 160 % Within 1 Hour
200% Overload 5.00 20.00 1.500 13.00 7. 0 0 40.00 Seconds
500% Overload 0.50 2.00 0.150 1. 10 0.50 3.00 Seconds
1000% Overload 0.12 0.53 0.035 0.30 0.16 0.80 Seconds
Trip curves available.
PERFORMANCE DATA
Interrupting Capacity* 1 to 25A: 6,000A at 28V, DC. 1A: 3,500A at 120V, 400 Hz., AC
1 1/2 to 2 1/2A: 2,800A at 120V, 400 Hz., AC; 3 TO 15: 2,500A AT 120V, 400 Hz., AC;
20 to 25A: 2,000A at 120V, 400 Hz., AC
Endurance* At 120V, 400 Hz., AC or at 28V, DC: inductive load — 2,500 cycles; resistive load — 5,000 cycles;
mechanical cycling, no load — 10,000 cycles
Overload Cycling Minimum of 100 cycles at 200% rated current
Dielectric Strength At sea level, 25°C 1,500V, AC. At 70,000 ft. 121°C 500V, AC
Insulation Resistance Not less than 100 megohms at 500V, DC
Voltage Drop Varies with rating (see Ordering Information”)
Vibration* Meets specification MIL-STD-202, Method 204, Condition A-10G, 10-500 Hz.
MS “V” type,(4310-019) meets Condition B, 15G, 10-2,000 Hz. and Condition C 10G, 10-2,000 Hz.
Shock* Exceeds 50G’s, 11 Milli-sec (half-sine pulse) MIL-STD-202, Method 213 Test A
Acceleration Exceeds 10G’s
Weight 25 grams (.055 lbs.)
* Variations of these circuit breakers are capable of exceeding the standard Mil specification for endurance vibration, shock, and
Interrupting capacity. Consult the Business Unit for more information.
ORDERING INFORMATION
Standard
STANDARD
LONG
BUTTON
HIGH
VIBRATION
LONG BUTTON
VIBRATION
MS Approval
Status
AMPERE
RATING
VO LTAGE
DROP MAX. * MS P/N
LABINAL
MP P/N MS P/N
LABINAL
MP P/N MS P/N
LABINAL
MP P/N MS P/N
LABINAL
MP P/N
MS Approved 11. 10 MS3320-1 4310-001-1 MS3320-1L 4310-005-1 MS3320-1V 4310-019-1 MS3320-1VL 4310-024-1
Non MS
Approved 1 1/2 0.80 4310-001-105 4310-005-105 4310-019-105 4310-024-105
MS Approved 2 0.75 MS3320-2 4310-001-2 MS3320-2L 4310-005-2 MS3320-2V 4310-019-2 MS3320-2VL 4310-024-2
MS Approved 2 1/2 0.70 MS3320-2-1/2 4310-001-205 MS3320-2 1/2L 4310--005-205 MS3320-2 1/2V 4310-019-205 MS3320-2 1/2VL 4310-024-205
MS Approved 3 0.55 MS3320-3 4310-001-3 MS3320-3L 4310-005-3 MS3320-3V 4310-019-3 MS3320-3VL 4310-024-3
MS Approved 4 0.45 MS3320-4 4310-001-4 MS3320-4L 4310-005-4 MS3320-4V 4310-019-4 MS3320-4VL 4310-024-4
MS Approved 5 0.35 MS3320-5 4310-001-5 MS3320-5L 4310-005-5 MS3320-5V 4310-019-5 MS3320-5VL 4310-024-5
MS Approved 7 1/2 0.30 MS3320-7-1/2 4310-001-705 MS3320-7 1/2L 4310-005-705 MS3320-7 1/2V 4310-019-705 MS3320-7 1/2VL 4310-024-705
MS Approved 10 0.28 MS3320-10 4310-001-10 MS3320-10L 4310-005-10 MS3320-10V 4310-019-10 MS3320-10VL 4310-024-10
MS Approved 15 0.25 MS3320-15 4310-001-15 MS3320-15L 4310-005-15 MS3320-15V 4310-019-15 MS3320-15VL 4310-024-15
MS Approved 20 0.25 MS3320-20 4310-001-20 MS3320-20L 4310-005-20 MS3320-20V 4310-019-20 MS3320-20VL 4310-024-20
Non MS
Approved 25 0.20 4310-001-25 4310-005-25 4310-019-25 4310-024-25
LABINAL POWER SYSTEMS TF300-1E 25
SERIES 4310
DIMENSIONS
TRIP CURVE
.375 ± .005
.125 ± .005 DIA.
.453 ± .005 DIA.
RECOMMENDED MOUNTING
.781 MAX.
.375 ± .010
5
1.030
MAX.
1.343
MAX.
1.218
B*
.500
SCREW
MS51957-41
LOCKWASHER
MS35338-137
.045 ± .010
.005
.395 ± .005 DIA.
.593
BLACK BUTTON
WHITE TRIP
INDICATOR
A* MOUNTING NUT
MS25082-C18
MOUNTING
LOCKWASHER
MS35333-141
.4375-32UN-ZA
THREAD
Percentage Of Circuit Breakers Rated Current
Time To Open (Trip) In Seconds
MIL Spec Part No. A*Max. B*Min.
MS3320 4310-001 0.750 0.470
MS3320L 4310-005 1.125 0.845
MS3320V 4310-019 0.750 0.470
MS3320VL 4310-024 1.125 0.845
Min. Panel Thickness .025
Max. Panel Thickness .100
10000
1000
100
0
0.01 0.1 1.0 10 100 1000
TYPICAL
TRIP
CURVE
AT 25°C
160%
138%
UPPER LIMIT AT -55°C.
REFERENCE ONLY
10000
LOWER LIMIT AT +121°C.
REFERENCE ONLY
RANGE AT 25°C
115%
100%