PTL Series - Pt-Sensors
Vishay Beyschlag
Document Number: 28775 For technical questions, contact: nlr@vishay.com www.vishay.com
Revision: 08-Feb-12 13
Leaded Platinum Temperature Sensor
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
PTL Temperature Sensors are the perfect choice for the
most fields of modern electronics. The highly controlled
platinum thin film manufacturing process guarantees an
outstanding stability of temperature characteristics. Typical
applications include temperature measurement in process
controls in industrial electronics, and precise temperature
measurement in medical equipment.
FEATURES
Advanced platinum thin film technology
Standardized according IEC 60751
Outstanding stability of temperature characteristics
Short reaction times down to t0.9 8 s
3 ceramic body sizes available
Radial terminations
APPLICATIONS
Temperature measurement and control in
Industrial electronics
Medical electronics
Notes
(1) Customized solutions on request, tolerance class F0.15 up to 300 °C, class F0.3 up to 500 °C
(2) Valid for sensor element only
(3) Indicated measurement currents can be applied continuously with self-heating effect of less than 0.1 °C at 0 °C in still air
TECHNICAL SPECIFICATIONS
DESCRIPTION PTL 1112 PTL 1222 PTL 1252
Resistance values R0 at 0 °C (1) 100 , 500 ,
1000
100 , 500 ,
1000
100 , 500 ,
1000 , 10 000
Temperature coefficient (0 °C to + 100 °C) + 3850 ppm/K
Tolerance class F0.15, F0.3 (1)
Temperature range - 50 °C up to + 550 °C (1)
Long term stability R0/R0 (250 h at UCT) < ± 0.1 %
Insulation resistance > 10 M
Measurement current Imea. (DC) (3)
Up to 1.0 mA for 100
Up to 0.4 mA for 500
Up to 0.3 mA for 1 k
Up to 0.1 mA for 10 k
Self-heating (2) Flowing air (v = 3.0 m/s) 0.25 K/mW 0.2 K/mW 0.17 K/mW
Still air (v = 1.0 m/s) 0.6 K/mW 0.4 K/mW 0.35 K/mW
Thermal response time (2) Flowing air (v = 3.0 m/s)
t0.5 2.5 s t0.5 3 s t0.5 5 s
t0.9 8 s t0.9 10 s t0.9 15 s
Material of leads Platinum clad Ni (1)
Length of leads 10 mm (1)
Diameter of leads 0.2 mm (1)
www.vishay.com For technical questions, contact: nlr@vishay.com Document Number: 28775
14 Revision: 08-Feb-12
PTL Series - Pt-Sensors
Vishay Beyschlag Leaded Platinum Temperature Sensor
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
DIMENSIONS in millimeters
PRODUCTION
Production is strictly controlled and follows an extensive set
of instructions established for reproducibility. A
homogeneous film of platinum is deposited on a high grade
ceramic body (96 % AI2O3). The sensor-elements are
covered by a protective coating designed for electrical,
mechanical and climatic protection.
QUALITY
The result of the determined production is verified by an
extensive testing procedure performed on 100 % of the
individual sensors. Only accepted products are laid directly
into the waffle trays. The resistance values and tolerances
according to DIN EN 60751 are given for the device including
the standard leads. Any additional wiring will change
resistance values for the total setup.
ASSEMBLY
The Pt-sensors are suitable for all standard assembly
processes like crimping, soldering, brazing and welding
(LASER- or resistive welding).
The parameters of the assembly process should be chosen
in accordance with the used wire material. It is
recommended to verify the parameters by pre-testing.
The assembly process of the sensor should be in compliance
with the following guidelines and recommendations:
Fixation of only one lead during assembly
Tensile forces parallel to the leads < 5 N
Avoiding of large temperature gradients between the
welding region and the sensor during assembly, e.g. by
using a cooled clamp with a good thermal conductivity
Radius of curvature of the leads > 0.3 mm
Curvature or torsion strain > 3 mm away form the sensor
element
After assembly we recommend to fix the leads in the
welded region with a strain relief
ENVIRONMENTAL CONDITIONS
Unprotected sensor-elements are usable under dry
environmental conditions only. Platinum-plated nickel leads
enable the usage in applications with ambient temperatures
up to 550 °C. The environment of the sensor application
should be without any corrosive substances (e.g. potassium
hydroxide or hydrogen fluoride) or other contaminants which
could affect the sensor, especially shifting the temperature
coefficient of the sensor. This has also to be considered
during the assembly process.
DIRECTIVES
All products comply with the CEFIC-EECA-EICTA list of legal
restrictions on hazardous substances.
This includes full compatibility with the following directives:
2000/53/EC End of Vehicle Life Directive (ELV)
2000/53/EC Annex II to End of Vehicle Life Directive
(ELV II)
2002/95/EC Restriction of the use of Hazardous
Substances Directive (RoHS)
2002/96/EC Waste Electrical and Electronic Equipment
Directive (WEEE)
APPROVALS
The Pt-sensors are tested in accordance with IEC 60751/
DIN EN 60751.
DIMENSIONS - PTL sensor type, relevant physical dimensions
TYPE H1H2LWØ dI F S
MASS
(mg)
PTL 1112 1.0 ± 0.25 0.4 ± 0.05 1.6 ± 0.2 1.25 ± 0.2 0.2 ± 0.02 10.0 ± 1.0 0.55 0.35 16
PTL 1222 1.0 ± 0.25 0.4 ± 0.05 2.3 ± 0.2 2.0 ± 0.3 0.2 ± 0.02 10.0 ± 1.0 0.90 0.55 24
PTL 1252 1.0 ± 0.25 0.4 ± 0.05 5.0 ± 0.2 2.0 ± 0.3 0.2 ± 0.02 10.0 ± 1.0 0.90 0.55 36
L
W
H1H2
Ø d
I
S
F
Document Number: 28775 For technical questions, contact: nlr@vishay.com www.vishay.com
Revision: 08-Feb-12 15
PTL Series - Pt-Sensors
Leaded Platinum Temperature Sensor Vishay Beyschlag
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Notes
(1) Products can be ordered using either the PART NUMBER or the PRODUCT DESCRIPTION
(2) The part number is shown to facilitate the introduction of unified part numbering system
(3) Please refer to table PACKAGING
(4) We recommend that the production description is used to minimize the possibility of errors in order handling
PART NUMBER AND PRODUCT DESCRIPTION (1)
PART NUMBER (2): PTL122201B1K00KU00
TYPE TYPE CODE SPECIAL
CHARACTER
TOLERANCE
CLASS
RESISTANCE
VALUE PACKAGING (3) SPECIAL
3 digits
PTL = Platinum
Temperature
Sensor Leaded
4 digits
1112
1222
1252
1 digit
0 = Neutral
2 digits
1A = Class F0.15
1B = Class F0.3
4 digits
100R = 100
500R = 500
1K00 = 1000
10K0 = 10 k
2 digits
Waffles in a box
KU
K1
2 digits
00 = Standard
PRODUCT DESCRIPTION (4): PTL 1222 -B KU 1K0
PTL 1222 -B KU 1K0
TYPE TYPE CODE TOLERANCE
CLASS PACK AGI NG (3) RESISTANCE VALUE
PTL = Platinum
Temperature
Sensor Leaded
1112
1222
1252
A = Class F0.15
B = Class F0.3
Waffles in a box
KU
K1
100R = 100
500R = 500
1K0 = 1000
10K0 = 10 000
PACKAGING
MODEL
WAFFLE PACK
PIECES/WAFFLES IN A BOX CODE
PTL
100 KU
1000 K1
12LTP221B1K00KU000
www.vishay.com For technical questions, contact: nlr@vishay.com Document Number: 28775
16 Revision: 08-Feb-12
PTL Series - Pt-Sensors
Vishay Beyschlag Leaded Platinum Temperature Sensor
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
FUNCTIONAL PERFORMANCE
The temperature resistance relationships of the PTL series
follow different equations:
for the temperature range from - 50 °C up to 0 °C:
RT = R0 x (1 + A x T + B x T2 + C x (T - 100 °C) x T3)
and for the temperature range from 0 °C up to + 550 °C:
RT = R0 x (1 + A x T + Bx T2)
RT: Resistance as a function of temperature
R0: Nominal resistance value at 0 °C
T: Temperature in °C
According to IEC 60751/DIN EN 60751 the values of the
coefficients are:
A = 3.9083 x 10-3 °C-1
B = - 5.775 x 10-7 °C-2
C = - 4.183 x 10-12 °C-4
The temperature tolerances values of the PTL series are
classified by the following equation:
Class F0.15: TF0.15 ± (0.15 + 0.002 xT
(valid from - 50 °C to 300 °C)
Class F0.3: TF0.30 ± (0.30 + 0.005 xT
(valid from - 50 °C to 500 °C)
NOMINAL RESISTANCE VALUE
TEMPERATURE
(°C)
R0 = 100 R0 = 500 R0 = 1000 R0 = 10 000 CLASS F0.15 CLASS F0.30
NOMINAL
RESISTANCE
()
NOMINAL
RESISTANCE
()
NOMINAL
RESISTANCE
()
NOMINAL
RESISTANCE
()
TOLERANCE
(K)
TOLERANCE
(K)
- 50 80.306 401.53 803.06 8030.6 ± 0.25 ± 0.55
- 25 90.192 450.96 901.92 9019.2 ± 0.20 ± 0.43
0 100 500 1000 10 000 ± 0.15 ± 0.30
25 109.73 548.67 1097.3 10 973 ± 0.20 ± 0.43
50 119.40 596.99 1194.0 11 940 ± 0.25 ± 0.55
75 128.99 644.94 1289.9 12 899 ± 0.30 ± 0.68
100 138.51 692.53 1385.1 13 851 ± 0.35 ± 0.80
125 147.95 739.76 1479.5 14 795 ± 0.40 ± 0.93
150 157.33 786.63 1573.3 15 733 ± 0.45 ± 1.05
175 166.63 833.13 1666.3 16 663 ± 0.50 ± 1.18
200 175.86 879.28 1758.6 17 586 ± 0.55 ± 1.30
225 185.01 925.07 1850.1 18 501 ± 0.60 ± 1.43
250 194.10 970.49 1941.0 19 410 ± 0.65 ± 1.55
275 203.11 1015.6 2031.1 20 311 ± 0.70 ± 1.68
300 212.05 1060.3 2120.5 21 205 ± 0.75 ± 1.80
325 220.92 1104.6 2209.2 22 092 ± 1.93
350 229.72 1148.6 2297.2 22 972 ± 2.05
375 238.44 1192.2 2384.4 23 844 ± 2.18
400 247.09 1235.5 2470.9 24 709 ± 2.30
425 255.67 1278.4 2556.7 25 567 ± 2.43
450 264.18 1320.9 2641.8 26 418 ± 2.55
475 272.61 1363.1 2726.1 27 261 ± 2.68
500 280.98 1404.9 2809.8 28 098 ± 2.80
525 289.27 1446.3 2892.7 28 927 ± 2.93
550 297.49 1487.4 2974.9 29 749
Document Number: 28775 For technical questions, contact: nlr@vishay.com www.vishay.com
Revision: 08-Feb-12 17
PTL Series - Pt-Sensors
Leaded Platinum Temperature Sensor Vishay Beyschlag
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
- 100 50 600
Temperature in °C
- 50 0 100 150 200 250 300 350
Ratio R/R0
400 450 500 550
0.00
1.00
2.00
3.50
0.50
1.50
2.50
3.00
- 100 600
Temperature in °C
0100 200 300
Temp. Tol. (± °C)
Tolerance for Class F0.15
0.00
0.50
1.00
1.50
1.75
2.00
R
0
Tol. (± %)
0.25
0.75
1.25
400 500
0.00
0.50
1.50
4.00
1.00
2.00
2.50
3.50
3.00
Temp. Tol. (± °C)
R0 Tol. (± %)
- 50 50 150 250 350 450 550
- 100 600
0100 200 300 400 500
- 50 50 150 250 350 450 550
Temperature in °C
Temp. Tol. (± °C)
Tolerance for Class F0.3
0.00
0.50
1.00
1.50
1.75
2.00
R
0
Tol. (± %)
0.25
0.75
1.25
0.00
0.50
1.50
4.00
1.00
2.00
2.50
3.50
3.00
Temp. Tol. (± °C)
R0 Tol. (± %)
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 12-Mar-12 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.