Product data sheet Characteristics RXM4AB2B7 miniature plug-in relay - Zelio RXM - 4 C/O - 24 V AC - 6 A - with LED Range of product Zelio Relay Series name Miniature Product or component type Plug-in relay Device short name RXM Contacts type and composition 4 C/O Contacts operation Standard Control circuit voltage 24 V AC [Ithe] conventional enclosed thermal current 6 A at <= 55 C Status LED With Control type Pushbutton Coil interference suppression Without Utilisation coefficient 20 % Sale per indivisible quantity 10 Complementary [Ui] rated insulation voltage 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL [Uimp] rated impulse withstand voltage 4 kV conforming to IEC 61000-4-5 Contacts material Silver alloy (Ag/Ni) [Ie] rated operational current 3 A (AC-1/DC-1) NC conforming to IEC 6 A (AC-1/DC-1) NO conforming to IEC 8 A (AC-1/DC-1) conforming to UL Minimum switching current 10 mA Maximum switching voltage 250 V AC/DC Minimum switching voltage 17 V Resistive rated load 6 A at 250 V AC 6 A at 28 V DC Maximum switching capacity 1500 VA, AC circuit 168 W, DC circuit Minimum switching capacity 170 mW Operating rate <= 20 cyc/mn (under load) <= 300 cyc/mn (no-load) Mechanical durability 10000000 cycles Electrical durability 100000 cycles for resistive load Average consumption in W 0.9 W, DC circuit Average consumption in VA 1.2, AC circuit Drop-out voltage threshold >= 0.1 Uc (DC >= 0.15 Uc (AC Operating time 20 ms between coil de-energisation and making of the Off-delay contact (AC/DC) 20 ms between coil energisation and making of the On-delay contact (AC/DC) Average resistance 180 Ohm, AC circuit at 20 C +/- 15 % Rated operational voltage limits 19.2...26.4 V AC Protection category RT I Operating position Any position CAD overall width 21 mm 7/9/2011 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main CAD overall height 27 mm CAD overall depth 55 mm Product weight 0.037 kg Environment Dielectric strength 1500 V AC (between contacts) 1550 V AC (between coil and contact) 1550 V AC (between poles) Product certifications CSA UL Standards CSA C22-2 No 14 EN/IEC 61810-1 (iss. 2) UL 508 Ambient air temperature for storage -40...85 C Ambient air temperature for operation -40...55 C Vibration resistance 3 gn (f = 10...150 Hz), amplitude +/- 1 mm (on opening) conforming to EN/IEC 60068-2-27 5 gn (f = 10...150 Hz), amplitude +/- 1 mm (on closing) conforming to EN/IEC 60068-2-27 IP degree of protection IP40 conforming to EN/IEC 60529 Shock resistance 15 gn on closing conforming to EN/IEC 60068-2-27 15 gn on opening conforming to EN/IEC 60068-2-27 RoHS EUR status Compliant RoHS EUR conformity date 0801 2 Product data sheet Dimensions Drawings RXM4AB2B7 Miniature Relay Dimensions Pin Side View 3 Product data sheet Connections and Schema Miniature Relay Wiring Diagram Symbols shown in blue correspond to Nema marking. 4 RXM4AB2B7 Product data sheet Performance Curves RXM4AB2B7 RXM Miniature Relays Electrical Durability of Contacts Durability (inductive load) = durability (resistive load) x reduction coefficient. Resistive AC load X Y A B C D Switching capacity (kVA) Durability (Number of operating cycles) RXM2AB*** RXM3AB*** RXM4*** RXM4G*** Reduction coefficient for inductive AC load (depending on power factor cos ) Y Reduction coefficient (A) Maximum switching capacity on resistive DC load X Y A B C D Voltage DC Current DC RXM2AB*** RXM3AB*** RXM4*** RXM4G*** 5