http://www.tracopower.com Page 2 of 3
Industrial Power Supplies
TBL Series 15 to 150 Watt
Input Specifications
Input voltage – AC nominal rated 100 – 240 VAC; 50/60 Hz
TBL 150 models: 100 – 120 / 220 – 240 VAC; 50/60 Hz
– AC range (designed for) 85 – 264 VAC; 47 – 63 Hz
TBL 150 models: 85 – 132 / 187 – 264 VAC; 47 – 63 Hz
– Power derating at low input voltage 5% below 90 VAC or 127 VDC
Harmonic limits EN 61000-3-2, Class A
Recommended circuit breaker (characteristic C or slow blow fuse) 6.0 A
Output Specifications
Output voltage adjustable range 5 VDC model: 5.0 – 5.2 VDC
12 VDC models: 12 – 16 VDC
24 VDC models: 24 – 28 VDC
Output regulation 1 %
Ripple and noise (20MHz bandwidth) <100 mV pk-pk
Electronic short circuit protection current limitation at 100 – 150 % typ.
(automatic recovery)
Overvoltage protection, trigger point 5 VDC model: 5.5 – 7.5 VDC
12 VDC models: 16 – 24 VDC
TBL 030-124, TBL 150-124: 30 – 37 VDC
TBL 015-124, TBL 060-124, TBL 090-124: 29 – 44 VDC
Hold-up time 115 VAC 230 VAC
min. 10 ms min. 20 ms
General Specifications
Temperature ranges – Operating –25°C to +70°C max.
– Storage –40°C to +85°C max.
Power derating 2.5 %/K above 60°C
Humidity (non condensing) 5 – 95 % rel. H
Temperature coefficient 0.02 %/K
Reliability, calculated MTBF at +25°C acc. to IEC 61709 TBL 015: >1.5 Mio h
TBL 060: >2.1 Mio h
all other models: >1.3 Mio h
Isolation voltage (60 s) – Input to Output 3000 VAC
Safety standards – UL certificate of compliance UL 508 listed
UL 1310, class II (15 – 90 W models)
– CB test certificate IEC 60950-1:2005 2nd Ed +A1:2009
– SIQ type approved EN 60950-1:2006 +Am1:2010 +Am11:2009
+Am12:201
EN 50178, EN 60204-1, EN 61558-2-16
– CSA certificate of compliance CAN/CSA-C22.2 No. 60950-1-07 2nd Ed
UL 60950-1 2nd Ed
– Certification documents www.tracopower.com/overview/tbl
Electromagnetic compatibility (EMC), emissions EN 61000-6-3
– Conducted RI suppression on input EN 55022 class B
– Radiated RI suppression EN 55022 class B
Electromagnetic compatibility (EMC), immunity EN 61000-6-2
– Electrostatic discharge (ESD) EN 61000-4-2 4 kV / 8 kV criteria B
– Radiated RF field immunity EN 61000-4-3 10 V/m criteria A
– Electrical fast transient / burst immunity EN 61000-4-4 ±2 kV criteria B
– Surge immunity line – ground EN 61000-4-5 2 kV criteria B
– Surge immunity line – line EN 61000-4-5 1 kV criteria B
– Immunity to conducted RF disturbances TBL 90/150: EN 61000-4-6 3 V criteria A
– Immunity to conducted RF disturbances other models: EN 61000-4-6 10 V criteria A
– Magnetic field immunity EN 61000-4-8 100 A/m criteria A
– Mains voltage dips and interruptions EN 61000-4-11
– Voltage Sag immunity SEMI F47-0706