Number: DB-212
January 2010/ F
Page 2
S E M IC O N D U C TO R
Electrical Characteristics TA = 25°C unless otherwise noted
Device Type
VZ @ IZT
(Volts)
Nominal
IZT
(mA)
ZZT @ IZT
()
Max
ZZK @ IZK = 0.25mA
()
Max
IR @ VR
(A)
Max
VR
(Volts)
TC1N5241B 11 20 22 600 2 8.4
TC1N5242B 12 20 30 600 1 9.1
TC1N5243B 13 9.5 13 600 0.5 9.9
TC1N5244B 14 9 15 600 0.1 10
TC1N5245B 15 8.5 16 600 0.1 11
TC1N5246B 16 7.8 17 600 0.1 12
TC1N5247B 17 7.4 19 600 0.1 13
TC1N5248B 18 7 21 600 0.1 14
TC1N5249B 19 6.6 23 600 0.1 14
TC1N5250B 20 6.2 25 600 0.1 15
TC1N5251B 22 5.6 29 600 0.1 17
TC1N5252B 24 5.2 33 600 0.1 18
TC1N5253B 25 5 35 600 0.1 19
TC1N5254B 27 4.6 41 600 0.1 21
TC1N5255B 28 4.5 44 600 0.1 21
TC1N5256B 30 4.2 49 600 0.1 23
TC1N5257B 33 3.8 58 700 0.1 25
TC1N5258B 36 3.4 70 700 0.1 27
TC1N5259B 39 3.2 80 800 0.1 30
TC1N5258B 36 3.4 70 700 0.1 27
TC1N5259B 39 3.2 80 800 0.1 30
TC1N5260B 43 3 93 900 0.1 33
TC1N5261B 47 2.7 105 1000 0.1 36
TC1N5262B 51 2.5 125 1100 0.1 39
TC1N5263B 56 2.2 150 1300 0.1 43
VF Forward Voltage = 1.1 V Maximum @ IF = 200 mA for all types
Notes:
1. TOLERANCE AND VOLTAGE DESIGNATION
The type numbers listed have zener voltage as shown and have a standard tolerance on the nominal zener voltage of ±5%. Device of
2% is indicated by a “C” instead of a “B”
2. SPECIALS AVAILABLE INCLUDE
Nominal zener voltages between the voltages shown and tighter voltage, for detailed information on price, availability and delivery,
contact you nearest Tak Cheong representative.
3. ZENER VOLTAGE (VZ) MEASUREMENT
The zener voltage (VZ) is tested under pulse condition.
4. ZENER IMPEDANCE (ZZ) DERIVATION
Zener impedance is derived from the 60-cycle ac voltage, which results when an ac current having an RMS value equal to 10% of the
dc zener current (IZT) is superimposed to IZT .