Established: Feb.2015
DATA SHEET
Part No. MN63Y1212
HSON008-A-0202Package Code No.
4
About this manual
Organization
These specifications provide important information for users of the MN63Y1212, including an overview and
descriptions of functions.
Manual Configuration
Each section of this manual consists of a title, main text, and notes. The layout and definition of each section
are shown below.
1.1 UART
This section describes the UART specification.
1.1.1 Communication Specifications
Table 1-1 shows the UART specification of this RFID.
Table 1-1 UART Communication Specification
No flow control signal (RTS/CTS)Other
LSB-first
Data (8 bits)
Start bit (1bit)
Parity bit (1bit, even)
Stop bit (1bit) See Note below.
Character
transmission
1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400
bps
Data rate
Asynchronous, half-duplex (Only IRQ notification allows full-
duplex)
Data transfer
method
No flow control signal (RTS/CTS)Other
LSB-first
Data (8 bits)
Start bit (1bit)
Parity bit (1bit, even)
Stop bit (1bit) See Note below.
Character
transmission
1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400
bps
Data rate
Asynchronous, half-duplex (Only IRQ notification allows full-
duplex)
Data transfer
method
Note: In order to ensure the timing margin, when sending consequtive data from the host, use a
2-bit stop bit or set the interval between stop bit and next start bit to 1 bit or more.
Middle title
Small title
Text
Note
This is the Note.
Please read.
1.1 UART
This section describes the UART specification.
1.1.1 Communication Specifications
Table 1-1 shows the UART specification of this RFID.
Table 1-1 UART Communication Specification
No flow control signal (RTS/CTS)Other
LSB-first
Data (8 bits)
Start bit (1bit)
Parity bit (1bit, even)
Stop bit (1bit) See Note below.
Character
transmission
1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400
bps
Data rate
Asynchronous, half-duplex (Only IRQ notification allows full-
duplex)
Data transfer
method
No flow control signal (RTS/CTS)Other
LSB-first
Data (8 bits)
Start bit (1bit)
Parity bit (1bit, even)
Stop bit (1bit) See Note below.
Character
transmission
1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400
bps
Data rate
Asynchronous, half-duplex (Only IRQ notification allows full-
duplex)
Data transfer
method
Note: In order to ensure the timing margin, when sending consequtive data from the host, use a
2-bit stop bit or set the interval between stop bit and next start bit to 1 bit or more.
Middle title
Small title
Text
Note
This is the Note.
Please read.
DUMMY
Finding Desired Information
This manual provides two methods for finding desired information quickly and easily.
1. Consult the table of contents at the front of the manual to locate desired titles.
2. Chapter names are located at the top outer corner of each page, and section titles are located at the
bottom outer corner of each page.
Chapter 1
Overview
1
Chapter 2
Pin Descriptions
2
Chapter 3
Memory Map
3
Chapter 4
RF Communication Mode
4
Chapter 5
Interrupt Generation Function
5
Chapter 6
Electrical characteristics
6
Chapter 1 Overview
6
Contents
Chapter 1 Overview ................................................................... 9
1.1 Features ............................................................................................................................ 10
1.2 Block Diagram ................................................................................................................. 11
1.3 Operation Mode ............................................................................................................... 12
1.4 Encrypted Communication Function ............................................................................... 13
Chapter 2 Pin Descriptions ...................................................... 15
2.1 List of Pins ....................................................................................................................... 16
2.2 Pin Descriptions ............................................................................................................... 18
2.3 Connection Example ........................................................................................................ 19
Chapter 3 Memory Map ........................................................... 21
3.1 Block Configuration ........................................................................................................ 22
3.2 Physical Memory Map ..................................................................................................... 23
3.3 System Area ..................................................................................................................... 24
3.3.1 Parameter Specifications ........................................................................................... 24
3.3.2 Enabling System Area ............................................................................................... 28
3.4 Address Correspondence ................................................................................................. 29
Chapter 4 RF Communication Mode ....................................... 31
4.1 RF Communication Mode Sequence ............................................................................... 32
4.2 JISX6319-4 Specification ................................................................................................ 33
4.2.1 Communication Specifications .................................................................................. 33
4.2.2 Frame Format ............................................................................................................ 33
4.2.3 State Transition Diagram ........................................................................................... 34
4.2.4 Flow Chart ................................................................................................................. 34
4.2.5 Various Settings ........................................................................................................ 36
4.2.5.1 System Code ....................................................................................................... 36
4.2.5.2 PICC (Proximity IC Card) Identifier .................................................................. 36
4.2.5.3 Response Time Descriptor .................................................................................. 36
4.2.5.4 Anticollision ........................................................................................................ 37
4.2.5.5 Service ................................................................................................................. 37
4.2.5.6 Block ................................................................................................................... 38
4.2.5.7 Block List ............................................................................................................ 39
4.2.5.8 Status Flag ........................................................................................................... 41
4.2.6 Command .................................................................................................................. 42
4.2.6.1 REQ ..................................................................................................................... 43
4.2.6.2 READ .................................................................................................................. 44
4.2.6.3 WRITE ................................................................................................................ 46
4.2.7 NDEF ......................................................................................................................... 47
7
4.2.7.1 MEMORY MAP ................................................................................................. 47
4.2.7.2 Setup of System CodeSC ............................................................................ 47
4.2.7.3 Setup of Attribute Information Block ................................................................. 48
4.2.7.4 NDEF FILE ......................................................................................................... 48
4.3 ISO/IEC14443 TypeB Specification ............................................................................... 50
4.3.1 Communication Specification ................................................................................... 50
4.3.2 Frame Format ............................................................................................................ 50
4.3.3 Protocol Control ........................................................................................................ 51
4.3.4 Block Control ............................................................................................................ 52
4.3.5 Upper Command Format ........................................................................................... 53
4.3.6 State Transition Diagram ........................................................................................... 55
4.3.7 Flow Chart ................................................................................................................. 56
4.3.8 Various Settings ........................................................................................................ 57
4.3.8.1 AFI (Application Family Identifier) ................................................................... 57
4.3.8.2 PUPI (Pseudo-Unique PICC Identifier) .............................................................. 57
4.3.8.3 FWI (Frame Waiting Time Integer) .................................................................... 58
4.3.8.4 File System .......................................................................................................... 58
4.3.8.5 Address................................................................................................................ 59
4.3.8.6 Data ..................................................................................................................... 59
4.3.8.7 Status Word ......................................................................................................... 61
4.3.9 Command .................................................................................................................. 62
4.3.9.1 REQB/WUPB ..................................................................................................... 63
4.3.9.2 ATTRIB .............................................................................................................. 65
4.3.9.3 HLTB .................................................................................................................. 67
4.3.9.4 SELECT .............................................................................................................. 68
4.3.9.5 READ .................................................................................................................. 70
4.3.9.6 WRITE ................................................................................................................ 71
4.3.10 NDEF ....................................................................................................................... 72
4.3.10.1 Memory Map..................................................................................................... 72
4.3.10.2 NDEF Tag Application Selection ..................................................................... 73
4.3.10.3 CC File .............................................................................................................. 73
4.3.10.4 NDEF File ......................................................................................................... 73
Chapter 5 Interrupt Generation Function ................................. 75
5.1 Interrupt Source ............................................................................................................... 76
Chapter 6 Electrical characteristics ......................................... 77
Chapter 1 Overview
9
Chapter 1
Overview
1
Chapter 1 Overview
10
1.1 Features
The MN63Y1212 is an LSI for RFID (Radio Frequency Identification), which features the following:
Built-in 4-Kbit FeRAM non-volatile memory with fast write and low power consumption.
RF interface compliant with JISX6319-4 (212 kbps / 424 kbps) and ISO/IEC14443 TypeB (106 kbps / 212
kbps) of the 13.56-MHz contactless IC card standards.
Batteryless RF communication
Encryption communication function that uses AES (128 bits) private-key cryptosystem
Supply voltage range: 1. V to 3.6 V
Chapter 1 Overview
11
1.2 Block Diagram
Figure 1-1 shows a block diagram.
This RFID provides RF interface for contactless communication with external reader/writer, serial interface for
contact communication with external host, control logic for command processing and various controls, 2-Kbit
transmit/receive buffer for RF communication, 4-Kbit FeRAM non-volatile memory, and AES cryptosystem.
Figure 1-1 Block Diagram
RF
I/F
FeRAM
(4 Kbit)
Crypto
(AES)
R/W
(External)
RFID
Control
Logic
RF
Com.
Buffer
(2Kbit)
RF
I/F
FeRAM
(4 Kbit)
Crypto
(AES)
R/W
(External)
RFID
Control
Logic
RF
Com.
Buffer
(2Kbit)
Chapter 1 Overview
12
1.3 Operation Mode
This RFID provides the one operation modes of RF communication.
Figure 1-2 gives the overview of each operation mode.
RF communication mode
This mode is used for communication between reader/writer and RFID. Reader/writer is the master and RFID
is the slave. Key commands are read and write commands to FeRAM of RFID. This mode allows batteryless
operations that use only the power supplied from the antenna of reader/writer.
For more information about RF communication mode, see Chapter 4 RF Communication Mode.
Figure 1-2 Operation Mode
R/W RFID
Master Slave
RF communication mode
R/W RFID
Master Slave
R/W RFID
Master Slave
RF communication mode
Chapter 1 Overview
13
1.4 Encrypted Communication Function
This RFID provides an encrypted communication function.
Figure 1-3 depicts its functionality in the one operation mode.
For communication between reader/writer and RFID, RF communication mode allows both encrypted and
plaintext (unencrypted) communications
Encrypted communication uses Message Authentication Code (MAC) to detect falsified communication data
and to prevent access from illegal readers/writers.
Figure 1-3 Encrypted Communication Function
R/W RFID
RF communication mode
Master Slave
Encrypted or plaintextcommunication
R/W RFID
RF communication mode
Master Slave
Encrypted or plaintextcommunication
Chapter 2
Pin Descriptions
2
Chapter 2 Pin Descriptions
16
2.1 List of Pins
Table 2-1 shows a list of pins of this RFID and Figure2-1 illustrates the pin assignments of this RFID.
Table 2-1 List of Pins
Pin No.
Name
I/O
Output type
Description
1
VB
I/O
-
Connected to coil
2
N.C.
-
-
TEST PIN. Please connect with opening or a ground.
3
VSS
-
GND
Ground
4
VA
I/O
-
Connected to coil
5 NIRQ Output Open Drain
Interrupt request output
At the time of use: Please carry out a pull-up with the
power supply of IC which uses NIRQ.
At the time of intact:Please process like a No. 2 pin.
6
N.C.
-
-
TEST PIN. Please process like a No. 2 pin.
7
N.C.
-
-
TEST PIN. Please process like a No. 2 pin.
8 VDDA - Power
Internal analog power supply (Connect a capacitor
between this pin and VSS.)
Figure 2-1 Pin Assignments (SON8)
V
B
1 2 3 4
8 7 6 5
TOP VIEW
N
C
V
S
S
V
A
N
I
R
Q
N
C
N
C
V
D
D
A
V
B
1 2 3 4
8 7 6 5
TOP VIEW
N
C
V
S
S
V
A
N
I
R
Q
N
C
N
C
V
D
D
A
Chapter 2 Pin Descriptions
17
Unitmm
Figure 2-2 Outside drawing (SON8)
2.00
2.00
0.50×31.50
1.70
1.10
0.25
0.25
1234
5 6 7 8
2.00
2.00
TOP VIEW
TOP VIEW BOTTOM VIEW
BOTTOM VIEW
4321
5678
0.50
0.50
0.50
0.50
Chapter 2 Pin Descriptions
18
2.2 Pin Descriptions
Coil connection pins (VA, VB)
Used for connecting an antenna coil. Also connect a resonance capacitor for adjusting resonance frequency.
Ground (VSS)
A reference power supply pin. Connect to the ground of the host CPU.
Internal analog power supply (VDDA)
An internal analog power supply pin. Connect a capacitor (see the Product Standards for its value) between
VDDA and VSS pins as close as possible to the RFID. It is unnecessary to apply an external power to this pin.
Interrupt request (NIQR)
An N-ch open drain pin to request an interrupt to the host and should be pulled up externally.
N.C. pin
Not connected. Leave it open in normal operation
Chapter 2 Pin Descriptions
19
2.3 Connection Example
Figure 2- gives a connection example.
Please arrange the capacity between power supplies of VDDA near the PKG as much as possible
Figure 2-3 Connection Example
MN63Y1212
VA
VB VSS
VDDA
0.1μF2.2μF
NIRQ
VDD
MN63Y1212
VA
VB VSS
VDDA
0.1μF2.2μF
NIRQ
VDD
MN63Y1212
VA
VB VSS
VDDA
0.1μF2.2μF
MN63Y1212
VA
VB VSS
VDDA
0.1μF2.2μF
In case of NOT using NIRQ
In case of using NIRQ
Chapter 3
Memory Map
3
Chapter 3 Memory Map
22
3.1 Block Configuration
Figure 3-1 illustrates the block configuration of 4-Kbit FeRAM.
This LSI consists of 32 FeRAM blocks. The size of a block is 16 bytes.
The memory consists of two areas: user and system areas.
The system area stores RF-communication-related parameters and memory-access-control-related data, etc.
Block
Area
Type
0
16-byte FeRAM
User area
1
16-byte FeRAM
2
16-byte FeRAM
3
16-byte FeRAM
24
16-byte FeRAM
25
16-byte FeRAM
26
16-byte FeRAM
27
16-byte FeRAM
System area
28
16-byte FeRAM
29
16-byte FeRAM
30
16-byte FeRAM
31
16-byte FeRAM
Figure 3-1 4-Kbit FeRAM Block Configuration
Chapter 3 Memory Map
23
3.2 Physical Memory Map
Figure 3-2 presents the physical memory map.
Block
Address
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
0x8
0x9
0xA
0xB
0xC
0xD
0xE
0xF
0
0x0000
User Area
1
0x0010
User Area
2
0x0020
User Area
3
0x0030
User Area
4
0x0040
User Area
5
0x0050
User Area
6
0x0060
User Area
7
0x0070
User Area
8
0x0080
User Area
9
0x0090
User Area
10
0x00A0
User Area
11
0x00B0
User Area
12
0x00C0
User Area
13
0x00D0
User Area
14
0x00E0
User Area
15
0x00F0
User Area
16
0x0100
User Area
17
0x0110
User Area
18
0x0120
User Area
19
0x0130
User Area
20
0x0140
User Area
21
0x0150
User Area
22
0x0160
User Area
23
0x0170
User Area
24
0x0180
User Area
25
0x0190
User Area
26
0x01A0
User Area
27
0x01B0
CONFIG
28
0x01C0
CONFIG
29
0x01D0
CONFIG
30
0x01E0
SC
IDM
PMM
AFI
FWI
HW1
31
0x01F0
RORF
ROSI
SECURITY
TNPRM
HW2
CONFIG
Figure 3-2 Physical Memory Map
Chapter 3 Memory Map
24
3.3 System Area
This section describes the system area.
3.3.1 Parameter Specifications
Each parameter of the system area is shown below.
All addresses and block numbers used in this section correspond to the physical address in Figure 3-2.
RORF (4 bytes)
RORF and SECURITY are an area to specify whether read/write or read-only is to be used in accessing the
block by memory access commands in RF communication mode. Table 3-1 describes RORF and SECURITY
setting, and Table 3-2 shows RORF setting bits and corresponding block numbers. By default, all values are
0. Set all reserved bits to 0. Refer to Table 3-5 for SECURITY
Table 3-1 RORF and SECURITY Setting
Value
Meaning -
RORF SECURITY
Plaintext
communication
Encryption
communication
0
0
READ/WRITE
READ/WRITE
0
1
Prohibition
READ/WRITE
1
0
READ ONLY
READ ONLY
1
1
READ ONLY
READ/WRITE
Table 3-2 RORF Setting Bits and Corresponding Block Numbers
Address
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0x01F0
Block7
Block6
Block5
Block4
Block3
Block2
Block1
Block0
0x01F1
Block15
Block14
Block13
Block12
Block11
Block10
Block9
Block8
0x01F2
Block23
Block22
Block21
Block20
Block19
Block18
Block17
Block16
0x01F3
Reserved
Reserved
Reserved
Reserved
Reserved
Block26
Block25
Block24
ROSI (4 bytes)
ROSI is reserved Set all bits to 0.
Chapter 3 Memory Map
25
SECURITY (4 bytes)
RORF and SECURITY are an area to specify whether to enable plaintext (unencrypted) communication
access by memory access commands in RF communication mode. This setting is valid only in RF
communication mode. Table 3-31 describes RORF and SECURITY setting, and Table 3-33 shows SECURITY
setting bits and corresponding block numbers. By default, all values are 0. Set all reserved bits to 0.
Table 3-3 SECURITY Setting Bit and Corresponding Block Number
Address
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0x01F8
Block7
Block6
Block5
Block4
Block3
Block2
Block1
Block0
0x01F9
Block15
Block14
Block13
Block12
Block11
Block10
Block9
Block8
0x01FA
Block23
Block22
Block21
Block20
Block19
Block18
Block17
Block16
0x01FB
Reserved
Reserved
Reserved
Reserved
Reserved
Block26
Block25
Block24
HW1 (2 bytes)
HW1 is an area to store various setting data related to the hardware of this RFID.
Table 3-4 describes the HW1 parameter. For the setting of the RF communication protocol RFTYPE, see
Table 3-5. For the setting of IDM data selection IDMSEL, see Table 3-6.
Table 3-4 HW1 Parameter
Address
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0x01EE
Reserved
RFTYPE
Reserved
IDMSEL
0x01EF
Reserved
Reserved(Please set 0x54”)
Table 3-5 RFTYPE Setting for Selecting RF Communication Protocol
Bit 5
Bit 4
Meaning
0 0
Use both JISX6319-4 and ISO/IEC14443 TypeB. (Automatic protocol detection)
(default)
0
1
Use JISX6319-4 only. (ISO/IEC14443 TypeB interface disabled)
1
0
Use ISO/IEC14443 TypeB only. (JISX6319-4 interface disabled)
1
1
Reserved (When this field is specified, a default setting will be applied.)
Table 3-6 IDMSEL Setting for Selecting IDM Data
Bit 0
Meaning
0
Use the fixed values (All-0) as JISX6319-4 PICC identifier or ISO/IEC14443 TypeB PICC.
Values written in the system area are not used. (default)
1
Use the values written in the system area as JISX6319-4 PICC identifier or ISO/IEC14443
TypeB PICC.
TNPRM (1 byte)
TNPRM is reserved.
Table 3-7 TNPRM Parameter
Address
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0x01FC
Reserved(Please set 0x4”)
Reserved (Please set 0x7”)
Chapter 3 Memory Map
26
HW2 (1 byte)
HW2 is reserved.
.
Table 3-8 HW2 Parameter
Address
Bit 7
Bit 6
Bit 5
Bit 4
Bi t3
Bit 2
Bit 1
Bit 0
0x01FD
Reserved
(Please set 0x3”)
Reserved
(Please set 0x3”)
Reserved
IRQSEL
IRQSEL
IRQSEL is used for IRQ notification to add the condition of generating an interrupt to the NIRQ pin.
There are two user-selectable additional interrupt sources, RF communication detection or reader/writer
magnetic-field detection. In addition, RF communication can be detected when RF response transmission is
completed or when a write to FeRAM with the RF command is completed (selectable).
For more information about interrupt source, see Section 5 Interrupt Generation Function
The IRQSEL settings are as follows.
Table 3-9 IRQSEL Setting for IRQ Notification
Bit 2
Bit 1
Bit 0
Meaning
0 0 X
Do not generate an interrupt when RF response transmission is completed or when a
write to FeRAM with the RF command is completed.
0
1
X
Reserved
1
0
X
Generate an interrupt when RF response transmission is completed.
1
1
X
Generate an interrupt when a write to FeRAM with the RF command is completed.
X
X
0
Do not generate an interrupt when a magnetic field is detected.
X
X
1
Generate an interrupt when a magnetic field is detected.
SC (2 bytes)
SC is used as the JISX6319-4 system code (2 bytes). For more information about system code, see Section
4.2.5.1 System Code.
Table 3-10 SC Parameter
Address
0x01E0
0x01E1
JISX6319-4
system code (2 bytes)
D0 D1
Default
0xAA
0xFF
IDM (8 bytes)
IDM is used as JISX6319-4 PICC (Proximity IC Card) identifier (8 bytes). The PUPI (Pseudo-Unique PICC
Identifier) (4 bytes) of ISO/IEC14443 TypeB is shared with the lower 4 bytes of the JISX6319-4 PICC
identifier. For information about JISX6319-4 PICC identifier, see Section 4.2.5.2 PICC (Proximity IC Card)
Identifier, and for information about ISO/IEC14443 TypeB PUPI, see Section 4.3.8.2 PUPI.
Chapter 3 Memory Map
27
Table 3-11 IDM Parameter
Address
0x01E2
0x01E3
0x01E4
0x01E5
0x01E6
0x1E7
0x1E8
0x01E9
JISX6319-4
PICC identifier (8 bytes)
D0 D1 D2 D3 D4 D5 D6 D7
Default
0x02
0xFE
0x00
0x00
0x00
0x00
0x00
0x00
ISO/IEC14443TypeB
PUPI (4 bytes)
Reserved D0 D1 D2 D3
Default
-
-
-
-
0x00
0x00
0x00
0x00
Note: In order to validate the value written in the system area IDM, the HW parameter's IDMSEL must be set
to 1. See Table 3-6
PMM (2 bytes)
Of the JISX6319-4 response time descriptor (8 bytes), PMM is an area (2 bytes) to specify maximum wait time
for the response to READ/WRITE commands. See Section 4.2.5.3 .
Table 3-12 PMM Parameter
Address
0x01EA
0x01EB
JISX6319-4
Response time descriptor (2 bytes)
D5 D6
Default
0xFF
0xFF
AFI (1 byte)
AFI is an area to specify AFI (Application Family Identifier) of ISO/IEC14443 TypeB. See Section 4.3.8.1
AFI.
Table 3-13 AFI Parameter
Address
0x01EC
ISO/IEC14443 TypeB
AFI (1 byte)
D0
Default
0x00
FWI (1 byte)
FWI is an area to specify FWI (Frame Waiting time Integer) of ISO/IEC14443 TypeB. See Section 4.3.8.3
FWI.
Table 3-14 FWI Parameter
Address
0x01ED
ISO/IEC14443 TypeB
FWI (1 byte)
D0
Default
0xE0
CONFIG
See the Administrator's Manual.
Chapter 3 Memory Map
28
3.3.2 Enabling System Area
In order to enable parameters in the system area, CFEN and BCC (see the Administrator's Manual) of the
system area must be set to valid values. If CFEN and BCC are not set to valid values, default values defined
by each parameter will be applied.
Table 3-15 lists the setting application timings after rewriting parameters in the system area while CFEN and
BCC are enabled. New parameter setting is applied to RORF, ROSI, and SECURITY immediately after
rewriting, and applied to other parameters after turning power supply ON from OFF.
Table 3-15 Parameter Application Timing
A timing at which new parameter setting
is applied after rewriting parameters
when CFEN is enabled.
RORF
Apply immediately after rewrites.
ROSI
Apply immediately after rewrites.
SECURITY
Apply immediately after rewrites.
HW1
Apply after turning power ON from OFF
following rewrites.
TNPRM
Apply after turning power ON from OFF
following rewrites.
HW2
Apply after turning power ON from OFF
following rewrites.
SC
Apply after turning power ON from OFF
following rewrites.
IDM
Apply after turning power ON from OFF
following rewrites.
PMM
Apply after turning power ON from OFF
following rewrites.
AFI
Apply after turning power ON from OFF
following rewrites.
FWI
Apply after turning power ON from OFF
following rewrites.
CONFIG
See the Administrator's Manual.
Note: Power OFF means power supplies from RF interface are OFF.
Chapter 3 Memory Map
29
3.4 Address Correspondence
Figure 3-3 presents the physical address and the corresponding address of each communication mode.
Physical address
RF communication mode
JISX6319-4
ISO/IEC14443
Block0
0x0000
Block No.
0
D0
0x0000
0x0001
D1
0x0001
0x0002
D2
0x0002
0x0003
D3
0x0003
0x0004
D4
0x0004
0x0005
D5
0x0005
0x0006
D6
0x0006
0x0007
D7
0x0007
0x0008
D8
0x0008
0x0009
D9
0x0009
0x000A
Da
0x000A
0x000B
Db
0x000B
0x000C
Dc
0x000C
0x000D
Dd
0x000D
0x000E
De
0x000E
0x000F
Df
0x000F
Block1
0x0010
Block No.
1
D0
0x0010
0x0011
D1
0x0011
0x001E
De
0x001E
0x001F
Df
0x001F
Block31
0x01F0
Block No.
31
D0
0x01F0
0x01F1
D1
0x01F1
0x01FE
De
0x01FE
0x01FF
Df
0x01FF
Figure 3-3 Address Correspondence
Chapter 4
RF Communication Mode
4
Chapter 4 RF Communication Mode
32
4.1 RF Communication Mode Sequence
Figure 4-1 illustrates the sequence in RF communication mode. Each sequence is described below.
SNo.1: A reader/writer sends an RF communication mode command to the RFID.
SNo.2: Once the RFID receives the RF communication mode command described in SNo.1, it processes the
command and then sends the result to the reader/writer as the response to the command.
Figure 4-1 RF Communication Mode Sequence
R/W HostRFID
RF communication mode command
SNo.1
Response to RF communication mode command
SNo.2
Chapter 4 RF Communication Mode
33
4.2 JISX6319-4 Specification
This section describes the JISX6319-4 specification of this RFID.
4.2.1 Communication Specifications
Table 4-1 shows the JISX6319-4 specification of this RFID.
Table 4-1 JISX6319-4 Communication Specification
Carrier frequency
13.56 MHz
Modulation mode,
Bit encoding
R/W→RFID
ASK10%, Manchester encoding
RFID→R/W
Load modulation, Manchester encoding
Data rate
212 kbps / 424 kbps
Character transmission
MSB-first
Data (8 bits)
No start bit
No parity bit
No stop bit
No spare time between characters
4.2.2 Frame Format
Figure 4-2 illustrates the JISX6319-4 frame format and Table 4-2 defines the fields.
Figure 4-2 JISX6319-4 Frame Format
Table 4-2 JISX6319-4 Field Definition
Field name
Byte length
Definition
Preamble
6
0x000000000000
Synchronous code
2
0xB24D
LEN
1
n (data field length) + 1
Data field
n
Command message or Response message
Error-detecting code 2
Initial value: 0000,
Generating polynomial: CRC of X
16
+X
12
+X
5
+1
0 to 254 bytes
Data field
2 bytes
Synchronous code
2 bytes CRC1 byte6 bytes
Error-detecting code
End field
LEN
Information field
Preamble
Start field
0 to 254 bytes
Data field
2 bytes
Synchronous code
2 bytes CRC1 byte6 bytes
Error-detecting code
End field
LEN
Information field
Preamble
Start field
Data length
Error-detecting signal
(LEN+10) bytes
Chapter 4 RF Communication Mode
34
4.2.3 State Transition Diagram
Figure 4-3 shows the state transition diagram for the JIX6319-4 PICC of this RFID.
Figure 4-3 State Transition Diagram of JISX6319-4 PICC
4.2.4 Flow Chart
Figure 4-4 gives the flow chart for JIX6319-4 command processing of this RFID.
Figure 4-4 JISX6319-4 Flow Chart of Command Processing
POWER OFF
MODE0
Magnetic field ON/ No response
REQ/ Response
READ/ Response
WRITE/ Response
Unimplemented command/ No response
CRC error/ No response
Service count error/ Response with an error
Service file specification error/ Response with an error
Block count error/ Response with an error
Block specification error/ Response with an error
Self-diagnosis error/ Response with an error
Magnetic field OFF
Magnet field ON
Mode 0
REQ
Send a response to request.
Yes
No
READ
WRITE
PICC identifier identified?
Send a response.
Yes
No
Any of the following conditions identified?
System code is 0xFFFF.
System code is 0xAAFF and
upper 1 byte (0xAA) are matched.
System code of 2 bytes are matched.
Other
Magnet field ON
Mode 0
REQ
Send a response to request.
Yes
No
READ
WRITE
PICC identifier identified?
Send a response.
Yes
No
Any of the following conditions identified?
System code is 0xFFFF.
System code is 0xAAFF and
upper 1 byte (0xAA) are matched.
System code of 2 bytes are matched.
Other
Chapter 4 RF Communication Mode
36
4.2.5 Various Settings
This section describes the parameter settings and operation specifications based on JISX6319-4 for this
RFID.
4.2.5.1 System Code
System code is a parameter specified by the REQ command that is used to identify the RFID. Figure 4-5
shows the system code. The system code is set by the value of the system area SC for FeRAM.
The response operation to the REQ command by system code is shown in Table 4-3.
Figure 4-5 System Code
Table 4-3 Response to REQ Command by System Code
REQ command
System code setting value
RFID's response to REQ command
0xFFFF
Responds regardless of the system area SC setting
0xAAFF
When the value of the upper 1 byte of the SC system area
is 0xAA, the RFID responds regardless of the value of the
lower 1 byte.
Other
Responds only when the setting value of the REQ
command's system code matches the value specified in
the system area SC (and does not respond in other cases).
4.2.5.2 PICC (Proximity IC Card) Identifier
The PICC (Proximity IC Card) identifier is a data used to identify RFID, and is included in the response to the
REQ command. Figure 4-6 illustrates the PICC identifier's format. The PICC identifier (8 bytes) is set in the
system area IDM.
Figure 4-6 PICC Identifier Format
4.2.5.3 Response Time Descriptor
The response time descriptor is used to specify the maximum wait time until the RFID sends a response after
reader/writer sends a command, and is included in the response to the REQ command. Figure 4-7 illustrates
SC
D1D0
SC
D1D0
System code
IDM
D7D6D5D4D3D2D1D0
IDM
D7D6D5D4D3D2D1D0
PICC identifier
Chapter 4 RF Communication Mode
37
the response time descriptor's format. In hardware, D0, D1, and D7 bytes are set to FFh and D2 to D4 bytes
are set to 00h. The response time calculation parameters D5 and D6 bytes are the values of the system area.
Table 4-4 shows the response time calculation parameter and corresponding command.
Figure 4-7 Response Time Descriptor Format
Table 4-4 Response Time Calculation Parameter and Corresponding Command
Response time calculation parameter
Command
D5
READ
D6
WRITE
Figure 4-8 shows the response time calculation parameter's format.
Figure 4-8 Response Time Calculation Parameter Format
The response time is calculated by the following formula:
Response time = T × [ (B + 1) × n + (A + 1) ] × 4E
T: 256 × 16/fc (approx. 0.302 ms)
n: No. of blocks or No. of files of command parameter.
4.2.5.4 Anticollision
JISX6319-4 uses the time slot method for anti-collision (prevention of collision). This RFID always responds
according to the first slot.
4.2.5.5 Service
This RFID does not implement the concept of service based on JISX6319-4.
However, it is possible to specify multiple services using a command service list. Table 4-5 shows the
available maximum number of services. When specifying multiple services in the service list, the values of
service list must be set to the same value.
Response time descriptor
Response time calculation parameter
0xFFPMM0x000x000x000xFF0xFF
D7D6D5D4D3D2D1D0
0xFFPMM0x000x000x000xFF0xFF
D7D6D5D4D3D2D1D0
Real number AReal number BExponent E
Bit 0Bit 1Bit 2Bit 3Bit 4Bit 5Bit 6Bit 7
Real number AReal number BExponent E
Bit 0Bit 1Bit 2Bit 3Bit 4Bit 5Bit 6Bit 7
msb lsb
Chapter 4 RF Communication Mode
38
Table 4-5 Maximum Number of Services
Command
Maximum No. of services
READ
15
WRITE
11
Note: The RFID responds with an error when multiple services are not set to the same service file value.
4.2.5.6 Block
JISX6319-4 uses data of 16-byte blocks. Block number is used to specify each block. Figure 4-9 shows the
block element of 2 bytes and Figure 4-10 shows the block element of 3 bytes. All of bits 6 to 4 of byte D0 for
access mode setting should be set to 0 in this RFID; otherwise the RFID responds with an error.
Figure 4-9 Block Element of 2 Bytes
Figure 4-10 Block Element of 3 Bytes
1
-
Bit
7
Block number designation
Dont care
000
This RFID’s
setting value
Block number
Order of service
code
Access mode
Definition
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
1
Bit
2
Bit
3
Bit
4
Bit
5
Bit
6
1
-
Bit
7
Block number designation
Dont care
000
This RFID’s
setting value
Block number
Order of service
code
Access mode
Definition
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
1
Bit
2
Bit
3
Bit
4
Bit
5
Bit
6
msb lsb msb lsb
D0 D1
0
-
Bit
7
Mode setting
00000Block number designation
Dont care
000
This RFID’s
setting value
Block number
Order of service
code
Access mode
Definition
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
1
Bit
2
Bit
3
Bit
4
Bit
5
Bit
6
0
-
Bit
7
Mode setting
00000Block number designation
Dont care
000
This RFID’s
setting value
Block number
Order of service
code
Access mode
Definition
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
1
Bit
2
Bit
3
Bit
4
Bit
5
Bit
6
msb lsb msb lsb msb lsb
D0 D1 D2
Chapter 4 RF Communication Mode
39
This RFID uses a block number to specify encrypted communication. Table 4-6 shows the mode settings for
encrypted communication. Bits 2 to 0 of byte D2 in 3-byte block element format are used. All of bits 7 to 3 of
byte D2 should be set to 0; otherwise the RFID responds with an error.
Table 4-6 Mode Settings
Block element format
Byte D2 of block No.
Meaning
Bit 2 Bit 1 Bit 0
Communication
mode
Encrypted communication
2 bytes
-
-
-
RF communication
mode
Plaintext (unencrypted)
communication
3 bytes
0
0
0
0 1 0
Encrypted communication
(private key)
0 1 1
Encrypted communication
(family key)
0
0
1
Reserved (Setting this field causes an error.)
1
0
0
Reserved (Setting this field causes an error.)
1
1
0
1
1
1
1
0
1
Table 4-7 shows the available maximum number of blocks. For READ command, the number is 13 for
plaintext (unencrypted) communication in RF communication mode. The maximum number of blocks for
WRITE command depends on the number of services.
Table 4-7 Maximum Number of Blocks
Command
Communication
mode
Encrypted communication No. of services
Maximum No.
of blocks
READ
RF communication
mode
Plaintext (unencrypted)
communication
1 to 15 15
Encrypted communication
1 to 15 15
WRITE RF communication
mode
Plaintext (unencrypted)
communication, Encrypted
communication
1 to 8
12
9 to 11 11
Note: Encrypted communication uses 2 blocks for its parameter, so the available number of blocks for data is
"the value listed in Table 4-7 – 2."
4.2.5.7 Block List
For encrypted communication how to specify block list is slightly different from the JISX6319-4 specification.
Figure 4-11 shows the block list referenced from this RFID.
(1) Plaintext (unencrypted) communication in RF communication mode: The block number of block list can be
set freely. The RFID references to all block numbers.
(2) Encrypted communication in RF communication mode : The block number to access is specified using the
block numbers between first and (m-2)th in the block list. The last two block numbers are dummy. The block
number of block list should be set in ascending order. The RFID checks that the block number is set in
ascending order and if not, it responds with an error.
Chapter 4 RF Communication Mode
40
Note: When specifying multiple blocks, communication mode (RF communication mode) and encrypted
communication for all blocks should be configured to the same setting; if not, the RFID responds with
an error.
Note: When setting block numbers in ascending order, set to 0x00 following the block number 0xFF (and set
to 0x01 following 0x00). Mode setting (bits 2 to 0 of byte D2) for all blocks should be set to the same
value.
Figure 4-11 Block List Referenced from this RFID
In addition, for encrypted communication, the structure of data is also slightly different from the JISX6319-4
specification. Figure 4-12 shows the block data structure.
(1) Plaintext (unencrypted) communication treats all block data as actual data.
(2) In encrypted communication, of the number of blocks m, the first block data is IV (Initial Vector) to be used
for encryption, data from second to (m-1)th blocks are actual data, and the last block data is MAC value for
Message Authentication Code (MAC).
Figure 4-12 Block Data Structure
(1) Plaintext
(unencrypted)
communication
(2) Encrypted
communication
Data m... Data (m-1)Data 3Data 2Data 1
Block data
Data m... Data (m-1)Data 3Data 2Data 1
Block data
Actual data
MAC value
MAC value... Data (m-2)Data 2Data 1IV
Block data
MAC value... Data (m-2)Data 2Data 1IV
Block data
Actual data
IV
Size specified by the number of blocks
Size specified by the number of blocks
(1)
Plaintext
(unencrypted)
communication
in RF
communication mode
Block number can be set freely.
Block element m
(Block No. f)
Block element (m-1)
(Block No. e)
... Block element (m-2)
(Block No. d)
Block element 3
(Block No. c)
Block element 2
(Block No. b)
Block element 1
(Block No. a)
m
Block list
No. of
blocks
Block element m
(Block No. f)
Block element (m-1)
(Block No. e)
... Block element (m-2)
(Block No. d)
Block element 3
(Block No. c)
Block element 2
(Block No. b)
Block element 1
(Block No. a)
m
Block list
No. of
blocks
(2)
Encrypted
communication
in RF
communication
mode
Set the block numbers in ascending order from the first block.Set the first block.
Block element m
(Block No. a+m-1)
Block element (m-1)
(Block No. a+m-2)
... Block element (m-2)
(Block No. a+m-3)
Block element 3
(Block No. a+2)
Block element 2
(Block No. a+1)
Block element 1
(Block No. a)
m
Block list
No. of
blocks
Block element m
(Block No. a+m-1)
Block element (m-1)
(Block No. a+m-2)
... Block element (m-2)
(Block No. a+m-3)
Block element 3
(Block No. a+2)
Block element 2
(Block No. a+1)
Block element 1
(Block No. a)
m
Block list
No. of
blocks
Dummy block
Chapter 4 RF Communication Mode
41
4.2.5.8 Status Flag
Table 4-8 lists the meanings of status flags.
Table 4-8 Status Flag
Status flag 1
Status flag 2
Meaning
Description
0x00
0x00
Normal end
Terminated normally.
0xFF
0x50
unmounted mode
mode is un-mounting.
0xFF
0x51
unmounted mode
mode is un-mounting.
0xFF 0xA1
Service count
specification error
The number of service files was out of the
specification.
0xFF 0xA2
Block count specification
error (*)
The number of blocks was out of the
specification.
0xFF 0xA3
Service count
specification error
Some settings for multiple service were
different from the specification.
0xFF 0xA5 Block specification error
Illegal access mode setting (except All-0)
Illegal mode setting (RFU setting)
Block number was specified outside FeRAM.
Ascending order was not used to specify
block numbers in encrypted communication.
0xFF 0x60 Self-diagnosis error
(*)
Write access to FeRAM-Read-Only area
Plaintext (unencrypted) command access to
Encrypted-communication-enable-only area
(*) For more information about these errors, see the Administrator's Manual.
Chapter 4 RF Communication Mode
42
4.2.6 Command
Table 4-9 lists the JISX6319-4 commands supported by this RFID.
Subsequent sections describe each command in detail.
Table 4-9 JISX6319-4 Command List
Name
Code Description
REQ
0x00
Reader/writer identifies RFID with this command.
READ
0x06
Reads data of RFID from reader/writer
WRITE
0x08
Writes data to RFID from reader/writer
Chapter 4 RF Communication Mode
43
4.2.6.1 REQ
Purpose
Reader/writer identifies RFID with this command.
Command message
Format
Command code
System code
Request code
Timeslot
1 byte
2 bytes
1 byte
1 byte
Data field
Field
Setting
Remarks
Command code
0x00
System code
0xFFFF: Identifies all RFIDs.
0xAAFF: Identifies RFID compliant with
JIXS6319-4, regardless of category.
Other: The RFID corresponding to the
specified system code responds.
Request code
0x00: No request
0x01: Additional system code request
0x02: Additional transmission protocol
capability request
When values other than the
values on the left column are
set, the RFID treats this field
as 0x00 (no request)
Timeslot
0x00: One slot
This RFID always treats this
field as 0x00.
Response message
Format
Response code
PICC identifier
Response time
descriptor
Request data
1 byte
8 bytes
8 bytes
0 or 2 bytes
Data field
Field
Output value
Remarks
Response code
0x01
PICC identifier
See 4.2.5.2 PICC (Proximity IC Card) Identifier.
Response time
descriptor
See 4.2.5.3 Response Time Descriptor
Request data
Request code 0x00: Request data 0 bytes (No
additional data)
Request code 0x01: Adds system code.
Request code 0x02: 0x0083 (212 kbps, 424
kbps, automatic data rate detection supported)
Chapter 4 RF Communication Mode
44
4.2.6.2 READ
Purpose
Reads data of RFID from reader/writer.
Command message
Format
Command code
PICC
identifier
No. of service file
identifiers (k)
List of service file
identifiers
No. of blocks
(m)
Block list
1 byte 8 bytes 1 byte 2×k bytes 1 byte
2×m or 3×m
bytes
Data field
Field
Setting
Remarks
Command code
0x06
PICC identifier
PICC identifier acquired by REQ command
described in Section 4.2.6.1 REQ.
No. of service file
identifiers (k)
Number of service files
Setting range: 0x01(1) to 0x0F(15)
When the range other than the
range on the left column is set,
the RFID responds with an
error.
List of service file
identifiers
Don't care (Setting example: 0x0900)
When specifying multiple
services, the RFID responds
with an error if all service files
are not set to the same value.
No. of blocks (m)
Number of blocks specified in block list
Setting range:
Plaintext (unencrypted) communication in RF
communication mode: 0x01(1) to 0x0F(15)
Other: 0x01(1) to 0x0F(15)
When the range other than the
range on the left column is set,
the RFID responds with an
error.
Block list
Block list of data to be read
For information about how to set, see the
following:
4.2.5.6
4.2.5.7
Response message
Chapter 4 RF Communication Mode
45
Format
Response code PICC identifier
Status flag 1
Status flag 2
No. of blocks
(m)
Block data
1 byte
8 bytes
1 byte
1 byte
1 byte
16×m byte
Data field
Field
Output value
Remarks
Response code
0x07
PICC identifier
See 4.2.5.2 PICC (Proximity IC Card) Identifier.
Status flag 1
See 4.2.5.8 Status Flag
Status flag 2
See 4.2.5.8 Status Flag.
No. of blocks (m)
Number of blocks specified by the command
Omitted when the status is not
"Normal end"
Block data
See 4.2.5.7 Block List.
Omitted when the status is not
"Normal end"
Chapter 4 RF Communication Mode
46
4.2.6.3 WRITE
Purpose
Writes data to RFID from reader/writer.
Command message
Format
command
code
PICC
identifier
No. of service file
identifiers (k)
List of service file
identifiers
No. of
blocks (m)
Block list Block data
1 byte 8 bytes 1 byte 2×k bytes 1 byte
2×m or 3×m
bytes
16×m bytes
Data field
Field
Setting
Remarks
Command code
0x08
PICC identifier
PICC identifier acquired by REQ command
described in Section 4.2.6.1
No. of service
file identifiers (k)
Number of service files
Setting range: 0x01(1) to 0x0B(11)
When the range other than the
range on the left column is set,
the RFID responds with an
error.
List of service
file identifiers
Don't care (Setting example: 0x0900)
When specifying multiple
services, the RFID responds
with an error if all service files
are not set to the same value.
No. of blocks
(m)
Number of blocks specified in block list
Setting range:
No. of service files is 1 to 8: 0x01(1) to 0x0C(12)
No. of service files is 9 to 11: 0x01(1) to 0x0B(11)
When the range other than the
range on the left column is set,
the RFID responds with an
error.
Block list
Block list of data to be written
For information about how to set, see the following:
4.2.5.6 Block
4.2.5.7 Block list
Block data
See 4.2.5.7 Block list
Response message
Format
Response code
PICC identifier
Status flag 1
Status flag 2
1 byte
8 bytes
1 byte
1 byte
Data field
Field
Output value
Remarks
Response code
0x09
PICC identifier
See 4.2.5.2 PICC (Proximity IC Card) Identifier.
Status flag 1
See 4.2.5.8 Status Flag.
Status flag 2
See 4.2.5.8 Status Flag.
Chapter 4 RF Communication Mode
47
4.2.7 NDEF
This RFID is based on Type3 Tag and Type4B Tag of NFC Forum and supports data exchange of a NDEF format.
This section explains Type3 Tag.
In addition, 4.3.10 NDEF explains Type4B Tag of NFC Forum.
Data exchange of NDEF can be performed by performing a predetermined setup to the user area of FeRAM.
Please refer to the applicable written standards of NFC Forum for the details of NDEF.
4.2.7.1 MEMORY MAP
The memory map at the time of NDEF use is shown in Fig. 4-13
Attribute Information Block is arranged to Block0.
NDEF file is arranged from Block1 to Block23.
0 0x0000 Attribute Information Block
1 0x0010
2 0x0020
3 0x0030
4 0x0040
5 0x0050
6 0x0060
7 0x0070
8 0x0080
9 0x0090
10 0x00A0
11 0x00B0
12 0x00C0
13 0x00D0
14 0x00E0
15 0x00F0
16 0x0100
17 0x0110
18 0x0120
19 0x0130
20 0x0140
21 0x0150
22 0x0160
23 0x0170
24 0x0180
25 0x0190
26 0x01A0
27 0x01B0
28 0x01C0
29 0x01D0 System Area
30 0x01E0
31 0x01F0
SC
    NDEF data area (message area)
When using in common by Type3 tag and Type4B Tag
When using it
only by Type3 Tag
Fig 4-13 The memory map at the time of NDEF use.NFC Forum Type3 Tag
4.2.7.2 Setup of System CodeSC
In order to use NDEF of Type3 Tag, It is necessary to set value "0x12FC." on a system code(SC)
Chapter 4 RF Communication Mode
48
4.2.7.3 Setup of Attribute Information Block
Attribute Information Block(AIB) is arranged to Block0.
Explanation and the example of a setting of Attribute Information Block (AIB) are shown in Table 4-10.
Table 4-10 The example of a setting of Attribute Information Block (AIB)
Physical
address
Size
Value
Contents
Supplement
0x0000
1Byte
0x10
Mapping Version
Please set up according to the NDEF
standard version to apply.
0x0001
1Byte
0x0F
Nbr (The number of the maximum
block of one read command)
Please set up 0x0F in this RFID.
0x0002
1Byte
0x0B
Nbw (The number of the maximum
block of one write command)
Please set up 0x0B in this RFID.
0x0003
0x0004
2Byte
0x0017
Nmaxb (The number of maximum
block of NDEF data which can
handle this RFID)
(Note:)
0x0005
0x0008
4Byte
0x00000000
Intact area
Please set 4 bytes of 0x00 to all.
0x0009
1Byte
0x00
WriteF
0x00Write-in completion
0x0FUnder a write-in advance
Please set 0x0Fbefore the writing
of a NDEF message, and Please set
0x00after all the writing of a
NDEF message completed,
0x000A
1Byte
0x01
RW-Flag
0x00AIB is read-only.
0x01Read and write are possible
for AIB.
0x000B
0x000D
3Byte
0x000003
Ln (NDEF message length)
0x000003 = 3Byte
The value to a setting example of a
setting of Table 4-11)
0x000E
0x000F
2Byte
0x0046
CheckSum
The sum of data level to address
0x0000 - 0x000D
Note: When sharing a NDEF message by Type3 Tag and Type4B Tag, the maximum of Nmaxb is 0x0017.
When using it only by Type3 Tag, the maximum of Nmaxb is 0x001A.
However, the maximum of Nmaxb may be set to 0x0018 depending on the directions for encryption
communication. Refer to the administrator manual for the details of encryption communication.
4.2.7.4 NDEF FILE
An empty NDEF file is shown in Table 4-11 as an example of a setting of a NDEF file.
Table 4-11 The example of a setting of a NDEF file (An empty NDEF file)
Chapter 4 RF Communication Mode
49
Physical
address
Size
Value
Contents
Supplement
0x0010
0x0012
3Byte
0xD00000
NDEF Message
A mentioned value is a value
which shows an empty message.
Chapter 4 RF Communication Mode
50
4.3 ISO/IEC14443 TypeB Specification
This section describes the ISO/IEC14443 TypeB specification.
4.3.1 Communication Specification
Table 4-12 provides the communication specifications of this RFID based on ISO/IEC14443 TypeB.
Table 4-12 ISO/IEC14443 TypeB Communication Specification
Carrier frequency
13.56 MHz
Modulation mode,
Bit coding
R/W→RFID
ASK10%, NRZ coding
RFID→R/W
Load modulation, BPSK coding (848 kHz subcarrier)
Data rate
106 kbps / 212 kbps
Character transmission
LSB-first
Data (8 bits)
Start bit (1 bit)
Stop bit (1 bit)
4.3.2 Frame Format
Figure 4-14 illustrates the ISO/IEC14443 TypeB frame format. SOF(Start Of Frame) and EOF(End Of Frame)
are added to a data field. The maximum size of data field is 256 bytes in this RFID.
Figure 4-14 ISO/IEC14443 TypeB Frame Format
Additionally, the ISO/IEC14443-4 block format shown in Figure 4-15 is applied to the data field shown in
Figure 4-14. This RFID does not support CID and NAD of the first field, so adding them is prohibited.
Figure 4-15 ISO/IEC14443-4 Block Format
EOFData field (maximum 256 bytes)SOF EOFData field (maximum 256 bytes)SOF
1 byte
[CID]*
1 byte
[NAD]*
2 bytes CRC0 to 253 bytes (when CID and
NAD are omitted)
1 byte
ECD
Last field
INF
Information field
PCB
First field
1 byte
[CID]*
1 byte
[NAD]*
2 bytes CRC0 to 253 bytes (when CID and
NAD are omitted)
1 byte
ECD
Last field
INF
Information field
PCB
First field
Error-detecting signal
CID and NAD: Not supported
by this RFID
(Adding CID and NAD is prohibited.)
Frame size
Chapter 4 RF Communication Mode
51
Table 4-13 ISO/IEC14443-4 Field Definition
Field name
Byte length
Definition
PCB
1
Protocol Control Byte. See 4.3.3 Protocol Control
CID 1
Card Identifier (optional) Used to identify RFID.
(Not supported by this RFID; not added.)
NAD 1
Node Address (optional). Used to establish a logical
channel.
(Not supported by this RFID; not added.)
INF
n
Command message or response message
ECD
2
See CRC_B ISO/IEC14443-3.
4.3.3 Protocol Control
PCB (Protocol Control Byte) shown in Figure 4-15 and Table 4-13 is provided for ISO/IEC14443-4 protocol
control, and used to send information necessary for data transmission control. This protocol has 3 block
types. Table 4-14 lists the definition of block type. This RFID's protocol control specification is given in Table
4-15.
Figure 4-16, Figure 4-17, and Figure 4-18 illustrate I-block, R-block, and S-block codings, respectively.
Table 4-14 Block Type
Block name
Definition
I-block
Used to send the information of application layer.
R-block
Used to send ACK (Acknowledge) or NAK (NegativeAcknowlege).
R-block does not include INF field.
An R-block corresponding to the last reception block will be sent.
S-block
Used to send a control information. The following 2 types are provided:
1. Wait time extension request (WTX)
2. DESELECT command
Table 4-15 Protocol Control Specification
Item
Description
By this RFID
CID
(Card IDentifier)
First field parameter of ISO/IEC14443-4 frame
(optional). Used to identify RFID.
Not supported
NAD
(Node Address)
First field parameter of ISO/IEC14443-4 frame
(optional). Used to establish a logical channel.
Not supported
Chaining Used to transmit/receive divided data
Supported (however, the size of
divisible frame size is 64 bytes or
more.)
ACK/NCK
response
Used to send ACK (Acknowledge) or NAK
(NegativeAcknowlege).
Supported
WTX
Used to extend the wait time for response from
RFID
Not supported
DESELECT
command
Used to deselect the RFID. Supported
b8 b7
b6 b5 b4 b3 b2 b1
0 0 0 0 0 1
b8 b7
b6 b5 b4 b3 b2 b1
0 0 0 0 0 1
Block number
Set to 1. (0: No response)
NAD enable/disable. Set to 0 (NAD disable). (1: No response)
CID enable/disable. Set to 0 (CID disable). (1: No response)
Setting to 1 enables chaining.
Set to 0. (1: No response)
Chapter 4 RF Communication Mode
52
Figure 4-16 I-block Coding
Figure 4-17 R-block Coding
Figure 4-18 S-block Coding
4.3.4 Block Control
The block number rule for ISO/IEC14443-4 I-block is given in Table 4-16. The block control rule and whether
to be supported by this RFID are shown in Table 4-17.
Table 4-16 Block Number Rule
Applied to
No.
Rule
Reader/
Writer
RuleA
Set the initial value of reader/writer block number to 0 whenever activating RFID.
RuleB
When I-block or R(ACK) block whose block number is equal to the current one is
received, toggle the current block number before sending the block number to
RFID.
RFID
RuleC
Set the initial value of RFID block number to 1 whenever activating RFID.
RuleD
When I-block is received, toggle the current block number before sending the
block.
RuleE
When R(ACK) block whose block number is not equal to the current one is
received, RFID toggles the current block number before sending the block.
When
R(NAK) is received, do not toggle the block number.
Table 4-17 Block Control Rule
b8 b7 b6 b5 b4 b3 b2 b1
1 0 1 0 0 1
b8 b7 b6 b5 b4 b3 b2 b1
1 0 1 0 0 1
Block number
Set to 1. (0: No response)
Set to 0. (1: No response)
CID enable/disable. Set to 0 (CID disable).
0: ACK; 1: NACK
Set to 1. (0: No response)
R-Block
b8 b7 b6 b5 b4 b3 b2 b1
11 0010
b8 b7 b6 b5 b4 b3 b2 b1
11 0010
Set to 0. (1: No response)
Set to 1. (0: No response)
Set to 0. (1: No response)
CID enable/disable. Set to 0 (CID disable).
(00)b, DESELECT
(No response, except (00)b)
S-Block
Chapter 4 RF Communication Mode
53
Applied to
No. Rule By this RFID
Reader/
Writer and
RFID
Rule1
Send the first block from reader/writer.
Supported
Rule2
When I-block indicating chaining is received, send an affirmative
response to the block, with R(ACK) block.
Supported
Rule3 S-block is used only for pair. Send a response to S(...)block
whenever S(...)block is requested.
Only
DESELECT
supported
Reader/
Writer
Rule4
When an illegal block is received or FWT timeout occurs, send
R(NAK) block (except while RFID is in chaining or when
S(DESELECT) is executed).
-
Rule5
When an illegal block is received or FWT timeout occurs while
RFID is in chaining, send R(ACK) block.
-
Rule6
When R(ACK) block is received and its block number is not equal
to the block number of reader/writer, re-send the last I-block.
-
Rule7
When R(ACK) block is received and its block number is equal to
the block number of reader/writer, continue chaining.
-
Rule8
When a response to S(DESELECT) is not sent with no error,
re-send S(DESELECT) or ignore the RFID.
-
RFID
Rule9 RFID can send S(WTX) block, instead of I-block or R(ACK) block.
Not
supported
Rule10
When I-block not indicating chaining is not received, send an
affirmative response.
Supported
Rule11
When R(ACK) or R(NAK) block is received and its block number
is equal to the block number of RFID, re-send the last I-block.
Supported
Rule12
When R(NAK) block is received and its block number is not equal
to the block number of RFID, send R(ACK).
Supported
Rule13
When R(ACK) block is received and its block number is not equal
to the block number of RFID and RFID is in chaining, continue
chaining.
Supported
4.3.5 Upper Command Format
The upper commands (SELECT, READ, WRITE) are compliant with the APDU (Application Protocol Data
Unit) format of ISO/IEC7816-4.
Figure 4-19 shows the command APDU format. Table 4-18 shows the command APDU field definition. Figure
4-20 gives the response APDU format. Table 4-19 gives the response APDU field definition.
The command APDU format shown in Figure 4-19 and the response APDU format shown in Figure 4-20 are
configured in the information field INF of the ISO/IEC14443-4 block format shown in Figure 4-15.
Figure 4-19 Command APDU Format
Table 4-18 Command APDU Field Definition
Field name
Byte length
Definition
Class byte
1
Fixed to 0x00
Le
field
Le
Data byte
(Lc bytes)
Data
Param
byte
P2
Param
byte
P1
Instruction
byte
INS
Lc fieldClass
byte
LcCLA
Le
field
Le
Data byte
(Lc bytes)
Data
Param
byte
P2
Param
byte
P1
Instruction
byte
INS
Lc fieldClass
byte
LcCLA
Chapter 4 RF Communication Mode
54
Instruction byte
1
Instruction code
Param byte 1
1
Command parameter
Param byte 2
1
Command parameter
Lc field 1
If a data byte exists in the command APDU, set the
byte length of n; if not, omit the data byte.
Data byte
n
Data block (can be omitted)
Le field 1
If a data byte exists in the response APDU, set the
byte length; if not, omit the data byte.
Figure 4-20 Response APDU Format
Table 4-19 Response APDU Field Definition
Field name
Byte length
Definition
Data byte
n
Data block (can be omitted)
Status word 1
1
Status information
Status word 2
1
Status information
Status
word 2
SW2
Status
word 1
SW1
Data byte
Response Body
Status
word 2
SW2
Status
word 1
SW1
Data byte
Response Body
Chapter 4 RF Communication Mode
55
4.3.6 State Transition Diagram
Figure 4-21 provides the state transition diagram for this RFID's operation based on ISO/IEC14443 TypeB.
POWER_OFF
IDLE
READY
HALTPROTOCOL
Magnet field ON/ No response
REQB(AFI)/ ATQB
WUPB(AFI)/ ATQB
REQB(nAFI)/ No response
WUPB(nAFI)/ No response
HLTB(PUPI)/ No response
HLTB(nPUPI)/ No response
ATTRIB(PUPI)/ No response
ATTRIB(nPUPI)/ No response
Other commands/ No response
CRC error/ No response
REQB(nAFI)/ No response
WUPB(nAFI)/ No response
Notes
Even in any of IDLE, READY, PROTOCOL, or HALT
state, turning RF off causes the RFID to transition to
POWER_OFF state.
AFI: AFI matchednAFI: AFI unmatched
PUPI: PUPI matchednPUPI: PUPI unmatched
ATTRIB(PUPI)/ Response HALT(PUPI)/ Response
DESELECT/
Response
WUPB(AFI)/ATQB
SELECT/ Response
READ/ Response
WRITE/ Response
WUPB(nAFI)/ No response
CLA error/ Response with an error
INS error/ Response with an error
P1, P2 error/ Response with an error
Lc, Le error/ Response with an error
Self-diagnosis error/ Response with an error
REQB(AFI)/ATQB
WUPB(AFI)/ATQB
HLTB(nPUPI)/ No response
ATTRIB(nPUPI)/ No response
Other commands/ No response
CRC error/ No response
REQB(AFI)/ No response
REQB(nAFI)/ No response
WUPB(AFI)/ No response
WUPB(nAFI)/ No response
HLTB(PUPI)/ No response
HLTB(nPUPI)/ No response
ATTRIB(PUPI)/ No response
ATTRIB(nPUPI)/ No response
CRC error/ No response
PCB setting error/ No response
REQB(AFI)/ No response
REQB(nAFI)/ No response
HLTB(PUPI)/ No response
HLTB(nPUPI)/ No response
ATTRIB(PUPI)/ No response
ATTRIB(nPUPI)/ No response
Other commands/ No response
CRC error/ No response
Magnet field OFF
Figure 4-21 State Transition Diagram for Operation Based on ISO/IEC14443 TypeB
Chapter 4 RF Communication Mode
56
4.3.7 Flow Chart
Figure 4-22 illustrates the flow chart for this RFID's command processing based on ISO/IEC14443 TypeB.
Figure 4-22 Flow Chart of Command Processing Based on ISO/IEC14443 TypeB
PUPI identified?
Respond to ATTRIB. Respond to HLTB.
Yes
ATTRIB HLTB
Magnet field ON
Respond to ATQB
REQB/WUPB
Other
Yes
Yes
No
PUPI identified?
No Yes
No
PROTOCOL state
Respond to command.
SELECT
READ
WRITE
DESELECT
Respond to DESELECT.
HALT state
READY state
IDLE state
WUPB Other
Any of the following conditions identified?
AFI is 0x00.
AFI is 0xY0 and Y of upper 4 bits are matched.
AFI is 0x0Y and Y of lower 4 bits are matched.
AFI1 byte is matched.
REQB/WUPB
Other
PUPI identified?
Respond to ATTRIB. Respond to HLTB.
Yes
ATTRIB HLTB
Magnet field ON
Respond to ATQB
REQB/WUPB
Other
Yes
Yes
No
PUPI identified?
No Yes
No
PROTOCOL state
Respond to command.
SELECT
READ
WRITE
DESELECT
Respond to DESELECT.
HALT state
READY state
IDLE state
WUPB Other
Any of the following conditions identified?
AFI is 0x00.
AFI is 0xY0 and Y of upper 4 bits are matched.
AFI is 0x0Y and Y of lower 4 bits are matched.
AFI1 byte is matched.
REQB/WUPB
Other
Chapter 4 RF Communication Mode
57
4.3.8 Various Settings
This section describes the parameter settings and operation specifications based on ISO/IEC14443 TypeB for
this RFID.
4.3.8.1 AFI (Application Family Identifier)
Figure 4-23 shows the format of AFI (Application Family Identifier). The value of AFI is set in the system area
AFI.
AFI is a parameter specified by the REQB command. The response operation to REQB command in this
RFID is shown in Table 4-20. For information about the setting values for AFI, see ISO/IEC14443-3.
AFI
D0
AFI
D0
AFI
Figure 4-23 AFI Format
Table 4-20 REQB Command Response Operation
REQB command
AFI setting value
RFID's response to REQB command
0x00
Responds regardless of the system area AFI setting.
0xY0
Responds when the value Y of the upper 4 bits of the
REQB command's AFI is matched.
0x0Y
Responds when the value Y of the lower 4 bits of the
REQB command's AFI is matched.
Other
Responds only when the setting value of the REQB
command's AFI matches the value specified in the system
area AFI.
4.3.8.2 PUPI (Pseudo-Unique PICC Identifier)
Figure 4-24 shows the format of PUPI (Pseudo-Unique PICC Identifier). PUPI is an identifier of PICC
(Proximity IC Card). The value of PUPI is set in the lower 4 bytes of the system area IDM.
Figure 4-24 PUPI Format
Lower 4 bytes of IDM
D3D2D1D0
Lower 4 bytes of IDM
D3D2D1D0
PUPI
Chapter 4 RF Communication Mode
58
4.3.8.3 FWI (Frame Waiting Time Integer)
Figure 4-25 shows the format of FWI (Frame Waiting time Integer). FWI is used to specify the maximum wait
time until the PICC sends a response after receiving a command.
Figure 4-25 FWI Format
The maximum wait time is calculated by the following formula:
Maximum wait time = T × 2FWI
T: 256 × 16/fc (fc = 13.56 MHz, approx. 0.302 ms)
FWI: 0 to 14 (integer)
The maximum wait time ranges from approximately 0.302 ms (min.; FWI = 0) to approximately 4949 ms (max;
FWI = 14).
4.3.8.4 File System
This RFID is compliant with the command specification of ISO/IEC7816-4 standards, but does not implement
the file system functionality of the standards. However, in order to ensure the compatibility with
communication to reader/writer, the SELECT command to select files is set to "Normal response" when
specifying the given parameters. For information about how to set the parameters of the SELECT command,
see 4.3.9.4 SELECT.
Chapter 4 RF Communication Mode
59
4.3.8.5 Address
In ISO/IEC14443 TypeB (command is compliant with ISO/IEC7816-4), the addresses of READ and WRITE
commands are specified by bytes P1 and P2 of the command APDU. (See Section 4.3.5 Upper Command
Format)
Figure 4-26 shows the address specification format. Set bit 7 of byte P1 to 0; setting to 1 causes an error.
Figure 4-26 Address Specification
This RFID uses address to specify encrypted communication. Table 4-21 shows mode settings including
encrypted communication with bits 6 to 4 of byte P1.
Table 4-21 Mode Settings
Byte P1
Meaning
Bit 6 Bit 5 Bit 4
Communication
mode
Encrypted communication
- - -
RF communication
mode
Plaintext (unencrypted)
communication
0
0
0
0 1 0
Encrypted communication
(private key)
0 1 1
Encrypted communication
(family key)
0
0
1
Reserved (Setting this field causes an error.)
1
0
0
1
1
0
1
1
1
1
0
1
Reserved (Setting this field causes an error.)
In addition, Table 4-22 shows the setting unit for address by communication mode.
Table 4-22 Setting Unit for Address
Communication mode
Setting unit for address
(n: integer)
Plaintext (unencrypted)
1×n bytes
Encrypted
16×n bytes
Note: Setting the address to a value other than 16×n bytes in encrypted communication causes the RFID to
respond with an error.
4.3.8.6 Data
For encrypted communication, the structure of data block for READ and WRITE commands is slightly different
Start address designationMode setting
Start address
0
This RFID’s
setting value
-Definition
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Start address designationMode setting
Start address
0
This RFID’s
setting value
-Definition
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
msb lsb msb lsb
P1 P2
Chapter 4 RF Communication Mode
60
from the ISO/IEC7816-4 command specification. Figure 4-27 shows the data block structure.
(1) Plaintext (unencrypted) communication treats all block data as actual data.
(2) In encrypted communication, the first 16 bytes of data is IV (Initial Vector) used for encryption, following
16×n bytes of data is actual data, and the last 16 bytes is MAC value for Message Authentication Code
(MAC).
Figure 4-27 Data Block Structure
Note: Setting the data length to a value other than 16×n bytes in encrypted communication causes the RFID
to respond with an error.
(1) Plaintext
(unencrypted)
communication
(2) Encrypted
communication
1 x n bytes (n: integer)
DATA
1 x n bytes (n: integer)
DATA
Actual data
MAC value
Actual data
16 x n bytes (n: integer) 16 bytes16 bytes
DATA
16 x n bytes (n: integer) 16 bytes16 bytes
DATA
IV
Size specified by the Lc or Le field
Size specified by the Lc or Le field
Chapter 4 RF Communication Mode
61
4.3.8.7 Status Word
Table 4-23 lists the meaning of statuses.
Table 4-23 Status Word
SW1
SW2
Meaning
Description
0x90
0x00
Normal end
Terminated normally.
0x50
0x00
unmounted mode
mode is un-mounting.
0x51
0x00
unmounted mode
mode is un-mounting.
0x67
0x00
Lc/Le specification error
(*1)
Lc and Le were out of the specification.
In encrypted communication, Lc and Le were not
16×n bytes.
0x6A
0x86
P1-P2 specification error
Bit 7 of P1 was not 0. (*2)
Illegal mode setting (RFU setting)
Specified outside FeRAM
In encrypted communication, the address was not
specified in 16×n byte units.
0x6D
0x00
INS specification error
Illegal INS setting (Specified an unimplemented
command)
0x6E
0x00
CLA specification error
Illegal CLA setting (except 0x00)
0x6F
0x00
Self-diagnosis error
(*1)
Write access to FeRAM-Read-Only area
Plaintext (unencrypted) command access to
Encrypted-communication-enable-only area
(*1) For more information about these errors, see the Administrator's Manual.
(*2) In the case of SELECT command, it may become "Lc, Le error 0x6700" depending on the combination of
values of P1,P2.
Chapter 4 RF Communication Mode
62
4.3.9 Command
The commands based on ISO/IEC14443 TypeB supported by this RFID fall into two types:
Commands defined in ISO/IEC14443-3, and APDU commands defined in ISO/IEC7816-4 to be sent in the
ISO/IEC14443-4 format.
These commands are shown in Table 4-24 and Table 4-25.
For information about the command format, see Section 4.3.2 Frame Format and Section 4.3.5 Upper
Command Format.
Additionally, protocol control such as chaining, ACK/NAK response (R-Block), and DESELECT (S-Block) are
also supported. For its detail, see Section 4.3.3 Protocol Control.
Subsequent sections describe each command in detail.
Table 4-24 ISO/IEC14443-3 TypeB Command List
Name
Code
Description
REQB/WUPB
0x05
Identifies the RFID. Used by reader/writer.
ATTRIB
0x1D
Exchanges protocol signal information between reader/writer and
RFID, and causes the RFID to transition to the state in which
command processing is enabled.
HLTB
0x50
Transitions the RFID to a HALT state. Used by reader/writer.
Table 4-25 APDU Command List
Name
INS
Description
SELECT
0xA4
Selects the file. (No processing is performed in this RFID.
READ
0xB0
Reads the data of RFID from reader/writer.
WRITE
0xD6
Writes a data to RFID from reader/writer.
Chapter 4 RF Communication Mode
63
4.3.9.1 REQB/WUPB
Purpose
Identifies the RFID. Used by reader/writer
REQB is used when the RFID is in IDLE state.
WUPB is used when the RFID is in HALT state. (It can be also used in IDLE state.)
Command message
Format
Command code
AFI
PARAM
CRC_B
1 byte
1 byte
1 byte
2 bytes
Data field
Field
Setting
Remarks
Command code
0x05
AFI
0x00: Identifies all RFIDs.
0xY0: RFID whose upper 4 bits are identified
responds.
0x0Y: RFID whose lower 4 bits are identified
responds.
Other than 0x00: RFID corresponding to the
specified system code responds.
See 4.3.8.1 AFI (Application
Family Identifier).
PARAM
0x00: REQB
0x08: WUPB
This RFID always operates as
follows:
Ignores the setting of bits
7-5.
Recognizes the number N of
Slots is 1 (always responds
with ATQB) even when bits
2-0 are set to any of the
values (including PFU).
Bits 7-5
RFU (Set to 000b.)
Bit 4
0: Extension ATQB not supported
1: Extension ATQB supported
Bit 3
0: REQB
1: WUPB
Bits 2-0
000b: Slot count N = 1
001b: Slot count N = 2
010b: Slot count N = 4
011b: Slot count N = 8
100b: Slot count N = 16
101b: RFU
110b: RFU
CRC_B
See CRC_B ISO/IEC14443-3.
Chapter 4 RF Communication Mode
64
Response message
Format
Response code
PUPI
Application data
Protocol info
CRC_B
1 byte
4 bytes
4 bytes
3 bytes
2 bytes
Data field
Field
Output value
Remarks
response code
0x50 (ATQB)
PUPI
See 4.2.5.2 PICC (Proximity IC Card) Identifier.
Application Data
0x00000000
Reserved (treated as
proprietary data.)
Protocol Info
1st byte: 0x91
For more information about
parameters, see
ISO/IEC14443-3.
Bits 7-0
Data rate setting: 0x91
R/W→RFID: 106K, 212K bps
RFID→R/W: 106K, 212K bps
R/W→RFID, RFID→R/W (same data
rate)
2nd byte: 0x81
Bits 7-4
Maximum frame size of RFID
1000b: 256 bytes
Bits 3-0
Protocol type: 0001b
RFID is ISO/IEC14443-4 compliant
Minimum reader/writer command
wait time (TR2) after RFID responds:
10etu + 32/fs (fs = 848 kHz)
3rd byte: 0xX0 (X is a value of FWI.)
Bits 7-4
FWI (Frame Waiting time Integer)
See 4.3.8.3 FWI (Frame Waiting
Time Integer).
Bits 3-2
ADC (Application Data Coding)
00b: Proprietary Application Data
Bits 1-0
FO (Frame Option)
00b: NAD, CID not supported
CRC_B
See CRC_B ISO/IEC14443-3.
Chapter 4 RF Communication Mode
65
4.3.9.2 ATTRIB
Purpose
Exchanges protocol signal information between reader/writer and RFID, and causes the RFID to transition to
the state in which command processing is enabled.
Command message
Format
Command code
Identifier
Param1
Param2
Param3
Param4
CRC_B
1 byte
4 bytes
1 byte
1 byte
1 byte
1 byte
2 bytes
Data field
Field
Setting
Remarks
Command code
0x1D
Identifier
Sets PUPI for ATQB response.
Param1
0x00
This RFID operates with:
bits 1-0 ignored
bits 7-6 set to 00b (when
these bits are set to 11b)
bits 5-4 set to 00b (when
these bits are set to 11b)
This RFID operates with:
Minimum TR0: 64/fs
Minimum TR1: 80/fs
EOF not omitted
SOF not omitted
Bits 7-6
Minimum value of RFID response time
to reader/writer command (TR0): (fs =
848 kHz)
00b: 64/fs (106 Kbps), 64/fs (212
Kbps)
01b: 48/fs (106 Kbps), 32/fs (212
Kbps)
10b: 16/fs (106 Kbps), 8/fs (212 Kbps)
11b: RFU
Bits 5-4
Minimum value of the time (TR1) until
RFID starts data transmission after
subcarrier is generated:
(fs = 848 kHz)
00b: 80/fs (106 Kbps), 80/fs (212
Kbps)
01b: 64/fs (106 Kbps), 32/fs (212
Kbps)
10b: 16/fs (106 Kbps), 8/fs (212K bps)
11b: RFU
Bit 3
0: Do not omit EOF.
1: Omit EOF.
Bit 2
0: Do not omit SOF.
1: Omit SOF.
Bits 1-0
RFU (Set to 00b.)
Param2
0xXX (For XX, see the settings below.)
If parameters other than
those on the left
(communication settings or
reader/writer frame size
which the RFID does not
support) are set, the RFID
will generate no response.
If the data rate setting differs
between RFID→PCD and
PCD→RFID, the RFID will
generate no response.
Bits 7-6
RFID→PCD data rate
00b: 106 Kbps
01b: 212 Kbps
Bits 5-4
PCD→PICC data rate
00b: 106 Kbps
01b: 212 Kbps
Bits 3-0
Maximum receptible frame size of
reader/writer
1000b: 256 bytes
Chapter 4 RF Communication Mode
66
0111b: 128 bytes
0110b: 96 bytes
0101b: 64 bytes
Param3
0x01
If parameters other than those
on the left are set, the RFID
will generate no response.
Bits 7-4
RFU (Set to 0000b.)
Bits 3-0
Set to the same value as that for the
protocol type (4 bits) of the ATQB
parameter's second byte.
Param4
0x00
The RFID operates with:
bits 7-4 ignored
no response generated
except when bits 3-0 are set
to 0000b
Bits 7-4
RFU (Set to 0000b.)
Bits 3-0
0000b: RFID does not support CID.
CRC_B
See CRC_B ISO/IEC14443-3.
Response message
Format
Response code
CRC_B
1 byte
2 bytes
Data field
Field
Output value
Remarks
response code
1st byte: 0x10
For more information about
parameters, see
ISO/IEC14443-3.
Bits 7-4
MBLI (Maximum Buffer Length
Integer)
0001b: 1x of RFID frame size (256
bytes)
Bits 3-0
0000b: RFID does not support CID.
CRC_B
See CRC_B ISO/IEC14443-3.
Chapter 4 RF Communication Mode
67
4.3.9.3 HLTB
Purpose
Causes the RFID to transition to a HALT state. Used by reader/writer.
Command message
Format
Command code
Identifier
CRC_B
1 byte
4 bytes
2 bytes
Data field
Field
Setting
Remarks
Command code
0x50
Identifier
Sets the PUPI of the RFID to be set to a HALT
state.
CRC_B
See CRC_B ISO/IEC14443-3.
Response message
Format
Response code
CRC_B
1 byte
2 bytes
Data field
Field
Output value
Remarks
Response code
0x00
CRC_B
See CRC_B ISO/IEC14443-3.
Chapter 4 RF Communication Mode
68
4.3.9.4 SELECT
Purpose
Selects the file.
This RFID conforms to the NDEF Ver. 2.0 of NFC forum Type 4B tag and therefore is capable of performing
the following selections: EF file, NDEF application, CC file, or NDEF file.
For operations at CC or NDEF file selections, see Section 4.3.10.3 CC File and Section 4.3.10.4 NDEF
File.
Command message
Format
CLA
INS
P1
P2
Lc
Data
Le
1 byte 1 byte 1 byte 1 byte 1 byte n bytes
1 byte
Data field
Field
Setting
Remarks
CLA
0x00
Responds with an error, except
0x00.
INS
0xA4
P1
0x00: Selection by a file identifier
0x02: EF file selection
0x04: Selection by DF name (Selection by an
application identifier)
A combination except follows is
an error reply
P1,P2=0x020CEF file choice
P1,P2=0x0400NDEF tag
application choice
P1,P2=0x000CEF file, CC file
or NDEF file choice
P2
0x00: Designate the corresponding file.
0x0C: FCI generates no response.
Lc
Sets the byte length of the Data block.
Setting range:
NDEF tag application selection (when P1, P2 =
x0400):
0x07(7)
Other than the above: 0x02(2)
Responds with an error, except
the setting range on the left
column.
Data
NDEF tag application selection (when P1, P2 =
x0400): 0xD2760000850101
CC file selection (when P1, P2 = 000C): 0xE103
NDEF file selection (when P1, P2 = 000C): 0x0103
EF file selection (when P1, P2 = 020C): Don't care
(This field is set by EF-ID.)
Responds with an error, except
the settings on the left column.
Le
Sets the byte length of the Data block for response.
Setting range: 0x00 (with field only for NDEF tag
application selection)
Responds with an error, except
the setting range on the left
column.
Setting examples
Chapter 4 RF Communication Mode
69
EF file selection
CLA
INS
P1
P2
Lc
Data
0x00
0xA4
0x02
0x0C
0x02
0xXXXX
In case of the P1,P2=x020C setting, any value of Data(EF-ID) is settable.
CLA
INS
P1
P2
Lc
Data
0x00
0xA4
0x02
0x0C
0x02
0xXXXX
In case of the P1,P2=0x000C setting, please set Data(EF-ID) any place other than 0xE103 and 0x0103.
NDEF tag application selection
CLA
INS
P1
P2
Lc
Data
Le
0x00
0xA4
0x04
0x00
0x07
0xD2760000850101
0x00
In case of the NDEF tag application choice, only the value mentioned above is settable.
CC file selection
CLA
INS
P1
P2
Lc
Data
0x00
0xA4
0x00
0x0C
0x02
0xE103
In case of the CC file application choice, only the value mentioned above is settable.
NDEF file selection
CLA
INS
P1
P2
Lc
Data
0x00
0xA4
0x00
0x0C
0x02
0x0103
In case of the NDEF file application choice, only the value mentioned above is settable.
ID(File ID) of the NDEF file in this RFID is 0x0103 fixation.
Response message
Format
SW1
SW2
1 byte
1 byte
Data field
Field
Output value
Remarks
SW1
See 4.3.8.7 Status Word.
SW2
See 4.3.8.7 Status Word.
Chapter 4 RF Communication Mode
70
4.3.9.5 READ
Purpose
Reads the data of RFID from reader/writer.
Command message
Format
CLA
INS
P1
P2
Le
1 byte
1 byte
1 byte
1 byte
1 byte
Data field
Field
Setting
Remarks
CLA
0x00
Responds with an error,
except 0x00.
INS
0xB0
P1
Sets the start address to be read.
See 4.3.8.5 Address.
P2
Sets the start address to be read.
See 4.3.8.5 Address
Le
Sets the byte length of data to be read.
Setting range: 0x01(1) to 0xFB(251)
Sets to 16×n (n: integer) for encrypted
communication.
Maximum value of n is 15 for
encrypted communication.
Response message
Format
Data
SW1
SW2
1 to 251 bytes
1 byte
1 byte
Data field
Field
Output value
Remarks
Data
Sets the data to be read.
See 4.3.8.6 Data.
Omitted except when status
word ends normally.
SW1
See 4.3.8.7 Status Word.
SW2
See 4.3.8.7 Status Word.
Chapter 4 RF Communication Mode
71
4.3.9.6 WRITE
Purpose
Writes a data to RFID from reader/writer.
Command message
Format
CLA
INS
P1
P2
Lc
Data
1 byte
1 byte
1 byte
1 byte
1 byte
1 to 248 bytes
Data field
Field
Setting
Remarks
CLA
0x00
Responds with an error,
except 0x00.
INS
0xD6
P1
Sets the start address of data to be written.
See 4.3.8.5 Address
P2
Sets the start address of data to be written.
See 4.3.8.5 Address
Lc
Sets the byte length of the Data block.
Setting range: 0x01(1) to 0xF8(248)
Sets to 16×n (n: integer) for encrypted
communication.
Maximum value of n is 15 for
encrypted communication.
Data
Sets the data to be written.
See 4.3.8.6 Data.
Response message
Format
SW1
SW2
1 byte
1 byte
Data field
Field
Output value
Remarks
SW1
See 4.3.8.7 Status Word.
SW2
See 4.3.8.7 Status Word.
Chapter 4 RF Communication Mode
72
4.3.10 NDEF
This RFID is based on Type3 Tag and Type4B Tag of NFC Forum and supports data exchange of a NDEF format
This section explains Type4B Tag.
In addition, 4.2.7 NDEF explains Type3 Tag of NFC Forum.
Data exchange of NDEF can be performed by performing a predetermined setup to the user area of FeRAM.
Please refer to the applicable written standards of NFC Forum for the details of NDEF.
4.3.10.1 Memory Map
Fig 4-28 shows the memory map in NDEF format.
CC file is assigned to Block 24.
NDEF file is assigned to part of Block 0, and Blocks 1 to 23.
Block Address 0x0 0x1 0x2 0x3 0x4 0x5 0x6 0x7 0x8 0x9 0xA 0xB 0xC 0xD 0xE 0xF
00x0000
10x0010
20x0020
30x0030
40x0040
50x0050
60x0060
70x0070
80x0080
90x0090
10 0x00A0
11 0x00B0
12 0x00C0
13 0x00D0
14 0x00E0
15 0x00F0
16 0x0100
17 0x0110
18 0x0120
19 0x0130
20 0x0140
21 0x0150
22 0x0160
23 0x0170
24 0x0180
25 0x0190
26 0x01A0
27 0x01B0
28 0x01C0
29 0x01D0
30 0x01E0
31 0x01F0
System Area
NDEF Data Area (Message)
CC File Area
User Area
User Area
Fig 4-28 Memory map when NDEF is used
Chapter 4 RF Communication Mode
73
4.3.10.2 NDEF Tag Application Selection
This selection requires a SELECT command.
4.3.10.3 CC File
This selection requires a SELECT command.
While in CC file selection, CC file starts from the beginning of Block 24 (physical address 0x0180).
See Table 4-26 shows a setting example of the CC file.
Table 4-26 Example of the CC file
Select
address
Physical
address
Size
Value
Contents
Remarks
0x0000
0x0001
0x0180
0x0181
2Byte
0x000F
CCLEN
(Length of CC file)
0x0002
0x0182
1Byte
0x20
Mapping Version
Please set 0x20 in this
RFID.
0x0003
0x0004
0x0183
0x0184
2Byte
0x003B
MLe (The biggest
response length of the
Read command
0x0005
0x0006
0x0185
0x0186
2Byte
0x0034
Mlc (The biggest
response length of the
Write command
0x0007
0x0187
1Byte
0x04
T field of the
NDEF File Control TLV
0x0008
0x0188
1Byte
0x06
L field of the
NDEF File Control TLV
0x0009
0x000A
0x0189
0x018A
6Byte
0x0103
V field of the
NDEF File Control TLV
File ID
Please set 0x 0103 in this
RFID.
0x000B
0x000C
0x018B
0x018C
0x0032
The biggest NDEF size
0x000D
0x018D
0x00
Read access condition
0x000E
0x018E
0x00
Write access condition
4.3.10.4 NDEF File
This selection requires a SELECT command.
Chapter 4 RF Communication Mode
74
Table 4-27 shows empty NDEF file as a setting example of the NDEF file.
Table 4-27 Setting example of the NDEF file(when NDEF file is empty)
Select
address
Physical
address
Size
Value
Contents
Remarks
0x0000
0x0001
0x000C
0x000D
2Byte
0x0003
NLEN (NDEF
message length)
The size of NLEN is 2Byte
fixation.
0x0002
0x0004
0x0010
0x0012
3Byte
0xD00000
NDEF message
The value shows an empty
message
The access to the NDEF file in the NDEF file choice state, I link NLEN and NDEF message and, only other
than only NLEN or NDEF message, can access it by 1 command.
In the NDEF file choice state, physical address 0x000C of Block0 the NDEF file top, the top (physical address
0x0010) becomes address 0x0002 of the NDEF file.) of Block1. In other words, the NLEN field of the NDEF
file is placed in 0x000C 0x000D of the physical address, and the NDEF message field is placed by 0x0010
of the physical address.
Chapter 5 Interrupt Generation Function
75
Chapter 5
Interrupt Generation Function
5
Chapter 5 Interrupt Generation Function
76
5.1 Interrupt Source
This RFID provides an NIRQ pin for interrupt output.
Interrupt sources are described below.
RF communication detect interrupt
An IRQ that is caused by RF communication and issued either when RF response transmission is
completed or when a write to FeRAM with the RF command is completed.
The system area HW2 parameters IRQSEL selects whether interrupt is generated and the interrupt
source. Bit 2 selects whether interrupt is generated and bit 1 selects the interrupt source.
In addition, even when interrupt generation is enabled, the WREG command for serial command can mask
the IRQ.
Magnetic-field detect interrupt
An IRQ that is caused by RF magnetic-field detection and issued when an RF magnetic field by
reader/writer is detected.
Bit 0 of the system area HW2 parameters IRQSEL selects whether interrupt is generated.
In addition, even when interrupt generation is enabled, the WREG command for serial command can mask
the IRQ.
While the contact power supply VDDEX is not applied, an IRQ is issued by starting a power supply due to
RF magnetic field. However, when RF magnetic field disappears, power supply will be stopped and low
output of the NIRQ pin will be stopped.
Chapter 6 Electrical characteristics
77
Chapter 6
Electrical characteristics
6
Chapter 6 Electrical characteristics
78
Attention
The technical information described in this document is intended only to show the main characteristics and
application circuit examples of the product. No license is granted in and to any intellectual property right or
other right owned by Panasonic Corporation or any other company. Therefore, no responsibility is assumed by
our company as to the infringement upon any such right owned by any other company which may arise as a
result of the use of technical information described in this document.
Use caution regarding the orientation of the LSI during use. Mounting of the LSI in an incorrect orientation
may cause smoke or fire.
Chapter 6 Electrical characteristics
79
Structure
CMOS Type LSI with 4Kbit FeRAM
Application
Digital AV devices, Home Appliances, Portable devices, etc.
Function
Dual interface RFID
A. Absolute Maximum Ratings Note 1)
VSS = 0 V
Item
Symbol
Rating
Unit
A1
Power supply Note 2)
V
DDA
- 0.3
+ 4.6
V
A2
Voltage antenna terminals swing (VB
Peak to peak) Note3) VCBA 30 V
A3 Output current IO 12 mA
A4
Storage temperature
T
stg
-40
85
°C
A5
Operating ambient temperature
T
opr
-20
85
°C
Note 1) Absolute Maximum Ratings are limit values not to destroy the chip and are not to
guarantee operation.
Note 2) VDDA is generated internally and are not supplied externally.
Note 3) Definition of Voltage antenna terminals swing (VCBA)
VCBA
( VB Peak to Peak )
VB
VCBA
( VB Peak to Peak )
VB
Chapter 6 Electrical characteristics
80
Notation for usage
Connect a 0.1µF2.2µF smooth capacitor between VDDA and VSS pins as close as possible to the IC.
The accuracy of the capacitor including capacitance change with temperature must be within ±30%.
Chapter 6 Electrical characteristics
81
B. Operating Conditions
Reference Ta = -20 °C 85 °C, VSS = 0 V
Item Symbol Conditions
Limits
Unit
Min
Typ
Max
B1
VDDA voltage
V
DDA
1.65
1.8
3.6
V
Chapter 6 Electrical characteristics
82
C. Electric Characteristics
Reference Ta = -20 °C 85 °C, VSS = 0 V
Item Symbol
Conditions
Limits
Unit
Min
Typ
Max
C1 Operating current on
VDDA IDDA
V
DDA
= 1.8 V
With 13.56 MHz RF input
between VA and VB
- 220 400 µA
Note5) C2is the reference specification which is used at LSI manufacturing process to
test RF communication characteristics.
I/O Pin Characteristics Ta = -20 °C 85 °C, VSS = 0 V
Item Symbol
Conditions
Limits
Unit
Min
Typ
Max
Output Pin : NIRQ
C2
Output leakage
current ILK1
10 0.02 10 µA
C3
Output voltage (Low)
V
OL1
I
OL
= 4.0mA
0.4
V
Reference Information
In our evaluation, 3.3-k (reference value) pullup resistors are connected to the open-drain pin NIRQ.
Determine the value of pullup resistors based on data rate, load capacitance, and other factors.
Chapter 6 Electrical characteristics
83
Input capacitance VSS = 0 V
Item Symbol
Condition
Limits
Unit
Min
Typ
Max
C4
Capacitance between
antenna terminals
(VA-VB)
CI
Ta=25 °C
13.56 MHz, amplitude
1V(RMS) with bias of 2V
13.5 15.5 17.5 pF
Load switch Ta = -20 °C 85 °C, VSS = 0 V
Item Symbol
Condition
Limits
Unit
Min
Typ
Max
C5
Load switch
resistance RLD
VA-VB
90 150 210 Ω
Chapter 6 Electrical characteristics
84
D. AC characteristics
RF interface Ta = -20 °C 85 °C, VSS = 0 V
Item Symbol Condition
Limits
Unit
Min
Typ
Max
D1
VB voltage (peak to
peak) at RF High
period
VRFH1
RF 13.56 MHz
4.5 - 21 V
D2 Modulation index of
command m
JISX6319-4 RF
interface specification
Communication rate of
212kbps
4.0 - 14 %
Fig.1
ba
RF
Waveform
ba
ba
m
+
=
Modulation
Factor
The RF waveform is measured with
a calibration coil specified in ISO/IEC 10373-6.
RF=High RF=Low RF=High
ba
RF
Waveform
ba
ba
m
+
=
Modulation
Factor
The RF waveform is measured with
a calibration coil specified in ISO/IEC 10373-6.
RF=High RF=Low RF=High
a
VRFH*
Chapter 6 Electrical characteristics
85
Revision History
Revised on May 15, 2013
Purpose Version 0.1 Version xx
Page Section Comments Page Section Comments
Revised on Aug 28, 2013
Purpose Version 0.1a Version 1.0
Page Section Comments Page Section Comments
--
--
--
--
--
--
Ver No. Update
Modify
All
pages Figure/Table No.
All
pages Figure/Table No. modify
Revised on Sep 30, 2013
Purpose Version 1.0 Version 1.1
Page Section Comments Page Section Comments
Modify
P24
Section3
Table3.1
P24
Section3
Table3.1 Update
Revised on Oct.09, 2013
Purpose Version 1.1 Version 1.2
Page Section Comments Page Section Comments
Modify P47 Table4-10
Physical adr 0x0003 to 0x0004
Value : 0x0018
Supplement : --
P47 Table4-10
Physical adr 0x0003 to 0x0004
Value : 0x0017
Supplement : (Note:)
Add
P47 -- -- P47 -- Note:
Revised on Dec.04, 2013
Purpose Version 1.2 Version 1.21
Page Section Comments Page Section Comments
Modify
ALL
ALL
Typo error
ALL
ALL
modify
Purpose Version 1.21 Version 1.22
Page Section Comments Page Section Comments
Modify
P30
Section3
HW2 adr 0x01FC
P30
Section3
HW2 adr 0x01FD
Chapter 6 Electrical characteristics
86
Revised on Feb.24, 2015
Purpose Version 1.22 Version 1.3
Page Section Comments Page Section Comments
Add --- --- --- P77 ---
Chapter6
Electrical characteristics
Request for your special attention and precautions
in using the technical information and semiconductors described in this book
(1) If any of the products or technical information described in this book is to be exported or provided to non-residents, the
laws and regulations of the exporting country, especially, those with regard to security export control, must be observed.
(2) The technical information described in this book is intended only to show the main characteristics and application circuit
examples of the products. No license is granted in and to any intellectual property right or other right owned by
Panasonic Corporation or any other company. Therefore, no responsibility is assumed by our company as to the
infringement upon any such right owned by any other company which may arise as a result of the use of technical
information de-scribed in this book.
(3) The products described in this book are intended to be used for general applications (such as office equipment,
communications equipment, measuring instruments and household appliances), or for specific applications as expressly
stated in this book.
Please consult with our sales staff in advance for information on the following applications, moreover please exchange
documents separately on terms of use etc.: Special applications (such as for in-vehicle equipment, airplanes, aerospace,
automotive equipment, traffic signaling equipment, combustion equipment, medical equipment and safety devices) in
which exceptional quality and reliability are required, or if the failure or malfunction of the products may directly
jeopardize life or harm the human body.
Unless exchanging documents on terms of use etc. in advance, it is to be understood that our company shall not be held
responsible for any damage incurred as a result of or in connection with your using the products described in this book
for any special application.
(4) The products and product specifications described in this book are subject to change without notice for modification
and/or improvement. At the final stage of your design, purchasing, or use of the products, therefore, ask for the most up-
to-date Product Standards in advance to make sure that the latest specifications satisfy your requirements.
(5) When designing your equipment, comply with the range of absolute maximum rating and the guaranteed operating
conditions (operating power supply voltage and operating environment etc.). Especially, please be careful not to exceed
the range of absolute maximum rating on the transient state, such as power-on, power-off and mode-switching. Other-
wise, we will not be liable for any defect which may arise later in your equipment.
Even when the products are used within the guaranteed values, take into the consideration of incidence of break down
and failure mode, possible to occur to semiconductor products. Measures on the systems such as redundant design,
arresting the spread of fire or preventing glitch are recommended in order to prevent physical injury, fire, social damages,
for example, by using the products.
(6) Comply with the instructions for use in order to prevent breakdown and characteristics change due to external factors
(ESD, EOS, thermal stress and mechanical stress) at the time of handling, mounting or at customer's process. We do
not guarantee quality for disassembled products or the product re-mounted after removing from the mounting board.
When using products for which damp-proof packing is required, satisfy the conditions, such as shelf life and the elapsed
time since first opening the packages.
(7) When reselling products described in this book to other companies without our permission and receiving any claim of
request from the resale destination, please understand that customers will bear the burden.
(8) This book may be not reprinted or reproduced whether wholly or partially, without the prior written permission of our
company.
No.010618
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic:
MN63Y1212-E1