Product data sheet
Characteristics
XY2CJL19H7
e-stop rope pull switch XY2CJ - left side - 2NC
+1NO - 1/2" NPT
Main
Range of product Preventa XY2
Product or component type Latching emergency stop rope pull switch
Device short name XY2C
Housing colour Red RAL 3000
Overvoltage category Class I conforming to EN/IEC 61140
Complementary
Local signalling Color indicator
Number of cables 1
Trigger cable maximum length 30 m
Body material Zamak
Cover material Galvanised steel
Reset By pull button
Contacts type and composition 2 NC + 1 NO
Contact operation Slow-break
Trigger cable anchor point LH side
Connections - terminals Screw clamp terminal 1 x 0.34...1 x 1 mm²
Screw clamp terminal 1 x 0.34...2 x 0.75 mm²
Tightening torque 0.8...1.2 N.m
Cable entry number 1 tapped entry for 1/2" NPT conduit entry
Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/
ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO
13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC
61508
Safety reliability data B10d = 500000 with value given for a life time of 20 years limited by mechanical or contact wear
conforming to IEC 60947-5-5
Marking CE
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Jun 1, 2019
1
Mechanical durability 100000 cycles
Distance between cable supports 5 m
[Ie] rated operational current 0.1 A at 250 V DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A
1.5 A at 240 V AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal
current
6 A
[Ui] rated insulation voltage 300 V (degree of pollution: conforming to UL 508
300 V (degree of pollution: conforming to CSA C22.2 No 14
400 V (degree of pollution: 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1
Positive opening With conforming to EN/IEC 60947-5-1
Resistance across terminals <= 25 MOhm conforming to NF C 93-050 method A
<= 25 MOhm conforming to EN/IEC 60255-7 category 3
Short-circuit protection 6 A by gG cartridge fuse conforming to EN/IEC 60269
Terminals description ISO n°1 (13-14)NO
(21-22)NC
(31-32)NC
Product weight 0.669 kg
Environment
Standards EN/IEC 60204-1
EN/IEC 60947-5-1
EN/IEC 60947-5-5
EN/ISO 13850
UL 508
Machinery directive 2006/42/EC
CSA C22.2 No 14
Work equipment directive 2009/104/EC
Product certifications UL for category NISD emergency stop devices
CSA
CCC
Protective treatment TC
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -40...70 °C
Vibration resistance 10 gn (f = 10...150 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 50 gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protection IP66 for conforming to IEC 60529
IP67 for conforming to IEC 60529
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1415 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Need no specific recycling operations
2
Product data sheet
Dimensions Drawings
XY2CJL19H7
Dimensions
(1) Tapped entries for 1/2" NPT
(2) Maximum extension.
3
Product data sheet
Performance Curves
XY2CJL19H7
Electrical Curves
AC Supply 50/60 Hz Inductive Circuit
3-pole Contact Block
Y Millions of operating cycles
X Current in A
DC Supply Power Broken in for 1 Million Operating Cycles Inductive Circuit
Voltage V 24 48 120
W 4 3 2
4