GaAs Broadband High Power SP3T Switch
DC - 4.0 GHz
Rev. V1
MASW-009482
2 • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.43537383 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and prod uct information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
Electrical Specifications: TA = 25°C, Z0 = 50 , VC = 0 V / 2.7 V, 1000 pF Capacitors 4
4. External DC blocking capacitors are required on all RF ports. Typical performance specifications are with 1000 pF blocking and decoupling
capacitors / as shown on the application schematic .
5. RX Interferer power set to –10 dBm during test to improve dynamic range of measurement system. Typical performance with –23 dBm
interferer is determined by using a linear relationship between interferer power level and cross modulation products.
Parameter Test Conditions Units Min. Typ. Max.
Insertion Loss
(All Paths)
1.0 GHz
2.0 GHz
2.5 GHz
dB
dB
dB
—
—
—
0.55
0.75
0.75
0.7
0.9
0.9
Isolation 1.0 GHz
2.0 GHz
2.5 GHz
dB
dB
dB
23
17
16
27
21
20
—
—
—
Return Loss
(All RF ports) DC - 2.5 GHz dB — 20 —
Input IP3 Two Tone, +23 dBm/tone, 5 MHz Spacing, 1 GHz
Two Tone, +23 dBm/tone, 5 MHz Spacing, 2 GHz dBm
dBm —
— 65
64 —
—
Cross Modulation
For Cell Band: Two-tone signal input:
TX1 = +22 dBm @ 820 MHz, TX2 = +22 dBm @ 821 MHz,
RX interferer = -23 dBm @ 865 MHz5
dBm
— -108 —
For PCS Band: Two-tone signal input:
TX1 = +18 dBm @ 1880 MHz, TX2 = +18 dBm @ 1881 MHz,
RX interferer = -23 dBm @ 1960 MHz5 dBm — -109 —
Input P0.1dB VC = 0 V/2.7 V, 1 GHz dBm — 36 —
Trise, Tfall 10% to 90% RF, 90% to 10% RF, 900 MHz ns — 45 —
Ton, Toff 50% control to 90% RF, and 50% control to 10% RF,
900 MHz ns — 70 —
Transients In Band mV — 40 —
Control Current VC = 0 V/2.7 V µA — 6 25
3rd Harmonic Fin = 1 GHz, Pin = +26 dBm
Fin = 2 GHz, Pin = +26 dBm dBc —
— 84
74 —
—
2nd Harmonic Fin = 1 GHz, Pin = +26 dBm
Fin = 2 GHz, Pin = +26 dBm dBc —
— 82
83 —
—
Truth Table 8,9
V1 V2 V3 ANT-RF1 ANT-RF2 ANT-RF3
1 0 0 On Off Off
0 1 0 Off On Off
0 0 1 Off Off On
8. Differential voltage, V (state 1) -V (state 0) must be 2.6 V
minimum and must not exceed 8.5 V.
9. Positive Control: 1 = +2.6 V to +8.0 V, 0 = 0 V +/- 0.2V
Negative Control: 1 = 0 V +/- 0.2V, 0 = -2.6 V to -8.0 V
Parameter Absolute Maximum
Input Power
(0.5 - 4.0 GHz, 2.6 V Control) +36 dBm
Control Voltage ±8.5 volts
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
Absolute Maximum Ratings 6,7
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
7. M/A-COM Technology does not recommend sustained
operation near these survivability limits.