LUCKY LIGHT
Part No. LL-S150WC Spec No. S/N-02011105D Page 3 of 4
Absolute Maximum Ratings at Ta=25℃
Parameter MAX. Unit
Power Dissipation 100 mW
Peak Forward Current
(1/10 Duty Cycle, 0.1ms Pulse Width) 100 mA
Continuous Forward Current 35 mA
Derating Linear From 50℃ 0.4 mA/℃
Reverse Voltage 5 V
Operating Temperature Range -40℃ to +80℃
Storage Temperature Range -40℃ to +80℃
Lead Soldering Temperature
[4mm(.157”) From Body] 260℃ for 5 Seconds
Electrical Optical Characteristics at Ta=25℃
Parameter Symbol Min. Typ. Max. Unit Test Condition
Luminous Intensity Iv --- 400 --- mcd If=20mA (Note 1)
Viewing Angle 2θ1/2 --- 140 --- Deg Note 2
x 0.20 0.27 0.34 --- IF=20mA (Note 3)
y 0.20 0.27 0.35 --- IF=20mA (Note 3)
Forward Voltage VF 2.8 3.6 4.0 V IF=20mA
Reverse Current IR --- --- 100 µA VR=5V
Note:
1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. It use many parameters that correspond to the CIE 1931 2°. X,Y, and Z are CIE 1931 2°values of
Red, Green and Blue content of the measurement.
lueGreend d
Y
X
x++
=
++
=Re Re
lueGreend Green
Y
Y
y++
=
++
=Re