100507/11 www.lem.com
Page 1/3
Current Transducer HAIS 50..400-P
and HAIS 50..100-TP
For the electronic measurement of currents: DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Primary nominal Primary current Type RoHS since
current rms measuring range date code
IPN (A) IPM (A)
50 ± 150 HAIS 50-P, HAIS 50-TP 1) 45231, 46272
100 ± 300 HAIS 100-P, HAIS 100-TP 1) 45231, 46012
150 ± 450 HAIS 150-P 46172
200 ± 600 HAIS 200-P 45231
400 ± 600 HAIS 400-P 47096
VOUT Output voltage (Analog) @ IP VOE ± (0.625· IP/IPN) V
GTH Theoretical sensitivity 0.625 V/IPN
VREF Reference voltage 2) - Output voltage 2.5 ± 0.025 V
VREF Output impedance typ. 200 W
VREF Load impedance ≥ 200 kW
RL Load resistance ≥ 2 kW
ROUT Output internal resistance < 5 W
CL Capacitive loading (± 20 %) =4.7 nF
VC Supply voltage (± 5 %)3) 5 V
IC Current consumption @ VC = 5 V 19 mA
X Accuracy 4) @ IPN , TA = 25°C ± 1 % of IPN
εL Linearity error 0 .. IPM ≤ ± 0.5 % of IPN
TCVOE Temperature coefcient of VOE ≤ ± 0.3 mV/K
TCVREF Temperature coefcient of VREF, +25°C...+85°C ± 0.01 %/K
-40°C...+25°C ± 0.015 %/K
TCVOE/VREF
Temperature coefcient of VOE / VREF ≤ ± 0.2 mV/K
TCG Temperature coefcient of G
≤ ± 0.05 % of reading/K
VOE Electrical offset voltage @ IP = 0, TA = 25°C VREF ± 0.025 V
VOM Magnetic offset voltage @ IP = 0,
after an overload of IPM HAIS 50-(T)P < ± 0.5 % of IPN
HAIS 100-(T)P..400-P < ± 0.4 % of IPN
tra Reaction time @ 10 % of IPN < 3 µs
tr Response time to 90 % of IPN step < 5 µs
di/dt di/dt accurately followed > 100 A/µs
Vno Output voltage noise (DC ..10 kHz) < 15 mVpp
(DC .. 1 MHz) < 40 mVpp
BW Frequency bandwidth (- 3 dB) 5) DC .. 50 kHz
Notes:
1)
-TP version is equipped with a primary bus bar.
2)
It is possible to overdrive V
REF
with an external reference voltage
between 1.5 - 2.8 V providing its ability to sink or source approximately 5 mA.
3)
Maximum supply voltage (not operating) < 6.5 V
4)
Excluding Offset and Magnetic offset voltage.
5) Small signal only to avoid excessive heatings of the magnetic core.
LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
IPN = 50 .. 400 A
Features
Hall effect measuring principle
Galvanic isolation between
primary and secondary circuit
Isolation test voltage 2500V
Low power consumption
Single power supply +5V
Fixed offset & gain
Bus bar version available for 50A
and 100A ratings.
Isolated plastic case recognized
according to UL94-V0.
Advantages
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
VREF. IN/OUT
Applications
AC variable speed drives
Static converters for DC motor
drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application domain
Industrial
All data are given with a RL = 10 kW
Accuracy - Dynamic performance data
Electrical data
100507/11 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice. www.lem.com
Page 2/3
Current Transducer HAIS 50..400-P and HAIS 50..100-TP
TA Ambient operating temperature - 40 .. + 85 °C
General data
TS Ambient storage temperature - 40 .. + 85 °C
m Mass (in brackets : TP version) 20 (30) g
Standards EN 50178: 1997
Isolation characteristics
Vb Rated isolation voltage rms with EN50178, IEC61010-1 standards
at following conditions
- Over voltage category III
- Pollution degree 2
- Heterogeneous eld
Vd Rms voltage for AC isolation test, 50 Hz, 1 min 2.5 kV
Ve Partial discharge extinction voltage rms @ 10pC
HAIS 50..400-P > 1 kV
HAIS 50..100-TP > 1.4 kV
Vw Impulse withstand voltage 1.2/50 µs 8 kV
dCp Creepage distance > 8 mm
dCl Clearance distance > 8 mm
CTI Comparative tracking index (Group I) > 600
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
Cable insulation (primary) Category
HAR 03 450V CAT III
HAR 05 550V CAT III
HAR 07 650V CAT III
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
100507/11 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice. www.lem.com
Page 3/3
Dimensions HAIS 50..400-P and HAIS 50..100-TP (in mm)
8
0.5
16
15
33
29
3
3.5
2-D1.0
6.5
1.5
11
6
14.5 11
33
29
0.5
2-D1.0
10
14.5 11
6.5
1.5
11
14
1.5
1.5
3
3.5
6
25.9
19.9
41
4 1
5
5
6
6
Terminal Pin Identification Recommended connection circuit
1...+5V
HAIS 50..400-P HAIS 50..100-TP
2...0V
3...OUTPUT
4...Vref. (IN/OUT)
5...Core Earth
6...NC.
1
2
3
4
5
+5V
0V
OUTPUT
Vref. (IN/OUT)
47nF
47nF
4.3
3-P1.8
4.3
3-P1.8
4-0.25x0.45
(*)
4.7nF
Front view Front view Right view
Bottom view Bottom view
(*) should be connected to 0V of Power Supply for better dv/dt immunity.
Arrow indicates positive current direction.
General tolerance : ±0.2mm
Unit : mm
Recommended PCB hole
Pin 1-4 : 0.7 ±0.1mm
Pin 5-6 : 1.5 ±0.1mm
Primary bus bar : 2.3 ±0.1mm
Ip 0V
Vref.(IN/OUT)
Vout
+Vc
Operation Principle
Required Connection Circuit
Dimensions HAIS 50..400-P and HAIS 50..100-TP (in mm. 1 mm = 0.0394 inch)
080821/8 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 3/3