Catalog 1308242 Issued 3-03 PRODUCTS UNLIMITED Model 93 - 3100 series Definite Purpose Contactor 4-pole, 25-40 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Features Environmental Data * 4-pole contactors. * Convenient "universal" mounting plate. * Optional interlock/auxiliary switches available. Temperature Range: Storage and Operating: -40C - +65C. Flammability: UL 94-HB housing. Mechanical Data Contact Termination: 25, 30 FLA Models Type: #10-32 Screw with quad 0.250" (6.35 mm) quick connects. Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.) Tightening Torque: 25 in.-lbs. 40 FLA Models Type: Box Lug with dual 0.250" (6.35 mm) quick connects. Wire Size: 14-4 Cu/Al AWG Tightening Torque: 40 in.-lbs. Coil Termination: Dual 0.250" (6.35 mm) quick connects, standard. A 0.250" quick connect and a #6-32 screw, optional. Arc Cover: Optional on 25-30 FLA models, standard on 40 FLA models. Weight: 24 oz. (683 g) approximately Contact Data @ 25C Arrangements: 4 Form X (4PST-NO-DM). Maximum Ratings: See Contact Ratings Table. Material: Silver Cadmium Oxide. Coil Data @ 25C Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below. Insulation Class: UL Class B (130C). Duty Cycle: Continuous. Contact Ratings Full Load Amps Number of Poles Line Voltage Locked Rotor Amps Resistive Amps Rating 25 3 240/277 480 600 150 125 100 35 35 35 30 3 240/277 480 600 180 150 120 40 40 40 40 3 240/277 480 600 240 200 160 50 50 50 Nominal Coil Voltage Maximum Pickup Volts Drop-Out Volts Range Nominal Inrush VA @ 50 Hz Nominal Inrush VA @ 60 Hz Nominal Sealed VA @ 50 Hz Nominal Sealed VA @ 60 Hz Nominal DC Resistance - Ohms 24 19.2 6 -15 68 60 14 9 5 Voltage Maximum Horsepower Single Phase Three Phase 110/120 200/208 240/277 480 110/120 200/208 240/277 480 110/120 200/208 240/277 480 2 5 2 5 3 7.5 - 7.5 10 15 10 10 15 10 10 20 Coil Data Dimensions are shown for 836 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. 120 93 20 - 70 68 60 14 9 148 208/240 177 40 - 140 68 60 14 9.5 520 Specifications and availability subject to change. 277 220 50-185 58 52 11 9.5 750 480 384 150 - 270 48 52 11 9 2700 www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 PRODUCTS UNLIMITED Ordering Information Typical Part No. B 3100 - 40 Q 9 999 1. Series: 3100 = 4-pole, 25-40 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 40 = 4 Form X (4PST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC U = 208/240VAC H = 480VAC J = 120VAC, molded M = 277VAC, molded T = 120VAC V = 277VAC I = 24VAC, molded K = 208/240VAC, molded W = 480VAC, molded 5.Contact Ratings (Inductive): 8 = 25 FLA 9 = 30 FLA 10 = 40 FLA 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7. Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options. Standard part numbers listed below are more likely to be available from stock. None at present. Termination Options Outline Dimensions 3.055 (77.6) .250 (6.35) 2.00 (50.8) .250 (6.35) .253 (6.43) 3.25 (82.55) 3.125 (79.38) 3.75 (95.25) 2.493 (63.3) 2.633 (66.9) .203 TYP (5.156) .203 TYP (5.156) Standard on 25, 30 FLA #10-32 Combination Phillips, Slotted & 5/16 Hex Head #12 Washer Special on 25, 30 FLA #10-32 Sems Screw with Pressure Plate Standard on 40 FLA Lug accepts 14-4 Cu/Al AWG ORDERING NOTE: "Standard" terminals need not be specified in the "Ordering Information" chart above. "Special" terminals are offered on a special order basis. Special order items may be subject to extended leadtimes and significant minimum order quantities. Your Tyco Electronics sales engineer must consult with the factory before providing price and availability information regarding items with these options. Shown with Optional Auxiliary Switch Auxiliary Switches Various interlock / auxiliary switches are available for the Model 93 contactor. Equipped with 0.250" (6.35) Quick Connect Terminals Factory Modifications Contact Config. NO NC Single unit interlock 1 0 configurations listed. 0 1 Maximum of two. Must 1 1 be same polarity. 2 0 See footnote (1) for ratings. 0 2 2 2 SPDT Circuit 1 1 See footnote (2) for ratings. 2 2 SPDT Dry Circuit, 0.1 amp max. 1 1 Gold Flashed Contacts 2 2 Description NORMALLY OPEN -303 STYLE NORMALLY OPEN & CLOSED -332 STYLE NORMALLY CLOSED -331 STYLE SPDT -337 & -341 STYLE Equipped with #6-32 Screw Terminals & Saddle Clamps Factory Modifications Field Added Kits Description Contact Config. Kit Catalog Number of NO NC Number Kits Required Single unit interlock 1 0 34220-342N 1 configurations listed. 0 1 34220-343N 1 Maximum of two. Must 1 1 34220-344N 1 be same polarity. (note 1) Footnotes: Ratings of Auxiliary Interlocks / Switches (1) Contact Rating Single Circuit NO or NC (2) Contact Rating SPDT (337): and two circuit NO/NC: 10A, 1/3 HP, 125 or 250 VAC 1/2A, 125 VDC; 1/4A, 250 VDC: 120V 240V 480V 600V Break 3.0A 1.5A 0.75A 0.6A 4A 120 VAC on Lamp Load Make 30A 15A 7.5A 6A Continuous 10A 10A 10A 10A W/ #6-32 SCREW & SADDLE CLAMP -344 STYLE Dimensions are shown for reference purposes only. Field Added Kits Kit Catalog Number of Number Kits Required 34220-303N 1 34220-331N 1 34220-332N 1 34220-303N 2 34220-331N 2 34220-332N 2 34220-337N 1 34220-337N 2 34220-341N 1 34220-340N 1 Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 837